Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Eur J Ophthalmol ; 17(4): 571-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17671933

RESUMO

PURPOSE: To study the relationship between pupil size and AMO-Array multifocal intraocular lens (MIOL) performance in a population of elderly patients. METHODS: This prospective trial included 62 patients (mean age 76 years; range 70 to 86) undergoing bilateral cataract phacoemulsification and MIOL (AMO-Array SA-40N, Allergan) implantation. Patients were divided into two groups based on preoperative pupil diameter: small pupil group (pupil size of 2.5-2.9 mm; 45 subjects) and large pupil group (pupil size of 3-5 mm; 17 subjects). The analysis included uncorrected (UC) and best-corrected (BC) near and distance visual acuity (VA), spectacle dependence, and photic phenomena complaints (postoperative follow-up 16.6+/-6.2 months; range 11-26 months). RESULTS: Patients in the small pupil group showed postoperatively significantly higher distance UCVA and BCVA, but lower near UCVA compared to those in the large pupil group (Mann-Whitney test, p< or = 0.02). Patients with small pupils also tended to: be more (not statistically significant) spectacle independent for distance (73.3% versus 47.1%) and spectacle-dependent for near vision (55.6% versus 28.4%); report significantly less photic phenomena complaints (37.8% versus 93.1%, chisquare test, p<0.001); and, more satisfied with the surgery (95.5% versus 76.5%). Posterior capsular opacification (PCO) was observed in 19.4% of the patients. CONCLUSIONS: Bilateral AMO-Array MIOL implantation in elderly patients seems to be an effective and safe surgical procedure that improves distance and near UCVA, providing spectacle independence in many cases. The use of these MIOLs, however, can induce photic phenomena and cause PCO. Patients with small preoperative pupils (<3 mm) presented less photic phenomena complaints and expressed a higher visual outcome satisfaction after surgery.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Pseudofacia/fisiopatologia , Pupila/fisiologia , Idoso , Idoso de 80 Anos ou mais , Catarata/complicações , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
2.
Eye (Lond) ; 30(6): 784-95, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27174381

RESUMO

PurposeTo evaluate the ability of baseline clinical, morphological, and functional factors to predict the conversion to primary open-angle glaucoma (POAG) in ocular hypertensive (OHT) patients.MethodsThis single-center prospective longitudinal observational study included 116 eyes of 116 OHT patients followed for a 10-year period. All patients had intraocular pressure (IOP) ≥24 mm Hg in one eye and >21 mm Hg in the other eye, normal visual fields (VFs) and normal optic disc (OD) appearance in both eyes at baseline. All OHT patients were untreated at baseline with subsequent treatment upon need according to clinical judgement. Only one eye per subject was randomly selected. Patient age, gender, IOP, central corneal thickness (CCT), and ibopamine test results were collected at baseline. All patients underwent standard automated perimetry, short-wavelength automated perimetry (SWAP), frequency-doubling technology, confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) at baseline and every 6 months thereafter. Main outcome measure was the conversion to POAG, defined as the development of reproducible VF and/or OD abnormalities attributable to glaucoma. Cox proportional hazards models were used to identify the baseline factors predictive of POAG conversion.ResultsDuring the 10-year follow-up, 25% of eyes converted to POAG. In multivariate Cox models, baseline factors that were significant predictors of POAG development included: older age (hazard ratio (HR) 1.0, 99% confidence intervals (CIs) 1.0-1.2, per 1 year older); SWAP Glaucoma Hemifield test 'outside normal limits' (HR 4.3, 99% CIs 1.2-17.9); greater SLP 'Inter-eye Symmetry' (HR 1.1, 99% CIs 0.4-3.0, per 1 unit lower); lower CSLO Rim Volume (HR 1.1, 99% CIs 0.3-3.2, per 0.1 mm(3) lower); and greater CSLO cup-to-disc ratio (HR 6.0, 99% CIs 3.6-16.8, per 0.1 unit greater).ConclusionsThe baseline parameters that proved to be useful in assessing the likelihood of an OHT patient to develop POAG included age, functional variables provided by SWAP, and structural variables provided by SLP and CSLO. In this cohort of patients, baseline IOP, CCT, and ibopamine provocative test results were not significant predictors of POAG conversion.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Hipertensão Ocular/diagnóstico , Idoso , Desoxiepinefrina/administração & dosagem , Desoxiepinefrina/análogos & derivados , Progressão da Doença , Feminino , Seguimentos , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Midriáticos/administração & dosagem , Oftalmoscopia , Estudos Prospectivos , Fatores de Risco , Tonometria Ocular , Testes de Campo Visual , Campos Visuais/fisiologia
3.
Br J Ophthalmol ; 89(2): 180-4, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15665349

RESUMO

AIM: To compare rarebit perimetry (RBP) with standard achromatic perimetry (SAP) in detecting early glaucomatous functional damage. METHODS: 43 patients with ocular hypertension (OH), 39 with early primary open angle glaucoma (POAG), and 41 controls were considered. Visual fields were assessed using the Humphrey field analyser (HFA) 30-2 and RBP tests. Differences among the groups were evaluated using Student-Newman-Keuls and chi(2) tests. Correlation between HFA and RBP parameters was assessed using the Pearson's correlation coefficients and regression analysis. Sensitivity and specificity of RBP in detecting early glaucomatous visual damage were calculated with different algorithms. RESULTS: RBP-mean hit rate (MHR) was respectively 88.6% (SD 4.8%) in controls; 79.1% (10.9%) in the OH group; 64.3% (13.8%) in the POAG group (differences statistically significant). Good correlation in the POAG group was found between HFA-mean deviation and RBP-MHR. Largest AROC (0.95) and optimal sensitivity (97.4%) were obtained when an abnormal RBP test was defined as having (at least 1): MHR <80%; >15 areas with a non-hit rate of >10%; > or =2 areas with a non-hit rate of >50%; at least one area with a non-hit rate of > or =70%. CONCLUSIONS: The RBP appeared to be a rapid, comfortable, and easily available perimetric test (requiring only a PC device), showing a high sensitivity and specificity in detecting early glaucomatous visual field defects.


Assuntos
Hipertensão Ocular/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos , Adulto , Idoso , Algoritmos , Feminino , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/complicações , Hipertensão Ocular/fisiopatologia , Análise de Regressão , Sensibilidade e Especificidade , Transtornos da Visão/etiologia , Campos Visuais/fisiologia
4.
Eur J Ophthalmol ; 15(4): 468-76, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16001380

RESUMO

PURPOSE: To evaluate the ability of scanning laser polarimetry (SLP) with a fixed corneal polarization compensator (GDx-FCC Nerve Fiber Analyzer) compared to one with a variable one (GDx-VCC) in the discrimination between healthy and early glaucomatous eyes. METHODS: Forty patients with early glaucomatous visual field defects, having a mean deviation of 3.1-/+1.6 dB and a pattern standard deviation of 3.1-/+0.9 dB, and 40 controls underwent both GDx-FCC and GDx-VCC. One eye per patient was considered. The cut-off point, taken as the value dividing healthy from glaucomatous eyes with highest probability, was determined for each GDx parameter. Linear discriminant functions (LDFs) were separately developed for GDx-FCC and GDx-VCC parameters. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) for discriminating between healthy and glaucomatous eyes were calculated for each GDx parameter, both according to the GDx normative database and after the selection of new cut-off points, and for the LDFs. RESULTS: All software-provided parameters showed low sensitivity and high specificity. The selection of new cut-off points improved the performance of all GDx parameters: VCC parameters performed better than FCC parameters; the largest AROCs were associated with the superior/nasal ratio for the GDx-FCC (0.86) and with the Number for the GDx-VCC (0.87). The LDFs provided an AROC of 0.89 with both the GDx-FCC and the GDx-VCC parameters. CONCLUSIONS: The GDx-VCC showed a higher ability in the early diagnosis of glaucoma when compared with the GDx-FCC. The individuation of the right cut-off point of selected parameters with both GDx settings performed better than the software-provided parameters, and comparably to the GDx parameters-based LDFs.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ângulo Aberto/diagnóstico , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Células Ganglionares da Retina/patologia , Adulto , Idoso , Área Sob a Curva , Birrefringência , Córnea/fisiologia , Humanos , Lasers , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Cataract Refract Surg ; 27(5): 720-7, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11377903

RESUMO

PURPOSE: To compare astigmatic and topographic changes induced by different oblique cataract incisions. SETTING: Department of Ophthalmology, Hospital of San Donà di Piave, Venice, Italy. METHODS: One hundred sixty-eight eyes having phacoemulsification were randomly assigned to 1 of 3 groups: 3.5 mm clear corneal incision (CCI), 60 eyes; 5.5 mm sutured CCI, 54 eyes; 5.5 mm scleral tunnel, 54 eyes. Incisions lay on the 120 degree semimeridian. Corneal topography was performed preoperatively and 1 week and 1 and 3 months postoperatively. Simulated keratometric readings were used to calculate astigmatism amplitude and surgically induced astigmatism (SIA). Postoperative topographic changes were determined by subtracting the preoperative from the postoperative numeric map readings. RESULTS: Three months postoperatively, the mean SIA in the right and left eyes, respectively, was 0.68 diopter (D) +/- 1.14 (SD) and 0.66 +/- 0.52 D in the 3.5 mm CCI group, 1.74 D +/- 1.43 D and 1.64 +/- 1.27 D in the 5.5 mm CCI group, and 0.46 +/- 0.56 D and 0.10 +/- 1.08 D in the scleral tunnel group. Right and left eyes showed similar SIA amplitude but different SIA axis orientation. The SIA was significantly higher in the 5.5 mm CCI group than in the other 2 groups 1 and 3 months postoperatively (P <.01). All groups showed significant wound-related flattening and nonorthogonal steepening at 2 opposite radial sectors. Topographic changes were significantly higher in the 5.5 mm CCI group and significantly lower in the scleral tunnel group. CONCLUSIONS: Right and left eyes showed similar SIA amplitude but different SIA axis orientation and topographic modifications, probably because of the different superotemporal and superonasal corneal anatomic structure. The 5.5 mm CCI induced significantly higher postoperative astigmatism, SIA, and topographic changes.


Assuntos
Astigmatismo/etiologia , Topografia da Córnea , Facoemulsificação/efeitos adversos , Técnicas de Sutura/efeitos adversos , Idoso , Astigmatismo/diagnóstico , Córnea/patologia , Córnea/cirurgia , Feminino , Humanos , Masculino , Facoemulsificação/métodos , Polimetil Metacrilato , Estudos Prospectivos , Esclera/cirurgia , Elastômeros de Silicone , Retalhos Cirúrgicos
6.
Eur J Ophthalmol ; 12(3): 219-24, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12113568

RESUMO

PURPOSE AND METHODS: In order to avoid the complications associated with posterior chamber intraocular lens (IOL) scleral fixation, the authors have developed an original surgical technique by which the IOL is secured at the ciliary sulcus by suturing the haptics to the sclera in three points (at the 3, 5 and 9 o'clock positions). This technique was utilized for secondary IOL implantation in 21 aphakic eyes. The mean follow-up was 18 months, range 6-28 months. RESULTS: All eyes that underwent secondary implants had equal or better visual acuity postoperatively; none developed serious intra- or postoperative complications. No tilt or decentration of the IOL was observed postoperatively. DISCUSSION: The technique described appeared easy to perform and produced good visual outcomes with stable transscleral fixation of the IOL.


Assuntos
Corpo Ciliar/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Esclera/cirurgia , Técnicas de Sutura , Idoso , Idoso de 80 Anos ou mais , Afacia Pós-Catarata/cirurgia , Criança , Humanos , Pessoa de Meia-Idade , Facoemulsificação , Polimetil Metacrilato , Polipropilenos , Suturas , Acuidade Visual
7.
Eur J Ophthalmol ; 13(6): 536-40, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12948311

RESUMO

PURPOSE: To compare the efficacy and tolerance of piroxicam 0.5% ophthalmic solution and diclofenac sodium 0.1% ophthalmic solution in controlling inflammation after phacoemulsification and intraocular lens (IOL) implantation. SETTING: Ophthalmological Department, San Donà di Piave Hospital, Venice, Italy. MATERIALS AND METHODS: Forty consecutive patients--18 men and 22 women--between 55 and 85 years of age (mean age, 75.1 +/- 7.12 years) who were scheduled for cataract extraction with phacoemulsification and IOL implantation were randomized to receive 0.5% piroxicam ophthalmic solution (piroxicam group, 20 patients) or 0.1% diclofenac sodium ophthalmic solution (diclofenac group, 20 patients) for 1 month postoperatively. Best-corrected visual acuity (BCVA) and intraocular pressure (IOP) measurements and slit-lamp biomicroscopy for the evaluation of corneal edema, Descemet membrane folds, Tyndall, and cells in the anterior chamber were carried out in all patients 1 day, 4 days, and 1 month postoperatively. Subjective symptoms after the nonsteroidal anti-inflammatory drug (NSAID) ophthalmic solution instillation were assessed using a questionnaire. RESULTS: There were no significant differences between the two groups in postoperative IOP, BCVA, anterior chamber flare and cell levels, corneal edema, or Descemet membrane folds. Ocular discomfort, evaluated as burning or stinging sensation after NSAID ophthalmic solution instillation, was significantly more frequent and intense in the diclofenac-treated eyes. Two eyes in the diclofenac group had a mild transient punctate keratitis. CONCLUSIONS: These results suggest that piroxicam is as effective as diclofenac sodium in preventing inflammation after cataract surgery with IOL implantation, and its better tolerance and safety can provide higher patient compliance.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Diclofenaco/administração & dosagem , Facoemulsificação , Piroxicam/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Uveíte Anterior/prevenção & controle , Administração Tópica , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/efeitos adversos , Diclofenaco/efeitos adversos , Método Duplo-Cego , Feminino , Humanos , Pressão Intraocular/efeitos dos fármacos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas/administração & dosagem , Soluções Oftálmicas/efeitos adversos , Piroxicam/efeitos adversos , Estudos Prospectivos , Segurança , Resultado do Tratamento , Acuidade Visual
8.
Eur J Ophthalmol ; 12(5): 388-94, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12474921

RESUMO

PURPOSE: To compare the posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) laser posterior capsulotomy rates associated with three different posterior chamber foldable intraocular lenses (IOL). METHODS: We retrospectively evaluated the rates of PCO and Nd:YAG laser capsulotomy in 1150 eyes two years after standard phacoemulsification with a no-stitch 3.5mm clear corneal incision (CCI) and in-the-bag implantation of one of three types of IOL: 190 eyes received a one-piece round-edged hydrogel IOL (Hydroview H60M, Bausch & Lomb); 475 eyes a three-piece round-edged silicone IOL (AMO PhacoFlex SI-40NB, Allergan); 485 eyes a three-piece square-edged soft acrylic lens (AcrySof MA60MA, Alcon). RESULTS: The PCO and Nd:YAG laser capsulotomy rates were respectively 43.15% and 20.5% in the Hydroview H60M group, 27.57% and 9.68% in the AMO PhacoFlex SI-40NB group, 10.5% and 2.47% in the AcrySof MA60MA group. CONCLUSIONS: PCO and Nd:YAG laser capsulotomy rates were significantly higher in the Hydroview H60M group and significantly lower with the AcrySof MA60MA lenses, which combine a bioactive constitutive material with the square-edged optic design.


Assuntos
Extração de Catarata , Catarata/etiologia , Terapia a Laser , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular/efeitos adversos , Acrilatos , Idoso , Feminino , Seguimentos , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Silicones
9.
Eur J Ophthalmol ; 13(1): 62-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12635676

RESUMO

PURPOSE: To retrospectively review the safety and efficacy of black-diaphragm intraocular lenses (IOL) implanted for the treatment of post-traumatic aniridia. METHODS: Ten patients (mean age 48 years, range 21-75) were implanted with a black-diaphragm posterior chamber IOL (Morcher GmbH, model 67F) for correction of post-traumatic aniridia associated with cataract or aphakia. This IOL, in poly(methylmethacrylate), consists of an opaque diaphragm surrounding the transparent optic, and was inserted through a 10-mm scleral tunnel (seven eyes) or through the corneal trephination in cases of simultaneous penetrating keratoplasty (three eyes), and in-the-sulcus implanted, trans-sclerally sutured (six eyes) or on capsular support (four eyes). Mean follow-up was 33.4 months (range 12-52). RESULTS: Best-corrected visual acuity (BCVA) improved in eight eyes and remained unchanged in two. Glare and photophobia decreased in all patients. Intraoperatively, ciliary sulcus bleeding occurred in two cases and haptic rupture during lens insertion in one. Postoperatively, persistent intraocular inflammation was seen in four eyes, secondary glaucoma in four eyes, transient hyphema and/or hemovitreous in four, IOL decentration in two, and post-traumatic haptic detachment in one eye. CONCLUSIONS: Although in our experience the haptics still seem weak and the diaphragm diameter too large, implantation of the black-diaphragm IOL type 67F appeared sufficiently safe and provided satisfactory functional results for correction of post-traumatic aniridia combined with cataract or aphakia, improving BCVA and reducing glare and photophobia in most patients, though clearly more cases and longer follow-up are needed to assess its clinical performance properly.


Assuntos
Aniridia/cirurgia , Traumatismos Oculares/cirurgia , Iris/lesões , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Complicações Pós-Operatórias , Adulto , Idoso , Aniridia/etiologia , Materiais Biocompatíveis , Traumatismos Oculares/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Polimetil Metacrilato , Desenho de Prótese , Estudos Retrospectivos , Segurança , Resultado do Tratamento , Acuidade Visual
10.
Eye (Lond) ; 25(5): 642-50, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21436848

RESUMO

PURPOSE: To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP. METHODS: This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland-Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP. RESULTS: iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of -6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes. CONCLUSIONS: The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP.


Assuntos
Córnea , Doenças da Córnea/diagnóstico , Doenças da Córnea/cirurgia , Pressão Intraocular/fisiologia , Ceratoplastia Penetrante , Tonometria Ocular/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/diagnóstico , Astigmatismo/fisiopatologia , Córnea/anatomia & histologia , Córnea/patologia , Transplante de Córnea , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Cuidados Pós-Operatórios , Estudos Prospectivos , Tonometria Ocular/normas
11.
Eye (Lond) ; 24(5): 835-42, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19696803

RESUMO

PURPOSE: To compare the ability of frequency-doubling technology (FDT), rarebit perimetry (RBP), and pulsar perimetry (PP) in detecting early glaucomatous functional damage. METHODS: This prospective observational cross-sectional case study included 52 patients with early primary open-angle glaucoma (mean deviation -2.3+/-1.1 dB; pattern standard deviation 3.0+/-1.2 dB) and 53 healthy controls. Visual field (VF) testing included standard automated perimetry (SAP) Humphrey Field Analyzer 30-2, FDT N-30, RBP (version 4.0), and PP T30W. One eye per patient was considered. Sensitivity at fixed specificities and area under the receiver operating characteristic curve (AROC) for discriminating between healthy and glaucomatous eyes were calculated and compared. RESULTS: The parameters associated with the largest AROC, which were not statistically different (Hanley-McNeil method, P0.42-0.71) were as follows: number of locations in the pattern deviation probability (PDP) plot with P<5% for FDT (0.93); mean hit rate for RBP (0.95); and mean defect for PP (0.94). PP test duration was significantly shorter than FDT and RBP (P<0.002). CONCLUSIONS: FDT, PP, and RBP are useful non-conventional VF methods in detecting early glaucomatous VF defects with similar AROCs. The methods were rapid and easy, and PP took less than half the time than SAP. These non-conventional testing may prove to be useful in providing additional information in the diagnosis of glaucoma suspect with normal SAP results, in the therapeutic decision-making process of early glaucomatous patients, and in subjects unable to perform VF testing with SAP.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais , Idoso , Estudos Transversais , Diagnóstico Precoce , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
13.
Eye (Lond) ; 22(3): 406-13, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17304263

RESUMO

AIM: To compare Stratus-OCT measurements in controls, ocular hypertensive (OHT) patients with (FDT+) and without (FDT-) frequency-doubling technology (FDT) abnormalities, and in patients affected with early primary open-angle glaucoma (POAG). METHODS: Thirty-two controls, 78 OHT patients (38 FDT- and 40 FDT+), and 45 early POAG patients (six FDT- and 39 FDT+) underwent the following tests within 3 months: standard automated perimetry (SAP) HFA 30-2; FDT N-30-F; and, Stratus-OCT imaging with retinal nerve fibre layer (RNFL) and optic nerve head (ONH) scans. One eye per patient was considered. Differences among groups were evaluated using the Kruskal-Wallis, analysis of variance, and Duncan's tests. RESULTS: There were no significant differences in all Stratus-OCT parameters between POAG and OHT FDT+ patients. Statistically significant differences were found between the control group and both the POAG and OHT FDT+ groups for 15 of the 21 Stratus-OCT parameters. Control eyes compared to OHT FDT- showed significant differences in 13 of the 21 parameters. The comparison between the OHT FDT- group, and both the POAG and OHT FDT+ group resulted in 13 of the 21 parameters to be significantly different. CONCLUSIONS: Stratus-OCT seems to show a higher ability in detecting significant differences between healthy, OHT, and early POAG eyes when compared to SAP and FDT. This suggests that the Stratus-OCT could show structural abnormalities before SAP or FDT visual field defects appear in patients at risk of developing glaucoma, which may be beneficial in making therapeutic decisions, especially in OHT patients.


Assuntos
Hipertensão Ocular/diagnóstico , Tomografia de Coerência Óptica/métodos , Testes de Campo Visual/métodos , Adulto , Idoso , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Disco Óptico/ultraestrutura , Retina/ultraestrutura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA