Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Am Chem Soc ; 143(1): 420-432, 2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33347313

RESUMO

While a variety of compounds containing planar tetracoordinated carbon (ptC), the so-called anti-van't Hoff/Le Bel carbon, are known experimentally, stable systems containing planar tetracoordinated silicon (ptSi) are barely known. As part of our studies on the application of stereoelectronically well-defined transition-metal fragments to stabilize silicon in unprecedented bonding modes, we report herein the synthesis and full characterization of a series of thermally stable complexes of the general formula [Tp'(CO)2MSiC(R1)C(R2)M(CO)2Tp'] (M = Mo, W; R1 = R2 = Me or R1 = H, R2 = SiMe3, Ph; Tp' = κ3-N,N',N″-hydridotris(3,5-dimethylpyrazolyl)borate), which incorporate a ptSi atom in addition to two ptC atoms. The complexes were obtained by reacting the metallasilylidyne complexes [Tp'(CO)2M≡Si-M(CO)2(PMe3)Tp'] with alkynes R1C≡CR2 and were comprehensively analyzed by experimental studies and quantum chemical calculations. The analyses revealed that the ptSi atom is embedded in a tricyclic trapezoidal core featuring one internal SiC2 and two outer M-Si-C three-membered rings, which are fused via two Si-C bonds. The structural peculiarities evoked by the presence of an anti-van't Hoff/Le Bel ptSi center, such as the short M-Si bonds, a nearly linear M-Si-M spine, long M-C bonds, and the presence of two planar tetracoordinated carbon atoms were elucidated by a detailed analysis of the electronic structure, suggesting that one factor for the stabilization of the ptSi geometry is the aromaticity of the central SiC2 ring having two delocalized π electrons. Remarkably, the results further indicate the existence of both anti-van't Hoff/Le Bel carbon and silicon centers next to each other in the isolated complexes.

2.
Scand J Gastroenterol ; 49(6): 722-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24694300

RESUMO

BACKGROUND AND STUDY AIMS: MRI-guided procedures combine high-quality imaging with lack of radiation. Percutaneous transhepatic cholangiodrainage under real-time MRI guidance (MRI-PTCD) seems promising, allowing targeted puncture and avoiding multiple blind passes and use of contrast, which are associated with standard PTCD's heaviest complications. PATIENTS AND METHODS: Aim of this study was to investigate the feasibility of MRI-PTCD in three outbred piglets. Obstructive cholestasis was induced by common bile duct ligation. Two days later, MRI-PTCD was performed (open MRI, 1.0 Tesla) with prototype MRI-compatible accessories. Visualization was achieved with a balanced steady-state free precession real-time sequence (bSSFP: 0.75 frames/s, TR/TE [ms]: 7.2/3.6; flip angle: 45°; 200 × 200 matrix size; resolution: 1.3 × 1.3 mm(2), slice thickness: 7 mm). Cannulation of the bile ducts was followed by placement of Yamakawa drainages. RESULTS: Twelve punctures were performed (four per animal, 10/12 successful); in 2/10 the bile ducts could not be cannulated. Animal survival was 100% and no significant complications occurred. CONCLUSIONS: Initial data show that MRI-PTCD can be successfully performed. This may lead to establishment of a new optimized PTCD technique compared to the standard approach under fluoroscopy.


Assuntos
Ductos Biliares/cirurgia , Colestase/cirurgia , Drenagem/métodos , Imagem por Ressonância Magnética Intervencionista , Animais , Cateterismo/métodos , Drenagem/instrumentação , Estudos de Viabilidade , Feminino , Cirurgia Assistida por Computador , Suínos
3.
AJR Am J Roentgenol ; 201(3): 496-504, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23971441

RESUMO

OBJECTIVE: The purpose of this study was to examine the advantages of MRI-guided ankle stress examinations in the detection of chronic ankle instability. SUBJECTS AND METHODS: An MRI-compatible stress device was developed and tested for MRI safety. Bilateral MRI stress examinations were performed on 50 volunteers with and without clinically evident subjective instability of the ankle joints (72 subjective stable ankle joints in 37 subjects, 28 ankles in 15 subjects with chronic ankle instability). Both the inversion test and the anterior drawer test were performed under axial, coronal, 45° paraxial, and sagittal T2-weighted fast spin-echo image control. MR images were assessed for talar tilt, subtalar tilt, anterior talus translation, anterior calcaneus translation, medial talocalcaneal translation, and the diameters of the lateral ankle ligaments (anterior talofibular ligament, calcaneofibular ligament, and posterior talofibular ligament). RESULTS: The MRI stress device was found suitable and safe for use in the MRI environment. The talocrural and subtalar joints could be assessed simultaneously. Significant differences between groups A and B (p≤0.05) were found in talar tilt, subtalar tilt, anterior talus translation, anterior calcaneus translation, medial talocalcaneal translation, and decrease in diameters of calcaneofibular and posterior talofibular ligaments. Also found were sex differences in talar tilt, subtalar tilt, anterior talus translation, and diameters of the anterior talofibular, calcaneofibular, and posterior talofibular ligaments. Significant relations were found between talar tilt and anterior talus translation, subtalar tilt and anterior calcaneus translation, subtalar tilt and medial talocalcaneal translation, and between anterior calcaneus translation and medial talocalcaneal translation in groups A and B. CONCLUSION: Stress examination under MRI control has advantages in the assessment of mechanical ankle instability. Additional diagnostic and clinically relevant information is obtained through direct imaging of the ligaments and assessment of additional parameters of ankle laxity (subtalar tilt, anterior calcaneus translation, medial talocalcaneal translation). The main advantages are objective imaging and measurement of abnormal looseness of the lower ankle joint and its direct simultaneous comparison with the upper ankle joint.


Assuntos
Articulação do Tornozelo/fisiopatologia , Instabilidade Articular/diagnóstico , Instabilidade Articular/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Fenômenos Biomecânicos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Mecânico
4.
Magn Reson Med ; 68(2): 600-5, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22213345

RESUMO

The in vivo pain treatment was successfully performed with the patient in a prone position. The PD-weighted TSE with echo time = 10 ms rendered contrast-to-noise-ratio values of 27 ± 10 for needle/fat, 1.6 ± 5 for needle/muscle, and 4 ± 4.7 for needle/nerve tissue. The mean diameter of the needle artifact was 1.2 ± 0.2 mm. In the T(1)-weighted gradient echo, the needle's artifact diameter was 6 ± 2 mm; the needle's contrast-to-noise ratio relative to muscle tissue was 4 ± 2, 7.6 ± 1.5 for needle/fat, and 5 ± 1 for needle/nerve tissue. With the PD-weighted TSE (echo time = 10 ms) and the T(1)-weighted gradient echo, the needle was imaged reliably throughout the intervention. The butterfly surface coil is feasible for the guidance of spinal interventions in a prone patient.


Assuntos
Bupivacaína/administração & dosagem , Dor Lombar/tratamento farmacológico , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Bloqueio Nervoso/instrumentação , Transdutores , Anestésicos Locais/administração & dosagem , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/instrumentação , Injeções Espinhais/instrumentação , Dor Lombar/diagnóstico , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
5.
Cardiovasc Eng Technol ; 13(1): 129-138, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34189711

RESUMO

Better understanding of the lead curvature, movement and their spatial distribution may be beneficial in developing lead testing methods, guiding implantations and improving life expectancy of implanted leads. OBJECTIVE: The aim of this two-phase study was to develop and test a novel biplane cine-fluoroscopy-based method to evaluate input parameters for bending stress in leads based on their in vivo 3D motion using precisely determined spatial distributions of lead curvatures. Potential tensile, compressive or torque forces were not subjects of this study. METHODS: A method to measure lead curvature and curvature evolution was initially tested in a phantom study. In the second phase using this model 51 patients with implanted ICD leads were included. A biplane cine-fluoroscopy recording of the intracardiac region of the lead was performed. The lead centerline and its motion were reconstructed in 3D and used to define lead curvature and curvature changes. The maximum absolute curvature Cmax during a cardiac cycle, the maximum curvature amplitude Camp and the maximum curvature Cmax@amp at the location of Camp were calculated. These parameters can be used to characterize fatigue stress in a lead under cyclical bending. RESULTS: The medians of Camp and Cmax@amp were 0.18 cm-1 and 0.42 cm-1, respectively. The median location of Cmax was in the atrium whereas the median location of Camp occurred close to where the transit through the tricuspid valve can be assumed. Increased curvatures were found for higher slack grades. CONCLUSION: Our results suggest that reconstruction of 3D ICD lead motion is feasible using biplane cine-fluoroscopy. Lead curvatures can be computed with high accuracy and the results can be implemented to improve lead design and testing.


Assuntos
Desfibriladores Implantáveis , Insuficiência da Valva Tricúspide , Humanos , Átrios do Coração , Valva Tricúspide
6.
Eur Radiol ; 21(5): 1004-15, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21127882

RESUMO

OBJECTIVE: To investigate the performance of an open MRI system at its conceptual limits by examining excessively obese patients who otherwise could not receive adequate imaging examinations. METHODS: Twenty-six excessively obese patients (BMI ≥ 35, average age 46) where CT, standard MR or ultrasound examinations were not possible or not conclusive were referred to an open MRI system at 1.0 Tesla. Image quality was measured by SNR and CNR with the integrated body coil for obese patients and optimal body coils for a regular weight control group (average BMI 23, average age 30). MRI findings were evaluated by a diagnostic impact matrix. RESULTS: SNR and CNR were generally lower in obese patients when the integrated body coil was used compared to the normal weight group with ideal body coils e.g.: For cerebral imaging T2W TSE (<5% for white matter, ca. 30% for grey matter) and T1W SE (ca. 15% for white matter, <5% for grey matter), for spinal imaging T2W TSE (ca. 35% for disc and vertebral body) and T1W SE (about 2% for disc, ca. 10% for vertebral body). Relevant new diagnoses impacting patient's therapy were identified in 30% (8/26), the particular medical question of the referring physician could be ruled out as possible reason for the medical condition in 53% (14/26). CONCLUSION: In excessively obese patients where CT, standard MR or ultrasound examination is not possible or not conclusive open MRI system have great potential in diagnostic evaluation, offering lower but sufficient image quality to impact therapy.


Assuntos
Diagnóstico por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade/patologia , Adulto , Artefatos , Índice de Massa Corporal , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Obesidade/diagnóstico , Ultrassonografia/métodos
7.
J Magn Reson Imaging ; 31(6): 1499-503, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20512906

RESUMO

PURPOSE: To validate an unspoiled gradient-recalled echo pulse sequence with dual echo acquisition as a means to increase temperature sensitivity while monitoring intradiscal laser ablation therapy. MATERIALS AND METHODS: Phantom experiments as well as in vitro thermal ablation simulations were performed in an open 1.0T magnetic resonance (MR) scanner. Three methods of noninvasive MR-thermometry based on the signal void decrease caused by T1-relaxation time increase (T1), the temperature-dependent proton resonance frequency (PRF) shift, and a combination of both methods with complex differences (CD) were compared. Temperature accuracy and reliability of temperature distribution were the main assessment criteria. RESULTS: The optimum temperature sensitivity was found using CD in phantom experiments. During in vitro experiments the PRF showed the smallest margin of error (T1: +/-1.64 degrees C, PRF: +/-1.23 degrees C, CD: +/-1.29 degrees C) and the best qualitative evaluation of temperature. CONCLUSION: Intradiscal temperature monitoring with an unspoiled dual-echo sequence is most accurate with PRF-thermometry in combination with the long echo time. Magnitude images with an initial short echo time permit high image detail of the heat-induced lesion.


Assuntos
Imageamento por Ressonância Magnética/métodos , Algoritmos , Temperatura Corporal , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Prótons , Reprodutibilidade dos Testes , Temperatura
8.
J Magn Reson Imaging ; 31(3): 636-44, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20187207

RESUMO

PURPOSE: To develop a signal-inducing bone cement for musculoskeletal procedures in magnetic resonance imaging (MRI). MATERIALS AND METHODS: Acrylic resins were mixed with contrast agents (CAs) and water. We determined the ideal concentration of the components and assessed feasibility in cadaveric bones in an open high-field MR scanner. The contrast-to-noise ratio (CNR) in air and bone was evaluated and mechanical tests were achieved. We determined the amount of water that was not incorporated and measured the amount of CA released with photometric analysis. The cement was analyzed microscopically. RESULTS: Preparation and application of the CA-water-cement compound was feasible and its differentiation in MRI was clear. The maximal CNR(air) had a value of 157.5 (SD 18.3) in an interventional fast T1W turbo-spin echo (TSE) sequence. The compressive strength decreased with the amount of water added. Although nearly 50% of the water added was not incorporated in the cement, the CNR was sufficient for cement detection. The threshold for systemic toxicity of delivered CA was not reached and the microscopic analysis showed water bubbles in the cement. CONCLUSION: A signal-inducing bone cement is feasible for the use in MRI.


Assuntos
Cimentos Ósseos/análise , Cimentos Ósseos/uso terapêutico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Cimentos Ósseos/síntese química , Composição de Medicamentos/métodos , Estudos de Viabilidade , Imagens de Fantasmas
9.
Int J Hyperthermia ; 26(4): 295-304, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20210604

RESUMO

PURPOSE: The purpose of this study was to evaluate different methods of magnetic resonance thermometry (MRTh) for the monitoring of intradiscal laser ablation therapy in an open 1.0 Tesla magnetic resonance (MR) scanner. MATERIAL AND METHODS: MRTh methods based on the two endogenous MR temperature indicators of spin-lattice relaxation time T1 and water proton resonance frequency (PRF) shift were optimised and compared in vitro. For the latter, we measured the effective spin-spin relaxation times T2* in intervertebral discs of volunteers. Then we compared four gradient echo-based imaging techniques to monitor laser ablations in human disc specimens. Criteria of assessment were outline of anatomic detail, immunity against needle artefacts, signal-to-noise ratio (SNR) and accuracy of the calculated temperature. RESULTS: T2* decreased in an inverse and almost linear manner with the patients' age (r = 0.9) from 70 to 30 ms (mean of 49 ms). The optimum image quality (anatomic details, needle artefacts, SNR) and temperature accuracy (+/-1.09 degrees C for T1-based and +/-1.11 degrees C for PRF-based MRTh) was achieved with a non-spoiled gradient-echo sequence with an echo time of TE = 10 ms. CONCLUSION: Combination of anatomic and thermometric non-invasive monitoring of laser ablations in the lumbar spine is feasible. The temperature accuracy of the investigated T1- and PRF-based MRTh methods in vitro is high enough and promises to be reliable in vivo as well.


Assuntos
Temperatura Corporal/efeitos da radiação , Disco Intervertebral/cirurgia , Terapia a Laser/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Envelhecimento/fisiologia , Feminino , Humanos , Vértebras Lombares/cirurgia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Imagens de Fantasmas , Adulto Jovem
10.
Arch Orthop Trauma Surg ; 130(6): 803-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19921225

RESUMO

INTRODUCTION: Of late, computer-assisted surgery has become a novel challenge for orthopedic surgeons. However, for orthopedic interventions magnetic resonance (MR) fluoroscopy is in its early stages of development. The authors have developed an innovative passive navigation concept, which is potentially applicable for many magnetic resonance image (MRI)-guided musculoskeletal interventions. With this method, no switching between different planes is required, since the cross-sectional modality of the MRI is used as a new navigation approach. MATERIALS AND METHODS: This method was mainly evaluated in retrograde drilling of artificial osteochondral lesions of the talus as an example of difficult navigation in drill placement due to poor visualization with X-ray and complex anatomy. To accomplish this objective, a passive navigation device was constructed and evaluated in nine cadaveric ankle joint specimens. Feasibility and accuracy of navigated drillings were evaluated. RESULTS: The interactive high-field MR fluoroscopy and the passive aiming device allow precise drilling of osteochondral lesions of the talus, despite the complex anatomy of the ankle. Drillings could be performed with an accuracy of 1.6 mm. The drilling guide was safe and easy to handle. CONCLUSION: The MR-assisted retrograde drilling of osteochondral lesions may enable precise and safe treatment without radiation exposure. This passive navigation technique for MR fluoroscopy is potentially applicable for many orthopedic interventions and may present an alternative to other navigation methods. Especially, the treatment of pediatric and adolescent patients may benefit from the typical MRI properties.


Assuntos
Articulação do Tornozelo/cirurgia , Fluoroscopia/métodos , Imageamento por Ressonância Magnética/métodos , Doenças Musculoesqueléticas/cirurgia , Osteocondrite Dissecante/cirurgia , Cirurgia Assistida por Computador/métodos , Cartilagem Articular/cirurgia , Desenho de Equipamento , Humanos
11.
Radiology ; 252(3): 857-64, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19567649

RESUMO

The institutional review board approved the use of cadaveric specimens, and informed consent was obtained from all volunteers. The authors performed and assessed a magnetic resonance (MR)-assisted navigation method for minimally invasive retrograde drilling of talar osteochondral lesions. For this method, a single imaging plane is sufficient for navigation during intervention. To accomplish this objective, a passive MR navigation device was used to evaluate 16 cadaveric ankle joints. Use of this interactive MR-assisted navigation method in combination with a passive aiming device allowed precise and rapid retrograde drilling of talar osteochondral lesions.


Assuntos
Articulação do Tornozelo/cirurgia , Imagem por Ressonância Magnética Intervencionista , Osteocondrite/cirurgia , Tálus/cirurgia , Articulação do Tornozelo/patologia , Artefatos , Cadáver , Humanos , Osteocondrite/patologia , Tálus/patologia
12.
Magn Reson Med ; 61(3): 668-77, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19097236

RESUMO

Many cardiovascular diseases and disorders are associated with hemodynamic dysfunction. The heart's ability to contract and pump blood through the vascular system primarily depends on the elasticity of the myocardium. This article introduces a magnetic resonance elastography (MRE) technique that allows noninvasive and time-resolved measurement of changes in myocardial elasticity over the cardiac cycle. To this end, low-frequency shear vibrations of 24.3 Hz were induced in the human heart via the anterior chest wall. An electrocardiograph (ECG)-triggered, steady-state MRE sequence was used to capture shear oscillations with a frame rate of eight images per vibration cycle. The time evolution of 2D-shear wave fields was observed in two imaging planes through the short axis of the heart in six healthy volunteers. Correlation analysis revealed that wave amplitudes were modulated in synchrony to the heartbeat with up to 2.45 +/- 0.18 higher amplitudes during diastole than during systole (interindividual mean +/- SD). The reduction of wave amplitudes started at 75 +/- 9 ms prior to changes in left ventricular diameter occurring at the beginning of systole. Analysis of this wave amplitude alteration using a linear elastic constitutive model revealed a maximum change in the myocardial wall stiffness of a factor of 37.7 +/- 10.6 during the cardiac cycle.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Estresse Mecânico
13.
Magn Reson Imaging ; 26(2): 228-35, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18063338

RESUMO

Strain and motion measurements in balanced steady-state free precession (bSSFP) imaging require high magnetic field homogeneity. This requirement is due to the nonlinear signal response to spin phase variations in bSSFP. Here, a technique that utilizes background gradients for preparing strong in-plane spin phase variations is proposed. As a result, periodic patterns of increased motion sensitivity appear, which are interleaved with bands of low phase-to-noise ratio. Spatial filters commonly used in MR elastography (MRE) remove these bands and leave wave images equivalent to a uniform phase response in bSSFP-MRE. Since phase preparation gradients locally enhance motion sensitivity, the technique can be employed for selectively increasing the wave signal amplitude in MRE. The method is applied without the need for previous shimming, which reduces the examination time. In vivo phase prepared bSSFP-MRE is demonstrated in human liver and heart.


Assuntos
Elasticidade , Coração/fisiologia , Fígado/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Simulação por Computador , Eletrocardiografia , Humanos , Masculino , Imagens de Fantasmas
14.
Invest Radiol ; 41(12): 841-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17099421

RESUMO

OBJECTIVE: The objective of this study was to introduce an magnetic resonance elastography (MRE) protocol based on fractional motion encoding and planar wave acquisition for rapid measurements of in vivo human liver stiffness. MATERIALS AND METHODS: Vibrations of a remote actuator membrane were fed by a rigid rod to the patient's surface beneath the right costal arch resulting in axial shear deflections of the liver. Data acquisition was performed using a balanced steady-state free precession (bSSFP) sequence incorporating oscillating gradients for motion sensitization. Tissue vibrations of frequency fv = 51 Hz were tuned by twice the sequence repetition time (1/fv = 2TR). Twenty axial images acquired by time-resolved through-plane wave encoding were used for planar elasticity reconstruction. The MRE data acquisition was achieved within 4 breathholds of 17 seconds each. The method was applied to 12 healthy volunteers and 2 patients with diffuse liver disease (fibrosis grade 3). RESULTS: MRE data acquisition was successful in all volunteers and patients. The elastic moduli were measured with values between 1.99 +/- 0.16 and 5.77 +/- 0.88 kPa. Follow-up studies demonstrated the reproducibility of the method and revealed a difference of 0.74 +/- 0.47 kPa (P < 0.05) between the hepatic stiffness of 2 healthy male volunteers. CONCLUSION: bSSFP combined with fractional MRE enables rapid measurement of liver stiffness in vivo. The used actuation principle supports a 2-dimensional analysis of the strain wave field captured by axial wave images. The measured data indicate individual variations of hepatic stiffness in healthy volunteers.


Assuntos
Tecido Elástico/patologia , Elasticidade , Imageamento Tridimensional , Cirrose Hepática/diagnóstico , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Vibração
15.
Diagn Interv Radiol ; 20(3): 251-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24509185

RESUMO

PURPOSE: We aimed to validate actually achieved macroscopic ablation volumes in relation to calculated target volumes using four different radiofrequency ablation (RFA) systems operated with default settings and protocols for 3 cm and 5 cm target volumes in ex vivo bovine liver. MATERIALS AND METHODS: Sixty-four cuboid liver specimens were ablated with four commercially available RFA systems (Radionics Cool-tip, AngioDynamic 1500X, Boston Scientific RF 3000, Celon CelonPower LAB): 16 specimens for each system; eight for 3 cm, and eight for 5 cm. Ablation diameters were measured, volumes were calculated, and RFA times were recorded. RESULTS: For the 3 cm target ablation volume, all tested RFA systems exceeded the mathematically calculated volume of 14.14 cm3. For the 3 cm target ablation volume, mean ablation volume and mean ablation time for each RFA system were as follows: 28.5 ± 6.5 cm3, 12.0 ± 0.0 min for Radionics Cool-tip; 17.1 ± 4.9 cm3, 9.36 ± 0.63 min for AngioDynamic 1500X; 29.7 ± 11.7 cm3, 4.60 ± 0.50 min for Boston Scientific RF 3000; and 28.8 ± 7.0 cm3, 20.85 ± 0.86 min for Celon CelonPower LAB. For the 5 cm target ablation volume, Radionics Cool-tip (48.3 ± 9.9 cm3, 12.0 ± 0.0 min) and AngioDynamic 1500X (39.4 ± 16.2 cm3, 19.59 ± 1.13 min) did not reach the mathematically calculated target ablation volume (65.45 cm3), whereas Boston Scientific RF 3000 (71.8 ± 14.5 cm3, 9.15 ± 2.93 min) and Celon CelonPower LAB (93.9 ± 28.1 cm3, 40.21 ± 1.78 min) exceeded it. CONCLUSION: While all systems reached the 3 cm target ablation volume, results were variable for the 5 cm target ablation volume. Only Boston Scientific RF 3000 and Celon CelonPower LAB created volumes above the target, whereas Radionics Cool-tip and AngioDynamic 1500X remained below the target volume. For the 3 cm target ablation volume, AngioDynamic 1500X with 21% deviation was closest to the target volume. For the 5 cm target volume Boston Scientific RF 3000 with 10% deviation was closest.


Assuntos
Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Fígado/cirurgia , Animais , Bovinos , Desenho de Equipamento , Fígado/patologia , Modelos Biológicos , Modelos Estatísticos , Necrose , Fatores de Tempo
16.
Invest Radiol ; 48(6): 471-6, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23442776

RESUMO

OBJECTIVES: The objective of this study was to evaluate the accuracy, safety, and efficacy of magnetic resonance (MR)-guided periradicular nerve root injection therapy using an open 1.0-T magnetic resonance imaging (MRI) system with fast dynamic imaging. MATERIALS AND METHODS: Between April 2008 and November 2011, a total of 249 MR-guided periradicular nerve root injections were performed in 141 patients experiencing lumbosacral radicular pain. All interventions were performed in an open 1.0-T MRI system. An interactive proton-density-weighted fast spin-echo sequence was used for real-time guidance. An in-room monitor, a wireless MR mouse for operator-controlled multiplanar imaging, a flexible surface coil, and an MR-compatible 20-G needle were used. Informed consent was obtained from all patients. Clinical outcome was evaluated through clinical follow-up and a questionnaire before injection therapy (baseline) and 6 months after using a numeric visual analog scale. RESULTS: All procedures were technically successful. No major complications occurred. At 6 months, of the 103 patients (197 injections; 57 men, 46 women; mean age, 49.5 years; range, 20-80) who enrolled in the outcome analysis, 14.6% reported complete remission of radicular pain; 53.4%, significant relief of pain; 22.3%, mild relief; and 9.7%, no relief of pain. We found a significant decrease of the visual analog scale score from the preintervention compared with the follow-up after 6 months (P < 0.001). No significant difference in the outcome was observed between the patients with degenerative foraminal stenoses and the patients with herniated disks. CONCLUSIONS: Magnetic resonance fluoroscopy-guided periradicular injection therapy for the lumbosacral spine under open 1.0-T MRI guidance is accurate, safe, and efficient in the symptomatic treatment of radicular pain. This technique may be a promising alternative to fluoroscopy- or computed tomography-guided spinal injections in the lumbosacral region, especially for young patients and patients undergoing serial therapeutic regimens.


Assuntos
Bupivacaína/administração & dosagem , Dor Lombar/prevenção & controle , Imagem por Ressonância Magnética Intervencionista/métodos , Radiculopatia/tratamento farmacológico , Radiculopatia/patologia , Triancinolona Acetonida/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestésicos Locais/administração & dosagem , Anti-Inflamatórios/administração & dosagem , Sistemas Computacionais , Quimioterapia Combinada/métodos , Feminino , Humanos , Dor Lombar/etiologia , Região Lombossacral/patologia , Masculino , Pessoa de Meia-Idade , Radiculopatia/complicações , Resultado do Tratamento , Adulto Jovem
17.
Cardiovasc Intervent Radiol ; 35(1): 154-60, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21387122

RESUMO

PURPOSE: To evaluate the feasibility of minimally invasive magnetic resonance imaging (MRI)-guided free-hand aspiration of symptomatic nerve route compressing lumbosacral cysts in a 1.0-Tesla (T) open MRI system using a tailored interactive sequence. MATERIALS AND METHODS: Eleven patients with MRI-evident symptomatic cysts in the lumbosacral region and possible nerve route compressing character were referred to a 1.0-T open MRI system. For MRI interventional cyst aspiration, an interactive sequence was used, allowing for near real-time position validation of the needle in any desired three-dimensional plane. RESULTS: Seven of 11 cysts in the lumbosacral region were successfully aspirated (average 10.1 mm [SD ± 1.9]). After successful cyst aspiration, each patient reported speedy relief of initial symptoms. Average cyst size was 9.6 mm (±2.6 mm). Four cysts (8.8 ± 3.8 mm) could not be aspirated. CONCLUSION: Open MRI systems with tailored interactive sequences have great potential for cyst aspiration in the lumbosacral region. The authors perceive major advantages of the MR-guided cyst aspiration in its minimally invasive character compared to direct and open surgical options along with consecutive less trauma, less stress, and also less side-effects for the patient.


Assuntos
Cistos/cirurgia , Região Lombossacral , Imagem por Ressonância Magnética Intervencionista/métodos , Compressão da Medula Espinal/cirurgia , Raízes Nervosas Espinhais , Cistos/complicações , Estudos de Viabilidade , Feminino , Humanos , Masculino , Medição da Dor , Compressão da Medula Espinal/etiologia , Sucção , Resultado do Tratamento
18.
Cardiovasc Intervent Radiol ; 35(3): 661-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21629981

RESUMO

The aim of this study was to develop a signal-inducing bone cement for magnetic resonance imaging (MRI)-guided cementoplasty of the spine. This MRI cement would allow precise and controlled injection of cement into pathologic lesions of the bone. We mixed conventional polymethylmethacrylate bone cement (PMMA; 5 ml methylmethacrylate and 12 g polymethylmethacrylate) with hydroxyapatite (HA) bone substitute (2-4 ml) and a gadolinium-based contrast agent (CA; 0-60 µl). The contrast-to-noise ratio (CNR) of different CA doses was measured in an open 1.0-Tesla scanner for fast T1W Turbo-Spin-Echo (TSE) and T1W TSE pulse sequences to determine the highest signal. We simulated MRI-guided cementoplasty in cadaveric spines. Compressive strength of the cements was tested. The highest CNR was (1) 87.3 (SD 2.9) in fast T1W TSE for cements with 4 µl CA/ml HA (4 ml) and (2) 60.8 (SD 2.4) in T1W TSE for cements with 1 µl CA/ml HA (4 ml). MRI-guided cementoplasty in cadaveric spine was feasible. Compressive strength decreased with increasing amounts of HA from 46.7 MPa (2 ml HA) to 28.0 MPa (4 ml HA). An MRI-compatible cement based on PMMA, HA, and CA is feasible and clearly visible on MRI images. MRI-guided spinal cementoplasty using this cement would permit direct visualization of the cement, the pathologic process, and the anatomical surroundings.


Assuntos
Cimentos Ósseos/farmacologia , Durapatita/farmacologia , Aumento da Imagem/métodos , Imagem por Ressonância Magnética Intervencionista , Polimetil Metacrilato/farmacologia , Coluna Vertebral/cirurgia , Cadáver , Meios de Contraste/farmacologia , Humanos , Injeções Espinhais , Meglumina/farmacologia , Compostos Organometálicos/farmacologia , Estresse Mecânico
19.
Int J Comput Assist Radiol Surg ; 6(5): 713-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21416136

RESUMO

PURPOSE: The goal of this study was to investigate the impact of reduced k-space sampling rates on the visualization of a moving MR-compatible puncture needle and to demonstrate the feasibility of keyhole imaging in interventional magnetic resonance imaging (MRI). MATERIAL AND METHODS: All experiments were performed in an open 1.0 Tesla MRI. MR images of a moving puncture needle were taken with different keyhole sampling rates from 15-100%, in 10% increments. The needle was submerged in a water-filled basin and was imaged in motion with a T1-weighted gradient-echo sequence with an initial acquisition rate of 1.4 s per image. An apparatus operated by a compressor unit enabled needle rotation and ensured reproducible needle movements. The median forward velocity of the needle tip was 2 cm/s. To evaluate the depiction of the needle, artifact diameter of the needle, contrast-to-noise ratio (CNR), and needle tip profiles (delineation) were measured. RESULTS: The needle position was determined with an longitudinal error of 3 mm and a transverse error of 0.8 mm with respect to the needle's orientation and the theoretically calculated trajectory. No significant correlation was found between the CNR and velocity. A reduction of k-space update rates caused neither a significant reduction of CNR nor a significant increase in artifact diameter or blurring of the needle profile. CONCLUSION: The application of keyhole imaging with update rates of greater than 15% is sufficient for the MR guidance of interventions with an signal-to-noise ratio >9 of the surrounding tissue and a target accuracy of >1 mm. Keyhole imaging can increase temporal resolution while ensuring unimpaired spatial resolution and image quality of the depicted instrument.


Assuntos
Imagem por Ressonância Magnética Intervencionista/instrumentação , Agulhas , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Aceleração , Algoritmos , Desenho de Equipamento , Humanos , Imagem por Ressonância Magnética Intervencionista/métodos , Controle de Qualidade , Intensificação de Imagem Radiográfica/instrumentação , Sensibilidade e Especificidade
20.
Eur J Radiol ; 80(3): 856-60, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21227616

RESUMO

PURPOSE: Verification of MR-guidance with image acquisitions slower than 1 image per second as it is inevitable for some interventions. Therefore, we quantified solely the effect of acquisition-time on the efficiency of MR-guided interventions in a static phantom study. MATERIALS AND METHODS: We measured the duration, accuracy and error rate of simulated interventions for different acquisition-times using a simplified interventional setup. All measurements were performed in a 1.0 T open MRI scanner. Imaging was performed with a gradient-echo sequence (flipangle=20°; TR/TE=12/6 ms; voxelsize=1 mm×1 mm; slicethickness=5 mm; FOV=230 mm×200 mm; acquisition-time=1 s). Variable acquisition times were simulated with intermediate pauses of 0, 1, 2, 3, 4 and 5 s. The interventions were performed by a total of 20 volunteers including 7 experienced interventionalists. RESULTS: The mean duration of the intervention was 2 min. Significant differences between experienced and unexperienced volunteers were limited to the localization of the image plane and corrections made. The mean accuracy was 5.6 mm. The time to localize the image plane increased with deceleration of imaging from 24 s to 49 s. A similar increase was observed for the intervention time (55-108 s). A significant influence of the acquisition-time on durations and corrections was only found with acquisition-times greater than 4s per image. CONCLUSION: Even image rates of several seconds per image are sufficient enough for efficient interventions in static organs. Thus, the main attention has to be turned on the visibility of the needle when sequences are optimized for MR-guidance. The minimization of imaging speed is rather of secondary interest.


Assuntos
Imageamento por Ressonância Magnética/métodos , Punções/métodos , Cirurgia Assistida por Computador/métodos , Vísceras/anatomia & histologia , Vísceras/cirurgia , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA