Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Adv Exp Med Biol ; 1232: 347-354, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31893430

RESUMO

In preterm infants, there is a risk of long-term cognitive, motor and behavioral impairments due to hemorrhagic and/or ischemic lesions. If detected early, lesions can be prevented. A bedside imaging modality, capable of early detection of both disorders, is necessary. We present the state of development of a tomographic imager (named Pioneer), that will be capable of determining the oxygenation of the preterm-infant brain with high spatial resolution. Pioneer is a time-resolved near-infrared optical tomography (TR NIROT) instrument. It employs multiple wavelength laser light in short pulses on 11 distinct locations and measures the re-emerging light in a contactless fashion by means of a time-correlated single-photon counting (TCSPC) camera (named Piccolo) covering ~4.9 cm2 with 300 detectors. Timing response of the entire system is 116 ps. An in-house designed biocompatible source ring ensures fixed relative positions of sources and detectors and provides a secure interface between the patient and the probe. At the present state, the NIROT Pioneer system successfully detected a 6x6x50 mm3 inclusion 3 cm deep inside a phantom. These results confirm that the Pioneer imager is working as expected and is on a solid path towards full 3D tissue oxygenation imaging.


Assuntos
Encéfalo , Recém-Nascido Prematuro , Oximetria , Oxigênio , Encéfalo/diagnóstico por imagem , Humanos , Recém-Nascido , Oximetria/instrumentação , Oximetria/métodos , Oximetria/normas , Oxigênio/metabolismo , Imagens de Fantasmas
2.
Phys Rev Lett ; 123(19): 192302, 2019 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-31765208

RESUMO

Virtual Compton scattering on the proton has been investigated at three yet unexplored values of the four-momentum transfer Q^{2}: 0.10, 0.20, and 0.45 GeV^{2}, at the Mainz Microtron. Fits performed using either the low-energy theorem or dispersion relations allowed the extraction of the structure functions P_{LL}-P_{TT}/ε and P_{LT}, as well as the electric and magnetic generalized polarizabilities α_{E1}(Q^{2}) and ß_{M1}(Q^{2}). These new results show a smooth and rapid falloff of α_{E1}(Q^{2}), in contrast to previous measurements at Q^{2}=0.33 GeV^{2}, and provide for the first time a precise mapping of ß_{M1}(Q^{2}) in the low-Q^{2} region.

3.
Adv Exp Med Biol ; 1072: 165-169, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30178340

RESUMO

Oxygenation of a tumor is one of the most important predictive factors: hypoxia is associated with aggressive tumors and substantially lower survival rate. Despite this high relevance of tumor oxygenation, there is currently no bedside technique available to measure it in clinical routine care. The aim of this work is to determine the oxygenation of tissue in mice by a continuous wave multispectral near-infrared optical tomograph (mNIROT). Tomographic reconstructions were processed by a massively modified NIRFAST software. We quantitatively measured the tissue oxygen saturation of the tumors in 4 BALB/c nude, female mice with human colon carcinoma cancer cells DLD-1 KRASwt injected subcutaneously. The study revealed changes of oxygenation in tumors on the long-term.


Assuntos
Neoplasias Experimentais/irrigação sanguínea , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Tomografia Óptica/métodos , Hipóxia Tumoral/fisiologia , Animais , Linhagem Celular Tumoral , Feminino , Xenoenxertos , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Consumo de Oxigênio/fisiologia
4.
Phys Rev Lett ; 114(23): 232501, 2015 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-26196794

RESUMO

At the Mainz Microtron MAMI, the first high-resolution pion spectroscopy from decays of strange systems was performed by electron scattering off a (9)Be target in order to study the Λ binding energy of light hypernuclei. Positively charged kaons were detected by a short-orbit spectrometer with a broad momentum acceptance at 0° forward angles with respect to the beam, efficiently tagging the production of strangeness in the target nucleus. Coincidentally, negatively charged decay pions were detected by two independent high-resolution spectrometers. About 10(3) pionic weak decays of hyperfragments and hyperons were observed. The pion momentum distribution shows a monochromatic peak at pπ≈133 MeV/c, corresponding to the unique signature for the two-body decay of hyperhydrogen Λ(4)H→(4)He+π(-), stopped inside the target. Its Λ binding energy was determined to be BΛ=2.12±0.01 (stat)±0.09 (syst)MeV with respect to the (3)H+Λ mass.

5.
Phys Rev Lett ; 112(22): 221802, 2014 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-24949757

RESUMO

A massive, but light, Abelian U(1) gauge boson is a well-motivated possible signature of physics beyond the standard model of particle physics. In this Letter, the search for the signal of such a U(1) gauge boson in electron-positron pair production at the spectrometer setup of the A1 Collaboration at the Mainz Microtron is described. Exclusion limits in the mass range of 40 MeV/c^{2} to 300 MeV/c^{2}, with a sensitivity in the squared mixing parameter of as little as ε^{2}=8×10^{-7} are presented. A large fraction of the parameter space has been excluded where the discrepancy of the measured anomalous magnetic moment of the muon with theory might be explained by an additional U(1) gauge boson.

6.
Phys Rev Lett ; 111(13): 132504, 2013 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-24116774

RESUMO

A measurement of beam helicity asymmetries in the reaction 3He[over →](e[over →],e'n)pp is performed at the Mainz Microtron in quasielastic kinematics to determine the electric to magnetic form factor ratio of the neutron GEn/GMn at a four-momentum transfer Q2=1.58 GeV2. Longitudinally polarized electrons are scattered on a highly polarized 3He gas target. The scattered electrons are detected with a high-resolution magnetic spectrometer, and the ejected neutrons are detected with a dedicated neutron detector composed of scintillator bars. To reduce systematic errors, data are taken for four different target polarization orientations allowing the determination of GEn/GMn from a double ratio. We find µnGEn/GMn=0.250±0.058(stat)±0.017(syst).

7.
Phys Rev Lett ; 106(25): 251802, 2011 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-21770630

RESUMO

A new exclusion limit for the electromagnetic production of a light U(1) gauge boson γ' decaying to e + e- was determined by the A1 Collaboration at the Mainz Microtron. Such light gauge bosons appear in several extensions of the standard model and are also discussed as candidates for the interaction of dark matter with standard model matter. In electron scattering from a heavy nucleus, the existing limits for a narrow state coupling to e + e- were reduced by nearly an order of magnitude in the range of the lepton pair mass of 210 MeV/c2}

8.
Phys Rev Lett ; 105(24): 242001, 2010 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-21231520

RESUMO

New precise results of a measurement of the elastic electron-proton scattering cross section performed at the Mainz Microtron MAMI are presented. About 1400 cross sections were measured with negative four-momentum transfers squared up to Q² = 1 (GeV/c)² with statistical errors below 0.2%. The electric and magnetic form factors of the proton were extracted by fits of a large variety of form factor models directly to the cross sections. The form factors show some features at the scale of the pion cloud. The charge and magnetic radii are determined to be ½ = 0.879(5)stat(4)syst(2)model(4)group fm and ½ = 0.777(13)stat(9)syst(5)model(2)group fm.

9.
Phys Rev Lett ; 99(13): 132301, 2007 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-17930579

RESUMO

The beam-recoil double polarization P(x')(h) and P(z')(h) and the recoil polarization P(y') were measured for the first time for the p(e,e'p)eta reaction at a four-momentum transfer of Q(2) = 0.1 GeV(2)/c(2) and a center of mass production angle of theta = 120 degrees at the Mainz Microtron MAMI-C. With a center of mass energy range of 1500 MeV

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA