Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 47(4): 349-56, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24485850

RESUMO

OBJECTIVES: To evaluate the effect of intraoperative guidance by means of live fluoroscopy image fusion with computed tomography angiography (CTA) on iodinated contrast material volume, procedure time, and fluoroscopy time in endovascular thoraco-abdominal aortic repair. METHODS: CTA with fluoroscopy image fusion road-mapping was prospectively evaluated in patients with complex aortic aneurysms who underwent fenestrated and/or branched endovascular repair (FEVAR/BEVAR). Total iodinated contrast material volume, overall procedure time, and fluoroscopy time were compared between the fusion group (n = 31) and case controls (n = 31). Reasons for potential fusion image inaccuracy were analyzed. RESULTS: Fusion imaging was feasible in all patients. Fusion image road-mapping was used for navigation and positioning of the devices and catheter guidance during access to target vessels. Iodinated contrast material volume and procedure time were significantly lower in the fusion group than in case controls (159 mL [95% CI 132-186 mL] vs. 199 mL [95% CI 170-229 mL], p = .037 and 5.2 hours [95% CI 4.5-5.9 hours] vs. 6.3 hours (95% CI 5.4-7.2 hours), p = .022). No significant differences in fluoroscopy time were observed (p = .38). Respiration-related vessel displacement, vessel elongation, and displacement by stiff devices as well as patient movement were identified as reasons for fusion image inaccuracy. CONCLUSION: Image fusion guidance provides added value in complex endovascular interventions. The technology significantly reduces iodinated contrast material dose and procedure time.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Angiografia/instrumentação , Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Meios de Contraste/uso terapêutico , Procedimentos Endovasculares/métodos , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade
2.
Hautarzt ; 61(4): 332-8, 2010 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-19967328

RESUMO

For more than two decades silicone has successfully been employed in the treatment and prevention of hypertrophic scars and keloids as a painless noninvasive modality with few side effects. In the present trial, after 3 months of treatment the Patient Scar Assessment Scale demonstrated that patient satisfaction with the silicone application was significantly higher compared to placebo. When treatment was stopped after 3 months, the topical silicone spray did not exhibit any lasting long-term impact on the objective results of scar formation. Due to the significant differences in patient satisfaction once treatment has ended and since the administration is safe and simple, any final decision on treatment indication should be tailored to the patient and include the psychological well-being of the patient as well as the temporary improvement in scar formation during treatment.


Assuntos
Cicatriz/patologia , Cicatriz/prevenção & controle , Silicones/administração & dosagem , Adolescente , Adulto , Idoso , Cicatriz/tratamento farmacológico , Método Duplo-Cego , Feminino , Gases/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Efeito Placebo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA