1.
Radiology ; 311(1): e240020, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38652027

RESUMO

Gadolinium-based contrast agents (GBCAs) have augmented the capabilities of MRI, which has led to their widespread and increasing use in radiology practice. GBCAs are introduced into the environment through disposal of unused product and elimination after intravenous injection, both primarily via liquid dispersion into the environment. This human introduction of gadolinium into the environment, referred to as anthropogenic gadolinium, is associated with the detection of gadolinium in water systems, raising concerns for potential adverse impact and prompting certain mitigation actions. This article summarizes the existing knowledge and problem scope, conveys the relevant underlying chemical principles of chelate dissociation, and offers an inferred perspective that the magnitude of the problem is most unlikely to cause human harm. The merits and limitations regarding possible mitigation tactics, such as collecting urine after GBCA administration, use of lower-dose high-relaxivity macrocyclic GBCAs, and the option for virtual contrast-enhanced examinations, will be discussed. Finally, the potential for monitoring gadolinium uptake in bone will be presented, and recommendations for future research will be offered. © RSNA, 2024 See also the article by Ibrahim et al in this issue. See also the article by McKee et al in this issue.


Assuntos
Meios de Contraste , Gadolínio , Poluição Química da Água , Imageamento por Ressonância Magnética
2.
Radiographics ; 44(2): e230142, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38175803

RESUMO

Multiparametric MRI-the most accurate imaging technique for detection of prostate cancer-has transformed the landscape of prostate cancer diagnosis by enabling targeted biopsies. In a targeted biopsy, tissue samples are obtained from suspicious regions identified at prebiopsy diagnostic MRI. The authors briefly compare the different strategies available for targeting an MRI-visible suspicious lesion, followed by a step-by-step description of the direct MRI-guided in-bore approach and an illustrated review of its application in challenging clinical scenarios. In this technique, direct visualization of the needle, needle guide, and needle trajectory during the procedure provides a precise and versatile strategy to accurately sample suspicious lesions, improving detection of clinically significant cancers. Published under a CC BY 4.0 license Test Your Knowledge questions for this article are available in the supplemental material.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Antígeno Prostático Específico
3.
J Comput Assist Tomogr ; 47(1): 38-44, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35995580

RESUMO

BACKGROUND: The prostatic apex is the most frequent location of positive surgical margin (PSM) after surgery. Data regarding the ability of multiparametric magnetic resonance imaging (mpMRI) to prospectively identify men at risk for apical PSMs (aPSMs) using a structured report are lacking. OBJECTIVES: The aims of the study are to determine and to compare the rate of aPSM in men with versus without prospectively flagged at-risk prostate lesions during clinical mpMRI interpretation using whole-mount histopathology as the reference standard. METHODS: This single-center, retrospective study of prospectively collected data included treatment-naive men with abnormal 3T mpMRI (PI-RADS v2 score ≥3) between January 2016 and December 2018 followed by surgery. During routine clinical interpretation, radiologists flagged prostate lesions abutting the apical most gland and/or encircling the distal most prostatic urethra using standardized language available as a "pick list" option in the structured report. Logistic regression was used to compare the rate of PSM in 2 groups (flagged vs nonflagged men). Propensity score covariate adjustment corrected for potential selection bias according to age, prostate-specific antigen (PSA), PSA density, grade group, and pT stage. The estimate was further adjusted by including surgeon as a covariate. RESULTS: A total of 428 men were included. A statistically significant higher proportion of aPSMs was noted in flagged (56% [51/91]) compared with nonflagged apical lesions (31% [105/337]; adjusted odds ratio, 2.5; 95% confidence interval, 1.6-4.1; P < 0.01). The difference in aPSM between both groups also varied according to the surgeon performing the RP. Prostate-specific antigen, PSA density, lesion size, apical location, Prostate Imaging Reporting & Data System score, grade group, pT stage, and surgeon's experience were associated with higher PSM rate. Biochemical recurrence, defined as PSA greater than 0.2 ng/mL on 2 measurements after RP, was significantly associated with PSM status (propensity score adjusted odds ratio, 3.1; 95% confidence interval, 1.8-5.3; P < 0.0001); however, patients flagged by radiologists did not have a significant difference in biochemical recurrence rates as compared with nonflagged patients ( P = 0.11). CONCLUSIONS: Standard language built into structured reports for mpMRI of the prostate helps identify preoperatively patients at risk for aPSM. CLINICAL IMPACT: Multiparametric MRI is able to identify patients at increased risk for aPSM, and this information can be conveyed in a structured report to urologists, facilitating patient counseling and treatment decisions.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/cirurgia , Próstata/patologia , Antígeno Prostático Específico , Margens de Excisão , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Prostatectomia/métodos
4.
Magn Reson Med ; 86(3): 1463-1471, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33929055

RESUMO

PURPOSE: To develop a true single shot turbo spin echo (SShTSE) acquisition with Dixon for robust T2 -weighted abdominal imaging with uniform fat and water separation at 3T. METHODS: The in-phase (IP) and out-of-phase (OP) echoes for Dixon processing were acquired in the same repetition time of a SShTSE using partial echoes. A phase-preserved bi-directional homodyne reconstruction was developed to compensate the partial echo and the partial phase encoding of SShTSE. With IRB approval, the SShTSE-Dixon was compared against standard SShTSE, without and with fat suppression using spectral adiabatic inversion recovery (SPAIR) in 5 healthy volunteers and 5 patients. The SNR and contrast ratio (CR) of spleen to liver were compared among different acquisitions. RESULTS: The bi-directional homodyne reconstruction successfully minimized ringing artifacts because of partial acquisitions. SShTSE-Dixon achieved uniform fat suppression compared to SShTSE-SPAIR with fat suppression failures of 1/10 versus 10/10 in the axial plane and 0/5 versus 5/5 in the coronal plane, respectively. The SNRs of the liver (12.2 ± 4.9 vs. 11.7 ± 5.2; P = .76) and spleen (25.9 ± 11.6 vs. 23.7 ± 9.7; P = .14) were equivalent between fat-suppressed images (SShTSE-Dixon water-only and SShTSE-SPAIR). The SNRs of liver (14.4 ± 5.7 vs. 13.4 ± 5.0; P = .60) and spleen (26.5 ± 10.1 vs. 25.7 ± 8.5; P = .56) were equivalent between non-fat-suppressed images (SShTSE-Dixon IP and SShTSE). The CRs of spleen to liver were also similar between fat-suppressed images (2.6 ± 0.4 vs. 2.5 ± 0.5; P =.92) and non-fat-suppressed images (2.3 ± 0.6 vs. 2.2 ± 0.4; P =.84). CONCLUSION: SShTSE-Dixon generates robust abdominal T2 -weighted images at 3T with and without uniform fat suppression, along with perfectly co-registered fat-only images in a single acquisition.


Assuntos
Imageamento por Ressonância Magnética , Água , Tecido Adiposo/diagnóstico por imagem , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador
5.
AJR Am J Roentgenol ; 217(2): 395-403, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32876473

RESUMO

BACKGROUND. On the basis of expert consensus, PI-RADS version 2.1 (v2.1) introduced the transition zone (TZ) atypical benign prostatic hyperplasia (BPH) nodule, defined as a TZ lesion with an incomplete or absent capsule (T2 score, 2). PI-RADS v2.1 also included a revised scoring pathway whereby such nodules, if exhibiting marked restricted diffusion (DWI score, 4-5), are upgraded from overall PI-RADS category 2 to category 3 (2 + 1 TZ lesions). OBJECTIVE. The purpose of this study was to compare the rates of detection of clinically significant prostate cancer (csPCa) in prospectively reported 2 + 1 TZ lesions, as defined by PI-RADS v2.1, and conventional 3 + 0 TZ lesions with targeted biopsy as the reference standard. METHODS. This retrospective study included men with no known PCa or with treatment-naïve grade group (GG) 1 PCa who underwent 3-T multiparametric MRI of the prostate with prospective reporting by means of PI-RADS v2.1. Patients with at least one PI-RADS category 3 TZ lesion who underwent targeted biopsy formed the final sample. Biopsy results were summarized descriptively for 2 + 1 and 3 + 0 lesions. Generalized estimating equations were used to compare csPCa detection rates between groups. Associations between csPCa in 2 + 1 lesions and patient age, PSA level, prostate volume, PSA density, biopsy history, lesion size, and lesion ADC were tested with Kruskal-Wallis and Fisher exact tests. RESULTS. Among 1238 eligible patients who underwent MRI reported with PI-RADS v2.1, 2 + 1 lesions were reported in 6% (n = 69) and 3 + 0 TZ lesions in 7% (n = 87) of patients. No PCa, GG1 PCa, or csPCa was found in 84% (n = 41), 10% (n = 5), and 6% (n = 3) of 49 patients with 2 + 1 lesions who underwent targeted biopsy. Nor were they found in 74% (n = 45), 15% (n = 9), and 11% (n = 7) of 61 patients with 3 + 0 lesions who underwent targeted biopsy. The csPCa detection rate was not significantly different between 2 + 1 and 3 + 0 lesions (p = .31). All cases of csPCa were GG2, except for one 3 + 0 lesion with a GG3 tumor. No clinical or imaging variable was associated with csPCa in 2 + 1 lesions. CONCLUSION. The rate of csPCa in atypical BPH nodules with marked restricted diffusion was low (6%) and not significantly different from that of conventional 3 + 0 TZ lesions (11%). CLINICAL IMPACT. The results provide prospective clinical data about the revised TZ scoring criterion and pathway in PI-RADS v2.1 for atypical BPH nodules with marked restricted diffusion.


Assuntos
Imageamento por Ressonância Magnética/métodos , Hiperplasia Prostática/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Sistemas de Informação em Radiologia , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Hiperplasia Prostática/complicações , Neoplasias da Próstata/complicações , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
J Comput Assist Tomogr ; 45(2): 203-209, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33273160

RESUMO

OBJECTIVE: To determine the incremental detection rate of clinically significant prostate cancer (csPCa) provided by sequential cores during in-bore magnetic resonance imaging (MRI)-guided prostate biopsies. METHODS: Single-center, retrospective interpretation of prospectively acquired data in men without previous diagnosis of csPCa who underwent in-bore MRI-guided prostate biopsy between May 2017 and December 2019. Endpoints included detection of csPCa (grade group [GG] ≥ 2) and rate of GG upgrade provided by additional cores. Descriptive statistics presented as mean and standard deviation for the continuous variables, and frequency and percentage for the categorical variables. RESULTS: Four hundred and forty-three men with 747 lesions met eligibility criteria. Clinically significant prostate cancer was detected in 43.1% (322/747) of the biopsied lesions and GG 2 PCa or greater was identified by the first core in 78.3% (252/322) of them. On a per-core basis, cores 2, 3, 4, and 5 found new csPCa in 6% (42/744), 4% (26/719), 1% (2/137), and 0% (0/11) of the cases. Core biopsy 2, 3, 4, and 5 resulted in GG upgrade in 12% (91/744), 7% (49/719), 7% (9/137), and 0% (0/11) of the lesions, respectively. Each additional core was associated with a mean increase of 5 minutes in the duration of the biopsy. CONCLUSIONS: In men undergoing in-bore MRI-guided prostate biopsies, 3 targeted cores per lesion provide an optimal trade-off between detection of clinically significant tumors and biopsy duration.


Assuntos
Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Próstata , Neoplasias da Próstata , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
7.
J Comput Assist Tomogr ; 44(6): 808-811, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33065586

RESUMO

A dearth of women leaders in the field of radiology and affiliated industries persists despite a recognition of the importance, value, and impact that would derive from its rectification. A targeted educational collaboration, described herein, was established between academia and industry to address this deficit and to facilitate the placement of highly qualified women into leadership positions. The actionable platform offered has the potential to narrow the gap for underrepresented groups in professional leadership positions.


Assuntos
Pessoal de Saúde/estatística & dados numéricos , Mão de Obra em Saúde/estatística & dados numéricos , Liderança , Radiologia/estatística & dados numéricos , Feminino , Humanos
8.
J Comput Assist Tomogr ; 44(4): 479-484, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32433251

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic has necessitated rapid response plans to minimize risks of infection in the workforce while ensuring maintenance of essential functions of radiology departments. Plan adoption is, however, challenged by the need to coordinate with institutional efforts, a rapidly expanding number of patients, and the diversity of clinical and administrative functions in the department. Here, we describe the implementation of a response plan in an academic radiology department, challenges encountered, and tactics used to address these challenges.


Assuntos
Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Controle de Infecções/organização & administração , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Exposição Ocupacional/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Serviço Hospitalar de Radiologia/organização & administração , Gestão da Segurança , Betacoronavirus , COVID-19 , Humanos , Fatores de Risco , SARS-CoV-2 , Texas/epidemiologia
9.
BMC Med Imaging ; 19(1): 22, 2019 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-30819131

RESUMO

BACKGROUND: For most computer-aided diagnosis (CAD) problems involving prostate cancer detection via medical imaging data, the choice of classifier has been largely ad hoc, or been motivated by classifier comparison studies that have involved large synthetic datasets. More significantly, it is currently unknown how classifier choices and trends generalize across multiple institutions, due to heterogeneous acquisition and intensity characteristics (especially when considering MR imaging data). In this work, we empirically evaluate and compare a number of different classifiers and classifier ensembles in a multi-site setting, for voxel-wise detection of prostate cancer (PCa) using radiomic texture features derived from high-resolution in vivo T2-weighted (T2w) MRI. METHODS: Twelve different supervised classifier schemes: Quadratic Discriminant Analysis (QDA), Support Vector Machines (SVMs), naïve Bayes, Decision Trees (DTs), and their ensemble variants (bagging, boosting), were compared in terms of classification accuracy as well as execution time. Our study utilized 85 prostate cancer T2w MRI datasets acquired from across 3 different institutions (1 for discovery, 2 for independent validation), from patients who later underwent radical prostatectomy. Surrogate ground truth for disease extent on MRI was established by expert annotation of pre-operative MRI through spatial correlation with corresponding ex vivo whole-mount histology sections. Classifier accuracy in detecting PCa extent on MRI on a per-voxel basis was evaluated via area under the ROC curve. RESULTS: The boosted DT classifier yielded the highest cross-validated AUC (= 0.744) for detecting PCa in the discovery cohort. However, in independent validation, the boosted QDA classifier was identified as the most accurate and robust for voxel-wise detection of PCa extent (AUCs of 0.735, 0.683, 0.768 across the 3 sites). The next most accurate and robust classifier was the single QDA classifier, which also enjoyed the advantage of significantly lower computation times compared to any of the other methods. CONCLUSIONS: Our results therefore suggest that simpler classifiers (such as QDA and its ensemble variants) may be more robust, accurate, and efficient for prostate cancer CAD problems, especially in the context of multi-site validation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Diagnóstico por Computador , Análise Discriminante , Humanos , Bloqueio Interatrial , Masculino , Reconhecimento Automatizado de Padrão , Neoplasias da Próstata/patologia , Curva ROC , Sensibilidade e Especificidade , Máquina de Vetores de Suporte
10.
Proc Natl Acad Sci U S A ; 113(37): E5464-71, 2016 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-27562169

RESUMO

Many secretory tissues release Zn(II) ions along with other molecules in response to external stimuli. Here we demonstrate that secretion of Zn(II) ions from normal, healthy prostate tissue is stimulated by glucose in fasted mice and that release of Zn(II) can be monitored by MRI. An ∼50% increase in water proton signal enhancement is observed in T1-weighted images of the healthy mouse prostate after infusion of a Gd-based Zn(II) sensor and an i.p. bolus of glucose. Release of Zn(II) from intracellular stores was validated in human epithelial prostate cells in vitro and in surgically exposed prostate tissue in vivo using a Zn(II)-sensitive fluorescent probe known to bind to the extracellular surface of cells. Given the known differences in intracellular Zn(II) stores in healthy versus malignant prostate tissues, the Zn(II) sensor was then evaluated in a transgenic adenocarcinoma of the mouse prostate (TRAMP) model in vivo. The agent proved successful in detecting small malignant lesions as early as 11 wk of age, making this noninvasive MR imaging method potentially useful for identifying prostate cancer in situations where it may be difficult to detect using current multiparametric MRI protocols.


Assuntos
Meios de Contraste/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Zinco/metabolismo , Animais , Modelos Animais de Doenças , Corantes Fluorescentes , Humanos , Masculino , Camundongos , Próstata/diagnóstico por imagem , Próstata/metabolismo , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Zinco/química
11.
Magn Reson Med ; 80(4): 1402-1415, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29446127

RESUMO

PURPOSE: To develop a whole-body MRI technique at 3T with improved lesion conspicuity for metastatic cancer detection using fast, high-resolution and high SNR T2 -weighted (T2 W) imaging with simultaneous fat and fluid suppression. THEORY AND METHODS: The proposed dual-echo T2 -weighted acquisition for enhanced conspicuity of tumors (DETECT) acquires 4 images, in-phase (IP) and out-of-phase (OP) at a short and a long TE using single-shot turbo spin echo. The IP/OP images at the short and long TEs are reconstructed using the standard Dixon and shared-field-map Dixon reconstruction respectively, for robust fat-water separation. An adaptive complex subtraction between the 2 TE water-only images achieves fluid attenuation. DETECT imaging was optimized and evaluated in whole-body imaging of 5 healthy volunteers, and compared against diffusion-weighted imaging with background suppression (DWIBS) in 5 patients with known metastatic renal cell carcinoma. RESULTS: Robust fat-water separation and fluid attenuation were achieved using the shared-field-map Dixon reconstruction and adaptive complex subtraction, respectively. DETECT imaging technique generated co-registered T2 W images with and without fat suppression, heavily T2 W, and fat and fluid suppressed T2 W whole-body images in <7 min. Compared to DWIBS acquired in 17 min, the DETECT imaging achieved better detection and localization of lesions in patients with metastatic cancer. CONCLUSION: DETECT imaging technique generates T2 W images with high resolution, high SNR, minimal geometric distortions, and provides good lesion conspicuity with robust fat and fluid suppression in <7 min for whole-body imaging, demonstrating efficient and reliable metastatic cancer detection at 3T.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Renais , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Imagem Corporal Total/métodos , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Água Corporal/diagnóstico por imagem , Feminino , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
12.
AJR Am J Roentgenol ; 210(5): 1066-1072, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29489410

RESUMO

OBJECTIVE: The purpose of this study is to determine the reproducibility and diagnostic performance of a Likert scale in comparison with the European Society of Urogenital Radiology (ESUR) criteria and tumor-pseudocapsule contact length (TCL) for the detection of extraprostatic extension (EPE) at multiparametric MRI. MATERIALS AND METHODS: This was a retrospective review of all men who underwent multiparametric MRI followed by prostatectomy between November 2015 and July 2016. Multiparametric 3-T MRI studies with an endorectal coil were independently reviewed by five readers who assigned the likelihood of EPE using a 1-5 Likert score, ESUR criteria, and TCL (> 10 mm). EPE outcome (absent or present) for the index lesion at whole-mount histopathologic analysis was the standard of reference. Odds ratios (ORs) and areas under the ROC curve (Az) were used for diagnostic accuracy. The interreader agreement was determined using a weighted kappa coefficient. A p < 0.05 was considered significant. RESULTS: Eighty men met the eligibility criteria. At univariate analysis, the Likert score showed the strongest association (OR, 1.8) with EPE, followed by prostate-specific antigen level (OR, 1.7), ESUR score (OR, 1.6), and index lesion size (OR, 1.2). At multivariable analysis, higher Likert score (OR, 1.8) and prostate-specific antigen level (OR, 1.6-1.7) were independent predictors of EPE. The Az value for Likert scores was statistically significantly higher (0.79) than that for TCL (0.74; p < 0.01), but not statistically significantly higher than the value for ESUR scores (0.77; p = 0.17). Interreader agreement with Likert (κ = 0.52) and ESUR scores (κ = 0.55) was moderate and slightly superior to that for TCL (κ = 0.43). Except for TCL among inexperienced readers (κ = 0.34), reader experience did not affect interreader agreement. CONCLUSION: A Likert score conveying the degree of suspicion at multiparametric MRI is a stronger predictor of EPE than is either ESUR score or TCL and may facilitate informed decision making, patient counseling, and treatment planning.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/patologia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Invasividade Neoplásica , Prostatectomia , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
J Magn Reson Imaging ; 45(3): 908-916, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27442039

RESUMO

PURPOSE: To compare a simplified intravoxel incoherent motion (sIVIM) model to commonly used monoexponential and biexponential models in the characterization of prostate cancer (PCa) and noncancerous prostate tissues, and to investigate combinations of diffusion-weighted imaging (DWI) measures with dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI)-derived parameters in MRI-visible index lesions, to facilitate PCa risk stratification. MATERIALS AND METHODS: In this retrospective, Institutional Review Board (IRB)-approved study, 43 consecutive patients with PCa who had 3T MRI exams followed by radical prostatectomy were included. DWI and DCE parameters were measured from one index lesion per patient, and noncancerous central gland and peripheral zone. Logistic regression modeling was performed to select the optimal combination of DWI and DCE measurements for tumor risk assessment. RESULTS: All diffusion models showed the lowest diffusion coefficients in tumors, intermediate values in noncancerous central gland, and highest values in noncancerous peripheral zone (all P < 0.001). Ktrans and kep were higher in tumors compared to central gland (P < 0.005) and peripheral zone (P < 0.001). The initial area under the contrast concentration curve was higher in tumor than the peripheral zone (P < 0.001). The area under the receiver operating characteristic curve of the combined DWI and DCE parameters (0.78) was higher than its individual components (0.73 and 0.63, respectively) for discriminating low- and intermediate-to-high-risk tumors. CONCLUSION: The sIVIM model provided comparable results with fewer b-values and shorter image acquisition time. The combination of DWI and DCE measurements of MRI-visible index lesions improved the preoperative prostate cancer risk characterization compared to the individual parameters from either technique alone. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:908-916.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Compostos Organometálicos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Simulação por Computador , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Comput Assist Tomogr ; 41(1): 8-14, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27824670

RESUMO

This is the fourth of a series of 4 white papers that represent expert consensus documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography. This article, part 4, discusses DECT for abdominal and pelvic applications and, at the end of each, will offer our consensus opinions on the current clinical utility of the application and opportunities for further research.


Assuntos
Doenças do Sistema Digestório/diagnóstico por imagem , Doenças Urogenitais Femininas/diagnóstico por imagem , Doenças Urogenitais Masculinas/diagnóstico por imagem , Guias de Prática Clínica como Assunto/normas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Tomografia Computadorizada por Raios X/métodos , Medicina Baseada em Evidências , Feminino , Humanos , Internacionalidade , Masculino , Pelve/diagnóstico por imagem , Radiografia Abdominal/métodos
15.
J Urol ; 195(1): 80-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26192254

RESUMO

PURPOSE: We assess the performance of prospectively assigned magnetic resonance imaging based Likert scale scores for the detection of clinically significant prostate cancer, and analyze the pre-biopsy imaging variables associated with increased cancer detection using targeted magnetic resonance imaging-transrectal ultrasound fusion biopsy. MATERIALS AND METHODS: In this retrospective review of prospectively generated data including men with abnormal multiparametric prostate magnetic resonance imaging (at least 1 Likert score 3 or greater lesion) who underwent subsequent targeted magnetic resonance imaging-transrectal ultrasound fusion biopsy, we determined the association between different imaging variables (Likert score, lesion size, lesion location, prostate volume, radiologist experience) and targeted biopsy positivity rate. We also compared the detection of clinically significant cancer according to Likert scale scores. Tumors with high volume (50% or more of any core) Gleason score 3+4 or any tumor with greater Gleason score were considered clinically significant. Each lesion served as the elementary unit for analysis. We used logistic regression for univariate and multivariate (stepwise selection) analysis to assess for an association between targeted biopsy positivity rate and each tested variable. The relationship between Likert scale and Gleason score was evaluated using the Spearman correlation coefficient. RESULTS: A total of 161 men with 244 lesions met the study eligibility criteria. Targeted biopsies diagnosed cancer in 41% (66 of 161) of the men and 41% (99 of 244) of the lesions. The Likert score was the strongest predictor of targeted biopsy positivity (OR 3.7, p <0.0001). Other imaging findings associated with a higher targeted biopsy positivity rate included smaller prostate volume (OR 0.7, p <0.01), larger lesion size (OR 2.2, p <0.001) and anterior location (OR 2.0, p=0.01). On multiple logistic regression analysis Likert score, lesion size and prostate volume were significant predictors of targeted biopsy positivity. Higher Likert scores were also associated with increased detection of clinically significant tumors (p <0.0001). CONCLUSIONS: The Likert scale score used to convey the degree of suspicion on multiparametric magnetic resonance imaging is the strongest predictor of targeted biopsy positivity and of the presence of clinically significant tumor.


Assuntos
Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Adulto , Idoso , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Reto , Estudos Retrospectivos , Ultrassonografia
16.
J Comput Assist Tomogr ; 40(6): 841-845, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27841774

RESUMO

This is the first of a series of 4 white papers that represent Expert Consensus Documents developed by the Society of Computed Body Tomography and Magnetic Resonance through its task force on dual-energy computed tomography (DECT). This article, part 1, describes the fundamentals of the physical basis for DECT and the technology of DECT and proposes uniform nomenclature to account for differences in proprietary terms among manufacturers.


Assuntos
Guias de Prática Clínica como Assunto , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/normas , Terminologia como Assunto , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas , Biotecnologia/instrumentação , Biotecnologia/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Estados Unidos
17.
J Magn Reson Imaging ; 42(3): 545-65, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25975847

RESUMO

The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Animais , Encéfalo/patologia , Neoplasias Encefálicas/tratamento farmacológico , Colágeno/química , Meios de Contraste/síntese química , Difusão , Desenho de Fármacos , Fibrina/química , Gadolínio/química , Glioma/tratamento farmacológico , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Ligantes , Camundongos , Modelos Químicos , Ácido Pentético/química , Termodinâmica , Água/química
18.
J Magn Reson Imaging ; 41(5): 1383-93, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24943647

RESUMO

PURPOSE: To identify computer-extracted features for central gland and peripheral zone prostate cancer localization on multiparametric magnetic resonance imaging (MRI). MATERIALS AND METHODS: Preoperative T2-weighted (T2w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) MRI were acquired from 23 men with confirmed prostate cancer. Following radical prostatectomy, the cancer extent was delineated by a pathologist on ex vivo histology and mapped to MRI by nonlinear registration of histology and corresponding MRI slices. In all, 244 computer-extracted features were extracted from MRI, and principal component analysis (PCA) was employed to reduce the data dimensionality so that a generalizable classifier could be constructed. A novel variable importance on projection (VIP) measure for PCA (PCA-VIP) was leveraged to identify computer-extracted MRI features that discriminate between cancer and normal prostate, and these features were used to construct classifiers for cancer localization. RESULTS: Classifiers using features selected by PCA-VIP yielded an area under the curve (AUC) of 0.79 and 0.85 for peripheral zone and central gland tumors, respectively. For tumor localization in the central gland, T2w, DCE, and DWI MRI features contributed 71.6%, 18.1%, and 10.2%, respectively; for peripheral zone tumors T2w, DCE, and DWI MRI contributed 29.6%, 21.7%, and 48.7%, respectively. CONCLUSION: PCA-VIP identified relatively stable subsets of MRI features that performed well in localizing prostate cancer on MRI.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Neoplasias da Próstata/patologia , Idoso , Interpretação Estatística de Dados , Humanos , Aumento da Imagem/métodos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
AJR Am J Roentgenol ; 205(3): 469-78, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26295633

RESUMO

OBJECTIVE: The purpose of this study was to determine the incidence of nephrogenic systemic fibrosis (NSF) in patients with chronic kidney disease (CKD) and moderate-to-severe impairment of kidney function who had not previously been exposed to gadolinium-based contrast agents (GBCAs) or referred to undergo contrast-enhanced MRI with gadobenate dimeglumine or gadoteridol. SUBJECTS AND METHODS: Two multicenter prospective cohort studies evaluated the incidence of unconfounded NSF in patients with stage 3 CKD (estimated glomerular filtration rate [eGFR] in cohort 1, 30-59 mL/min/1.73 m(2)) or stage 4 or 5 CKD (eGFR in cohort 2, < 30 mL/min/1.73 m(2)) after injection of gadobenate dimeglumine (study A) or gadoteridol (study B). A third study (study C) determined the incidence of NSF in patients with stage 4 or 5 CKD who had not received a GBCA in the 10 years before enrollment. Monitoring for signs and symptoms suggestive of NSF was performed via telephone at 1, 3, 6, and 18 months, with clinic visits occurring at 1 and 2 years. RESULTS: For studies A and B, the populations evaluated for NSF comprised 363 and 171 patients, respectively, with 318 and 159 patients in cohort 1 of each study, respectively, and with 45 and 12 patients in cohort 2, respectively. No signs or symptoms of NSF were reported or detected during the 2 years of patient monitoring. Likewise, no cases of NSF were reported for any of the 405 subjects enrolled in study C. CONCLUSION: To our knowledge, and consistent with reports in the literature, no association of gadobenate dimeglumine or gadoteridol with unconfounded cases of NSF has yet been established. Study data confirm that both gadoteridol and gadobenate dimeglumine properly belong to the class of GBCAs considered to be associated with the lowest risk of NSF.


Assuntos
Meios de Contraste/efeitos adversos , Compostos Heterocíclicos/efeitos adversos , Falência Renal Crônica/complicações , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Dermopatia Fibrosante Nefrogênica/induzido quimicamente , Compostos Organometálicos/efeitos adversos , Adolescente , Adulto , Idoso , Feminino , Gadolínio/efeitos adversos , Humanos , Testes de Função Renal , Masculino , Meglumina/efeitos adversos , Pessoa de Meia-Idade , Dermopatia Fibrosante Nefrogênica/epidemiologia , Vigilância de Produtos Comercializados , Estudos Prospectivos , Fatores de Risco
20.
Radiographics ; 35(3): 696-708, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25786055

RESUMO

Cancer of the prostate gland is a common but heterogeneous disease requiring individualized risk stratification for optimal clinical management. However, transrectal ultrasonography (US)-guided biopsy-the standard of care for diagnosis of prostate cancer-frequently fails to detect aggressive tumors or provide reliable parameters for pretreatment risk stratification. Multiparametric magnetic resonance (MR) imaging is the most accurate imaging technique for prostate cancer detection and local staging. Recently, different approaches have been developed to allow targeted biopsies of areas that are suspicious for cancer at MR imaging, including direct MR imaging guidance and MR imaging-transrectal US fusion, which can be achieved with cognitive fusion or software assistance. Regardless of the technique used, targeted prostate biopsies have the potential to increase detection of clinically relevant prostate cancer and provide more reliable risk stratification in patients with known cancer. The authors discuss the shortcomings of traditional diagnostic workup for prostate cancer, the rationale for targeted prostate biopsies, the different techniques available for targeting suspicious areas seen at MR imaging, and the clinical contexts in which targeted prostate biopsies might be useful. In addition, they discuss opportunities and challenges associated with MR imaging-transrectal US fusion biopsy, as well as questions that need to be addressed before formal incorporation of this technique into practice guidelines.


Assuntos
Biópsia Guiada por Imagem , Imagem por Ressonância Magnética Intervencionista , Imagem Multimodal , Neoplasias da Próstata/patologia , Ultrassonografia de Intervenção , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Reto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA