Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
1.
Circulation ; 104(17): 1999-2002, 2001 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-11673335

RESUMO

BACKGROUND: The distal-balloon protection system is being evaluated for its efficacy in preventing embolic neurological events during carotid stenting (CAS). We sought to determine the effect of this system on the frequency of Doppler-detected microembolic signals (MES) during CAS. METHODS AND RESULTS: Using transcranial Doppler, we compared the frequency of MES during CAS in 2 groups: 39 patients without distal protection and 37 who used the distal-balloon protection system (GuardWire). There were no significant differences in the clinical or angiographic characteristics between the 2 groups. Three phases with increased MES counts were identified during unprotected CAS; these were stent deployment, predilation, and postdilation (75+/-57, 32+/-36, and 27+/-25 METS, respectively). The distal-balloon protection significantly reduced the frequency of MES during CAS (MES counts: 164+/-108 in the control versus 68+/-83 in the protection group; P=0.002), particularly during these 3 phases. MES in the protection group were detected predominantly during sheath placement, guidewire manipulation, and distal-balloon deflation. CONCLUSION: Three phases with increased MES counts were identified during unprotected CAS (eg, stent deployment, predilation, and postdilation). The distal-balloon protection system significantly reduced the frequency of MES during CAS, particularly during these 3 phases.


Assuntos
Implante de Prótese Vascular/métodos , Doenças das Artérias Carótidas/cirurgia , Cateterismo/métodos , Embolia Intracraniana/prevenção & controle , Stents , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Cateterismo/efeitos adversos , Cateterismo/instrumentação , Feminino , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Período Intraoperatório , Masculino , Estudos Prospectivos , Stents/efeitos adversos , Hemorragia Subaracnóidea/etiologia , Taxa de Sobrevida , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
2.
Circulation ; 103(4): 532-7, 2001 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-11157718

RESUMO

BACKGROUND: Carotid stenting is a less invasive percutaneous procedure than carotid endarterectomy for the treatment of carotid stenosis. Reports suggest that it can be performed with periprocedural complication rates similar to those of carotid endarterectomy. The purpose of this study was to determine short- and long-term outcomes in the largest prospective cohort of carotid stenting patients. METHODS AND RESULTS: This study followed 528 consecutive patients (604 hemispheres/arteries) undergoing carotid stenting. There was a 0.6% (n=3) fatal stroke rate and 1% (n=5) nonstroke death rate at 30 days. The major stroke rate was 1% (n=6), and the minor stroke rate was 4.8% (n=29). The overall 30-day stroke and death rate was 7.4% (n=43). Over the 5-year study period, the 30-day minor stroke rate improved from 7.1% (n=7) for the first year to 3.1% (n=5) for the fifth year (P:<0.05 for trend). The best predictor of 30-day stroke and death was age >/=80 years. After the 30-day period, the incidence of fatal and nonfatal stroke was 3.2% (n=31). On Kaplan-Meier analysis, the 3-year freedom from ipsilateral or fatal stroke was 92+/-1%. CONCLUSIONS: Experience from a single group of operators demonstrates that carotid stenting can be performed with an acceptable 30-day complication rate. Late follow-up also demonstrates a low rate of fatal and nonfatal stroke. These results suggest that carotid stenting may be comparable to carotid endarterectomy, and it underscores the clinical equipoise and premise for the National Institute of Health-supported, randomized Carotid Revascularization Endarterectomy Versus Stent Trial comparing carotid stenting with carotid endarterectomy.


Assuntos
Artérias Carótidas/cirurgia , Estenose das Carótidas/cirurgia , Stents , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/mortalidade , Estenose das Carótidas/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
3.
Circulation ; 102(12): 1364-8, 2000 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-10993853

RESUMO

BACKGROUND: This prospective multicenter randomized clinical trial was designed to evaluate the long-term angiographic and clinical outcomes of elective treatment with the GR-II stent compared with the Palmaz-Schatz (PS) stent in patients with coronary stenoses. METHODS AND RESULTS: Seven hundred fifty-five patients with myocardial ischemia and de novo native coronary stenoses in 3- to 4-mm vessels were randomly assigned to the PS (375 patients) or the GR-II stent (380 patients). The primary end point was 12-month target lesion revascularization (TLR)-free survival. Angiography was performed at baseline and at follow-up in the first 300 consecutive patients to assess the frequency of angiographic restenosis. Procedure success was 98.5% for the GR-II stent and 99.4% for the PS stent (P:=0.19). At 30 days, patients assigned to the GR-II stent had a higher stent thrombosis rate (3.9% versus 0.3% for PS stent, P:<0.001) and TLR rate (3.9% versus 0.5% for PS stent, P:<0.001). The GR-II group had a higher follow-up restenosis frequency (47.3% versus 20.6% for the PS group, P:<0.001) and a lower 12-month TLR-free survival rate (71.7% versus 83.9% for the PS group, P:<0. 001). Multivariate logistic regression analysis identified a smaller final stent minimal lumen diameter (odds ratio [OR] 2.49, 95% CI 1. 56 to 3.98; P:<0.001), diabetes mellitus (OR 2.14, 95% CI 1.42 to 3. 22; P:<0.001), and use of the GR-II stent (OR 1.78, 95% CI 1.20 to 2. 64; P:<0.01) as independent determinants of 12-month TLR. CONCLUSIONS: On the basis of these long-term follow-up data, we conclude that use of the GR-II stent should be limited to the acute treatment of abrupt or threatened closure after failed conventional balloon angioplasty procedures.


Assuntos
Doença das Coronárias/terapia , Trombose Coronária/etiologia , Stents , Análise de Variância , Angiografia Coronária , Doença das Coronárias/mortalidade , Complicações do Diabetes , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Análise de Regressão , Stents/efeitos adversos , Resultado do Tratamento
4.
J Am Coll Cardiol ; 19(2): 372-81, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1732367

RESUMO

The morphologic changes in atherosclerotic coronary arteries and saphenous vein bypass grafts after placement of a balloon-expandable flexible coil stent (Cook) are described. In each case, the vessels were patent despite morphologic evidence of injury and dissection in the vessel wall. The stented region was reendothelialized and the tissue overlying the stent wires consisted primarily of smooth muscle cells. There was minimal inflammatory reaction to the stent wires. These findings suggest that the balloon-expandable flexible coil stent can effectively maintain vessel patency even in the setting of postangioplasty lumen disruption. In addition, the vessels tolerate the metal prosthesis with little evidence of tissue inflammatory reaction.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Endotélio Vascular/ultraestrutura , Músculo Liso Vascular/ultraestrutura , Veia Safena/patologia , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença da Artéria Coronariana/patologia , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade
5.
J Am Coll Cardiol ; 2(1): 38-44, 1983 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-6853916

RESUMO

The relation between a QRS score derived from the routine electrocardiogram and left ventricular function was investigated in 181 patients after myocardial infarction. Patients with left ventricular hypertrophy and conduction defects were excluded. The QRS score correlated closely with the severity of wall motion abnormalities and left ventricular ejection fraction. The more severe the dyssynergy, the higher the QRS score (hypokinesia = 3.0; akinesia = 5.4; dyskinesia = 9.1). The left ventricular ejection fraction (percent) = 66 - (3.3 x QRS score) (correlation coefficient [r] = -0.81, probability [p] less than 0.001). With use of this regression equation, the QRS score predicted angiographic left ventricular ejection fraction to within 12% of the angiographic ejection fraction in 29 of 30 additional patients studied prospectively. The QRS score was also related to clinical functional class. The worse the clinical manifestation of left ventricular dysfunction, the higher the QRS score (Killip class I = 3.5; class II = 6.5; class III = 7.1). A QRS score greater than or equal to 7 had a specificity of 97% and a sensitivity of 59% for predicting an ejection fraction of less than 45%. Patients with a QRS score of 7 or greater had severe wall motion abnormalities, higher peak serum creatine kinase levels, higher prevalence of multivessel coronary disease, poor clinical functional class and an unfavorable outcome. The QRS score provides an inexpensive, clinically useful estimate of left ventricular function after myocardial infarction and can identify patients at high risk.


Assuntos
Eletrocardiografia , Infarto do Miocárdio/diagnóstico , Adulto , Doença das Coronárias/diagnóstico , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Prognóstico , Radiografia , Volume Sistólico
6.
J Am Coll Cardiol ; 18(6): 1524-8, 1991 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-1939956

RESUMO

Coronary aneurysms are rare after conventional angioplasty and have not been reported after coronary stenting. Coronary artery stent sites were examined by follow-up angiography at a median of 4 months in 29 patients who received the Cook stent (Gianturco-Roubin) for acute coronary closure. Nineteen patients were treated with glucocorticoids administered intravenously or orally, or both, with or without colchicine and results were compared with those in 10 patients who were treated with neither agent. Standard therapy for all patients included routine administration of aspirin and heparin before and warfarin sodium (Coumadin) and aspirin after stent placement. Most patients also received dipyridamole and lovastatin during the follow-up period. Compliance with medications was confirmed by telephone conversation with each patient. Six (32%) of the 19 stented arteries showed evidence of coronary artery aneurysm, defined as expansion of the lumen outside the margins of the stent. None of the patients in the control group (who did not receive steroids or colchicine) developed aneurysm. This pattern of altered vascular healing in stented coronary segments appears to be due to the addition of multiple anti-inflammatory drugs rather than to stent presence alone. This observation demonstrates the possibility of medical impairment of normal vascular remodeling after acute injury and stent placement, which may be of benefit in designing future trials on restenosis.


Assuntos
Anti-Inflamatórios/efeitos adversos , Aneurisma Coronário/etiologia , Vasos Coronários/efeitos dos fármacos , Stents , Adulto , Colchicina/efeitos adversos , Aneurisma Coronário/induzido quimicamente , Aneurisma Coronário/diagnóstico por imagem , Angiografia Coronária , Vasos Coronários/lesões , Feminino , Seguimentos , Humanos , Hidrocortisona/efeitos adversos , Masculino , Pessoa de Meia-Idade , Prednisona/efeitos adversos , Cicatrização/efeitos dos fármacos
7.
J Am Coll Cardiol ; 11(2): 211-6, 1988 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2963055

RESUMO

Cardiac death consequent to acute vessel closure after coronary angioplasty occurred in 13 of 294 closures from 8,207 consecutive procedures performed at two centers since 1981 (0.16% cardiac mortality rate). To determine the predictors of cardiac death after acute coronary closure, 50 clinical, angiographic and procedural variables were analyzed by an observer unaware of the clinical outcome for each of the 13 patients who died and also 100 patients randomly chosen, in whom vessel closure after angioplasty did not result in death during hospitalization. Univariate analysis found female gender (p less than 0.0001), collateral channels from the vessel dilated (p less than 0.0001), use of balloon counterpulsation (p less than 0.0002), pre- and postprocedural hypotension (p = 0.0003 and p = 0.003, respectively), jeopardy score greater than or equal to 2.5 (p = 0.003), left ventricular hypertrophy (p = 0.013), hypertension (p = 0.02), diabetes (p = 0.02) and multivessel disease (p = 0.03) to be predictive of death. Multivariate analysis found collateral vessels, female gender and multivessel disease to be independent predictors of death. Thus, cardiac death after elective coronary angioplasty is very rare in experienced centers and occurs most often in women with a large amount of potentially ischemic myocardium. Hypotension often precedes the fatal closure event. Close attention to the amount of potentially ischemic myocardium and to the fluid volume status of these patients would seem to be especially warranted.


Assuntos
Angioplastia com Balão/mortalidade , Doença das Coronárias/mortalidade , Adulto , Idoso , Cardiomegalia/complicações , Doença das Coronárias/terapia , Diabetes Mellitus Tipo 1/complicações , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores Sexuais , Fatores de Tempo
8.
J Am Coll Cardiol ; 11(4): 714-8, 1988 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2965172

RESUMO

To identify the correlates of a second restenosis after repeat percutaneous coronary angioplasty, the records of 384 patients with single vessel disease who underwent repeat angioplasty for restenosis complicating a first elective angioplasty were examined. A second restenosis occurred in 47 (31%) of 151 patients having angiographic follow-up. Univariate correlates of a second restenosis were an interval between the first and second angioplasty less than 5 months (41 versus 20% of patients had restenosis, p less than 0.01), male gender (35 versus 12%, p less than 0.05), lesions length greater than or equal to 15 mm before the second angioplasty (62 versus 28%, p less than 0.05), diameter stenosis greater than 90% before the second angioplasty (67 versus 29%, p less than 0.05), final gradient greater than 20 mm Hg after the second angioplasty (52 versus 28%, p less than 0.05) and an additional site requiring dilation at the time of the second angioplasty (50 versus 29%, p = 0.10). Multivariate predictors of a second restenosis were an interval of less than 5 months between the first and the second angioplasty (p = 0.001), male gender (p = 0.001), lesion length greater than or equal to 15 mm before the second angioplasty (p = 0.001) and the need to have an additional site dilated at the time of the second angioplasty (p = 0.002). Patients at increased risk of restenosis after the second angioplasty can be identified and may serve as a useful population for intervention studies.


Assuntos
Angioplastia com Balão , Doença das Coronárias/terapia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Fatores de Risco
9.
J Am Coll Cardiol ; 8(6): 1271-6, 1986 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-2946740

RESUMO

This double-blind, randomized study evaluated the effect of nifedipine on restenosis after coronary angioplasty. Two hundred forty-one patients with dilation of 271 coronary sites were randomized at the time of hospital discharge to receive nifedipine, 10 mg (123 patients), or placebo (118 patients) four times daily for 6 months. No patient was known to have coronary artery spasm. The mean duration of therapy was 4.4 +/- 2 (mean +/- SD) months for nifedipine and 4.3 +/- 2 months for placebo. A restudy angiogram was available in 100 patients (81%) in the nifedipine group and 98 patients (83%) in the placebo group. A recurrent coronary stenosis was noted in 28% of patients in the nifedipine group and in 29.5% of those in the placebo group (p = NS). The mean diameter stenosis was 36.4 +/- 23% for the nifedipine group and 36.7 +/- 23% for the placebo group (p = NS). By pill count, 78% of patients receiving nifedipine and 82% of those receiving placebo complied with the study drug regimen. Coronary stenosis recurred in 33% of patients in the placebo group and in 29% of patients in the nifedipine group who complied with the regimen and had angiograms (p = NS). In conclusion, the study did not demonstrate a significant beneficial effect of nifedipine on the incidence of recurrent stenosis after successful percutaneous transluminal coronary angioplasty.


Assuntos
Angioplastia com Balão , Doença das Coronárias/terapia , Nifedipino/uso terapêutico , Adulto , Idoso , Doença das Coronárias/prevenção & controle , Humanos , Pessoa de Meia-Idade , Nifedipino/administração & dosagem , Nifedipino/efeitos adversos , Cooperação do Paciente , Recidiva , Fatores de Tempo
10.
J Am Coll Cardiol ; 22(5): 1273-9, 1993 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-8227779

RESUMO

OBJECTIVES: A new percutaneous collagen hemostasis device was compared with conventional compression techniques after diagnostic catheterization and angioplasty. BACKGROUND: Peripheral vascular complications after diagnostic catheterization or more complex interventional procedures, as well as the discomfort of manual compression and prolonged bed rest, represent significant morbidity for invasive cardiac procedures. METHODS: A prospective, multicenter, randomized trial was designed to compare the hemostasis time in minutes and the incidence of vascular complications in patients receiving a vascular hemostasis device with those undergoing conventional compression techniques. RESULTS: After diagnostic catheterization, hemostasis time was significantly less with the vascular hemostasis device than with conventional manual compression (4.1 +/- 2.8 min [n = 90 patients] vs. 17.6 +/- 9.2 min [n = 75], p < 0.0001). This difference was greater in patients undergoing angioplasty and was unrelated to the anticoagulation status (4.3 +/- 3.7 min [n = 71 not receiving heparin], 7.6 +/- 11.6 min [n = 85 receiving heparin], 33.6 +/- 24.2 min [n = 134 control patients not receiving heparin], p < 0.0001 vs. control patients). The time from the start of the procedure to ambulation was slightly less after diagnostic catheterization in patients treated with the device (13.3 +/- 12.1 h vs. 19.2 +/- 17.8 h, p < 0.05). It was also less in patients who underwent angioplasty when the device was used after discontinuation of anticoagulation (23.0 +/- 11.1 h, without heparin), as compared with control compression techniques (32.7 +/- 18.8 h, p < 0.0001). Time to ambulation was even shorter (16.1 +/- 11.1 h, p < 0.0001) in patients in whom the device was placed immediately after angioplasty while they were still fully anticoagulated with a prolonged activated clotting time (336 +/- 85 s). There were no major complications (surgery or transfusion) after diagnostic catheterization and a low incidence of major complications in patients who underwent angioplasty (0.7% in control patients, 1.4% with the device without heparin, 1.2% with the device and heparin, p = NS). After angioplasty, there was a trend toward fewer hematomas when the device was used in the absence of heparin (4.2% vs. 9.7% in control patients, p = 0.14). CONCLUSIONS: A new vascular hemostasis device can significantly reduce the puncture site hemostasis time and the time to ambulation without significantly increasing the risk of peripheral vascular complications. The role of this technology in reducing complications, length of hospital stay and cost remains to be determined.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Colágeno/uso terapêutico , Angiografia Coronária/efeitos adversos , Hematoma/epidemiologia , Técnicas Hemostáticas/instrumentação , Doenças Vasculares Periféricas/epidemiologia , Idoso , Repouso em Cama , Testes de Coagulação Sanguínea , Colágeno/administração & dosagem , Deambulação Precoce , Feminino , Custos de Cuidados de Saúde , Hematoma/sangue , Hematoma/etiologia , Hemostasia , Heparina/uso terapêutico , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/sangue , Doenças Vasculares Periféricas/etiologia , Pressão , Estudos Prospectivos , Fatores de Tempo , Tempo de Coagulação do Sangue Total
11.
J Am Coll Cardiol ; 15(5): 986-94, 1990 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2312987

RESUMO

Hemodynamic and metabolic changes were measured at rest and during exercise in 23 patients with chronic heart failure and in 6 control subjects. Exercise was limited by leg fatigue in both groups and capacity was 40% lower in the patients with failure. At rest, comparing patients with control subjects, heart rate and right atrial and pulmonary wedge pressure were higher; cardiac output, stroke volume and work indexes and ejection fraction were lower; mean arterial and right atrial pressure and systemic resistance were similar. During all phases of exercise in patients with heart failure, pulmonary wedge pressure and systemic vascular resistance were higher and pulmonary vascular resistance remained markedly elevated compared with values in control subjects. Cardiac output was lower in the patients with failure, but appeared to have the same physiologic distribution in both groups during exercise. Although arterial-femoral venous oxygen content difference was higher in patients with heart failure, this increase did not compensate for the reduced blood flow. Even though the maximal oxygen consumption was significantly reduced, femoral venous lactate and pH values were higher than values in control subjects, but femoral venous pH was similar in both groups at their respective levels of maximal exercise. Ejection fraction was lower in those with heart failure at rest and did not increase with exercise. Ventilation in relation to oxygen consumption was higher in patients with failure than in control subjects.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Esforço Físico/fisiologia , Adulto , Gasometria , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Ventriculografia com Radionuclídeos , Volume Sistólico , Tecnécio
12.
J Am Coll Cardiol ; 8(6): 1461-6, 1986 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-3782648

RESUMO

The effects of nifedipine on arterial oxygenation and hemodynamics were studied at rest and during bicycle exercise in 12 men (mean age 55 years, range 41 to 67) with stable exertional angina. The study was conducted double-blind on 2 days, 1 week apart, using a placebo-controlled crossover design. On each day, measurements at rest were made before and 20 minutes after 20 mg sublingual nifedipine or placebo and were followed by measurements made during exercise. Compared with placebo, nifedipine reduced mean arterial pressure, systemic vascular resistance and pulmonary vascular resistance, and increased heart rate and cardiac output at rest and during exercise. It did not alter mean pulmonary artery or pulmonary artery wedge pressures at rest, but decreased them during exercise. Nifedipine decreased arterial oxygen tension (PaO2) from 96 +/- 10 to 90 +/- 13 mm Hg (p less than 0.05) at rest and from 99 +/- 11 to 92 +/- 12 mm Hg (p less than 0.005) at submaximal exercise (33 +/- 21 W), but did not alter it (100 +/- 12 versus 100 +/- 16 mm Hg, p = NS) at maximal exercise (68 +/- 30 W). The reduction in PaO2 was not due to alveolar hypoventilation, because nifedipine did not alter arterial carbon dioxide tension, or to changes in mixed venous oxygen tension, which nifedipine increased at rest (39 +/- 2 versus 43 +/- 3 mm Hg, p less than 0.001) and during submaximal exercise (31 +/- 4 versus 33 +/- 4 mm Hg, p less than 0.03) and maximal exercise (27 +/- 3 versus 31 +/- 3 mm Hg, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Angina Pectoris/sangue , Nifedipino/uso terapêutico , Oxigênio/sangue , Esforço Físico , Descanso , Adulto , Idoso , Angina Pectoris/tratamento farmacológico , Angina Pectoris/fisiopatologia , Artérias , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Parcial
13.
J Am Coll Cardiol ; 12(4): 955-63, 1988 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2971086

RESUMO

To determine if incomplete redistribution at 4 h in exercise tomographic thallium-201 studies is always due to a myocardial scar, 141 patients were evaluated before and after a total of 160 successful percutaneous transluminal coronary angioplasty procedures. Thallium studies were analyzed using polar "bull's-eye" maps. For both immediate and delayed images, abnormalities were quantified as a thallium score by calculating a standard deviation-weighted sum of pixels greater than 2.5 SD below gender-matched normal limits. One hundred forty-four of 160 studies indicated abnormalities before angioplasty. Of these 144, incomplete redistribution occurred in 111 (77%): 16 (14%) in patients with and 95 (86%) in patients without prior Q wave myocardial infarction. After angioplasty, improvement in delayed image score occurred in 8 (50%) of 16 patients with prior infarction and 72 (76%) of 95 patients without prior infarction (p less than 0.05). After angioplasty, delayed images were normal in 1 (6%) of 16 patients with prior infarction and 32 (34%) of the 95 without (p less than 0.05). Before angioplasty, delayed image scores were positively correlated with scores in the immediate postexercise images in patients with (r = 0.84) and those without (r = 0.69) prior infarction. To determine if additional delayed images could help differentiate scar from ischemia, an 8 to 24 h delayed image was obtained in each of 40 other patients with incomplete redistribution at 4 h. Of 28 patients without prior infarction, 15 had no redistribution, and 13 had further redistribution at 8 to 24 h.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada de Emissão , Adulto , Idoso , Angioplastia com Balão , Cardiomiopatias/terapia , Diagnóstico Diferencial , Eletrocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Radioisótopos de Tálio , Fatores de Tempo
14.
J Am Coll Cardiol ; 20(3): 610-5, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1512340

RESUMO

OBJECTIVES: This study was performed to describe the initial experience and follow-up of ultrasound-guided compression of pseudoaneurysms in patients receiving systemic anticoagulant or antiplatelet therapy, or both, after recent cardiac catheterization or percutaneous transluminal coronary angioplasty. BACKGROUND: Femoral artery pseudoaneurysm formation after an interventional procedure is becoming more common as larger caliber catheters and prolonged anticoagulant and antiplatelet therapy are being used. Traditional treatment of this complication has been surgical repair. This study describes a new method of closing femoral pseudoaneurysms by using external compression guided by Doppler color flow imaging. METHODS: Fifteen patients, 3 undergoing cardiac catheterization and 12 undergoing coronary angioplasty, developed an expansile groin mass at the vascular access site diagnosed as a femoral artery pseudoaneurysm by Doppler ultrasound. Seven of the patients had undergone coronary stenting and were receiving postprocedural anticoagulant therapy. These patients underwent progressive graded mechanical (C-clamp) external compression guided by ultrasound. The mechanical compression was titrated to obliterate the vascular tracts to these aneurysms and maintain adequate flow in the femoral artery. RESULTS: After an average compression time of 30 min (range 10 to 120), these tracts remained closed. Follow-up ultrasound examination at 24 h or later confirmed continued closure in all. CONCLUSIONS: This study suggests that nonsurgical closure of femoral pseudoaneurysms is feasible. This technique may be valuable in managing vascular access-related complications after diagnostic and interventional procedures, even in patients requiring prolonged anticoagulant therapy.


Assuntos
Aneurisma/terapia , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Anticoagulantes/uso terapêutico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Ultrassonografia/métodos
15.
J Am Coll Cardiol ; 4(5): 902-7, 1984 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-6491083

RESUMO

The acute effects of nifedipine (20 mg sublingually) on hemodynamics and cardiac function were studied at rest and during supine bicycle exercise in 20 patients with aortic regurgitation. At rest, heart rate increased by 13%, systemic vascular resistance decreased by 34% and regurgitant index decreased by 17%. The change in systemic vascular resistance was related to its initial rest level (r = 0.82, p less than 0.001) and to the changes in forward cardiac output (r = 0.58, p less than 0.01) and regurgitant index (r = 0.60, p less than 0.01). Left ventricular end-diastolic and end-systolic volumes, stroke volume and ejection fraction were unchanged, whereas right ventricular ejection fraction increased. During exercise, nifedipine administration further increased heart rate by 8% and decreased systemic vascular resistance by 19%. Both forward stroke volume and forward cardiac output increased, but total left ventricular stroke volume was unchanged, resulting in a significant decrease in regurgitant index. Although left ventricular end-diastolic volume was slightly decreased, end-systolic volume did not increase; thus, ejection fraction was higher than that during control exercise (p less than 0.01). Right ventricular ejection fraction increased further. In aortic regurgitation, the acute administration of nifedipine improved cardiac performance and reduced regurgitation at rest and during exercise as a result of afterload reduction and increased heart rate. Whether these beneficial effects will occur during long-term therapy requires further investigation.


Assuntos
Insuficiência da Valva Aórtica/tratamento farmacológico , Teste de Esforço , Coração/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Nifedipino/uso terapêutico , Adulto , Insuficiência da Valva Aórtica/diagnóstico por imagem , Débito Cardíaco/efeitos dos fármacos , Feminino , Coração/diagnóstico por imagem , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Cintilografia , Volume Sistólico/efeitos dos fármacos , Resistência Vascular/efeitos dos fármacos
16.
J Am Coll Cardiol ; 22(1): 135-43, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8509533

RESUMO

OBJECTIVES: This study reports on the initial experience with the Gianturco-Roubin flexible coronary stent. The immediate and 6-month efficacy of the device and the incidence of the complications of death, myocardial infarction, emergency coronary artery bypass surgery and recurrent ischemic events are presented. BACKGROUND: Abrupt or threatened vessel closure after coronary angioplasty is associated with increased risk of myocardial infarction, emergency coronary artery bypass graft surgery and in-hospital death. When dissection or prolapse of dilated plaque into the lumen is unresponsive to additional or prolonged balloon catheter inflation, coronary stenting offers a nonsurgical mechanical means to rapidly restore stable vessel geometry and adequate coronary blood flow. METHODS: From September 1988 through June 1991, 518 patients underwent attempted coronary stenting with the 20-mm long Gianturco-Roubin coronary stent for acute or threatened vessel closure after angioplasty. In 494 patients, one or more stents were deployed. Thirty-two percent of patients received stents for acute closure and 69% for threatened closure. RESULTS: Successful deployment was achieved in 95.4% of patients. Overall, stenting resulted in an immediate angiographic improvement in the diameter stenosis from 63 +/- 25% before stenting to 15 +/- 14% after stenting. Emergency coronary artery bypass graft surgery was required in 4.3% (21 of 493 patients). The incidence of in-hospital myocardial infarction (Q wave and non-Q wave) was 5.5% (27 of 493 patients). At 6 months, myocardial infarction was infrequent, occurring in 1.6% (8 of 493 patients). The incidence of in-hospital death was 2.2% (11 of 493 patients). Late death occurred in 7 patients (1.4%) and 34 patients (6.9%) required later bypass graft surgery. Complications included blood loss, primarily from the arterial access site, and subacute thrombosis of the stented vessel in 43 patients (8.7%). CONCLUSIONS: The early multicenter experience suggests that this stent is a useful adjunct to coronary angioplasty to prevent or minimize complications associated with flow-limiting coronary artery dissections previously correctable only by surgery. Although this study was not randomized, it demonstrated a high technical success rate and encouraging results with respect to the low incidence of emergency coronary artery bypass graft surgery and myocardial infarction.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Ponte de Artéria Coronária , Doença das Coronárias/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Recidiva , Stents/efeitos adversos , Análise de Sobrevida , Resultado do Tratamento
17.
J Am Coll Cardiol ; 9(6): 1214-8, 1987 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2953771

RESUMO

Over a 5 year period at three centers, 53 patients underwent percutaneous transluminal angioplasty of a right coronary artery ostial stenosis. The procedure was successful in 42 patients (79%) and unsuccessful in 11, of whom 5 (9.4%) required emergency coronary artery bypass grafting because of abrupt closure. The right coronary ostial lesion had distinctive technical requirements to achieve success, including high pressure balloon inflation (10 +/- 4 atm) and the need for unconventional right coronary guide catheters. Technical factors that account for increased difficulty in these patients include: problems with guide catheter impaction and ostial trauma; inability to inflate the balloon with adequate guide catheter support; and need for increased intracoronary manipulation. The stenoses were quite discrete (4 +/- 5 mm) and calcified in the majority (40) of the 53 patients. Long-term follow-up (mean 12.5 months, range 4 to 60) of these patients demonstrated clinical recurrence of angina in 20 patients (48%) and angiographically proved restenosis in 16 (38%). Repeat coronary angioplasty was successful in three of six patients for relief of symptoms for over 6 months. In conclusion, angioplasty of the right coronary ostial lesion compared with nonostial dilation leads to a suboptimal early success rate; an apparent high risk of emergency bypass surgery; and a high restenosis rate. Careful assessment of the patient with this lesion and improved technology appear to be warranted.


Assuntos
Angioplastia com Balão/normas , Doença das Coronárias/terapia , Angiografia , Angioplastia com Balão/efeitos adversos , Ensaios Clínicos como Assunto , Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Seguimentos , Humanos , Recidiva
18.
J Am Coll Cardiol ; 37(8): 2074-9, 2001 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-11419890

RESUMO

OBJECTIVES: The purpose of this study was to assess the efficacy of emergency stent implantation for the treatment of perioperative stroke after carotid endarterectomy (CEA). BACKGROUND: Carotid endarterectomy has been proven safe and effective in reducing the risk of stroke in symptomatic and asymptomatic patients with >60% carotid artery stenosis. However, perioperative stroke has been reported in 1.5% to 9% of CEA cases. The management of such a complication is challenging. Recently, percutaneous transluminal carotid angioplasty with stent deployment has emerged as a valuable and alternative strategy for the treatment of carotid artery disease. METHODS: Between April 1998 and February 2000, 18 of the 995 patients (1.8%) who had CEA in our institution experienced perioperative major or minor neurological complications. Of these, 13 patients underwent emergency carotid angiogram and eventual stent implantation, whereas the remaining five had surgery re-exploration. RESULTS: Carotid angiogram was performed within 20+/-10 min and revealed vessel flow-limiting dissection (five cases) or thrombosis (eight cases). Percutaneous transluminal carotid angioplasty with direct stenting (self-expandable stent) was performed in all 13 cases. Angiographic success was 100%. Complete remission of neurological symptoms occurred in 11 of the 13 patients treated by stent implantation and in one of the five patients treated by surgical re-exploration (p = 0.024). CONCLUSIONS: Stent implantation seems to be a safe and effective strategy in the treatment of perioperative stroke complicating CEA, especially when carotid dissection represents the main anatomic problem.


Assuntos
Endarterectomia das Carótidas/efeitos adversos , Stents , Acidente Vascular Cerebral/etiologia , Idoso , Serviços Médicos de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
J Am Coll Cardiol ; 31(1): 50-6, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9426017

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and 1-year clinical outcome for the Advanced Cardiovascular Systems (ACS) MultiLink stent. BACKGROUND: Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. METHODS: Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations. Clinical follow-up was obtained at 30 days and 1 year. RESULTS: All 49 patients had successful placement of a MultiLink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction. After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001). Minimal lumen cross-sectional area by IVUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm2, respectively, p < 0.001). However, only 64% of stents achieved a lumen/reference area ratio > or = 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery. CONCLUSIONS: Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices.


Assuntos
Angiografia Coronária , Doença das Coronárias/terapia , Stents , Ultrassonografia de Intervenção , Idoso , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento
20.
J Am Coll Cardiol ; 29(5): 934-40, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9120178

RESUMO

OBJECTIVES: We sought to determine the in-hospital clinical outcome and angiographic results of patients prospectively entered into the National Heart, Lung, and Blood Institute/New Approaches to Coronary Intervention (NHLBI/NACI) Registry who received Gianturco-Roubin stents as an unplanned new device. BACKGROUND: Between August 1990 and March 1994, nine centers implanted Gianturco-Roubin flex stents as an unplanned new device in the initial treatment of 350 patients (389 lesions) who were prospectively enrolled in the NHLBI/NACI Registry. METHODS: Patients undergoing implantation of the Gianturco-Roubin flex stent were prospectively entered into the Gianturco-Roubin stent portion of the NHLBI/NACI Registry. Only subjects receiving the Gianturco-Roubin stent as a new device in an unplanned fashion are included. RESULTS: The mean age of the patient group was 61.8 years, and the majority of the patients were men. A history of percutaneous transluminal coronary angioplasty (PTCA) was present in 35.4% of the group, and 16.9% had previous coronary artery bypass graft surgery. Unstable angina was present in 67.7%. Double- or triple-vessel coronary artery disease was present in 55.4%, and the average ejection fraction was 58%. The presence of thrombus was noted in 7.3%, and 7.2% had moderate to severe tortuosity of the lesion. The angiographic success rate was 92%. Individual clinical sites reported that 66.3% of the stents were placed after suboptimal PTCA, 20.3% for abrupt closure and 13.4% for some other technical PTCA failure. Major in-hospital events occurred in 9.7% of patients, including death in 1.7%, Q wave myocardial infarction in 3.1% and emergency bypass surgery in 6%. Abrupt closure of a stented segment occurred in 3.1% of patients at a mean of 3.9 days. Cerebrovascular accident occurred in 0.3%, and transfusion was required in 10.6%. Vascular events with surgical repair occurred in 8.6% of patients. CONCLUSIONS: Despite these complications, the use of this device for the treatment of a failed or suboptimal PTCA result remains promising given the adverse outcome of abrupt closure with conventional (nonstent) treatment.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Stents , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , National Institutes of Health (U.S.) , Sistema de Registros , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA