Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Scand J Clin Lab Invest ; 82(2): 143-149, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35112642

RESUMO

BACKGROUND: Viscoelastic tests (rotational thromboelastometry, ROTEM®), together with the implementation of a specific algorithm for coagulation management in cardiac surgery, enable perioperative coagulopathy to be better controlled. METHODS: Retrospective cohort study including 675 patients who underwent cardiac surgery with cardiopulmonary bypass. The incidence of allogeneic blood transfusions and clinical postoperative complications were analyzed before and after ROTEM® implementation. RESULTS: Following viscoelastic testing and the implementation of a specific algorithm for coagulation management, the incidence of any allogeneic blood transfusion decreased (41.4% vs 31.9%, p = .026) during the perioperative period. In the group monitored with ROTEM®, decreased incidence of transfusion was observed for packed red blood cells (31.3% vs 19.8%, p = .002), fresh frozen plasma (9.8% vs 3.8%, p = .008), prothrombin complex concentrate administration (0.9% vs 0.3%, p = .599) and activated recombinant factor VII (0.3% vs 0.0%, p = .603). Increased incidence was observed for platelet transfusion (4.8% vs 6.8%, p = .530) and fibrinogen concentrate (0.9% vs 3.5%, p = .066), tranexamic acid (0.0% vs 0.6%, p = .370) and protamine administration (0.6% vs 0.9%, p = .908). Similar results were observed in the postoperative period, but with a decreased incidence of platelet transfusion (4.8% vs 3.8%, p = .813). In addition, statistically significant reductions were detected in the incidence of postoperative bleeding (9.5% vs 5.3%, p = .037), surgical reexploration (6.0% vs 2.9%, p = .035), and length of Intensive Care Unit (ICU) stay (6.0 days vs 5.3 days, p = .026). CONCLUSIONS: The monitoring of hemostasis by ROTEM® in cardiac surgery, was associated with decreased incidence of allogeneic blood transfusion, clinical hematologic postoperative complications and lengths of ICU stay.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tromboelastografia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Avaliação de Resultados em Cuidados de Saúde , Hemorragia Pós-Operatória/prevenção & controle , Estudos Retrospectivos , Tromboelastografia/métodos
2.
Front Immunol ; 14: 1266659, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38035104

RESUMO

SARS-CoV-2 infection is the cause of the disease named COVID-19, a major public health challenge worldwide. Differences in the severity, complications and outcomes of the COVID-19 are intriguing and, patients with similar baseline clinical conditions may have very different evolution. Myeloid-derived suppressor cells (MDSCs) have been previously found to be recruited by the SARS-CoV-2 infection and may be a marker of clinical evolution in these patients. We have studied 90 consecutive patients admitted in the hospital before the vaccination program started in the general population, to measure MDSCs and lymphocyte subpopulations at admission and one week after to assess the possible association with unfavorable outcomes (dead or Intensive Care Unit admission). We analyzed MDSCs and lymphocyte subpopulations by flow cytometry. In the 72 patients discharged from the hospital, there were significant decreases in the monocytic and total MDSC populations measured in peripheral blood after one week but, most importantly, the number of MDSCs (total and both monocytic and granulocytic subsets) were much higher in the 18 patients with unfavorable outcome. In conclusion, the number of circulating MDSCs may be a good marker of evolution in the follow-up of unvaccinated patients admitted in the hospital with the diagnosis of COVID-19.


Assuntos
COVID-19 , Células Supressoras Mieloides , Humanos , Seguimentos , SARS-CoV-2 , Biomarcadores , Hospitalização
3.
Pract Lab Med ; 36: e00320, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37649545

RESUMO

The definition of Insulin autoimmune syndrome includes the presence of high levels of blood insulin and insulin autoantibodies. We encountered a 45-years-old white man with a high insulin serum value that do not fit with the C-peptide result. To discard or to confirm an analytical interference and diagnose a possible Insulin Autoimmune Syndrome we performed the following investigations: dilution linearity test, heterophilic antibody blocking, polyethylene glycol precipitation, measurements with alternative assays, and gel filtration chromatography by size exclusion. The latter technique confirmed that most of the insulin was complexed with a 150-kDa protein, corresponding to immunoglobulin G, identified as insulin autoantibodies. These antibodies were responsible for hypoglycemia attacks in the patient, who had a previous autoimmune disease. This case highlights the importance of carefully analyzing the results and ruling out possible interferences, as well as considering all kinds of pathologies, even if they are infrequent.

5.
Clin Chem Lab Med ; 49(4): 653-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21323623

RESUMO

BACKGROUND: Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS: Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS: The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS: Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.


Assuntos
Análise Química do Sangue/métodos , Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito , Viés , Análise Química do Sangue/instrumentação , Análise Química do Sangue/normas , Cromatografia Líquida de Alta Pressão , Cromatografia por Troca Iônica , Humanos , Laboratórios/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Valores de Referência , Reprodutibilidade dos Testes
6.
Clin Chim Acta ; 523: 144-151, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34537218

RESUMO

BACKGROUND: Overcrowding of the Emergency Department is rapidly becoming a global challenge and a major source of concern for emergency physicians. The desire to improve Emergency Department throughput requires novel approaches to patient flow. MATERIALS AND METHODS: We conducted a prospective and cluster-randomized study, to evaluate the impact in patient outcomes of a new patient flow based on Point-of-Care Testing (POCT). A total of 380 Emergency Severity Level-3 patients were enrolled and studied in two different groups, interventional arm (laboratory analyses performed on POCT analyzers implemented in the Emergency Department) or control arm (central laboratory). The primary outcome was the Emergency Department length of stay. Secondary outcome included the time to first medical intervention, the laboratory turnaround time and the time to disposition decision. Readmission within the 7 days after discharge was also calculated. RESULTS: Length of stay significantly decreased by 88.50 min (from 247.00 to 158.50), time to disposition decision by 89.00 min (from 192.00 to 103.00) and laboratory turnaround time by 67.11 min (from 89.84 to 22.73) in the POCT group. No increase in readmission was found. CONCLUSION: Our strategy based on POCT represents a good approach to optimize patient flow in the Emergency Department and it should be seen as a starting point for further studies focusing on improving throughput.


Assuntos
Serviço Hospitalar de Emergência , Testes Imediatos , Humanos , Tempo de Internação , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos
7.
Eur J Intern Med ; 88: 104-113, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33906810

RESUMO

INTRODUCTION: The midregional fragment of proadrenomedullin (MR-proADM) is known to provide accurate short-, mid- and long term prognostic information in the triage and multi-dimensional risk assessment of patients in the emergency department (ED). In two independent observational cohorts MR-proADM values identified low disease severity patients without risk of disease progression in the ED with no 28 days mortality that wouldn´t require hospitalization. In this interventional study we want to show that the combination of an MR-proADM algorithm with clinical assessment is able to identify low risk patients not requiring hospitalization to safely reduce the number of hospital admissions. METHODS: A randomized-controlled interventional multicenter study in 4 EDs in Spain. The study protocol was approved by Ethics Committees. Control arm patients received Standard Care. MR-proADM guided arm patients with low MR-proADM value (≤0.87 nmol/L) were treated as out-patients, with high MR-proADM value (>0.87 nmol/L) were hospitalized. The hospitalization rate was compared between the study arms. RESULTS: Two hundred patients with suspicion of infection were enrolled. In the MR-proADM guided arm the hospital admission rate in the intention-to-treat (ITT) population was 17% lower than in the control arm (40.6% vs. 57.6%, p=0.024) and 20% lower in the per protocol (PP) population (37.2% vs. 57.6%, p=0.009). No deaths of out-patients and no significant difference for the safety endpoints readmission and representation rates were observed. The readmission rate was only slightly higher in the MR-proADM guided arm compared to the control arm (PP population: at 14 days 9.3% vs. 7.1%, difference 2.1% (95% CI: -11.0% to 15.2%); and at 28 days 11.1% vs. 9.5%, difference 1.6% (95% CI: -12.2% to 15.4%)). The rate of 28 days representation was slightly lower in the MR-proADM guided arm compared to the control arm (20.4% vs. 26.2%, difference -5.8% (95% CI: -25.0% to 13.4%); PP population). CONCLUSIONS: Implementing a MR-proADM algorithm optimizes ED workflows efficiently and sustainably. Hospitals can highly benefit from a reduced rate of hospitalizations by 20% using MR-proADM. The safety in the MR-proADM guided study arm was similar to the Standard Care arm. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT03770533.


Assuntos
Serviço Hospitalar de Emergência , Hospitalização , Adrenomedulina , Biomarcadores , Humanos , Projetos Piloto , Prognóstico , Precursores de Proteínas , Espanha
8.
Clin Biochem ; 50(12): 714-718, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28188739

RESUMO

OBJECTIVES: In this study we aim to compare UX2000 (Sysmex Corp, Japan) and SediMAX/AutionMax (Arkray Factory Inc., Japan), totally automatized analyzers, against Fuchs-Rosenthal counting chamber, the gold standard technique for sediment analysis. DESIGN AND METHODS: Urine samples of 1454 patients from three Spanish hospitals were assessed for red and white blood cells (RBC; WBC) using three different techniques: flow cytometry, image-based method and Fuchs-Rosenthal counting chamber. Test strip results were subjected to concordance evaluation. Agreement was assessed by Cohen's weighted kappa for multinomial results. Sensitivity (SE) and specificity (SP) were calculated. RESULTS: The categorization of the results showed that UX-2000 had higher concordance over SediMAX for WBC (0.819 vs. 0.546) and similar for RBC (0.573 vs. 0.630). For RBC, UX-2000 had higher SE (92.7% vs. 80.3%) but lower SP (77.1% vs. 87.4%), and showed higher both SE (94.3% vs. 76.7%) and SP (94.7% vs. 88.2%) for WBC. Inter-devices test strip agreement was substantial (kappa>0.600) for all variables except for bilirubin (kappa: 0.598). Intra-device test strip agreement was similar for UX2000 and SediMAX with regard to RBC (kappa: 0.553 vs. 0.482) but better for UX2000 with regard to WBC (0.688 vs. 0.465). CONCLUSIONS: Both analyzers studied are acceptable for daily routine lab work, even though SediMAX is easier to use in laboratories thanks to its lower maintenance procedure. UX-2000 has shown to have better concordance with the gold standard method. However, it needs some improvements such as an image module in order to decrease manual microscopy review for urine samples.


Assuntos
Automação Laboratorial/normas , Contagem de Eritrócitos/normas , Contagem de Leucócitos/normas , Urinálise/instrumentação , Adulto , Idoso , Serviço Hospitalar de Emergência , Contagem de Eritrócitos/instrumentação , Eritrócitos/patologia , Feminino , Humanos , Pacientes Internados , Contagem de Leucócitos/instrumentação , Leucócitos/patologia , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Estudos Prospectivos , Espanha , Urinálise/métodos
9.
Clin Biochem ; 48(10-11): 686-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25835152

RESUMO

OBJECTIVES: A better glycemic monitoring of diabetic patients and avoiding complications of poorly controlled diabetes could be possible with point-of-care testing technology (POCT) for HbA1c determination. B-Analyst® was studied to check whether it complied with the quality requirements for this purpose. DESIGN AND METHODS: We evaluated the B-Analyst® (Menarini Diagnostics), which is based in the principle of latex agglutination immunoturbidimetry, to assess the validity of the technique of HbA1c. We carried out the method comparison with the HA-8180® (Menarini Diagnostics) as a reference method [High Performance Liquid Chromatography (HPLC)]. We assessed the analytical quality of the B-Analyst® studying the accuracy: inter-assay variability and intra-assay study. Furthermore, possible interferences by hemoglobinopathies were studied. RESULTS: Regression analysis of the data for the method comparison between HA-8180® and B-Analyst® showed a slope of 1.0085 and an intercept of 0.1208. The Pearson's correlation coefficient was 0.9958 (p<0.0001). Bias study showed a mean difference from B-Analyst® with respect to HA-8180® of 0.1872 with a 95% confidence interval. The standard error of the estimate (Syx) was 0.2091. The concordance correlation coefficient to assess accuracy was 0.9922 (0.9891-0.9945). The CV for the inter-assay study was 1.4%. For the intra-assay study we analyzed 3 samples with different HbA1c % whose CV were 1.03% [4.7% HbA1c (28 mmol/mol)], 0.46% [6.4% HbA1c (46 mmol/mol)] and 0.78% [8.1% HbA1c (65 mmol/mol)]. CONCLUSION: The B-Analyst® evaluated not only showed good correlation with HA-8180®, but also it presented a great accuracy both in the inter-assay and in the intra-assay studies. The B-Analyst® complies with quality specifications required for monitoring of diabetic patients.


Assuntos
Hemoglobinas Glicadas/análise , Sistemas Automatizados de Assistência Junto ao Leito/normas , Cromatografia Líquida de Alta Pressão/normas , Diabetes Mellitus/sangue , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA