Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anesthesiology ; 135(6): 1066-1075, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34644374

RESUMO

BACKGROUND: Experimental and pilot clinical data suggest that spontaneously breathing patients with sepsis and septic shock may present increased respiratory drive and effort, even in the absence of pulmonary infection. The study hypothesis was that respiratory drive and effort may be increased in septic patients and correlated with extrapulmonary determinant and that high-flow nasal cannula may modulate drive and effort. METHODS: Twenty-five nonintubated patients with extrapulmonary sepsis or septic shock were enrolled. Each patient underwent three consecutive steps: low-flow oxygen at baseline, high-flow nasal cannula, and then low-flow oxygen again. Arterial blood gases, esophageal pressure, and electrical impedance tomography data were recorded toward the end of each step. Respiratory effort was measured as the negative swing of esophageal pressure (ΔPes); drive was quantified as the change in esophageal pressure during the first 500 ms from start of inspiration (P0.5). Dynamic lung compliance was calculated as the tidal volume measured by electrical impedance tomography, divided by ΔPes. The results are presented as medians [25th to 75th percentile]. RESULTS: Thirteen patients (52%) were in septic shock. The Sequential Organ Failure Assessment score was 5 [4 to 9]. During low-flow oxygen at baseline, respiratory drive and effort were elevated and significantly correlated with arterial lactate (r = 0.46, P = 0.034) and inversely with dynamic lung compliance (r = -0.735, P < 0.001). Noninvasive support by high-flow nasal cannula induced a significant decrease of respiratory drive (P0.5: 6.0 [4.4 to 9.0] vs. 4.3 [3.5 to 6.6] vs. 6.6 [4.9 to 10.7] cm H2O, P < 0.001) and effort (ΔPes: 8.0 [6.0 to 11.5] vs. 5.5 [4.5 to 8.0] vs. 7.5 [6.0 to 12.6] cm H2O, P < 0.001). Oxygenation and arterial carbon dioxide levels remained stable during all study phases. CONCLUSIONS: Patients with sepsis and septic shock of extrapulmonary origin present elevated respiratory drive and effort, which can be effectively reduced by high-flow nasal cannula.


Assuntos
Cânula , Insuficiência Respiratória/fisiopatologia , Insuficiência Respiratória/terapia , Taxa Respiratória/fisiologia , Choque Séptico/fisiopatologia , Choque Séptico/terapia , Idoso , Estudos de Coortes , Impedância Elétrica/uso terapêutico , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Oxigenoterapia/instrumentação , Oxigenoterapia/métodos , Sepse/fisiopatologia , Sepse/terapia
2.
BMC Anesthesiol ; 19(1): 172, 2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31481006

RESUMO

Following publication of the original article [1], the authors reported that one of the co-authors has a mistake in the author name; the middle name and surname are switched. This is the correct information.

3.
BMC Anesthesiol ; 19(1): 140, 2019 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-31390977

RESUMO

BACKGROUND: Electrical impedance tomography (EIT) is a non-invasive radiation-free monitoring technique that provides images based on tissue electrical conductivity of the chest. Several investigations applied EIT in the context of perioperative medicine, which is not confined to the intraoperative period but begins with the preoperative assessment and extends to postoperative follow-up. MAIN BODY: EIT could provide careful respiratory monitoring in the preoperative assessment to improve preparation for surgery, during anaesthesia to guide optimal ventilation strategies and to monitor the hemodynamic status and in the postoperative period for early detection of respiratory complications. Moreover, EIT could further enhance care of patients undergoing perioperative diagnostic procedures. This narrative review summarizes the latest evidence on the application of this technique to the surgical patient, focusing also on possible future perspectives. CONCLUSIONS: EIT is a promising technique for the perioperative assessment of surgical patients, providing tailored adaptive respiratory and haemodynamic monitoring. Further studies are needed to address the current technological limitations, confirm the findings and evaluate which patients can benefit more from this technology.


Assuntos
Impedância Elétrica , Monitorização Fisiológica , Medicina Perioperatória , Tomografia , Capacidade Residual Funcional , Hemodinâmica , Humanos , Pulmão/irrigação sanguínea , Pulmão/fisiologia , Medidas de Volume Pulmonar , Imagem de Perfusão , Assistência Perioperatória , Respiração com Pressão Positiva , Atelectasia Pulmonar/prevenção & controle , Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA