Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577931

RESUMO

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Espanha , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
J Cardiovasc Pharmacol ; 77(2): 164-169, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33351537

RESUMO

BACKGROUND: Clinical trials have assessed the effect of direct oral antagonists (DOACs) in patients with atrial fibrillation (AF) after percutaneous coronary interventions (PCI). Studies were designed to test the effect on bleeding incidence, but concerns related to safety on ischemic events remain. METHODS: We performed a meta-analysis with currently available studies involving DOACs versus Vitamin-K antagonist (VKA) in patients with AF after PCI. The primary endpoint was the incidence of cardiac ischemic events, including myocardial infarction and stent thrombosis. Secondary endpoints were the incidence of stroke, all-cause mortality, and major bleeding. RESULTS: Eleven thousand twenty-three patients were included in the analysis: 5510 receiving DOACs and 5513 VKA. A total of 190 cases of myocardial infarction were registered in patients treated with DOACs and 177 in patients on VKA, and no statistical difference was noted [relative risk (RR): 1.07 95% confidence interval (CI) 0.88-1.31]. The incidence of stent thrombosis was very low with no differences between both treatment strategies (RR: 1.14 95% CI 0.76-1.71). The incidence of cardiac ischemic events was the same in patients receiving DOACs or VKA (HR 1.09 95% CI 0.91-1.30). No differences were observed in the incidence of stroke (RR: 0.86 95% CI 0.61-1.23) or mortality (RR: 1.09, 95% CI 0.90-1.31). Treatment with DOACs was associated with 34% reduction in major bleeding (RR: 0.66, 95% CI 0.54-0.81). CONCLUSIONS: Treatment with DOACs in patients with AF after a PCI do not increase the risk of cardiac ischemic events, stroke, or death and reduce the incidence of major bleeding by 34% as compared with VKA.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Vitamina K/antagonistas & inibidores , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Trombose Coronária/mortalidade , Inibidores do Fator Xa/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Incidência , Infarto do Miocárdio/mortalidade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Medição de Risco , Fatores de Risco , Stents , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
3.
Echocardiography ; 37(4): 586-591, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32212399

RESUMO

INTRODUCTION: Limited data are available regarding the evaluation of right ventricular (RV) performance in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). OBJECTIVE: To evaluate the prevalence of RV dysfunction in patients with severe AS undergoing TAVI and long-term changes. METHODS: Consecutive patients with severe AS undergoing TAVI from January 2016 to July 2017 were included. RV anatomical and functional parameters were analyzed: RV diameters, fractional area change, tricuspid annular plane systolic excursion (TAPSE), S-wave tissue Doppler of the tricuspid annulus (RV-S'TDI), global longitudinal strain (RV-GLS), and free wall strain (RV-FWS). Preprocedure and 1-year echo were analyzed. RESULTS: Final population included 114 patients, mean age 83.63 ± 6.31 years, and 38.2% women. The prevalence of abnormal RV function was high, variable depending on the parameter that we analyzed, and it showed a significant reduction 1 year after TAVI implantation: 13.9% vs 6.8% (TAPSE < 17mm), P = .04; 26.3% vs 20% (fractional area change < 35%), P = .048; 41.2% vs 29.2% (RV-S'TDI < 9.5cm/s), P = .04; 48.7% vs 39.5% (RV-GLS > [20]), P = .049; and 48.7% vs 28.9% (RV-FWS > [20]), P = .03. Significant differences were noted between patients with low-flow (LF) vs normal-flow (NF) AS in RV dysfunction prevalence as well as in RV function recovery which is less evident in LF compared with NF patients. CONCLUSIONS: RV dysfunction is high among symptomatic AS patients undergoing TAVI, with variable prevalence depending on the echocardiographic parameter used.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Disfunção Ventricular Direita/cirurgia , Função Ventricular Direita
6.
Eur Heart J ; 41(24): 2244-2247, 2020 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-32572478
10.
Artigo em Inglês | MEDLINE | ID: mdl-39086152

RESUMO

We present the case of a 71-year-old woman with rheumatic valvular disease who underwent mitro-aortic mechanical valve replacement and tricuspid annuloplasty in 2011. She required a dual-chamber pacemaker in 2012 and developed severe tricuspid regurgitation (TR), leading to percutaneous annuloplasty with Cardioband® system in 2021.

11.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38069986

RESUMO

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
12.
Eur Heart J Cardiovasc Imaging ; 25(4): 520-529, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37956101

RESUMO

AIMS: Right ventricular (RV) performance determines clinical management in severe tricuspid regurgitation (TR). Right atrial (RA) function complements RV assessment in TR. This study aimed to design a novel index by speckle-tracking echocardiography (STREI index) integrating RA and RV strain information and to evaluate the clinical utility of combining RV and RA strain for prediction of cardiovascular (CV) outcomes. METHODS AND RESULTS: Consecutive patients with at least (≥) severe TR evaluated in the Heart Valve Clinic (n = 300) were prospectively included. An additional independent TR cohort was included for external validation (n = 50). STREI index was developed with the formula: [2 ∗ RV-free wall longitudinal strain (RV-FWLS)] + reservoir RA strain (RASr). The composite endpoint included hospital admission due to heart failure and all-cause mortality. A total of 176 patients with ≥severe TR were finally included. STREI index identified a higher percentage of patients with RV dysfunction compared with conventional parameters. After a median follow-up of 2.2 years (interquartile range: 12-41 months), a total of 38% reached the composite endpoint. STREI values were predictors of outcomes independently of TR severity and RV dimensions. The combination of prognostic cut-off values of RASr (<10%) and RV-FWLS (>-20%) (STREI stratification) stratified four different groups of risk independently of TR severity, RV dimensions, and clinical status (adj HR per stratum 1.89 (1.4-2.34), P < 0.001). Pre-defined cut-off values achieved similar prognostic performance in the validation cohort (n = 50). CONCLUSION: STREI index is a novel parameter of RV performance that independently predicts CV events. The combination of RA and RV strain stratifies better patients' risk, reflecting a broader effect of TR on right heart chambers.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Humanos , Ecocardiografia/métodos , Prognóstico , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita
13.
JACC Case Rep ; 12: 101774, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37091052

RESUMO

A 78-year-old woman with severe symptomatic secondary atrial tricuspid regurgitation and a long segment of right coronary artery proximity in the posterior tricuspid annulus was treated with transcatheter annuloplasty. Six consecutive anchors were implanted at the level of the atrial wall, crossing the right coronary artery, achieving residual mild regurgitation. (Level of Difficulty: Advanced.).

14.
Rev Esp Cardiol (Engl Ed) ; 76(11): 845-851, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36898521

RESUMO

INTRODUCTION AND OBJECTIVES: Significant tricuspid regurgitation (TR) is associated with increased morbidity and mortality. Clinical evaluation of TR patients is challenging. Our aim was to establish a new clinical classification specific for patients with TR, the 4A classification, and evaluate its prognostic performance. METHODS: We included patients with isolated TR that was at least severe and without previous episodes of heart failure (HF) who were assessed in the heart valve clinic. We registered signs and symptoms of asthenia, ankle swelling, abdominal pain or distention and/or anorexia and followed up the patients every 6 months. The 4A classification ranged from A0 (no A) to A3 (3 or 4 As present). We defined a combined endpoint consisting of hospital admission due to right HF or cardiovascular mortality. RESULTS: We included 135 patients with significant TR between 2016 and 2021 (69% females, mean age 78±7 years). During a median follow-up of 26 [IQR, 10-41] months, 39% (n=53) patients had the combined endpoint: 34% (n=46) were admitted for HF and 5% (n=7) died. At baseline, 94% of the patients were in NYHA I or II, while 24% were in classes A2 or A3. The presence of A2 or A3 conferred a high incidence of events. The change in 4A class remained an independent marker of HF and cardiovascular mortality (adjusted HR per unit of change of 4A class, 1.95 [1.37-2.77]; P<.001). CONCLUSIONS: This study reports a novel clinical classification specifically for patients with TR that is based on signs and symptoms of right HF and has prognostic value for events.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/epidemiologia , Prognóstico , Morbidade , Incidência , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/complicações , Resultado do Tratamento
15.
J Am Soc Echocardiogr ; 36(6): 615-623, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36828258

RESUMO

BACKGROUND: Right ventricular (RV) systolic function is an established marker of outcomes in patients with severe tricuspid regurgitation (TR). Timely detection of RV dysfunction using conventional two-dimensional echocardiography is challenging. RV strain has emerged as an accurate and sensitive tool for the evaluation of RV function, with the capability to detect subclinical RV dysfunction. The aim of this study was to evaluate the prognostic value of RV strain parameters in early stages of severe TR. METHODS: Consecutive patients with at least severe TR (severe, massive, or torrential) and the absence of a formal indication for tricuspid valve intervention in secondary TR evaluated in the Heart Valve Clinic were prospectively included. RV systolic function was measured using conventional echocardiographic indices (RV fractional area change, tricuspid annular plane systolic excursion, and Doppler tissue imaging S wave [S']) and speckle-tracking echocardiography-derived automatic peak global longitudinal strain and free wall longitudinal strain (FWLS) using an automated two-dimensional strain analytic software. A combined end point of hospital admission due to heart failure or all-cause mortality was defined. RESULTS: A total of 266 patients were enrolled in the study, and 151 were ultimately included. Strain parameters detected a higher percentage of abnormal RV values compared with conventional indices. During a median follow-up period of 26 months (interquartile range, 13-42 months), 35% of the patients reached the combined end point. Cumulative event-free survival was significantly worse in patients with impaired RV global longitudinal strain and RV FWLS. Conventional indices of RV systolic function were not associated with outcomes (P > .05 for all). On multivariate analysis, RV FWLS was independently associated with mortality and heart failure (adjusted hazard ratio for abnormal RV FWLS, 5.90; 95% CI, 3.17-10.99; P < .001). CONCLUSION: In early stages of severe TR, RV FWLS is more frequently impaired compared with conventional indices of RV function. Among all parameters, RV FWLS is the strongest predictor of mortality and heart failure, independent of additional prognostic markers.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Humanos , Prognóstico , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Ecocardiografia/efeitos adversos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
16.
EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37565470

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting. AIMS: We aimed to evaluate the safety and feasibility of Myval in NCAR. METHODS: This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed. RESULTS: A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047). CONCLUSIONS: Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
17.
Eur Heart J Cardiovasc Imaging ; 24(8): 1092-1101, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37073554

RESUMO

AIMS: The optimal management of severe tricuspid regurgitation (TR) remains controversial. While right ventricular systolic function is an established prognostic marker of outcomes, the potential role of right atrial (RA) function is unknown. This study aimed to describe RA function by 2D speckle-tracking echocardiography (STE) in at least severe TR and to evaluate its potential association with cardiovascular outcomes. METHODS AND RESULTS: Consecutive patients with at least (≥) severe TR (severe, massive, or torrential TR) evaluated in the Heart Valve Clinic following a comprehensive clinical protocol were included. Consecutive control subjects and patients with permanent isolated atrial fibrillation (AF) were included for comparison (control and AF group, respectively). RA function was measured with 2D-STE and two components of RA function were calculated: reservoir (RASr) and contractile (RASct) strain (AutoStrain, Philips Medical Systems the EPIQ system). A combined endpoint of hospital admission due to heart failure (HF) or all-cause mortality was defined. Patients with ≥ severe TR (n = 140) showed lower RASr compared with controls (n = 20) and with the AF group (n = 20) (P < 0.001). Atrial TR showed lower RASr compared with other aetiologies of TR (P < 0.001). After a median follow-up of 2.2 years (IQR: 12-41 months), RASr remained an independent predictor of mortality and HF. A cut-off value of RASr of <9.4% held the best accuracy to predict outcomes. CONCLUSION: RA function by 2D-STE independently predicts mortality and HF hospitalizations in patients with ≥ severe TR.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Prognóstico , Função do Átrio Direito , Ecocardiografia , Estudos Retrospectivos
18.
Rev Port Cardiol ; 31(5): 363-71, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22482474

RESUMO

BACKGROUND: Percutaneous septal ablation by alcohol-induced septal branch occlusion was introduced as a new treatment option in symptomatic patients with hypertrophic obstructive cardiomyopathy (HOCM). Our aim was to evaluate procedural and long-term clinical and echocardiographic outcomes in patients with HOCM treated by alcohol septal ablation (ASA) at our center. METHODS: This single-center retrospective study included 14 consecutive HOCM patients undergoing percutaneous ASA (66.4 +/- 12.1 years, 71.4% female). At baseline all patients presented persistent symptoms despite optimized medical treatment, left ventricular outflow tract (LVOT) obstruction with a peak gradient > 50 mmHg, systolic anterior motion of the mitral valve, and ventricular septal thickness > or = 15 mm. ASA was considered successful when the LVOT pressure gradient fell to less than 50% of baseline value. All patients had echocardiographic evaluation at baseline, intraprocedure and at follow-up, and a long-term clinical follow-up (25 +/- 38 months) with evaluation of functional class and occurrence of symptoms or cardiovascular events. RESULTS: Percutaneous ASA achieved a 71.4% acute and 85.7% long-term success rate. Peak LVOT gradient decreased from 104 +/- 40 mmHg at baseline to 58 +/- 30 mmHg intraprocedure (p = 0.03) and 35 +/- 26 mmHg at follow-up (p = 0.001); total gradient decrease was 75 +/- 43 mmHg. Ventricular septal thickness and mitral regurgitation also presented significant decreases during follow-up (from 24 +/- 5 mm to 18 +/- 4 mm, p = 0.02, and from grade 2.4 +/- 0.6 to 1.4 +/- 0.5, p < 0.001, respectively). A tendency for long-term improvement in NYHA functional class (from 2.6 +/- 1.1 to 1.8 +/- 1.4, p = 0.09) was observed. Procedural complications occurred in 6.7% of patients; two deaths and one transient ischemic attack occurred in-hospital, but no long-term clinical events were recorded. CONCLUSIONS: Percutaneous ASA is an effective treatment for symptomatic patients with HOCM, obtaining a marked decrease in LVOT pressure gradient and symptomatic improvement. Despite the occurrence of a significant number of procedural complications, the favorable long-term outcomes underline the potential of ASA as a percutaneous alternative to surgical myectomy.


Assuntos
Técnicas de Ablação , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Etanol , Idoso , Etanol/administração & dosagem , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
19.
Rev Port Cardiol ; 31(2): 143-9, 2012 Feb.
Artigo em Português | MEDLINE | ID: mdl-22240099

RESUMO

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is an alternative to surgical aortic valve replacement in patients with severe aortic stenosis (AS) and unacceptably high surgical risk. METHODS: We present our first two years' experience with TAVI. A total of 76 AS patients were evaluated for TAVI and 23 of them underwent a TAVI procedure. These patients had a mean EuroSCORE of 22.4% and a mean age of 81.5 years, and were prospectively followed for a mean of 12.9 ± 11 months. RESULTS: The percutaneous aortic valve was successfully implanted in 100% of the patients. Mortality at 30 days was 4%. The most common complications were access site-related bleeding and transfusion (22%), followed by new permanent pacemaker implantation (9%). After a mean follow-up of 12.9 months, survival was 87%. In a maximum follow-up of 30 months there were no cases of prosthesis dysfunction or cardiovascular death. CONCLUSIONS: Two years after the introduction of a TAVI program in our center, the procedure has established itself as a safe and effective alternative for patients with severe AS and unacceptably high surgical risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco
20.
Eur J Heart Fail ; 24(3): 581-588, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34693613

RESUMO

AIMS: Despite aortic stenosis (AS) relief, patients undergoing transcatheter aortic valve implantation (TAVI) are at increased risk of developing heart failure (HF) within first months of intervention. Sodium-glucose co-transporter 2 (SGLT-2) inhibitors have been shown to reduce the risk of HF hospitalization in individuals with diabetes mellitus, reduced left ventricular ejection fraction and chronic kidney disease. However, the effect of SGLT-2 inhibitors on outcomes after TAVI is unknown. The Dapagliflozin after Transcatheter Aortic Valve Implantation (DapaTAVI) trial is designed to assess the clinical benefit and safety of the SGLT-2 inhibitor dapagliflozin in patients undergoing TAVI. METHODS: DapaTAVI is an independent pragmatic, controlled, prospective, randomized, open-label blinded endpoint, multicentre trial conducted in Spain, evaluating the effect of dapagliflozin 10 mg/day on the risk of death and worsening HF in patients with severe AS undergoing TAVI. Candidate patients should have prior history of HF admission plus ≥1 of the following criteria: (i) diabetes mellitus, (ii) left ventricular ejection fraction ≤40%, or (iii) estimated glomerular filtration rate between 25 and 75 ml/min/1.73 m2 . A total of 1020 patients will be randomized (1:1) to dapagliflozin vs. no dapagliflozin. Key secondary outcomes include: (i) incidence rate of individual components of the primary outcome; (ii) cardiovascular mortality; (iii) the composite of HF hospitalization or cardiovascular death; and (iv) total number of HF rehospitalizations. CONCLUSION: DapaTAVI will determine the efficacy and safety of dapagliflozin in a broad spectrum of frail patients after AS relief by TAVI.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Compostos Benzidrílicos , Glucosídeos , Humanos , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA