Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sci Total Environ ; 882: 163566, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37084905

RESUMO

Radon is a carcinogenic compound, and is particularly concerning in the education sector, where children and teachers may be exposed even longer than at home. Thus, this study intended to characterise radon in the indoor air of scholar environments in different provinces/districts of the Euroregion Galicia-Norte de Portugal. With a pioneering approach, this study evaluated the influence of specific factors/characteristics (location, type of management, construction material, season and floor within the building) and quantified their relative contribution to indoor radon levels. Radon was continuously monitored in 416 classrooms from school buildings located in urban and rural sites from different provinces/districts both in the regions of Galicia (A Coruña and Lugo provinces) and Portugal (Porto and Bragança districts), considering rooms for different age groups (from nursery schools to universities). Single and multivariate linear regression models were built considering the radon concentrations as the outcome variable and different room/building characteristics as predictor variables. Mean and median radon concentrations were 332 Bq·m-3 and 181 Bq·m-3, respectively. The radon concentrations observed are a public health concern, as almost 1/3 of the places monitored exceeded the reference limit value of the European legislation (300 Bq·m-3). Moreover, around 50 % of the indoor levels measured could be attributed to room/building characteristics: the building's location and the main construction material, as well as the occupants' age group, the floor within the building and the school's type of management (public/private). This study concluded that radon testing is needed in all school buildings and classrooms without exceptions. Thus, public administrations are urged to dedicate funds for testing, mitigation and public dissemination initiatives in schools. A special protocol for radon sampling in school buildings should also be developed.


Assuntos
Poluição do Ar em Ambientes Fechados , Radônio , Instituições Acadêmicas , Portugal , Espanha , Radônio/análise , Poluentes Atmosféricos/análise , Estações do Ano , Valores de Referência
2.
Artigo em Inglês | MEDLINE | ID: mdl-28561795

RESUMO

Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO2, CO, NO2, O3, CH2O, total volatile organic compounds (VOC), PM1, PM2.5, PM10, Total Suspended Particles (TSP) and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO) were found for PM2.5, PM10, CO2 and CH2O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO2. However, mitigation measures were not always sufficient to decrease the pollutants' concentrations till values considered safe to protect human health.


Assuntos
Poluição do Ar em Ambientes Fechados/prevenção & controle , Berçários para Lactentes , Instituições Acadêmicas , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/economia , Dióxido de Carbono/análise , Monóxido de Carbono/análise , Custos e Análise de Custo , Monitoramento Ambiental , Formaldeído/análise , Dióxido de Nitrogênio/análise , Ozônio/análise , Material Particulado/análise , Radônio/análise , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA