Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
J Card Surg ; 33(7): 356-362, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29790206

RESUMO

OBJECTIVES: Bioprostheses with pericardial leaflets mounted externally on the stent pose a high risk for valve-in-valve (ViV) procedures. This study analyzed the efficacy and safety of ViV procedures for treating structural valve deterioration (SVD) in Mitroflow bioprostheses. METHODS: Between January 2012 and August 2017, 11 patients (mean age 80.3 ± 5.6 years) were treated for SVD of Mitroflow bioprostheses with transcatheter ViV procedures (six transapical [TA] and five transfemoral [TF]) using balloon expandable bioprostheses. RESULTS: All patients but one were in NYHA class III-IV. Mean STS PROM, euroSCORE I, and euroSCORE II were 8 ± 6.5%, 27.8 ± 11.5%, and 12 ± 5.9%, respectively. Two patients had a "porcelain aorta." The size of implanted valves were 23 mm in 10 cases and 26 mm in one case. One patient suffered a coronary occlusion during a TF approach. The mean volume of contrast used in TF implants was 163 ± 69.8 mL. No contrast media were used in TA procedures. There was one in-hospital death (10%). At 1 year of follow-up, peak and mean aortic gradients were 25.5 ± 5.8 mmHg and 15.5 ± 5.7 mmHg, respectively. One patient had mild paravalvular regurgitation. Cumulative survival was 90.9% at 1 year, 70.7% at 2 years, and 53% at 3 years. CONCLUSIONS: ViV procedures with balloon-expandable aortic valves provide good hemodynamic and clinical mid-term results for treating patients with a degenerated Mitroflow aortic bioprosthesis. Special care must be taken in small aortic roots, when the stented valve is in the supra-annular position to avoid coronary ostial obstruction.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Segurança , Stents , Resultado do Tratamento
3.
JACC Case Rep ; 26: 102080, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38094169

RESUMO

This article presents a case of aortic root rupture after transfemoral aortic valve replacement, successfully treated by a percutaneous approach, with a good evolution of the patient both during hospitalization and in the long term, being asymptomatic at the cardiovascular level after 18 months of follow-up. (Level of Difficulty: Advanced.).

4.
Am Heart J ; 161(6): 1207-13, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21641370

RESUMO

BACKGROUND: The use of vascular closure devices (VCDs) for the reduction of access site complications following percutaneous coronary intervention (PCI) remains controversial. Patients undergoing primary PCI for acute ST-segment elevation myocardial infarction (STEMI) are at high risk of femoral artery complications. A lack of information exists regarding the use of VCDs in this group of patients because they have been routinely excluded from randomized trials. This study sought to evaluate the safety and efficacy of the routine use of VCDs after primary PCI. METHODS: A total of 558 consecutive patients undergoing primary PCI for STEMI via femoral route were studied for in-hospital outcomes through a prospective registry from January 2003 to December 2008. The primary end point was the presence of major vascular complication (MVC) defined as a composite of fatal access site bleeding, access site complication requiring interventional or surgical correction, or access site bleeding with ≥3 g/dL drop in hemoglobin or requiring blood transfusion. RESULTS: Of the total patients, 464 (83.2%) received a VCD; and manual compression was used in 94 patients (16.8%). Major vascular complication occurred in 5.2% of patients. The risk of MVC was significantly lower with VCDs compared with manual compression (4.3% vs 9.6%, P = .036). Multivariable logistic regression analysis determined that VCD use remained an independent predictor of lower rate of MVC (odds ratio 0.38, 95% CI 0.17-0.91). CONCLUSIONS: The use of VCDs in patients undergoing primary PCI for STEMI is safe and is associated with lower rates of MVC compared with manual compression.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio/terapia , Técnicas de Fechamento de Ferimentos/instrumentação , Idoso , Cateterismo Cardíaco , Feminino , Artéria Femoral/cirurgia , Hemorragia/epidemiologia , Hemorragia/prevenção & controle , Hemostasia Cirúrgica , Humanos , Tempo de Internação , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Inibidores da Agregação Plaquetária/uso terapêutico , Prognóstico , Técnicas de Fechamento de Ferimentos/efeitos adversos
5.
Interact Cardiovasc Thorac Surg ; 33(2): 173-180, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-33782703

RESUMO

OBJECTIVES: This study aims to analyse the risks associated with valve-in-valve procedures for treating structural valve deterioration in Mitroflow bioprostheses, as well as to determine the impact of the original Mitroflow size on the patients' long-term outcomes. METHODS: Between January 2012 and September 2019, 21 patients (61.9% males; mean age 82.4 ± 5.4 years) were treated for Mitroflow deterioration with valve-in-valve procedures (12 transapical and 9 transfemoral). RESULTS: Mean EuroSCORE I and EuroSCORE II were 28.2% ± 13.6% and 10.5% ± 6.1%, respectively. Six patients presented an indexed aortic root diameter <14 mm/m2 and 7 patients a diameter of sinus of Valsalva <30 mm. Implanted transcatheter valve sizes were 20 mm in 6 cases, 23 mm in 14 cases and 26 mm in 1 patient. A Valve Academic Research Consortium-2 complication occurred in 23.8% of cases, including 3 coronary occlusions. In-hospital mortality was 9.5%. The 20 mm transcatheter valves presented significantly higher postoperative peak and mean aortic gradients than other sizes (54.1 ± 11.3 mmHg vs 29.9 ± 9.6 mmHg, P = 0.003; and 29.3 ± 7.7 mmHg vs 17.4 ± 5.9 mmHg, P = 0.015, respectively). There were 12 cases of patient-prosthesis mismatch (57.1%) and 3 cases (14.3%) of severe patient-prosthesis mismatch. Cumulative survival was 85.7% ± 7.6% at 1 year, 74.3% ± 10% at 2 years and 37.1% ± 14.1% at 5 years. CONCLUSIONS: Valve-in-valve procedures with balloon-expandable transcatheter valves associate a high risk of coronary occlusion in patients with indexed aortic root diameter <14 mm/m2 and low coronary ostia <12 mm. Valve-in valve procedures with 20 mm balloon-expandable transcatheter valves in ≤21 mm Mitroflow bioprosthesis leave significant residual transvalvular gradients that might obscure patients' long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Fluoroscopia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1054-1061, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33257214

RESUMO

INTRODUCTION AND OBJECTIVES: Economic studies may help decision making in the management of multivessel disease in the setting of myocardial infarction. We sought to perform an economic evaluation of CROSS-AMI (Complete Revascularization or Stress Echocardiography in Patients With Multivessel Disease and ST-Segment Elevation Acute Myocardial Infarction) randomized clinical trial. METHODS: We performed a cost minimization analysis for the strategies (complete angiographic revascularization [ComR] and selective stress echocardiography-guided revascularization [SelR]) compared in the CROSS-AMI clinical trial (N=306), attributable the initial hospitalization and readmissions during the first year of follow-up, using current rates for health services provided by our health system. RESULTS: The index hospitalization costs were higher in the ComR group than in SelR arm (19 657.9±6236.8 € vs 14 038.7±4958.5 €; P <.001). There were no differences in the costs of the first year of follow-up rehospitalizations between both groups for (ComR 2423.5±4568.0 vs SelR 2653.9±5709.1; P=.697). Total cost was 22 081.3±7505.6 for the ComR arm and 16 692.6±7669.9 for the SelR group (P <.001). CONCLUSIONS: In the CROSS-AMI trial, the initial extra economic costs of the ComR versus SelR were not offset by significant savings during follow-up. SelR seems to be more efficient than ComR in patients with ST-segment elevation acute coronary syndrome and multivessel disease treated by emergent angioplasty. Study registred at ClinicalTrial.gov (Identifier: NCT01179126).


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Análise Custo-Benefício , Ecocardiografia sob Estresse , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Resultado do Tratamento
7.
Open Heart ; 8(2)2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34810276

RESUMO

BACKGROUND: The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) is a validated instrument for assessing quality of life (QoL) in patients with severe aortic stenosis (AS). In this study, we evaluated health status outcomes, based on the TASQ, in patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). METHODS: The TASQ registry was a prospective observational registry. Patients with severe AS from nine centres in Europe and one in Canada underwent either SAVR or transfemoral TAVR. Patients completed the TASQ, Kansas City Cardiomyopathy Questionnaire and Short Form-12 V.2 prior to the intervention, predischarge, and at 30-day and 3-month follow-ups. Primary end point was the TASQ score. RESULTS: In both the TAVR (n=137) and SAVR (n=137) cohorts, significant increases were observed in all three scores. The overall TASQ score improved as did all but one of the individual domains at 3 months after the intervention (p<0.001). TASQ health expectations were the only domain which worsened (p<0.001). Across TASQ subscores, significant changes were evident from the time of discharge in the TAVR and 30-day follow-up in the SAVR cohort. In a categorical analysis of the TASQ, 39.7% of the TAVR group and 35.0% of the SAVR group had a substantially improved health status at 3 months compared with baseline. CONCLUSIONS: The TASQ captured changes in QoL among patients with severe AS who were treated with TAVR or SAVR. QoL improved substantially after either intervention, as indicated by changes in the TASQ overall score at 3 months. TRIAL REGISTRATION NUMBER: NCT03186339.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Nível de Saúde , Qualidade de Vida , Inquéritos e Questionários , Substituição da Valva Aórtica Transcateter/psicologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/psicologia , Canadá/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Morbidade/tendências , Período Pós-Operatório , Estudos Prospectivos
8.
ESC Heart Fail ; 8(1): 270-279, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33207035

RESUMO

AIMS: There is no quality of life tool specifically developed for patients with severe aortic stenosis (AS) to assess how this chronic condition and its treatment affect patients. The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) has been developed to overcome this gap. The results of the validation of the TASQ in patients undergoing treatment for severe AS are presented. METHODS AND RESULTS: Prospective study at 10 centres in Europe and Canada, which enrolled 274 patients with severe symptomatic AS undergoing surgical or transcatheter aortic valve replacement. Mean TASQ score at baseline was 71.2 points and increased to 88.9 three months after aortic valve implantation (P < 0.001). Increases were seen for the emotional impact (32.0 to 39.0; P < 0.001), physical limitations (14.8 to 22.0; P < 0.001), and physical symptoms (8.5 vs. 11.0; P < 0.001) domains. Internal consistency was good/excellent for overall TASQ score (α = 0.891) and for the physical limitation, emotional impact, and social limitation domains (α = 0.815-0.950). Test-retest reliability was excellent or strong for the overall TASQ (intraclass correlation coefficient of 0.883) and for the physical symptoms, physical limitation, emotional impact, and social limitation domains (intraclass correlation coefficient of 0.791-0.895). Responsiveness was medium overall (Cohen's d = 0.637) and medium/large for physical symptoms, emotional impact, and physical limitations (0.661-0.812). Sensitivity to change was significant for physical symptoms, physical limitations (both P < 0.001), emotional impact (P = 0.003), and social limitations (P = 0.038). CONCLUSIONS: The TASQ is a new, brief, self-administered, and clinically relevant health-specific tool to measure changes in quality of life in patients with AS undergoing an intervention.


Assuntos
Estenose da Valva Aórtica , Qualidade de Vida , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Canadá , Europa (Continente) , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Resultado do Tratamento
9.
Circ Cardiovasc Interv ; 12(10): e007924, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31554422

RESUMO

BACKGROUND: Recent trials suggest that complete revascularization in patients with acute ST-segment-elevation myocardial infarction and multivessel disease is associated with better outcomes than infarct-related artery (IRA)-only revascularization. There are different methods to select non-IRA lesions for revascularization procedures. We assessed the clinical outcomes of complete angiographically guided revascularization versus stress echocardiography-guided revascularization in patients with ST-segment-elevation myocardial infarction. METHODS: We performed a randomized clinical trial in patients with multivessel disease who underwent a successful percutaneous coronary intervention of the IRA to test differences in prognosis (composite end point included cardiovascular mortality, nonfatal reinfarction, coronary revascularization, and readmission for heart failure after 12 months of follow-up) between complete angiographically guided revascularization (n=154) or stress echocardiography-guided revascularization (n=152) of the non-IRA lesions in an elective procedure before hospital discharge. RESULTS: The trial was prematurely stopped after the inclusion of 77% of the planned study population. As many as 152 (99%) patients in the complete revascularization group and 44 (29%) patients in the selective revascularization group required a percutaneous coronary intervention procedure of a non-IRA lesion before discharge. The primary end point occurred in 21 (14%) patients of the stress echocardiography-guided revascularization group and 22 (14%) patients of the complete angiographically guided revascularization group (hazard ratio, 0.95; 95% CI, 0.52-1.72; P=0.85). CONCLUSIONS: In patients with ST-segment-elevation myocardial infarction and multivessel disease, stress echocardiography-guided revascularization may not be significantly different to complete angiographically guided revascularization, thereby reducing the need for elective revascularization before hospital discharge. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01179126.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia sob Estresse , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Término Precoce de Ensaios Clínicos , Teste de Esforço , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Recidiva , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Espanha , Fatores de Tempo , Resultado do Tratamento
10.
Open Heart ; 6(1): e001008, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31218003

RESUMO

Background: Patients with severe aortic stenosis (AS) have a reduced life expectancy and quality of life (QoL), owing to advanced age and the presence of multiple comorbidities. Currently, there is no AS-specific QoL measurement tool, which prevents an accurate assessment of how this chronic condition and its treatment affect patients. The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) was developed in order to address this deficiency. Methods: The present trial protocol was designed to enable validation of the TASQ, which has been produced in five languages (English, French, German, Italian and Spanish) to increase usability. Patients with severe AS who are undergoing surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI) will be asked to complete the TASQ and, for comparative purposes, the Kansas City Cardiomyopathy Questionnaire and the general health-related QoL Short Form-12 questionnaire. The questionnaires will be completed prior to the intervention, at discharge, as well as at 30 days and 3 months follow-up. A total of 290 patients will be recruited across one Canadian and nine European centres. Overall, the protocol validation aims to include 120 patients undergoing transfemoral TAVI (TF-TAVI), 120 undergoing SAVR and up to 50 being treated medically. The primary objective of the registry is to validate the TASQ in five different languages. The secondary objective is to assess the utility of the TASQ for assessing differences in QoL outcome between patients undergoing TF-TAVI, SAVR or medical management for their AS. Discussion: Validation and roll-out of the TASQ will enable clinicians to capture an accurate assessment of how AS and its management affects the QoL of patients and will help them to determine the most appropriate treatment strategy for individual patients. Trial registration number: NCT03186339.

11.
Am Heart J ; 155(4): 648-53, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18371471

RESUMO

BACKGROUND: Late thrombosis is the major safety concern of drug-eluting stents, but its incidence in common clinical practice remains controversial to date, especially beyond the first year after stent implantation. We sought to investigate the incidence, clinical consequences, and risk factors of late thrombosis after drug-eluting stent implantation. METHODS: Consecutive patients (N = 604) who received > or = 1 paclitaxel-eluting stent(s) (PES) between June 2003 and February 2005 at our institution were enrolled. Clinical characteristics and major outcomes were reviewed to detect cases and predictors of late and very late definite PES thrombosis (LDT) of PES, as currently defined by the Academic Research Council. RESULTS: During long-term follow-up (median 34.3 months, IQR 8.6), 17 cases of LDT were noted (cumulative incidence 2.8%, 95% CI 1.7%-4.5%). Most of LDT were very late thromboses (14 cases, 82%). Late and very late definite PES thrombosis appeared at a steady rate (incidence density 1.1% patient-years). Late and very late definite PES thrombosis was related to a high risk of all-cause death (HR 3.2, 95% CI 1.3-7.9) and cardiac death (HR 6.0, 95% CI 2.3-15.6). Withdrawal of antiplatelet therapy, left ventricular ejection fraction, and average stent diameter per patient were independent predictors of LDT in multivariate analysis. CONCLUSIONS: Late and very late definite PES thrombosis may be more frequent in a real setting than anticipated by initial experimental and observational studies but is keeping with more recent scientific evidence. It seems to occur at a constant rate during long-term follow-up and is associated with a high risk of overall and cardiac death.


Assuntos
Doença das Coronárias/terapia , Trombose Coronária/epidemiologia , Stents Farmacológicos/efeitos adversos , Paclitaxel/administração & dosagem , Idoso , Doença das Coronárias/mortalidade , Reestenose Coronária/epidemiologia , Esquema de Medicação , Quimioterapia Combinada , Feminino , Seguimentos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco , Estatísticas não Paramétricas
13.
J Eval Clin Pract ; 21(1): 34-42, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25040767

RESUMO

RATIONALE, AIMS AND OBJECTIVES: Transcatheter aortic valve implantation constitutes an example of a technology introduced into the Galician Health Care System basket and subjected to a post-introduction observational study after coverage. This paper aims to describe the process and results of this experience, illustrating the main challenges and opportunities in using these studies for supporting decision making. METHODS: The study protocol was developed by a multidisciplinary team consisting of experts from the Galician HTA Agency (avalia-t), interventional cardiologists and cardiac surgeons. Together they agreed on the information that was relevant and feasible for collection, and planned the study design, data collection and analysis of results. RESULTS: During the 1-year recruitment period, 94 patients underwent percutaneous aortic valve replacement in the three authorized centres. Implantation rate and prosthesis models differed substantially across the centres. Overall, procedural success rate was 96.8% and hospital mortality was 7.4%. Complications during post-surgical admission were recorded in 40.4% of patients. Moderate residual aortic regurgitation was observed in 10% of patients, and the procedure was associated with a stroke rate of 3.3% at 30 days and 5.3% at 1 year. CONCLUSIONS: Post-introduction observation has made it feasible to determine the use of this procedure within the SERGAS context and has enabled the assessment of performance in real-life conditions. The proposed strategic actions and interventions have been drawn up based upon the collective judgement of a group of experienced professionals, and have served to establish recommendations on further research that would be required to optimize health benefits.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Espanha , Fatores de Tempo
15.
Rev Esp Cardiol ; 56(2): 152-9, 2003 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-12605760

RESUMO

INTRODUCTION: The transradial approach has emerged as an attractive alternative to the femoral approach for coronary angiography and interventions. We describe our experience with the transradial approach and analyze the influence of the learning curve. PATIENTS AND METHODS: The transradial approach was attempted in patients with a good radial pulse and normal Allen test. When feasible and clinically indicated, we attempted ad hoc intervention. We divided the study population into two groups: Group A (the first 200 cases) and B (all other patients). We compared the radial group with a matched femoral control group. RESULTS: We attempted the transradial approach in 526 patients (77.6% male; age 63.5 +/- 11.51), and obtained a success rate of 93.7%. We found differences between group A and B in the success rate (91.0 vs 95.4%, p = 0,04), duration of procedure [23 (16-29) vs. 19 (15-24) minutes; p < 0.001], and fluoroscopy time [6.4 (4.2-10) vs. 5.0 (3.0-7.7) minutes; p < 0,001]. At 24 h of follow-up, we found small hematomas in 9.4%, bleeding in 4.9%, and radial artery obstruction in 2.8%, with no cases of arteriovenous fistula, pseudoaneurysm, or need for vascular surgery. We attempted intervention in 169 patients with 258 lesions, achieving angiographic success in 96.1%. We found no differences in the characteristics of the lesions and patients, or in the angiographic success rate of the radial and femoral PTCA groups. CONCLUSIONS: The transradial approach is a safe and effective alternative to femoral catheterization. There is a significant learning curve associated with the successful performance of transradial procedures.


Assuntos
Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Artéria Radial , Angioplastia Coronária com Balão/educação , Cateterismo Cardíaco/métodos , Cateteres de Demora/estatística & dados numéricos , Feminino , Artéria Femoral , Humanos , Aprendizagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias
16.
Rev Esp Cardiol ; 56(1): 57-64, 2003 Jan.
Artigo em Espanhol | MEDLINE | ID: mdl-12550001

RESUMO

OBJECTIVES: Previous studies have shown the usefulness of dobutamine echocardiography to differentiate dilated cardiomyopathy (DC) from ischemic left ventricular dysfunction (ILVD), but no studies have been made using exercise echocardiography (EE). We hypothesized that most patients with DC have some contractile reserve and experience an increase in left ventricular ejection fraction (LVEF) during exercise, as opposed to patients with ILVD. Differences in response to EE may be useful to clinically differentiate between these two entities. PATIENTS AND METHOD: Between 1 March 1995 and 1 March 2001, we performed 4,133 EE studies on 3,830 patients. Of 289 patients (8%) with moderate or severe LV dysfunction (biplane LVEF < 41% and left ventricular end-diastolic diameter > 5.2 cm), 207 were excluded: 111 for a history of myocardial infarction; 28 for scarring on echocardiography (regional akinesia/dyskinesia with thinning and/or increased brightness); 13 for previous revascularization procedures; 9 for aortic valve disease; 11 for a known cause of cardiomyopathy; and 35 for not undergoing angiography. The study group was therefore composed of 82 patients who were encouraged to perform maximal treadmill EE. EE criteria for ILVD were either impaired regional wall motion (RWM) or a decrease/no change in LVEF from baseline to peak exercise, while criteria for DC were RWM improvement/no change and LVEF increase. The ILVD group was formed by 39 patients with stenosis >/= 70% diameter stenosis of a major epicardial coronary artery or major branch vessel. The remaining 43 patients constituted the DC group. RESULTS: The number of coronary risk factors (ILVD 2.0 1.1; DC 1.9 1.1), baseline LVEF (ILVD 30 7; DC 30 8), and exercise-induced angina (ILVD 23%; DC 14%) did not differ between groups (p = NS). ILVD patients achieved less Mets (6.6 3.1 vs 8.3 2.8; p < 0.05), had a lower heart rate x systolic blood pressure product (22 5 vs 27 7; p < 0.001), and developed regional and/or global LV dysfunction more frequently (79 vs 28%; p < 0.001). Sensitivity, specificity, positive and negative predictive values and global accuracy for ILVD detection were 79% (95% CI: 70-88), 72% (95% CI: 63-81), 72% (95% CI: 63-81), 79% (95% CI: 67-85), and 76% (95% CI: 69-83), respectively. CONCLUSION: Global and/or regional LV function impairment with exercise is accurate in identifying patients with ILVD. This method could reduce the need for invasive procedures.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Teste de Esforço/métodos , Isquemia Miocárdica/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Angiografia Coronária , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
17.
Am J Cardiol ; 113(6): 907-12, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24461770

RESUMO

The presence of mitral regurgitation (MR) is associated with an impaired prognosis in patients with ischemic heart disease. However, data with regard to the impact of this condition in patients with ST-segment elevation myocardial infarction (STEMI) treated by means of primary percutaneous coronary intervention (PPCI) are lacking. Our aim was to assess the effect of MR in the long-term prognosis of patients with STEMI after PPCI. We analyzed a prospective registry of 1,868 patients (mean age 62 ± 13 years, 79.9% men) with STEMI treated by PPCI in our center from January 2006 to December 2010. Our primary outcome was the composite end point of all-cause mortality or admission due to heart failure during follow-up. After exclusions, 1,036 patients remained for the final analysis. Moderate or severe MR was detected in 119 patients (11.5%). Those with more severe MR were more frequently women (p <0.001), older (p <0.001), and with lower ejection fraction (p <0.001). After a median follow-up of 2.8 years (1.7 to 4.3), a total of 139 patients (13.4%) experienced our primary end point. There was an association between the unfavorable combined event and the degree of MR (p <0.001). After adjustment for relevant confounders, moderate or severe MR remained as an independent predictor of the combined primary end point (adjusted hazard ratio [HR] 3.14, 95% confidence interval [CI] 1.57 to 6.27) and each event separately (adjusted HR death 3.1, 95% CI 1.34 to 7.2; adjusted HR heart failure 3.3, 95% CI 1.16 to 9.4). In conclusion, moderate or severe MR detected early with echocardiography was independently associated with a worse long-term prognosis in patients with STEMI treated with PPCI.


Assuntos
Eletrocardiografia , Insuficiência da Valva Mitral/etiologia , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/métodos , Idoso , Causas de Morte/tendências , Angiografia Coronária , Ecocardiografia Doppler em Cores , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Prognóstico , Estudos Prospectivos , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo
18.
World J Cardiol ; 6(6): 424-33, 2014 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-24976914

RESUMO

Primary percutaneous coronary intervention (PPCI) is the preferred reperfusion therapy for patients presenting with ST-segment elevation myocardial infarction (STEMI) when it can be performed expeditiously and by experienced operators. In spite of excellent clinical results this technique is associated with longer delays than thrombolysis and this fact may nullify the benefit of selecting this therapeutic option. Several strategies have been proposed to decrease the temporal delays to deliver PPCI. Among them, prehospital diagnosis and direct transfer to the cath lab, by-passing the emergency department of hospitals, has emerged as an attractive way of diminishing delays. The purpose of this review is to address the effect of direct transfer on time delays and clinical events of patients with STEMI treated by PPCI.

20.
J Invasive Cardiol ; 25(2): 92-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23388229

RESUMO

Significant periprosthetic aortic regurgitation after transcatheter aortic valve implantation with Edwards SAPIEN prosthesis has become a major concern of this technique given its association with impaired survival. We report the successful closure of such defects using vascular occlusion devices with significant improvement in clinical status of patients.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia Transesofagiana , Fluoroscopia , Seguimentos , Humanos , Masculino , Falha de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA