Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur Radiol ; 30(8): 4262-4271, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32219507

RESUMO

OBJECTIVES: To assess the discriminatory power of lexicon terms used in PI-RADS version 2 to describe MRI features of prostate lesions. METHODS: Four hundred fifty-four patients were included in this retrospective, institutional review board-approved study. Patients received multiparametric (mp) MRI and subsequent prostate biopsy including MRI/transrectal ultrasound fusion biopsy and 10-core systematic biopsy. PI-RADS lexicon terms describing lesion characteristics on mpMRI were assigned to lesions by experienced readers. Positive and negative predictive values (PPV, NPV) of each lexicon term were assessed using biopsy results as a reference standard. RESULTS: From a total of 501 lesions, clinically significant prostate cancer (csPCa) was present in 175 lesions (34.9%). Terms related to findings of restricted diffusion showed PPVs of up to 52.0%/43.9% and NPV of up to 91.8%/89.7% (peripheral zone or PZ/transition zone or TZ). T2-weighted imaging (T2W)-related terms showed a wide range of predictive values. For PZ lesions, high PPVs were found for "markedly hypointense," "lenticular," "lobulated," and "spiculated" (PPVs between 67.2 and 56.7%). For TZ lesions, high PPVs were found for "water-drop-shaped" and "erased charcoal sign" (78.6% and 61.0%). The terms "encapsulated," "organized chaos," and "linear" showed to be good predictors for benignity with distinctively low PPVs between 5.4 and 6.9%. Most T2WI-related terms showed improved predictive values for TZ lesions when combined with DWI-related findings. CONCLUSIONS: Lexicon terms with high discriminatory power were identified (e.g., "markedly hypointense," "water-drop-shaped," "organized chaos"). DWI-related terms can be useful for excluding TZ cancer. Combining T2WI- with DWI findings in TZ lesions markedly improved predictive values. KEY POINTS: • Lexicon terms describing morphological and functional features of prostate lesions on MRI show a wide range of predictive values for prostate cancer. • Some T2-related terms have favorable PPVs, e.g., "water-drop-shaped" and "organized chaos" while others show less distinctive predictive values. DWI-related terms have noticeable negative predictive values in TZ lesions making DWI feature a useful tool for exclusion of TZ cancer. • Combining DWI- and T2-related lexicon terms for assessment of TZ lesions markedly improves PPVs. Most T2-related lexicon terms showed a significant decrease in PPV when combined with negative findings for "DW hyperintensity."


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Terminologia como Assunto , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Biópsia Guiada por Imagem , Idioma , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata/patologia , Radiologia , Estudos Retrospectivos , Ultrassonografia
2.
Acta Radiol ; 59(6): 688-693, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28949259

RESUMO

Background Several interventional procedures show a dependency on fluoroscopy times (FT) and level of training. Furthermore, FT and dose area products (DAP) vary depending on access site and target vessel for chest port implantations, but not for other thoracic interventions such as percutaneous coronary interventions. Purpose To evaluate the influence of the combination of venous access site and level of training on FTs and DAPs during peripherally inserted central catheters (PICC) implantations in a large cohort of patients. Material and Methods In this retrospective study, PICC implantations of 681 consecutive patients (385 women, 296 men; mean age = 55.0 ± 16.7 years) were analyzed. Two groups of junior (< 50 interventions) and senior (≥ 50 implantations) radiologists were investigated in respect to FT and DAP during PICC placement procedures. Statistical analysis included the Mann-Whitney U test and the Kruskal-Wallis test. P values < 0.05 were considered significant. Results Senior radiologists required significantly less FT (senior = 0.43 s, junior = 0.53 s, P = 0.041), but there was no significant difference in DAPs (senior = 56.3 µGy*m2, junior = 60.6 µGy*m2, P = 0.151). PICC implantations through the left side resulted in a significant reduction of the median FT by 60.9% (left = 0.45 s, right = 1.15 s, P = 0.010). Conclusion Due to considerable dose reduction, the left-sided puncture, especially via the basilic and brachial veins, performed by well-trained interventional radiologists seem to be the preferable approach for PICCs.


Assuntos
Cateterismo Venoso Central/métodos , Cateterismo Periférico , Competência Clínica , Fluoroscopia , Exposição à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Doses de Radiação , Estudos Retrospectivos
3.
Acta Radiol ; 59(11): 1316-1325, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29430936

RESUMO

Background Endovascular aneurysm repair (EVAR) requires lifelong surveillance by computed tomography angiography (CTA). This is attended by a substantial accumulation of radiation exposure. Iterative reconstruction (IR) has been introduced to approach dose reduction. Purpose To evaluate adaptive statistical iterative reconstruction (ASIR) at different levels of tube voltage concerning image quality and dose reduction potential in follow-up post EVAR. Material and Methods One hundred CTAs in 67 patients with EVAR were examined using five protocols: protocol A (n = 40) as biphasic standard using filtered back projection (FBP) at 120 kV; protocols B (n = 40), C (n = 10), and D1 (n = 5) biphasic using ASIR at 120, 100, and 80 kV, respectively; and protocol D2 (n = 5) with a monophasic splitbolus ASIR protocol at 80 kV. Image quality was assessed quantitatively and qualitatively. Applied doses were determined. Results Applied doses in ASIR protocols were significantly lower than FBP standard (up to 75%). Compared to protocol A, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (e.g. arterial CNR intra-/extra-stent lumen: A = 35.4 ± 13.5, B = 34.2 ± 10.0, C = 29.6 ± 6.8, D1 = 32.1 ± 6.3, D2 = 40.8 ± 23.1) in protocol B were equal and in protocols C and D equal to partially inferior, however not decisive for diagnostic quality. Subjective image quality ratings in all protocols were good to excellent without impairments of diagnostic confidence (A-D2: 5), with high inter-rater agreement (60-100%). Conclusion ASIR contributes to significant dose reduction without decisive impairments of image quality and diagnostic confidence. We recommend an adapted follow-up introducing ASIR and combined low-kV in the long-term surveillance after EVAR.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Procedimentos Endovasculares/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Idoso , Aorta Abdominal/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
4.
Acta Radiol ; 58(12): 1468-1475, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28406048

RESUMO

Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.


Assuntos
Cateterismo Venoso Central/economia , Cateterismo Venoso Central/métodos , Análise Custo-Benefício/economia , Curva de Aprendizado , Serviço Hospitalar de Radiologia/economia , Radiologia/educação , Cateterismo Venoso Central/instrumentação , Cateteres Venosos Centrais/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/economia , Estudos Retrospectivos , Fatores de Tempo
5.
In Vivo ; 32(1): 179-184, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29275317

RESUMO

BACKGROUND: Totally implantable central venous port systems provide a safe and effective, long-term means of access for administration of hyperosmolar, local irritant medication, such as chemotherapy, antibiotics and parenteral nutrition. AIM: To evaluate the combination of access site and level of experience on fluoroscopy times (FT) and dose area products (DAP) during implantation of port catheters in a large patient population. MATERIALS AND METHODS: A total of 1,870 patients (992 women, 878 men; age: 61±13.14 years) were reviewed investigating two groups of junior (≤50 implantations) and senior (>50) radiologists. RESULTS: Senior radiologists required less FT/DAP (0.24 s/57.3 µGy m2 versus 0.43 s/68.2 µGy m2, respectively; p<0.001). Right jugular vein access required the least FT/DAP (0.25 s/56.15 µGy m2) and right-sided implantation lower FT/DAP (right: 0.26 s/56.4 µGy m2, left: 0.40 s/85.10 µGy m2, p<0.001). CONCLUSION: Due to DAP/FT reductions, the right jugular vein seems to be the most favorable implantation side for port systems. For further dose reduction, residents should be well-trained.


Assuntos
Cateterismo Venoso Central/métodos , Cateteres de Demora , Fluoroscopia/métodos , Veias Jugulares , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Doses de Radiação , Exposição à Radiação , Estudos Retrospectivos , Fatores de Tempo
6.
Rofo ; 189(9): 844-854, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28651263

RESUMO

Purpose As a supra-regional level-I trauma center, we evaluated computed tomography (CT) acquisitions of polytraumatized patients for quality and dose optimization purposes. Adapted statistical iterative reconstruction [(AS)IR] levels, tube voltage reduction as well as a split-bolus contrast agent (CA) protocol were applied. Materials and Methods 61 patients were split into 3 different groups that differed with respect to tube voltage (120 - 140 kVp) and level of applied ASIR reconstruction (ASIR 20 - 50 %). The CT protocol included a native acquisition of the head followed by a single contrast-enhanced acquisition of the whole body (64-MSCT). CA (350 mg/ml iodine) was administered as a split bolus injection of 100 ml (2 ml/s), 20 ml NaCl (1 ml/s), 60 ml (4 ml/s), 40 ml NaCl (4 ml/s) with a scan delay of 85 s to detect injuries of both the arterial system and parenchymal organs in a single acquisition. Both the quantitative (SNR/CNR) and qualitative (5-point Likert scale) image quality was evaluated in parenchymal organs that are often injured in trauma patients. Radiation exposure was assessed. Results The use of IR combined with a reduction of tube voltage resulted in good qualitative and quantitative image quality and a significant reduction in radiation exposure of more than 40 % (DLP 1087 vs. 647 mGyxcm). Image quality could be improved due to a dedicated protocol that included different levels of IR adapted to different slice thicknesses, kernels and the examined area for the evaluation of head, lung, body and bone injury patterns. In synopsis of our results, we recommend the implementation of a polytrauma protocol with a tube voltage of 120 kVp and the following IR levels: cCT 5mm: ASIR 20; cCT 0.625 mm: ASIR 40; lung 2.5 mm: ASIR 30, body 5 mm: ASIR 40; body 1.25 mm: ASIR 50; body 0.625 mm: ASIR 0. Conclusion A dedicated adaptation of the CT trauma protocol (level of reduction of tube voltage and of IR) according to the examined body region (head, lung, body, bone) combined with a split bolus CA injection protocol allows for a high-quality CT examination and a relevant reduction of radiation exposure in the examination of polytraumatized patients Key Points · Dedicated adaption of the CT trauma protocol allows for an optimized examination.. · Different levels of iterative reconstruction, tube voltage and the CA injection protocol are crucial.. · A reduction of radiation exposure of more than 40 % with good image quality is possible.. Citation Format · Kahn J, Kaul D, Böning G et al. Quality and Dose Optimized CT Trauma Protocol - Recommendation from a University Level-I Trauma Center. Fortschr Röntgenstr 2017; 189: 844 - 854.


Assuntos
Traumatismo Múltiplo/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/normas , Imagem Corporal Total/normas , Centros Médicos Acadêmicos/normas , Algoritmos , Humanos , Pessoa de Meia-Idade , Melhoria de Qualidade/normas , Doses de Radiação , Exposição à Radiação/normas , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Centros de Traumatologia/normas
7.
J Investig Med High Impact Case Rep ; 3(1): 2324709615576988, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26425636

RESUMO

Autoimmune pancreatitis is a rare type of chronic pancreatitis. It is supposed to be a pancreatic manifestation of an immune-complex modulated systemic disorder. In contrast, pancreatic adenocarcinoma is the most frequent malignant neoplasm of the pancreas. Within the rare type of focal autoimmune pancreatitis, only few presentations with multifocal pancreatic lesions have been described. Herein we report a case of a 58-year-old patient with autoimmune pancreatitis presenting with bifocal manifestations of the pancreatic head and tail, mimicking pancreatic adenocarcinoma clinically, on computed tomography and magnetic resonance imaging. Typical imaging findings of autoimmune pancreatitis are compared with typical findings in pancreatic carcinoma. The diagnostic dilemma of differentiating between both entities is discussed. A review of the present literature regarding multifocal presence of autoimmune pancreatitis is performed.

8.
Eur J Radiol ; 83(8): 1332-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24894696

RESUMO

PURPOSE: To assess ASIR (adaptive statistical iterative reconstruction) technique regarding dose reduction and its impact on image quality in evaluation CTs of potential kidney donors. MATERIALS AND METHODS: Between May and November 2013, a prospective study of 53 assumingly healthy potential kidney donors was conducted. The subjects underwent abdominal evaluation CT prior to the planned explantation of a kidney and were randomly divided into 2 groups: Group A was examined with an ASIR 40 protocol (n=26), group B (n=27) was examined using a standard FBP (filtered back projection) protocol. Image quality was assessed both quantitatively (by obtaining attenuation values in different organ regions and calculating SNR and CNRs) and qualitatively (by two observers who evaluated image quality using a 5-point scale system). Applied dose was analyzed as CTDIvol (mGy), total DLP (mGy×cm) and effective dose (mSv). RESULTS: Applied dose in group A was about 26% lower than in group B (p<0.05). Between both groups, dose determining parameters such as scan length and patients' body diameter showed no significant difference. SNR (signal-to-noise ratio) was significantly higher in group A (p<0.05). CNRs (contrast-to-noise ratios) for different tissues were not significantly different. Observer rated image quality showed no significant difference. CONCLUSION: ASIR can contribute to a relevant dose reduction without any loss of image quality in CT scans for evaluating potential kidney donors.


Assuntos
Rim/diagnóstico por imagem , Doadores Vivos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Hospitais Universitários , Humanos , Iohexol/análogos & derivados , Transplante de Rim , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA