Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Eur Heart J ; 45(8): 613-625, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38036414

RESUMO

BACKGROUND AND AIMS: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. METHODS: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. RESULTS: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1-3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). CONCLUSIONS: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros
2.
Crit Care Med ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856631

RESUMO

OBJECTIVES: Most post-cardiotomy (PC) extracorporeal membrane oxygenation (ECMO) runs last less than 7 days. Studies on the outcomes of longer runs have provided conflicting results. This study investigates patient characteristics and short- and long-term outcomes in relation to PC ECMO duration, with a focus on prolonged (> 7 d) ECMO. DESIGN: Retrospective observational cohort study. SETTING: Thirty-four centers from 16 countries between January 2000 and December 2020. PATIENTS: Adults requiring post PC ECMO between 2000 and 2020. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Characteristics, in-hospital, and post-discharge outcomes were compared among patients categorized by ECMO duration. Survivors and nonsurvivors were compared in the subgroup of patients with ECMO duration greater than 7 days. The primary outcome was in-hospital mortality. Two thousand twenty-one patients were included who required PC ECMO for 0-3 days (n = 649 [32.1%]), 4-7 days (n = 776 [38.3%]), 8-10 days (n = 263 [13.0%]), and greater than 10 days (n = 333 [16.5%]). There were no major differences in the investigated preoperative and procedural characteristics among ECMO duration groups. However, the longer ECMO duration category was associated with multiple complications including bleeding, acute kidney injury, arrhythmias, and sepsis. Hospital mortality followed a U-shape curve, with lowest mortality in patients with ECMO duration of 4-7 days (n = 394, 50.8%) and highest in patients with greater than 10 days ECMO support (n = 242, 72.7%). There was no significant difference in post-discharge survival between ECMO duration groups. In patients with ECMO duration greater than 7 days, age, comorbidities, valvular diseases, and complex procedures were associated with nonsurvival. CONCLUSIONS: Nearly 30% of PC ECMO patients were supported for greater than 7 days. In-hospital mortality increased after 7 days of support, especially in patients undergoing valvular and complex surgery, or who had complications, although the long-term post-discharge prognosis was comparable to PC ECMO patients with shorter support duration.

3.
Artif Organs ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803239

RESUMO

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

4.
J Artif Organs ; 26(2): 156-159, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35951178

RESUMO

The optimal surgical approach in patients with pectus excavatum (PEx) who need cardiac surgery remains uncertain. The challenge is even greater, if it is already foreseeable that the patient will be needed further procedure in the next future. We describe a novel sternotomy-sparing approach for minimal-invasive biventricular assist device (BiVAD) implantation in a patient with an acute heart failure (HF) due to dilated cardiomyopathy and severe PEx. Moreover, alternative approaches for ventricular assist device (VAD) implantation and timing of the repair of PEx will be discussed.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tórax em Funil , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Tórax em Funil/complicações , Tórax em Funil/cirurgia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Esternotomia/métodos , Estudos Retrospectivos , Resultado do Tratamento
5.
Int J Mol Sci ; 24(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36982712

RESUMO

Non-surgical bleeding (NSB) remains the most critical complication in patients under left ventricular assist device (LVAD) support. It is well known that blood exposed to high shear stress results in platelet dysfunction. Compared to patients without NSB, decreased surface expression of platelet receptor GPIbα was observed in LVAD patients with NSB. In this study, we aimed to compare the expression level of glycoprotein (GP)Ib-IX-V platelet receptor complex in HeartMate 3 (HM 3) patients with and without bleeding complications to investigate the alterations of the platelet transcriptomic profile on platelet damage and increased bleeding risk. Blood samples were obtained from HM 3 patients with NSB (bleeder group, n = 27) and without NSB (non-bleeder group, n = 55). The bleeder group was further divided into patients with early NSB (bleeder ≤ 3 mo, n = 19) and patients with late NSB (bleeder > 3 mo, n = 8). The mRNA and protein expression of GPIbα, GPIX and GPV were quantified for each patient. Non-bleeder, bleeder ≤ 3 mo and bleeder > 3 mo were comparable regarding the mRNA expression of GPIbα, GPIX and GPV (p > 0.05). The protein analysis revealed a significantly reduced expression level of the main receptor subunit GPIbα in bleeders ≤ 3 mo (p = 0.04). We suggest that the observed reduction of platelet receptor GPIbα protein expression in patients who experienced their first bleeding event within 3 months after LVAD implantation may influence platelet physiology. The alterations of functional GPIbα potentially reduce the platelet adhesion capacities, which may lead to an impaired hemostatic process and the elevated propensity of bleeding in HM 3 patients.


Assuntos
Plaquetas , Complexo Glicoproteico GPIb-IX de Plaquetas , Humanos , Plaquetas/metabolismo , Membrana Celular/metabolismo , Complexo Glicoproteico GPIb-IX de Plaquetas/genética , Complexo Glicoproteico GPIb-IX de Plaquetas/metabolismo , Hemorragia/genética , Adesividade Plaquetária , RNA Mensageiro/metabolismo
6.
Thorac Cardiovasc Surg ; 70(6): 458-466, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35817063

RESUMO

OBJECTIVES: Cardiac support systems are being used increasingly more due to the growing prevalence of heart failure and cardiogenic shock. Reducing cardiac afterload, intracardiac pressure, and flow support are important factors. Extracorporeal membrane oxygenation (ECMO) and intracardiac microaxial pump systems (Impella) as non-permanent MCS (mechanical circulatory support) are being used increasingly. METHODS: We reviewed the recent literature and developed an international European registry for non-permanent MCS. RESULTS: Life-threatening conditions that are observed preoperatively often include reduced left ventricular function, systemic hypoperfusion, myocardial infarction, acute and chronic heart failure, myocarditis, and valve vitia. Postoperative complications that are commonly observed include severe systemic inflammatory response, ischemia-reperfusion injury, trauma-related disorders, which ultimately may lead to low cardiac output (CO) syndrome and organ dysfunctions, which necessitates a prolonged ICU stay. Choosing the appropriate device for support is critical. The management strategies and complications differ by system. The "heart-team" approach is inevitably needed.However despite previous efforts to elucidate these topics, it remains largely unclear which patients benefit from certain systems, when is the right time to initiate (MCS), which support system is appropriate, what is the optimal level and type of support, which therapeutic additive and supportive strategies should be considered and ultimately, what are the future prospects and therapeutic developments. CONCLUSION: The European cardiac surgical register ImCarS has been established as an IIT with the overall aim to evaluate data received from the daily clinical practice in cardiac surgery. Interested colleagues are cordially invited to join the register. CLINICAL REGISTRATION NUMBER: DRKS00024560. POSITIVE ETHICS VOTE: AZ 246/20 Faculty of Medicine, Justus-Liebig-University-Gießen.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
7.
Int J Mol Sci ; 23(18)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36142161

RESUMO

Non-surgical bleeding (NSB) is one of the major clinical complications in patients under continuous-flow left ventricular assist device (LVAD) support. The increased shear stress leads to an altered platelet receptor composition. Whether these changes increase the risk for NSB is unclear. Thus, we compared the platelet receptor composition of patients with (bleeder group, n = 18) and without NSB (non-bleeder group, n = 18) prior to LVAD implantation. Blood samples were obtained prior to LVAD implantation and after bleeding complications in the post-implant period. Platelet receptor expression of GPIbα, GPIIb/IIIa, P-selectin and CD63 as well as intra-platelet oxidative stress levels were quantified by flow cytometry. Bleeders and non-bleeders were comparable regarding clinical characteristics, von Willebrand factor diagnostics and the aggregation capacity before and after LVAD implantation (p > 0.05). LVAD patients in the bleeder group suffered from gastrointestinal bleeding (33%; n = 6), epistaxis (22%; n = 4), hematuria or hematoma (17%; n = 3, respectively) and cerebral bleeding (11%; n = 2). Prior to LVAD implantation, a restricted surface expression of the platelet receptors P-selectin and GPIIb/IIIa was observed in the bleeder group (P-selectin: 7.2 ± 2.6%; GPIIb/IIIa: 26,900 ± 13,608 U) compared to non-bleeders (P-selectin: 12.4 ± 8.1%, p = 0.02; GPIIb/IIIa: 36,259 ± 9914 U; p = 0.02). We hypothesized that the reduced platelet receptor expression of P-selectin and GPIIb/IIIa prior to LVAD implantation may be linked to LVAD-related NSB.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Plaquetas/metabolismo , Insuficiência Cardíaca/metabolismo , Coração Auxiliar/efeitos adversos , Hemorragia , Humanos , Selectina-P/metabolismo , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Fator de von Willebrand/metabolismo
8.
J Cardiovasc Electrophysiol ; 32(2): 515-522, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33270307

RESUMO

OBJECTIVES: This study sought to validate the performance of the VT-LVAD risk model in predicting late ventricular arrhythmias (VAs) in patients after left ventricular assist device (LVAD) implantation. BACKGROUND: The need for implantable cardioverter-defibrillator (ICD)-implantation in LVAD recipients is not well studied. A better selection of the patients with high risk for late VAs could lead to a more targeted ICD-implantation or replacement. METHODS: The study evaluated the performance of the VT-LVAD prognostic score (VAs prior LVAD, no ACE-inhibitor in medication, heart failure duration > 12 months, early VAs post-LVAD implantation, atrial fibrillation prior LVAD, idiopathic dilated cardiomyopathy) for the endpoint of the occurrence of late VAs in 357 LVAD patients in Heart Centre of Leipzig. RESULTS: From the initial 460 patients, 357 (age: 58 ± 10 years; left ventricular ejection fraction: 20 ± 6%; HeartWare: 50%; HeartMate III: 42%) were assigned to four risk groups according to their VT-LVAD score varying from low risk to very high risk. After 25 months, late VAs occurred in 130 patients. The VT-LVAD score was an independent predictor of late VAs (multivariate analysis; p = < .001; goodness-of-tip p = .347; odds ratio: 4.8). While there was no statistically significant difference between the low- and intermediate-risk group, risk stratification for patients with high risk and very high risk performed more accurately (pairwise comparison p = .005 and p < .001, respectively). CONCLUSIONS: The VT-LVAD score predicted accurately the occurrence of late VAs in high-risk LVAD recipients in a large external cohort of LVAD recipients supporting its utility for more targeted ICD implantations.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Ventricular , Idoso , Arritmias Cardíacas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Thorac Cardiovasc Surg ; 69(3): 263-270, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32035427

RESUMO

BACKGROUND: Primary graft dysfunction (PGD) is a common cause of early death after heart transplantation (htx). The use of extracorporeal life support (ECLS) after htx has increased during the last years. It is still discussed controversially whether peripheral cannulation is favorable compared to central cannulation. We aimed to compare both cannulation techniques. METHODS: Ninety patients underwent htx in our department between 2010 and 2017. Twenty-five patients were treated with ECLS due to PGD (10 central extracorporeal membrane oxygenator [cECMO] and 15 peripheral extracorporeal membrane oxygenator [pECMO] cannulation). Pre- and intraoperative parameters were comparable between both groups. RESULTS: Thirty-day mortality was comparable between the ECLS-groups (cECMO: 30%; pECMO: 40%, p = 0.691). Survival at 1 year (n = 18) was 40 and 30.8% for cECMO and pECMO, respectively. The incidence of postoperative renal failure, stroke, limb ischemia, and infection was comparable between both groups. We also did not find significant differences in duration of mechanical ventilation, intensive care unit stay, or in-hospital stay. The incidence of bleeding complications was also similar (cECMO: 60%; pECMO: 67%). Potential differences in support duration in pECMO group (10.4 ± 9.3 vs. 5.7 ± 4.7 days, p = 0.110) did not reach statistical significance. CONCLUSIONS: In patients supported for PGD, peripheral and central cannulation strategies are safe and feasible for prolonged venoarterial ECMO support. There was no increase in bleeding after central implantation. With regard to the potential complications of a pECMO, we think that aortic cannulation with tunneling of the cannula and closure of the chest could be a good option in patients with PGD after htx.


Assuntos
Cateterismo , Oxigenação por Membrana Extracorpórea , Transplante de Coração , Disfunção Primária do Enxerto/terapia , Adulto , Idoso , Cateterismo/efeitos adversos , Cateterismo/mortalidade , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Transplante de Coração/efeitos adversos , Transplante de Coração/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Primária do Enxerto/diagnóstico , Disfunção Primária do Enxerto/mortalidade , Disfunção Primária do Enxerto/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
J Cardiothorac Vasc Anesth ; 35(9): 2669-2680, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33262035

RESUMO

OBJECTIVE: To investigate the frequency, predictors, and outcomes of neurologic injury in adults treated with postcardiotomy extracorporeal membrane oxygenation (PC-ECMO). DESIGN: A retrospective multicenter registry study. SETTING: Twenty-one European institutions where cardiac surgery is performed. PARTICIPANTS: A total of 781 adult patients who required PC-ECMO during 2010 to 2018 were divided into patients with neurologic injury (NI) and patients without neurologic injury (NNI). MEASUREMENTS AND MAIN RESULTS: Baseline and operative data, in-hospital outcomes, and long-term survival were compared between the NI and the NNI groups. Predictors of neurologic injury were identified. A subgroup analysis according to the type of neurologic injury was performed. Overall, NI occurred in 19% of patients in the overall series, but the proportion of patients with NI ranged from 0% to 65% among the centers. Ischemic stroke occurred in 84 patients and hemorrhagic stroke in 47 patients. Emergency procedure was the sole independent predictor of NI. In-hospital mortality was higher in the NI group than in the NNI group (79% v 61%, p < 0.001). The one-year survival was lower in the NI group (17%) compared with the NNI group (37%). Long-term survival did not differ between patients with ischemic stroke and those with hemorrhagic stroke. CONCLUSION: Neurologic injury during PC-ECMO is common and associated with a dismal prognosis. There is considerable interinstitutional variation in the proportion of neurologic injury in PC-ECMO-treated adults. Well-known risk factors for stroke are not associated with neurologic injury in this setting.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mortalidade Hospitalar , Humanos , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/etiologia , Acidente Vascular Cerebral
11.
J Card Surg ; 36(4): 1344-1351, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33547707

RESUMO

BACKGROUND: The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. METHODS: A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. RESULTS: The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. CONCLUSION: LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Humanos , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
12.
Eur Heart J ; 41(39): 3801-3809, 2020 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-33107561

RESUMO

AIMS: The ELEVATE Registry was designed to study long-term outcomes with the Heartmate 3 (HM3), a fully magnetically levitated centrifugal ventricular assist device, in a real-world population following CE-mark approval. METHODS AND RESULTS: A total of 540 patients, implanted in Europe and the Middle East were followed in ELEVATE. The registry included 463 patients receiving the HM3 as primary implant (Primary Implant Cohort), 19 patients underwent a pump upgrade from another device (Pump Exchange Cohort) and 58 patients who had experienced an outcome before having the possibility to sign the Informed Consent, for which only outcome data were collected (Anonymized Cohort). Data collection included demographics, survival, adverse events, EQ-5D Visual Analog Score quality of life (EQ-5D VAS QOL) questionnaire, and 6-min walk distance (6MWD). Mean age was 55.6 ± 11.7 years (89% male, 48% ischaemic cardiomyopathy). Seventy per cent of patients were in INTERMACS Profile 1-3 and 12.7% were on temporary mechanical circulatory support. Primary Implant Cohort survival was 83% after 2 years. In the Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Primary Implant Cohort, strokes were observed in 10.2%, gastrointestinal bleedings in 9.7%, pump thrombosis in 1.5%, and outflow graft twists in 3.5%. Heartmate 3 implantation resulted in a significant and sustained improvement of functional capacity and QOL. CONCLUSION: In a real-world population, cohort implanted with the HM3 left ventricular assist device we demonstrate good long-term survival, sustained improvement of functional capacity, and low rates of adverse events (including pump thrombosis). CLINICALTRIALS.GOV IDENTIFIER: NCT02497950.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Idoso , Europa (Continente) , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Oriente Médio , Estudos Prospectivos , Qualidade de Vida , Sistema de Registros , Resultado do Tratamento
13.
J Card Fail ; 26(7): 580-587, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32417377

RESUMO

BACKGROUND: In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. METHODS AND RESULTS: Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 ± 10 vs 52 ± 12 years; P < .001), more often New York Heart Association functional class IV (63% vs 42%; P = .03), and more often had type 2 diabetes (43% vs 17%; P < .001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P < .002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking <300 m (both P < .01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). CONCLUSIONS: Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Sistema de Registros , Resultado do Tratamento
14.
Artif Organs ; 44(9): 947-954, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32645761

RESUMO

Establishing a chronic heart failure (HF) model is challenging, particularly in the ovine model. The aim of this study was to establish a reproducible model of HF in an ovine model. Seventeen sheep were operated using the left thoracotomy approach. Chronic HF was induced through ligation of the diagonal and marginal branches only. Perioperative hemodynamic and echocardiographic parameters were compared. A total of (3 ± 1) coronary ligations were used. Thirteen animals survived the procedure and were followed up for (15 ± 5) days. The mean arterial pressure, heart rate (HR), mean pulmonary artery pressure (mPAP), central venous pressure, and cardiac output at baseline and prior to animal sacrifice was (75 ± 14 mmHg) and (68 ± 16 mmHg) P = .261; (72 ± 9 bpm), (100 ± 28 bpm) P = .01; (15 ± 4 mmHg) and (18 ± 5 mmHg) P = .034; (10 ± 6 mmHg) and (8 ± 4 mmHg) P = .326; (3.4 ± 1 L/min) and (3.9 ± 1 L/min) P = .286, respectively. The LVEF at baseline and prior to animal sacrifice was (63 ± 13%) and (43 ± 6%) P = .012. Twelve surviving animals were supported with LVAD in a follow-up procedure. Chronic stable HF in sheep was successively established. Clinical symptoms and drastic increase in the mPAP and HR as well as echo findings were the most sensitive parameters of HF. This reproducible ovine model has proven to be highly promising for research regarding HF.


Assuntos
Modelos Animais de Doenças , Insuficiência Cardíaca/etiologia , Hemodinâmica/fisiologia , Animais , Vasos Coronários/cirurgia , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Humanos , Ligadura , Ovinos
15.
J Cardiothorac Vasc Anesth ; 34(10): 2655-2663, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32546407

RESUMO

OBJECTIVES: Patient blood management (PBM) is increasingly introduced into clinical practice. Minimizing effects on transfusion have been proven, but relevance for clinical outcome has been sparsely examined. In regard to this, the authors analyzed the impact of introducing intraoperative PBM to cardiac surgery. DESIGN: Retrospective case-control study. SETTING: Single center. PARTICIPANTS: A total of 3,170 patients who underwent either coronary artery bypass grafting, isolated aortic valve replacement, or a combined procedure at the authors' institution between January 1, 2007, and December 31, 2015. INTERVENTION: In 2013, an intraoperative PBM service was established offering therapy recommendations on the basis of real-time laboratory monitoring. Comparisons to conventional coagulation management were adjusted for optimization of general, surgical, and perioperative care standards by interrupted time-series analysis and risk-dependent confounding by propensity- score matching. MEASUREMENTS AND MAIN RESULTS: Primary study endpoints were in-hospital mortality and morbidity. Morbidity was defined as clinically relevant prolongation of hospital stay, which was related to accumulation of postoperative complications. Transfusion requirements, bleeding, and thromboembolic complications were not treated as primary endpoints, but were also explored. The recommendations on the basis of real-time laboratory monitoring were adopted by the operative team in 72% of patients. Intraoperative PBM was associated independently with a reduction of morbidity (8.3% v 6.3%, p = 0.034), whereas in-hospitalmortality (3.0% v 2.6%, p = 0.521) remained unaffected. The need for red blood cell transfusion decreased (71.1% v 65.0%, p < 0.001), as did bleeding complications requiring surgical re-exploration (3.5% v 1.8%, p = 0.004). At the same time, stroke increased by statistical trend (1.0% v 1.9%, p = 0.038; after correction for imbalanced type of surgical procedure p = 0.085). CONCLUSIONS: Real-time laboratory recommendations achieved a high acceptance rate early after initiation. Improvement of clinical outcome by intraoperative PBM adds to the optimized surgical care. However, the corridor between hemostatic optimization and thromboembolic risk may be narrow.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Transfusão de Sangue , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Casos e Controles , Ponte de Artéria Coronária , Humanos , Estudos Retrospectivos
16.
Catheter Cardiovasc Interv ; 93(4): 699-706, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30328258

RESUMO

OBJECTIVES: The objective of this study was to assess the prognostic value of the Model for End-stage Liver Disease (MELD)-XI score in patients undergoing PMVR with the MitraClip system. BACKGROUND: MELD-XI score, which was originally developed for prognostic assessment in patients with advanced liver disease, has been reported as a predictor of outcome in heart failure patients. METHODS: A total of 192 consecutive patients undergoing percutaneous mitral valve repair (PMVR) were included into final analysis. MELD-XI score was calculated on the day of the procedure and patients were categorized into three groups based on MELD-XI score and compared with regards to clinical characteristics and outcomes following PMVR. RESULTS: MELD-XI > 12 was associated with male gender, higher logistic EuroSCORE, reduced left ventricular ejection fraction, enlarged right ventricular end-diastolic diameter, degree of mitral regurgitation, increased NT-proBNP serum levels and elevated right atrial pressures. Youden-Index revealed a cutoff of 16 in the MELD-XI score as best predictor of one-year all-cause mortality. Kaplan-Meier analysis and the log-rank test confirmed increased one-year mortality in patients with critically high score above 16 (mortality MELD-XI score > 16 vs 16-12 vs <12:39% vs 9%. vs 15%; P = 0.005). Compared to patients with lower MELD-XI score, these patients exhibited a more than 3-fold increased one-year mortality after PMVR. CONCLUSION: Given the high mortality in patients with a MELD-XI score > 16, these patients require a high-risk preoperative assessment and should undergo a careful discussion within the heart team for the best treatment option given the considerable one-year mortality following PMVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Nefropatias/diagnóstico , Testes de Função Renal , Rim/fisiopatologia , Hepatopatias/diagnóstico , Testes de Função Hepática , Fígado/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Nefropatias/mortalidade , Nefropatias/fisiopatologia , Hepatopatias/mortalidade , Hepatopatias/fisiopatologia , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Eur Heart J ; 39(37): 3454-3460, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30165521

RESUMO

Aims: The ELEVATE registry was planned to study post-approval outcomes with HeartMate 3™ (HM3), a fully magnetically levitated continuous flow left ventricular assist device (LVAD). Methods and results: A total of 482 patients provided consent to participate in ELEVATE (enrolled cohort). Data collection included baseline demographics, survival, adverse events, quality of life (QOL) [EuroQoL-5 Dimensions visual analogue scale (VAS), and 6-minute walk distance (6MWD)]. An additional 58 patients were implanted with HM3 during the same period but expired or were explanted prior to consent, and only survival data were collected (anonymized cohort). We report the 6-month outcomes of the patients who received HM3 as their primary implant (n = 463) and the survival of the 540 patients in the full cohort (enrolled + anonymized). Baseline characteristics included a mean age of 55.6 ± 11.7 years, 89% male, 48% ischaemic aetiology, and 70% on inotropes. The majority of patients (66%) were bridge-to-transplantation (BTT) and 32% were INTERMACS profile 1-2. Full cohort survival at 6 months was 82 ± 2%. In the enrolled primary implant patients, there was no incidence of pump thrombosis, major bleeding was 25%, major infection 35%, and any stroke type 5%. Functional capacity improved significantly (Δ6MWD 230 ± 191 m) as did QOL (ΔVAS 31 ± 23). Freedom from unplanned rehospitalizations at 6 months was 68 ± 2%. Conclusion: The 6-month outcomes of the HM3 LVAD demonstrate a highly reliable, thrombosis free, device with low incidence of stroke and improved functional capacity, and QOL. ClinicalTrials. gov Identifier: NCT02497950.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
19.
J Card Surg ; 31(8): 559-61, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27349495

RESUMO

We report on the unique clinical course of a 44-year-old male HIV-positive heart transplant recipient, who was bridged by mechanical circulatory support (MCS). The patient was admitted with acute ischemic heart failure due to severe myocardial infarction. After emergency coronary artery bypass grafting and nine days of extracorporeal life support, we implanted a left ventricular assist device. As HIV infection was effectively treated and other contraindications were not present, we decided to perform a heart transplantation (HTX). At the current time, 34 months after unremarkable HTX, rejection or opportunistic infections have not occurred.


Assuntos
Infecções por HIV/complicações , Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar , Adulto , Insuficiência Cardíaca/complicações , Humanos , Masculino , Fatores de Tempo
20.
Artif Organs ; 39(8): 719-23, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25912873

RESUMO

Central veno-arterial extracorporeal membrane oxygenation (ECMO) is traditionally implanted using direct cannulation of the aorta and right atrium. We aim to summarize the outcome of patients who underwent perioperative central ECMO implantation using an alternative surgical approach, which allows sternum closure and does not require resternotomy at the time of explantation. We retrospectively reviewed patients who required veno-arterial ECMO support at our institution between January 2013 and July 2014. Inclusion criteria were patients undergoing central ECMO implantation using the above-mentioned implantation technique. Nine patients (65 ± 14 years) were supported using this technique. Four patients underwent coronary bypass surgery as a primary surgery and the other five patients had combined coronary and valve surgeries. The average duration of ECMO support was 9 ± 7 days (range 1-24 days). The dominant postoperative complication was renal failure, which occurred in eight patients (89%). In four patients (44%), the ECMO was successfully removed. Survival rate to discharge was 22%. In conclusion, this study showed the feasibility of this alternative ECMO implantation technique. No technical issues were encountered. Extended support duration and reducing resternotomy risks may be the main advantages of this technique compared with conventional ECMO implantation methods.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Oxigenação por Membrana Extracorpórea/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Oxigenadores de Membrana , Choque Cardiogênico/terapia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/mortalidade , Remoção de Dispositivo , Desenho de Equipamento , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Estudos de Viabilidade , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Oxigenadores de Membrana/efeitos adversos , Alta do Paciente , Assistência Perioperatória , Recuperação de Função Fisiológica , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA