1.
Ultraschall Med ; 37(6): 619-626, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27300274

RESUMO

Purpose: To investigate the spectrum, applicability and diagnostic capacity of intravenous contrast-enhanced ultrasound imaging (CEUS) in a pediatric population. Materials and Methods: From 08/2005 to 11/2015, n = 40 pediatric patients and young adults from 0 - 26 years (Ø 11.4 ±â€Š7.5) and 3.0 - 85.3 kg (Ø 40.8 ± 25.6) with n = 55 investigations received n = 79 IV applications of ultrasound contrast agent (UCA). UCA dose and side effects were documented. Scanned organs were the liver (n = 42), spleen (n = 9), kidney (n = 3), and testis (n = 1). Histology, surgery or reference imaging was compared to CEUS and clinical follow-up. Results: The UCA dose < 20 kg was 0.4 ±â€Š0.3 ml, (0.05 ±â€Š0.02 ml/kg) and > 20 kg was 1.0 ±â€Š0.4 ml (p< 0.0001) (0.02 ±â€Š0.01 ml/kg, p< 0.0001). Adverse effects occurred in 2/79 applications (2.5 %). Agreement CEUS/gold standard resulted in 32/34 investigations. For liver diagnostics (gold standard: MRI, CT, histology, serology), n = 11 malignant and n = 15 benign focal liver lesions were included. The specificity was 100 % (95 % CI: 0.77 - 1.00), the sensitivity was 82 % (95 % CI: 0.48 - 0.98), the positive predictive value was 100 % (95 % CI: 0.69 - 1.00) and the negative predictive value was 88 % (95 % CI: 0.62 - 0.98, p< 0.0001). In n = 2 reference imaging misdiagnosed and CEUS was in accordance with clinical follow-up. All splenic/renal lesions were diagnosed correctly. In n = 1 an insufficient testicular perfusion was ruled out. The observation time was 30.4 ±â€Š30.5 months. Conclusion: CEUS is a well-tolerated and diagnostically equivalent modality in pediatric care, providing fundamental advantages compared to currently approved imaging modalities for these age groups.


Assuntos
Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Baço/diagnóstico por imagem , Testículo/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Meios de Contraste/efeitos adversos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
2.
Radiat Environ Biophys ; 54(1): 1-12, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25567615

RESUMO

The aim of this cohort study was to assess the risk of developing cancer, specifically leukaemia, tumours of the central nervous system and lymphoma, before the age of 15 years in children previously exposed to computed tomography (CT) in Germany. Data for children with at least one CT between 1980 and 2010 were abstracted from 20 hospitals. Cancer cases occurring between 1980 and 2010 were identified by stochastic linkage with the German Childhood Cancer Registry (GCCR). For all cases and a sample of non-cases, radiology reports were reviewed to assess the underlying medical conditions at time of the CT. Cases were only included if diagnosis occurred at least 2 years after the first CT and no signs of cancer were recorded in the radiology reports. Standardised incidence ratios (SIR) using incidence rates from the general population were estimated. The cohort included information on 71,073 CT examinations in 44,584 children contributing 161,407 person-years at risk with 46 cases initially identified through linkage with the GCCR. Seven cases had to be excluded due to signs possibly suggestive of cancer at the time of first CT. Overall, more cancer cases were observed (O) than expected (E), but this was mainly driven by unexpected and possibly biased results for lymphomas. For leukaemia, the SIR (SIR = O/E) was 1.72 (95 % CI 0.89-3.01, O = 12), and for CNS tumours, the SIR was 1.35 (95 % CI 0.54-2.78, O = 7). Despite careful examination of the medical information, confounding by indication or reverse causation cannot be ruled out completely and may explain parts of the excess. Furthermore, the CT exposure may have been underestimated as only data from the participating clinics were available. This should be taken into account when interpreting risk estimates.


Assuntos
Neoplasias Induzidas por Radiação/epidemiologia , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Radiação Ionizante , Risco
3.
Eur J Neurol ; 20(9): 1292-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23663558

RESUMO

BACKGROUND AND PURPOSE: Isolated optic neuritis (ON) is frequently the initial symptom of multiple sclerosis (MS). The aim of our study was to investigate the risk of conversion to MS in children following isolated ON and to evaluate the performance of current diagnostic methods such as cranial magnetic resonance imaging (cMRI), visual evoked potentials (VEPs) and oligoclonal bands in spinal fluid (OCB) as predictive factors for MS development. METHODS: Medical records of 159 patients presenting with acute ON between 2000 and 2010 at the Department of Pediatrics, University of Erlangen, were screened; 34 patients with isolated ON were identified. Progression to MS was defined according to the revised McDonald criteria 2005. Age, sex, VEPs, ON type, cMRI, OCB and visual recovery were assessed as predictors of progression to MS using simple logistic regressions. A multiple logistic regression model included variables found to be significant in univariate analyses. RESULTS: Abnormal cMRI was associated with an increase in the odds of MS development (odds ratio 20.57; 95% CI 2.16-196.10, P < 0.001), as was positive OCB (odds ratio 12.0; 95% CI 1.29-111.32, P = 0.001). However, only cMRI remained statistically significant in multiple regressions. CONCLUSIONS: Multiple sclerosis-like cMRI lesions and OCB are suitable for assessing the risk of progression to MS following isolated ON, as children with both cMRI abnormalities and positive OCB at onset of ON are at high risk of developing MS.


Assuntos
Encéfalo/patologia , Potenciais Evocados Visuais/fisiologia , Bandas Oligoclonais , Neurite Óptica/líquido cefalorraquidiano , Neurite Óptica/patologia , Adolescente , Criança , Pré-Escolar , Progressão da Doença , Feminino , Humanos , Modelos Logísticos , Imageamento por Ressonância Magnética , Masculino , Esclerose Múltipla/líquido cefalorraquidiano , Esclerose Múltipla/patologia , Bandas Oligoclonais/líquido cefalorraquidiano
4.
Klin Padiatr ; 224(3): 170-3, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22513792

RESUMO

Malignant peritoneal mesothelioma is extremely rarely seen in young patients.A 16 year-old girl presented with appendicitis-like acute abdominal pain. Intra-operatively, multiple confluent peritoneal nodules were seen on the entire greater omentum and in the pelvis infiltrating the uterus and both ovaries. Biopsies were obtained and interpreted as serous ovarian carcinoma. Radical surgical resection and hyperthermic intraperitoneal chemotherapy -(HIPEC) with carboplatin was performed and followed by 2 cycles of carboplatin/paclitaxel. Histological reevaluation showed characteristic features of epithelioid peritoneal mesothelioma and ruled out serous ovarian cancer. Therapy was continued with 6 cycles of pemetrexed/cisplatin.3 months after end of chemotherapy vital tumor tissue was found in the recess behind the liver, which could be resected completely. The patient is currently disease-free 17 months after initial diagnosis.Malignant peritoneal mesothelioma in young female patients might be under-recognized and possibly misdiagnosed as ovarian serous carcinoma in some cases. International and interdisciplinary cooperation is necessary in order to provide evidence based guidelines for diagnosis and treatment in the future.


Assuntos
Mesotelioma/diagnóstico , Neoplasias Peritoneais/diagnóstico , Doenças Raras , Dor Abdominal/etiologia , Adolescente , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carboplatina/administração & dosagem , Quimioterapia Adjuvante , Quimioterapia do Câncer por Perfusão Regional , Terapia Combinada , Diagnóstico Diferencial , Feminino , Humanos , Mesotelioma/tratamento farmacológico , Mesotelioma/patologia , Mesotelioma/cirurgia , Paclitaxel/administração & dosagem , Neoplasias Peritoneais/tratamento farmacológico , Neoplasias Peritoneais/patologia , Neoplasias Peritoneais/cirurgia
6.
Ophthalmologe ; 114(8): 741-744, 2017 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-27730295

RESUMO

Amusement park injuries have become more common in recent years. Especially neurological symptoms dominate clinical findings. In this article, the case of a 15-year-old child with homonymous hemianopia due to an atypical intracranial bleeding with subdural hematoma after a giant swing ride is described for the first time.


Assuntos
Aceleração/efeitos adversos , Hematoma Subdural/etiologia , Hemianopsia/etiologia , Hemorragia Intracraniana Traumática/etiologia , Atividades de Lazer , Parques Recreativos , Adolescente , Angiografia Digital , Feminino , Seguimentos , Hematoma Subdural/diagnóstico , Hemianopsia/diagnóstico , Humanos , Hemorragia Intracraniana Traumática/diagnóstico , Imageamento por Ressonância Magnética , Lobo Occipital/patologia , Remissão Espontânea , Testes de Campo Visual
7.
Ophthalmologe ; 114(5): 457-461, 2017 May.
Artigo em Alemão | MEDLINE | ID: mdl-27401467

RESUMO

Complications of acute bacterial sinusitis mostly occur in children and adolescents. In particular, intracranial spread of the infection can lead to severe even fatal courses of the disease. This article is a case report about a 13-year-old boy suffering from left-sided headache, meningismus and exophthalmos as presenting symptoms. Cranial magnetic resonance imaging (MRI) showed merely right-sided sphenoid sinusitis; however, the diffusion-weighted MRI sequence indicated a left-sided cavernous sinus thrombosis, which could be confirmed by computed tomography (CT) angiography. Cerebrospinal fluid diagnostics showed significant leukocytosis confirming secondary meningitis. Finally, exophthalmos was explained by parainfectious cavernous sinus thrombosis and periorbital edema. This case report highlights the importance of extended and specific diagnostic imaging in cases of clinically suspected complications in children and adolescents with sinusitis and the diagnostic significance of diffusion-weighted MRI.


Assuntos
Trombose do Corpo Cavernoso/diagnóstico , Trombose do Corpo Cavernoso/terapia , Exoftalmia/diagnóstico , Exoftalmia/terapia , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Trombose do Corpo Cavernoso/complicações , Diagnóstico Diferencial , Exoftalmia/etiologia , Humanos , Masculino , Doenças Raras/complicações , Doenças Raras/diagnóstico , Resultado do Tratamento
8.
Rofo ; 188(2): 179-87, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26815121

RESUMO

PURPOSE: To assess fields of application and value of dual source computed tomography (DSCT) for diagnostics and therapy in patients with congenital heart disease during their first year of life. Evaluation of image quality, surgical use and radiation exposure of 2nd and 3 rd generation DSCT. MATERIALS AND METHODS: DSCT was applied in 118 cases between January 2012 and October 2014 for diagnostics of congenital heart defects. 2nd generation was used in 91 cases until April 2014 and 3 rd generation in 27 cases during the period thereafter. 3 D reconstructions of the image data were created for clinical diagnostics and planning of interventions. Image quality was assessed using a 4-point-scale. The visibility of the mammary arteries was analyzed, and signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. The usefulness of 3D-reconstructions for surgical planning was rated using a 5-point-scale. Radiation exposure and contrast dye consumption were determined. All cases were analyzed retrospectively. RESULTS: DSCT was successfully used in 118 cases. All image data obtained were interpretable. More than 60 percent of cases did not show any artifacts. The mammary arteries were visible down to the diaphragmatic arch in more than 80 percent of cases. Diagnostic value and surgical benefit were evaluated as "useful" or as "essential" in all cases. Median radiation dose was 0.4 mSv and 0.27 mSv for the 2nd and 3 rd generation DSCT, respectively. Consumption of contrast dye was 2 ml/kg in all cases. CONCLUSION: DSCT is a modern and extremely helpful technique for diagnostics and planning of interventions in patients with complex congenital heart defects. Extracardiac vascular structures in particular can be depicted three-dimensionally at high resolution. The use of iterative reconstruction with 3 rd generation DSCT yielded image quality similar to that of 2nd generation DSCT at considerably reduced radiation exposure level compared to 2nd generation DSCT. 3 rd generation DSCT is a low risk, accurate and extremely fast technique for diagnosing unstable patients with CHD. KEY POINTS: Expanded scope of indications for DSCT in diagnosing critically ill infants. Effective radiation dose is considerably lower than 0.5 mSv. Extremely rapid image acquisitions with high image quality. Possibility of optimized 3D-based surgical planning


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Artefatos , Desenho de Equipamento , Feminino , Cardiopatias Congênitas/terapia , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Rofo ; 187(12): 1099-107, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26327669

RESUMO

PURPOSE: To evaluate automated segmentation and the effects of different manual adjustments regarding left ventricular parameter quantification in cardiac magnetic resonance (MR) data on children and adolescents who have undergone surgical repair of right-sided congenital heart disease (CHD). MATERIALS AND METHODS: Dedicated software (syngo.via, Siemens AG) was used to automatically segment and/or manually adjust the end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), myocardial mass (MM) and ejection fraction (EF) before/after manual apex/base adjustment (ADJ-step 1) and after manual apex/base/myocardial contour adjustment (ADJ-step 2; reference standard). MR data of 40 patients (13.1 ± 3. y, 4 - 17 y) with repaired CHD with decreased pulmonary blood flow (CHD-DPBF) were evaluated. Intra- and inter-rater reliability was determined for 10 randomly selected patients. RESULTS: The software correctly detected the left ventricle in 38/40 (95%) patients. EDV after automated segmentation: 119.1 ± 44.0 ml; after ADJ-step 1: 115.8 ± 9.5 ml; after ADJ-step 2: 116.2 ± 39.4 ml. The corresponding results for ESV were 52.0 ± 18.5/49.6 ± 6.9/49.7 ± 16.4 ml; for SV 67.1 ± 28.5/66.2 ± 25.4/66.5 ± 25. ml; for EF 55.5 ± 7.3/56.7 ± 6.6/56.7 ± 6.3%; for MM 83.7 ± 35.9/76.2 ± 8.3/74.6 ± 27.2 g. Significant differences were found for ESV/MM/EF comparing the automated segmentation results with these after ADJ-step 1 and ADJ-step 2. No significant differences were found when comparing all results of ADJ-step 1 and ADJ-step 2 or when comparing EDV/SV results. Intra- and inter-rater reliability was excellent. The mean time effort was 63.4 ± 6.9 s for the automated segmentation, 74.2 ± 8.9 s for ADJ-step 1 and 269.5 ± 39.4 s for ADJ-step 2. CONCLUSION: Automated left ventricular volumes and function analysis in children and adolescents with surgically treated CHD proved to be feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provided clinically acceptable results. KEY POINTS: Automated left ventricular volume and function analysis in children and adolescents with surgically treated right-sided heart disease is feasible with excellent intra- and inter-rater reliability. Automated segmentation with manual apex/base adjustment provides clinically acceptable results. Additional manual myocardial contour adjustment does not significantly improve the results.


Assuntos
Volume Cardíaco/fisiologia , Meios de Contraste , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico , Humanos , Masculino , Miocárdio/patologia , Estudos Retrospectivos , Software , Disfunção Ventricular Esquerda/fisiopatologia
10.
Int Angiol ; 12(2): 152-61, 1993 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8370997

RESUMO

We report on a study which has been performed during two consecutive time intervals on patients with complicated arterial obliterations, who were treated with percutaneous endoprostheses in order to stabilize the results obtained by the preceding balloon angioplasty. Eighty patients participated at this study, and 136 stents were implanted. A detailed analysis of the reocclusions respectively the stenoses shows that the precise placement of the stents and also the length of the stent in relation to the lesion is of utmost importance, in order to avoid reocclusions. The Strecker stents were lege artis placed in both time groups, and the increased occurrence of reocclusions, especially in the femoropopliteal region, was mainly due to the fact that only one stent length was available. Restenoses in the second group are, thus, considerably lower between 6 and 12 months, as the use of an adequate stent length was possible by then. The medical supplementary treatment of lege artis placed stents in the iliac arteries has no additional influence on the patency rate, while the medication with anticoagulants seems to have a rather positive effect on the patency rate in the femoro-popliteal region. The results, which have been obtained up to now, show that definite improvements are to be achieved by the use of stents, provided that their indication is being handled with utmost care.


Assuntos
Arteriopatias Oclusivas/terapia , Artéria Femoral , Artéria Ilíaca , Doenças Vasculares Periféricas/terapia , Stents , Arteriopatias Oclusivas/epidemiologia , Aspirina/uso terapêutico , Feminino , Seguimentos , Heparina/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/epidemiologia , Recidiva , Grau de Desobstrução Vascular/fisiologia
11.
Rofo ; 185(5): 446-53, 2013 May.
Artigo em Alemão | MEDLINE | ID: mdl-23494504

RESUMO

PURPOSE: In this study the use of flat detector computed tomography (FD-CT) in the catheterization of patients with congenital heart disease was evaluated. Application reports were created for various issues based on the achieved image quality in diverse anatomical regions. MATERIALS AND METHODS: FD-CT was applied in 176 cases during catheterization between January 2010 and April 2012. A five-point Likert scale ("essential" to "misleading") was used to evaluate image quality. All cases were analyzed retrospectively and application reports for the visualization of the aorta, pulmonary arteries, pulmonary veins, semilunar valves, cavopulmonary connections and atrial baffles were generated. Contrast dye consumption and radiation dose were evaluated. RESULTS: During the observation period FD-CT was applied in all 176 cases. The mean patient age was 7.0 years (0.01 - 42.53 years). The clinical value of FD-CT was rated superior to conventional angiography in 96.6 % of the cases and was never rated as "misleading". FD-CT was rated "essential" in 3.4 % of all cases, "very useful" in 77.3 % of all cases, "useful" in 15.9 % of all cases and "not useful" in 3.4 % of all cases. The mean dose-area product was 99 µGym2 (19.3 - 1276.6 µGym2), and the used contrast dye was 1.76 ml/kg (0.9 - 5 ml/kg). Application reports for the visualization of different anatomical regions are demonstrated. CONCLUSION: FD-CT is a new and auxiliary procedure in diagnostic and interventional catheterization of patients with congenital heart disease. Particularly extracardiac structures can be displayed in three-dimensional high resolution and be used for diagnosis, surgical planning and 3 D navigation.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/epidemiologia , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/estatística & dados numéricos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Ecrans Intensificadores para Raios X/estatística & dados numéricos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Alemanha/epidemiologia , Humanos , Lactente , Recém-Nascido , Masculino , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
12.
Zentralbl Chir ; 132(2): 118-23, 2007 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-17516317

RESUMO

INTRODUCTION: Harmonic Imaging (HI) is a new Ultrasound (US) modality with high contrast and spatial resolution. Aim of this study was to compare fundamental imaging (FI) and HI in the diagnosis of appendicitis. PATIENTS AND METHODS: In 50 children (male : female, 25 : 25; mean age: 9.9 years) prior to an appendectomy US of the right lower quadrant was performed in both FI and HI (Tissue Harmonic Imaging - THI - Sonoline Elegra, Siemens, 7.5 MHz linear). The images were compared with respect to delineation of surrounding, contour, wall and content of the appendix. RESULTS: In 43 / 50 (86 %) patients diagnosis of appendicitis was confirmed histologically (sensitivity 98 %, specificity 94 %). In 37 / 43 patients the appendix was depicted using FI. With HI this number was 40 / 43. HI was significantly better in delineating the contour, wall, mucosa and content of the appendix (p < 0.01). HI also exceeded in demonstrating free fluid, mesenterial lymph nodes and surrounding echogenicity. CONCLUSION: HI of appendicitis provides images with significantly better quality than FI. When both imaging options are available harmonic imaging modality should be the preferred choice for scanning the appendix.


Assuntos
Apendicite/diagnóstico por imagem , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Adolescente , Apendicectomia , Apendicite/patologia , Apendicite/cirurgia , Apêndice/patologia , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade
13.
Bildgebung ; 60(4): 297-300, 1993 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-8118204

RESUMO

To verify the suspected diagnosis of deep thrombosis in the pelvic and/or the leg veins or to clarify the causes of pulmonary embolism, 84 patients were examined prospectively by color-coded duplex-sonography. The findings in the 103 legs examined were subsequently compared to those of an ascending phlebography. The deep veins from the region of the vena iliaca communis down to the lower leg were visualized, and blood flow, lumen and compressibility were checked. This procedure enabled the identification of totally occluding thrombi as well as partial thrombi with the circumfluent blood. The sensitivity of thrombus identification was 92.9%, the specificity was about 97% in the different segments. The results show that color-coded duplex sonography is a sensitive diagnostic instrument for follow-up in conservative therapy. Also, in postthrombotic changes, fresh clots can be identified for the most part. Color-coded duplex sonography can replace phlebography in most cases, if special attention is paid to regions which are difficult to visualize, such as the pelvic veins, the Hunter's channel and the veins of the lower leg.


Assuntos
Flebografia , Embolia Pulmonar/diagnóstico por imagem , Tromboflebite/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemodinâmica/fisiologia , Humanos , Perna (Membro)/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA