Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Surg Technol Int ; 35: 113-119, 2019 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-31687787

RESUMO

INTRODUCTION: Robotic-assisted surgery continues to evolve. Technical advantages are reported for intracorporal suturing, a technique with a long learning curve in conventional laparoscopy. The success of laparoscopic fundoplication relies on precise suturing at the hiatus and of the fundal wrap. Therefore, robotic assistance can be a useful tool for this particular procedure. In March 2017, the Senhance® Surgical System (Transenterix, Inc., Morrisville, North Carolina) was introduced into robotic-assisted procedures at the St. Marien-Krankenhaus, Siegen, Germany. MATERIALS AND METHODS: Between March 2017 and July 2019, we performed 36 surgeries of the upper GI tract with the Senhance® Surgical System. Eighteen patients underwent the classic Nissen fundoplication and are the subject of this study. All patients gave informed consent for robotic assistance with prospective data acquisition and analysis. RESULTS: Seven male and 11 female patients were included in the study. The median age of the cohort was 58.5 years (range 30-81 years) and the median body mass index (BMI) was 30.4 kg/m2 (range 22.7-40.1 kg/m2). The median total operative time was 95.5 minutes (range 68-194 minutes) and, despite the small sample size, we observed a significant learning curve throughout the study period (p<0.05). Before the introduction of the Senhance® Ultrasonic energy device, conversion to laparoscopic fundoplication was necessary in two patients. We performed one re-do laparoscopy on the day of surgery due to pain without any significant intraoperative findings and one laparoscopic revision to Toupet fundoplication after seven months due to dysphagia. CONCLUSION: This first report of robotic-assisted Nissen fundoplication with the Senhance® Surgical System demonstrates technical feasibility. After successful introduction of the Senhance® Ultrasonic, our conversion rate to standard laparoscopic surgery was significantly reduced.


Assuntos
Fundoplicatura , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fundoplicatura/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Surg Technol Int ; 34: 243-249, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30716159

RESUMO

INTRODUCTION: This retrospective study was performed to evaluate the safety and feasibility of the new Senhance Robotic System (TransEnterix Inc., Morrisville, North Carolina) for inguinal hernia repairs using the transabdominal preperitoneal approach. MATERIALS AND METHODS: From March to September 2017, 76 inguinal hernia repairs in 64 patients were performed using the Senhance Robotic System. Patients were between 18 and 90 years of age, eligible for a laparoscopic procedure with general anesthesia, had no life-threatening disease with a life expectancy of less than 12 months, and a body mass index (BMI) < 35. A retrospective chart review was performed for a variety of pre-, peri-, and postoperative data including, but not limited to, patient demographics, hernia characteristics, and intraoperative and postoperative complications. RESULTS: Fifty-four male and 10 female patients were included in the study. Median age was 56.5 years (range 22-86 years), and median BMI was 25.9 kg/m2 (range 19.5-31.8 kg/m2). Median docking time was seven minutes (range 2-21 minutes), and median operative time was 48 minutes (range 18-142 minutes). Two cases were converted to standard laparoscopic surgery due to robot malfunction and abdominal wall bleeding, respectively. Median length of stay was one day. CONCLUSION: We report the first series of laparoscopic inguinal hernia repairs using the new Senhance Robotic System. Compared to conventional laparoscopic transabdominal preperitoneal (TAPP) hernia repairs, there was no significant difference in operative time or perioperative complications. Additionally, there was no significant learning curve detected due to its intuitive applicability. Therefore, the Senhance Robotic System promises broad applicability across a range of laparoscopic general surgical operations.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/instrumentação , Herniorrafia/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Telas Cirúrgicas , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA