Resultados 1 - 20 de 66
Filtrar
1.
Artif Organs ; 44(8): E326-E336, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32242944

RESUMO

Left ventricular assist devices (LVAD) provide cardiac support to patients with advanced heart failure. Methods that can directly measure remaining LV function following device implantation do not currently exist. Previous studies have shown that a combination of loading (LV pressure) and deformation (strain) measurements enables quantitation of myocardial work. We investigated the use of ultrasound (US) strain imaging and pressure-strain loop analysis in LVAD-supported hearts under different hemodynamic and pump unloading conditions, with the aim of determining LV function with and without LVAD support. Ex vivo porcine hearts (n = 4) were implanted with LVADs and attached to a mock circulatory loop. Measurements were performed at hemodynamically defined "heart conditions" as the hearts deteriorated from baseline. Hemodynamic (including LV pressure) and radio-frequency US data were acquired during a pump-ramp protocol at speeds from 0 (with no pump outflow) to 10 000 revolutions per minute (rpm). Regional circumferential (εcirc ) and radial (εrad ) strains were estimated over each heart cycle. Regional ventricular dyssynchrony was quantitated through time-to-peak strain. Mean change in LV pulse pressure and εcirc between 0 and 10 krpm were -21.8 mm Hg and -7.24% in the first condition; in the final condition -46.8 mm Hg and -19.2%, respectively. εrad was not indicative of changes in pump speed or heart condition. Pressure-strain loops showed a degradation in the LV function and an increased influence of LV unloading: loop area reduced by 90% between 0 krpm in the first heart condition and 10 krpm in the last condition. High pump speeds and degraded condition led to increased dyssynchrony between the septal and lateral LV walls. Functional measurement of the LV while undergoing LVAD support is possible by using US strain imaging and pressure-strain loops. This can provide important information about remaining pump function. Use of novel LV pressure estimation or measurement techniques would be required for any future use in LVAD patients.


Assuntos
Coração Auxiliar , Animais , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Hemodinâmica , Suínos , Função Ventricular Esquerda/fisiologia
2.
Am J Physiol Heart Circ Physiol ; 313(3): H558-H567, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28576835

RESUMO

Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R2 = 0.94) but underestimated wave reflection (correlation: 0.75, R2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health.NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor.


Assuntos
Aorta/fisiopatologia , Pressão Arterial , Ventrículos do Coração/fisiopatologia , Hipertensão/fisiopatologia , Modelos Cardiovasculares , Contração Miocárdica , Rigidez Vascular , Função Ventricular Esquerda , Pressão Ventricular , Animais , Velocidade do Fluxo Sanguíneo , Bovinos , Simulação por Computador , Módulo de Elasticidade , Hipertensão/etiologia , Modelos Anatômicos , Análise de Onda de Pulso , Fluxo Sanguíneo Regional , Silicones , Fatores de Tempo , Transdutores de Pressão
3.
J Med Biol Eng ; 36: 308-315, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27441034

RESUMO

Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

4.
Artif Organs ; 39(11): 931-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25940920

RESUMO

The blood pressure changes induced by the intra-aortic balloon pump (IABP) are expected to create clinical improvement in terms of coronary perfusion and myocardial oxygen consumption. However, the measured effects reported in literature are inconsistent. The aim of this study was to investigate the influence of ischemia on IABP efficacy in healthy hearts and in shock. Twelve slaughterhouse porcine hearts (hearts 1-12) were connected to an external circulatory system, while physiologic cardiac performance was restored. Different clinical scenarios, ranging from healthy to cardiogenic shock, were simulated by step-wise administration of negative inotropic drugs. In hearts 7-12, severe global myocardial ischemia superimposed upon the decreased contractile states was created. IABP support was applied in all hearts under all conditions. Without ischemia, the IABP induced a mild increase in coronary blood flow and cardiac output. These effects were strongly augmented in the presence of persisting ischemia, where coronary blood flow increased by 49 ± 24% (P < 0.01) and cardiac output by 17 ± 6% (P < 0.01) in case of severe pump failure. As expected, myocardial oxygen consumption increased in case of ischemia (21 ± 17%; P < 0.01), while it slightly decreased without (-3 ± 6%; P < 0.01). In case of progressive pump failure due to persistent myocardial ischemia, the IABP increased hyperemic coronary blood flow and cardiac output significantly, and reversed the progressive hemodynamic deterioration within minutes. This suggests that IABP therapy in acute myocardial infarction is most effective in patients with viable myocardium, suffering from persistent myocardial ischemia, despite adequate epicardial reperfusion.


Assuntos
Coração/fisiologia , Balão Intra-Aórtico/métodos , Isquemia Miocárdica/fisiopatologia , Animais , Pressão Sanguínea/fisiologia , Circulação Coronária/fisiologia , Falha de Equipamento , Hemodinâmica/fisiologia , Miocárdio/metabolismo , Consumo de Oxigênio , Suínos
5.
Artif Organs ; 37(6): 531-40, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23278527

RESUMO

We considered a mathematical model to investigate changes in geometric and hemodynamic indices of left ventricular function in response to changes in myofiber contractility and myocardial tissue stiffness during rotary blood pump support. Left ventricular assistance with a rotary blood pump was simulated based on a previously published biventricular model of the assisted heart and circulation. The ventricles in this model were based on the one-fiber model that relates ventricular function to myofiber contractility and myocardial tissue stiffness. The simulations showed that indices of ventricular geometry, left ventricular shortening fraction, and ejection fraction had the same response to variations in myofiber contractility and myocardial tissue stiffness. Hemodynamic measures showed an inverse relation compared with geometric measures. Particularly, pulse pressure and arterial dP/dtmax increased when myofiber contractility increased, whereas increasing myocardial tissue stiffness decreased these measures. Similarly, the lowest pump speed at which the aortic valve remained closed increased when myofiber contractility increased and decreased when myocardial tissue stiffness increased. Therefore, simultaneous monitoring of hemodynamic parameters and ventricular geometry indirectly reflects the status of the myocardial tissue. The appropriateness of this strategy will be evaluated in the future, based on in vivo studies.


Assuntos
Contração Miocárdica/fisiologia , Miocárdio , Disfunção Ventricular Esquerda/fisiopatologia , Pressão Sanguínea , Coração Auxiliar , Hemodinâmica , Humanos , Modelos Cardiovasculares , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/cirurgia , Função Ventricular Esquerda/fisiologia
6.
Artif Organs ; 37(8): 724-30, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23489228

RESUMO

The isolated beating pig heart model is an accessible platform to investigate the coronary circulation in its truly morphological and physiological state, whereas its use is beneficial from a time, cost, and ethical perspective. However, whether the coronary autoregulation is still intact is not known. Here, we study the autoregulation of coronary blood flow in the working isolated pig heart in response to brief occlusions of the coronary artery, to step-wise changes in left ventricular loading conditions and contractile states, and to pharmacologic vasodilating stimuli. Six slaughterhouse pig hearts (473 ± 40 g) were isolated, prepared, and connected to an external circulatory system. Through coronary reperfusion and controlled cardiac loading, physiological cardiac performance was achieved. After release of a coronary occlusion, coronary blood flow rose rapidly to an equal (maximum) level as the flow during control beats, independent of the duration of occlusion. Moreover, a linear relation was found between coronary blood flow and coronary driving pressure for a wide variation of preload, afterload, and contractility. In addition, intracoronary administration of papaverine did not yield a transient increase in blood flow indicating the presence of maximum coronary hyperemia. Together, this indicates that the coronary circulation in the isolated beating pig heart is in a permanent state of maximum hyperemia. This makes the model excellently suitable for testing and validating cardiovascular devices (i.e., heart valves, stent grafts, and ventricular assist devices) under well-controlled circumstances, whereas it decreases the necessity of sacrificing large mammalians for performing classical animal experiments.


Assuntos
Circulação Coronária , Vasos Coronários/fisiologia , Coração/fisiologia , Homeostase , Animais , Hemodinâmica , Suínos
7.
Ultrasonics ; 135: 107127, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37573737

RESUMO

Cardiovascular strain imaging is continually improving due to ongoing advances in ultrasound acquisition and data processing techniques. The phantoms used for validation of new methods are often burdensome to make and lack flexibility to vary mechanical and acoustic properties. Simulations of US imaging provide an alternative with the required flexibility and ground truth strain data. However, the current Lagrangian US strain imaging models cannot simulate heterogeneous speed of sound distributions and higher-order scattering, which limits the realism of the simulations. More realistic Eulerian modelling techniques exist but have so far not been used for strain imaging. In this research, a novel sampling scheme was developed based on a band-limited interpolation of the medium, which enables accurate strain simulation in Eulerian methods. The scheme was validated in k-Wave using various numerical phantoms and by a comparison with Field II. The method allows for simulations with a large range in strain values and was accurate with errors smaller than -60 dB. Furthermore, an excellent agreement with the Fourier theory of US scattering was found. The ability to perform simulations with heterogeneous speed of sound distributions was demonstrated using a pulsating artery model. The developed sampling scheme contributes to more realistic strain imaging simulations, in which the effect of heterogenous acoustic properties can be taken into account.


Assuntos
Acústica , Artérias , Ultrassonografia , Simulação por Computador , Imagens de Fantasmas
8.
ASAIO J ; 69(5): e192-e198, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36913553

RESUMO

Mechanical heart valve (MHV) prostheses present a risk of thromboembolic complications despite antithrombotic therapy. Further steps in the development of more hemocompatible MHVs and new anticoagulants are impeded due to the lack of adequate in-vitro models. With the development of a novel in-vitro model (MarioHeart), a pulsatile flow similar to the arterial circulation is emulated. The MarioHeart design owns unique features as 1) a single MHV within a torus with low surface/volume ratio, 2) a closed loop system, and 3) a dedicated external control system driving the oscillating rotational motion of the torus. For verification purposes, a blood analog fluid seeded with particles was used to assess fluid velocity and flow rate using a speckle tracking method on high-speed video recordings of the rotating model. The flow rate resembled the physiological flow rate in the aortic root, in both shape and amplitude. Additional in-vitro runs with porcine blood showed thrombi on the MHV associated with the suture ring, which is similar to the in-vivo situation. MarioHeart is a simple design which induces well-defined fluid dynamics resulting in physiologically nonturbulent flow without stasis of the blood. MarioHeart seems suitable for testing the thrombogenicity of MHVs and the potential of new anticoagulants.


Assuntos
Próteses Valvulares Cardíacas , Animais , Suínos , Velocidade do Fluxo Sanguíneo/fisiologia , Desenho de Prótese , Fluxo Pulsátil/fisiologia , Movimento (Física) , Modelos Cardiovasculares , Valva Aórtica
9.
Front Cardiovasc Med ; 10: 1161779, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37529710

RESUMO

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

10.
J Biomed Opt ; 27(9)2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36104838

RESUMO

SIGNIFICANCE: Physics-based simulations of photoacoustic (PA) signals are used to validate new methods, to characterize PA setups and to generate training datasets for machine learning. However, a thoroughly validated PA simulation toolchain that can simulate realistic images is still lacking. AIM: A quantitative toolchain was developed to model PA image acquisition in complex tissues, by simulating both the optical fluence and the acoustic wave propagation. APPROACH: Sampling techniques were developed to decrease artifacts in acoustic simulations. The performance of the simulations was analyzed by measuring the point spread function (PSF) and using a rotatable three-channel phantom, filled with cholesterol, a human carotid plaque sample, and porcine blood. Ex vivo human plaque samples were simulated to validate the methods in more complex tissues. RESULTS: The sampling techniques could enhance the quality of the simulated PA images effectively. The resolution and intensity of the PSF in the turbid medium matched the experimental data well. Overall, the appearance, signal-to-noise ratio and speckle of the images could be simulated accurately. CONCLUSIONS: A PA toolchain was developed and validated, and the results indicate a great potential of PA simulations in more complex and heterogeneous media.


Assuntos
Técnicas Fotoacústicas , Animais , Simulação por Computador , Humanos , Imagens de Fantasmas , Técnicas Fotoacústicas/métodos , Razão Sinal-Ruído , Análise Espectral , Suínos
11.
Artif Organs ; 35(9): 893-901, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21819436

RESUMO

The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support capabilities of both the IABP and the Impella 2.5 LP strongly depended on the simulated hemodynamic conditions. Maximum hemodynamic benefits were achieved when mechanical circulatory support was applied on a simulated scenario of deep CS.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Balão Intra-Aórtico , Choque Cardiogênico/cirurgia , Débito Cardíaco , Hemodinâmica , Humanos , Modelos Biológicos , Choque Cardiogênico/fisiopatologia
12.
Med Eng Phys ; 90: 66-81, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33781481

RESUMO

Current aortic stenosis severity grading is based mainly on the local properties of the stenotic valve, such as pressure gradient or jet velocity. Success rates of valve replacement therapy are still suboptimal, so alternative grading of AS should be investigated. We suggest the efficiency of power transfer from the left ventricle to the aorta, as it takes into account heart, valve and circulatory system. Left ventricular and circulatory power were estimated using a 0D model, which was optimised to patient data: left ventricular and aortic pressure, aortic flow and diastolic left ventricular volume. Optimisation was performed using a data assimilation method. These data were available in rest as well as chemically induced exercise for twelve patients. Using this limited data set, we showed that aortic valve efficiency is highly heterogeneous between patients, but also often dependent on the haemodynamic load. This indicates that power transfer efficiency is a highly interesting metric for further research in aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Aorta , Valva Aórtica , Ventrículos do Coração , Hemodinâmica , Humanos , Função Ventricular Esquerda
13.
Int J Numer Method Biomed Eng ; 36(10): e3388, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32691507

RESUMO

Patient outcome in trans-aortic valve implantation (TAVI) therapy partly relies on a patient's haemodynamic properties that cannot be determined from current diagnostic methods alone. In this study, we predict changes in haemodynamic parameters (as a part of patient outcome) after valve replacement treatment in aortic stenosis patients. A framework to incorporate uncertainty in patient-specific model predictions for decision support is presented. A 0D lumped parameter model including the left ventricle, a stenotic valve and systemic circulatory system has been developed, based on models published earlier. The unscented Kalman filter (UKF) is used to optimize model input parameters to fit measured data pre-intervention. After optimization, the valve treatment is simulated by significantly reducing valve resistance. Uncertain model parameters are then propagated using a polynomial chaos expansion approach. To test the proposed framework, three in silico test cases are developed with clinically feasible measurements. Quality and availability of simulated measured patient data are decreased in each case. The UKF approach is compared to a Monte Carlo Markov Chain (MCMC) approach, a well-known approach in modelling predictions with uncertainty. Both methods show increased confidence intervals as measurement quality decreases. By considering three in silico test-cases we were able to show that the proposed framework is able to incorporate optimization uncertainty in model predictions and is faster and the MCMC approach, although it is more sensitive to noise in flow measurements. To conclude, this work shows that the proposed framework is ready to be applied to real patient data.


Assuntos
Estenose da Valva Aórtica , Simulação por Computador , Cadeias de Markov , Incerteza , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Resultado do Tratamento
14.
Biomech Model Mechanobiol ; 19(5): 1585-1594, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31980973

RESUMO

Accurate estimation of mechanical properties of the different atherosclerotic plaque constituents is important in assessing plaque rupture risk. The aim of this study was to develop an experimental set-up to assess material properties of vascular tissue, while applying physiological loading and being able to capture heterogeneity. To do so, a ring-inflation experimental set-up was developed in which a transverse slice of an artery was loaded in the radial direction, while the displacement was estimated from images recorded by a high-speed video camera. The performance of the set-up was evaluated using seven rubber samples and validated with uniaxial tensile tests. For four healthy porcine carotid arteries, material properties were estimated using ultrasound strain imaging in whole-vessel-inflation experiments and compared to the properties estimated with the ring-inflation experiment. A 1D axisymmetric finite element model was used to estimate the material parameters from the measured pressures and diameters, using a neo-Hookean and Holzapfel-Gasser-Ogden material model for the rubber and porcine samples, respectively. Reproducible results were obtained with the ring-inflation experiment for both rubber and porcine samples. Similar mean stiffness values were found in the ring-inflation and tensile tests for the rubber samples as 202 kPa and 206 kPa, respectively. Comparable results were obtained in vessel-inflation experiments using ultrasound and the proposed ring-inflation experiment. This inflation set-up is suitable for the assessment of material properties of healthy vascular tissue in vitro. It could also be used as part of a method for the assessment of heterogeneous material properties, such as in atherosclerotic plaques.


Assuntos
Vasos Sanguíneos/fisiologia , Animais , Fenômenos Biomecânicos/fisiologia , Artérias Carótidas/fisiologia , Fricção , Modelos Cardiovasculares , Imagens de Fantasmas , Pressão , Reprodutibilidade dos Testes , Suínos , Resistência à Tração
15.
J Med Ultrason (2001) ; 47(1): 47-56, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31701347

RESUMO

PURPOSE: In dynamic musculoskeletal sonography, probe fixation can contribute to field of view (FOV) consistency, which is necessary for valid analysis of architectural parameters. In this volunteer study, the achieved FOV consistency in fixated ultrasonography was quantified and compared with freehand acquisition. METHODS: During five resting periods during cycling exercise, longitudinal B-mode images of the vastus lateralis (VL) muscle were acquired on one thigh with a fixated probe, and by two trained observers on the other thigh. In each acquisition, the structural similarity compared to the first resting period was determined using the complex wavelet structural similarity index (CW-SSIM). Also, the pennation angle of the VL was measured. Both CW-SSIM and pennation angle were compared between fixated and freehand acquisition. Furthermore, the compression of tissue by the probe fixation was measured. RESULTS: In fixated acquisition, a significantly higher structural similarity (p < 0.05) and an improved repeatability of pennation angle measurement were obtained compared to freehand acquisition. Probe fixation compressed muscle tissue by 12% on average. CONCLUSIONS: Quantification of the structural similarity showed an increase in FOV consistency with sonography compared to freehand acquisition. The demonstrated feasibility of long-term fixated acquisition might be attractive in many medical fields and sports, and for reduction of work-related ergonomic problems among sonographers.


Assuntos
Exercício Físico , Músculo Quadríceps/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
16.
EuroIntervention ; 16(7): 591-599, 2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-31085504

RESUMO

AIMS: The aim of this study was to validate novel software to calculate vessel fractional flow reserve (vFFR) based on 3D-QCA and to assess inter-observer variability in patients who underwent routine preprocedural FFR assessment for intermediate coronary artery stenosis. METHODS AND RESULTS: In vitro validation was performed in an experimental model. Clinical validation was performed in an observational, retrospective, single-centre cohort study. A total of 100 patients presenting with stable angina or non-ST-segment elevation myocardial infarction and an indication to perform FFR between January 2016 and October 2016 were included. vFFR was calculated based on the aortic root pressure along with two angiographic projections and validated against pressure wire-derived FFR. Mean FFR and vFFR were 0.82±0.08 and 0.84±0.07, respectively. A good linear correlation was found between FFR and vFFR (r=0.89; p<0.001). Assessment of vFFR had a low inter-observer variability (r=0.95; p<0.001). The diagnostic accuracy of vFFR in identifying lesions with an FFR ≤0.80 was higher as compared with 3D-QCA: AUC 0.93 (95% CI: 0.88-0.97) vs 0.66 (95% CI: 0.55-0.77), respectively. CONCLUSIONS: The 3D-QCA-derived vFFR has a high linear correlation to invasively measured FFR, a high diagnostic accuracy to detect FFR ≤0.80 and a low inter-observer variability.


Assuntos
Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Estudos de Coortes , Angiografia Coronária , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Software
17.
Artif Organs ; 33(8): 593-603, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19558561

RESUMO

Continuous flow ventricular assist devices (VADs) for mechanical circulatory support (MCS) are generally smaller and believed to be more reliable than pulsatile VADs. However, regarding continuous flow, there are concerns about the decreased pulsatility and ventricular unloading. Moreover, pulsatile VADs offer a wider range in control strategies. For this reason, we used a computer model to evaluate whether pulsatile operation of a continuous flow VAD would be more beneficial than the standard constant pump speed. The computer model describes the left and right ventricle with one-fiber heart contraction models, and the systemic, pulmonary, and coronary circulation with lumped parameter hemodynamical models, while the heart rate is regulated with a baroreflex model. With this computer model, both normal and heart failure hemodynamics were simulated. A HeartMate II left ventricular assist device model was connected to this model, and both constant speed and pulsatile support were simulated. Pulsatile support did not solve the decreased pulsatility issue, but it did improve perfusion (cardiac index and coronary flow) and unloading (stroke work and heart rate) compared with constant speed. Also, pulsatile support would be beneficial for developing control strategies, as it offers more options to adjust assist device settings to the patient's needs. Because the mathematical model used in this study can simulate different assist device settings, it can play a valuable role in developing mechanical circulatory support control strategies.


Assuntos
Simulação por Computador , Coração Auxiliar , Hemodinâmica , Modelos Cardiovasculares , Humanos , Fluxo Pulsátil
18.
J Biomech ; 41(2): 284-91, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18031750

RESUMO

Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dimensional wave propagation models of the arterial system can be used to provide boundary conditions for fully three-dimensional fluid-structure interaction computations that are usually defined in the time domain. In this study, a time-domain-based one-dimensional wave propagation model in a cross-sectional area, flow and pressure (A,q,p)-formulation is developed. Using this formulation, a constitutive law that includes viscoelasticity based on the mechanical behaviour of a Kelvin body, is introduced. The resulting pressure and flow waves travelling through a straight and tapered vessel are compared to experimental data obtained from measurements in an in vitro setup. The model presented shows to be well suited to predict wave propagation through these straight and tapered vessels with viscoelastic wall properties and hereto can serve as a time-domain-based method to model wave propagation in the human arterial system.


Assuntos
Algoritmos , Artérias/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Modelos Cardiovasculares , Animais , Simulação por Computador , Elasticidade , Humanos , Viscosidade
19.
Biomech Model Mechanobiol ; 7(2): 127-37, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17492322

RESUMO

The objective of this work was to determine the linear and non-linear viscoelastic behavior of abdominal aortic aneurysm thrombus and to study the changes in mechanical properties throughout the thickness of the thrombus. Samples are gathered from thrombi of seven patients. Linear viscoelastic data from oscillatory shear experiments show that the change of properties throughout the thrombus is different for each thrombus. Furthermore the variations found within one thrombus are of the same order of magnitude as the variation between patients. To study the non-linear regime, stress relaxation experiments are performed. To describe the phenomena observed experimentally, a non-linear multimode model is presented. The parameters for this model are obtained by fitting this model successfully to the experiments. The model cannot only describe the average stress response for all thrombus samples but also the highest and lowest stress responses. To determine the influence on the wall stress of the behavior observed the model proposed needs to implemented in the finite element wall stress analysis.


Assuntos
Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Trombose/fisiopatologia , Elasticidade , Humanos , Técnicas In Vitro , Dinâmica não Linear , Estresse Mecânico
20.
Biorheology ; 45(6): 651-61, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19065012

RESUMO

Physiological wall shear rates and stresses in vessel culture or tissue engineering are relevant for maintaining endothelial cell (EC) integrity. To this end, the culture medium should have an appropriate viscosity. The viscosity of a standard culture medium was increased using xanthan gum (XG) and compared with literature data on whole blood, resulting in a medium with blood-analog shear-thinning behavior (XG-medium). The measured osmolality of the XG-medium was 285+/-2 mOsm kg(-1), which is within a physiologically acceptable range. The XG-medium was compared to standard medium to verify whether XG alters vascular cell function. First, the effect of XG on the growth of human EC monolayers was determined. In addition, to study whether XG changes drug-induced vasoconstriction or endothelium-dependent vasodilation, different drugs were administered to porcine coronary artery rings in a solution with or without XG, measuring the isometric force developed. XG did not influence EC growth, nor did it change drug-induced vascular tone. Moreover, the ECs aligned in the direction of flow after 24 h of physiological shearing with XG-medium. We conclude that, unlike standard culture media, XG-medium as a blood-analog culture medium has rheological properties suitable for use in vessel culture and tissue engineering to induce physiological wall shear stresses at physiological flow rates.


Assuntos
Vasos Sanguíneos/fisiologia , Viscosidade Sanguínea , Meios de Cultura , Células Endoteliais/citologia , Humanos , Concentração Osmolar , Polissacarídeos Bacterianos , Reologia , Técnicas de Cultura de Tecidos , Engenharia Tecidual/métodos , Viscosidade