Resultados 1 - 20 de 51
Filtrar
1.
Catheter Cardiovasc Interv ; 102(6): 1034-1039, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855145

RESUMO

BACKGROUND: Most randomized studies testing the effectiveness of IVBT were limited to vessels less than 4 mm diameter. In fact, it is now common to treat vessels larger than 4 mm. Accordingly, the authors instituted a prescription dose increase to 34 Gy at 2 mm from source center for vessels greater than 4.0 mm. The increase in prescription dose to 34 Gy at 2 mm from center is substantial, being 50% higher than the conventional maximum of 23 Gy. AIM: To take a close look at group of patients treated to 34 Gy, and for whom follow-up angiograms are available. METHODS: Ten patients treated for ISR with a prescription dose of 34 Gy and for whom follow-up angiograms were available were studied. Beta-radiation brachytherapy was performed with a Novoste Beta-Cath System using a strontium-90 (beta) source (Best Vascular, Springfield, VA). Source lengths of 40 or 60 mm were used. A dose of 34 Gy was prescribed at 2 mm from the source center. RESULTS: Patients were re-catheterized from 2 to 21 months (median: 16 months) following IVBT, all for symptoms suggested of restenosis. All patients had some degree of ISR of the target vessel, but no IVBT-treated vascular segment showed angiographic signs of degeneration, dissection or aneurysm. CONCLUSION: The authors' clinical impression, along with detailed review of the 10 cases, suggest that using a 34 Gy prescription dose at 2 mm from source center does not result in increased toxicity.


Assuntos
Braquiterapia , Reestenose Coronária , Humanos , Braquiterapia/efeitos adversos , Resultado do Tratamento , Cateterismo , Procedimentos Cirúrgicos Vasculares , Stents
2.
J Magn Reson Imaging ; 47(5): 1388-1396, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29044908

RESUMO

BACKGROUND: Robust approaches to quantify tumor heterogeneity are needed to provide early decision support for precise individualized therapy. PURPOSE: To conduct a technical exploration of longitudinal changes in tumor heterogeneity patterns on dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), diffusion-weighted imaging (DWI) and FDG positron emission tomography / computed tomography (PET/CT), and their association to radiation therapy (RT) response in cervical cancer. STUDY TYPE: Prospective observational study with longitudinal MRI and PET/CT pre-RT, early-RT (2 weeks), and mid-RT (5 weeks). POPULATION: Twenty-one FIGO IB2 -IVA cervical cancer patients receiving definitive external beam RT and brachytherapy. FIELD STRENGTH/SEQUENCE: 1.5T, precontrast axial T1 -weighted, axial and sagittal T2 -weighted, sagittal DWI (multi-b values), sagittal DCE MRI (<10 sec temporal resolution), postcontrast axial T1 -weighted. ASSESSMENT: Response assessment 1 month after completion of treatment by a board-certified radiation oncologist from manually delineated tumor volume changes. STATISTICAL TESTS: Intensity histogram (IH) quantiles (DCE SI10% and DWI ADC10% , FDG-PET SUVmax ) and distribution moments (mean, variance, skewness, kurtosis) were extracted. Differences in IH features between timepoints and modalities were evaluated by Skillings-Mack tests with Holm's correction. Area under receiver-operating characteristic curve (AUC) and Mann-Whitney testing was performed to discriminate treatment response using IH features. RESULTS: Tumor IH means and quantiles varied significantly during RT (SUVmean : ↓28-47%, SUVmax : ↓30-59%, SImean : ↑8-30%, SI10% : ↑8-19%, ADCmean : ↑16%, P < 0.02 for each). Among IH heterogeneity features, FDG-PET SUVCoV (↓16-30%, P = 0.011) and DW-MRI ADCskewness decreased (P = 0.001). FDG-PET SUVCoV was higher than DCE-MRI SICoV and DW-MRI ADCCoV at baseline (P < 0.001) and 2 weeks (P = 0.010). FDG-PET SUVkurtosis was lower than DCE-MRI SIkurtosis and DW-MRI ADCkurtosis at baseline (P = 0.001). Some IH features appeared to associate with favorable tumor response, including large early RT changes in DW-MRI ADCskewness (AUC = 0.86). DATA CONCLUSION: Preliminary findings show tumor heterogeneity was variable between patients, modalities, and timepoints. Radiomic assessment of changing tumor heterogeneity has the potential to personalize treatment and power outcome prediction. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1388-1396.


Assuntos
Braquiterapia/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos , Resultado do Tratamento , Carga Tumoral
3.
J Appl Clin Med Phys ; 17(2): 249-257, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074488

RESUMO

Monthly QA is recommended to verify the constancy of high-energy electron beams generated for clinical use by linear accelerators. The tolerances are defined as 2%/2 mm in beam penetration according to AAPM task group report 142. The practical implementation is typically achieved by measuring the ratio of readings at two different depths, preferably near the depth of maximum dose and at the depth corresponding to half the dose maximum. Based on beam commissioning data, we show that the relationship between the ranges of energy ratios for different electron energies is highly nonlinear. We provide a formalism that translates measurement deviations in the reference ratios into change in beam penetration for electron energies for six Elekta (6-18 MeV) and eight Varian (6-22 MeV) electron beams. Experimental checks were conducted for each Elekta energy to compare calculated values with measurements, and it was shown that they are in agreement. For example, for a 6 MeV beam a deviation in the measured ionization ratio of ± 15% might still be acceptable (i.e., be within ± 2 mm), whereas for an 18 MeV beam the corresponding tolerance might be ± 6%. These values strongly depend on the initial ratio chosen. In summary, the relationship between differences of the ionization ratio and the corresponding beam energy are derived. The findings can be translated into acceptable tolerance values for monthly QA of electron beam energies.


Assuntos
Elétrons , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia/instrumentação , Radioterapia/métodos , Humanos , Aceleradores de Partículas/instrumentação , Controle de Qualidade , Dosagem Radioterapêutica
4.
J Appl Clin Med Phys ; 15(3): 4763, 2014 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-24892354

RESUMO

There is a clear need for established standards for medical physics residency training. The complexity of techniques in imaging, nuclear medicine, and radiation oncology continues to increase with each passing year. It is therefore imperative that training requirements and competencies are routinely reviewed and updated to reflect the changing environment in hospitals and clinics across the country. In 2010, the AAPM Work Group on Periodic Review of Medical Physics Residency Training was formed and charged with updating AAPM Report Number 90. This work group includes AAPM members with extensive experience in clinical, professional, and educational aspects of medical physics. The resulting report, AAPM Report Number 249, concentrates on the clinical and professional knowledge needed to function independently as a practicing medical physicist in the areas of radiation oncology, imaging, and nuclear medicine, and constitutes a revision to AAPM Report Number 90. This manuscript presents an executive summary of AAPM Report Number 249.


Assuntos
Guias como Assunto , Física Médica/educação , Física Médica/normas , Internato e Residência/normas , Medicina Nuclear/educação , Radioterapia (Especialidade)/educação , Radiologia/educação , Currículo/normas , Medicina Nuclear/normas , Radioterapia (Especialidade)/normas , Radiologia/normas , Estados Unidos
5.
Cardiovasc Revasc Med ; 59: 29-34, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37684192

RESUMO

PURPOSE: To evaluate coronary artery integrity after very high radiation doses from intravascular brachytherapy (IVBT) in the setting of source asymmetry. METHODS: Ten patients treated for right coronary artery (RCA) in-stent restenosis (ISR) between 2017 and 2021 and for whom follow-up angiograms were available were identified from departmental records. Procedural angiograms, taken to document source position, were used to estimate vascular wall doses. The 2.5 mm proximal source marker was used to estimate the distance from source center to the media and adventitia. Distances were converted to dose (Gy) using the manufacturers' dose fall-off table, measured in water. Follow-up films were scrutinized for any sign of late vascular damage. RESULTS: The average minimal distance from catheter center to the adjacent media and the adventitia was 0.9 mm (±0.2) mm and 1.4 mm (±0.2), respectively. The average maximum media and adventitial doses adjacent to the source were 75 Gy (±26) and 39 Gy (±14), respectively. Follow-up angiograms were available from 0.6 years to 3.9 years following IVBT (median: 1.6 years). No IVBT-treated vascular segment showed signs of degeneration, dissection or aneurysm. CONCLUSION: IVBT vascular wall doses are frequently far higher than prescribed. The lack of complications in this unselected group of patients gives a modicum of reassurance that raising the prescription dose is unlikely to lead to a sudden appearance of complications.


Assuntos
Braquiterapia , Reestenose Coronária , Humanos , Braquiterapia/efeitos adversos , Reestenose Coronária/etiologia , Coração , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Stents/efeitos adversos
6.
Adv Radiat Oncol ; 9(3): 101425, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38379895

RESUMO

Purpose: Animal studies with ultrahigh dose-rate radiation therapy (FLASH, >40 Gy/s) preferentially spare normal tissues without sacrificing antitumor efficacy compared with conventional dose-rate radiation therapy (CONV). At the University of Washington, we developed a cyclotron-generated preclinical scattered proton beam with FLASH dose rates. We present the technical details of our FLASH radiation system and preliminary biologic results from whole pelvis radiation. Methods and Materials: A Scanditronix MC50 compact cyclotron beamline has been modified to produce a 48.7 MeV proton beam at dose rates between 0.1 and 150 Gy/s. The system produces a 6 cm diameter scattered proton beam (flat to ± 3%) at the target location. Female C57BL/6 mice 5 to 6 weeks old were used for all experiments. To study normal tissue effects in the distal colon, mice were irradiated using the entrance region of the proton beam to the whole pelvis, 18.5 Gy at different dose rates: control, CONV (0.6-1 Gy/s) and FLASH (50-80 Gy/s). Survival was monitored daily and EdU (5-ethynyl-2´-deoxyuridine) staining was performed at 24- and 96-hours postradiation. Cleaved caspase-3 staining was performed 24-hours postradiation. To study tumor control, allograft B16F10 tumors were implanted in the right flank and received 18 Gy CONV or FLASH proton radiation. Tumor growth and survival were monitored. Results: After 18.5 Gy whole pelvis radiation, survival was 100% in the control group, 0% in the CONV group, and 44% in the FLASH group (P < .01). EdU staining showed cell proliferation was significantly higher in the FLASH versus CONV group at both 24-hours and 96-hours postradiation in the distal colon, although both radiation groups showed decreased proliferation compared with controls (P < .05). Lower cleaved caspase-3 staining was seen in the FLASH versus conventional group postradiation (P < .05). Comparable flank tumor control was observed in the CONV and FLASH groups. Conclusions: We present our preclinical FLASH proton radiation system and biologic results showing improved survival after whole pelvis radiation, with equivalent tumor control.

7.
J Appl Clin Med Phys ; 14(6): 4305, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24257274

RESUMO

We evaluate a photon convolution-superposition algorithm used to model a fast neutron therapy beam in a commercial treatment planning system (TPS). The neutron beam modeled was the Clinical Neutron Therapy System (CNTS) fast neutron beam produced by 50 MeV protons on a Be target at our facility, and we implemented the Pinnacle3 dose calculation model for computing neutron doses. Measured neutron data were acquired by an IC30 ion chamber flowing 5 cc/min of tissue equivalent gas. Output factors and profile scans for open and wedged fields were measured according to the Pinnacle physics reference guide recommendations for photon beams in a Wellhofer water tank scanning system. Following the construction of a neutron beam model, computed doses were then generated using 100 monitor units (MUs) beams incident on a water-equivalent phantom for open and wedged square fields, as well as multileaf collimator (MLC)-shaped irregular fields. We compared Pinnacle dose profiles, central axis doses, and off-axis doses (in irregular fields) with 1) doses computed using the Prism treatment planning system, and 2) doses measured in a water phantom and having matching geometry to the computation setup. We found that the Pinnacle photon model may be used to model most of the important dosimetric features of the CNTS fast neutron beam. Pinnacle-calculated dose points among open and wedged square fields exhibit dose differences within 3.9 cGy of both Prism and measured doses along the central axis, and within 5 cGy difference of measurement in the penumbra region. Pinnacle dose point calculations using irregular treatment type fields showed a dose difference up to 9 cGy from measured dose points, although most points of comparison were below 5 cGy. Comparisons of dose points that were chosen from cases planned in both Pinnacle and Prism show an average dose difference less than 0.6%, except in certain fields which incorporate both wedges and heavy blocking of the central axis. All clinical cases planned in both Prism and Pinnacle were found to be comparable in terms of dose-volume histograms and spatial dose distribution following review by the treating clinicians. Variations were considered minor and within clinically acceptable limits by the treating clinicians. The Pinnacle TPS has sufficient computational modeling ability to adequately produce a viable neutron model for clinical use in treatment planning.


Assuntos
Algoritmos , Nêutrons Rápidos/uso terapêutico , Neoplasias/radioterapia , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Simulação por Computador , Humanos , Modelos Teóricos , Método de Monte Carlo , Aceleradores de Partículas , Dosagem Radioterapêutica
8.
J Appl Clin Med Phys ; 14(1): 4159, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23318397

RESUMO

The American Association of Physicists in Medicine (AAPM) sponsors two summer undergraduate research programs to attract top performing undergraduate students into graduate studies in medical physics: the Summer Undergraduate Fellowship Program (SUFP) and the Minority Undergraduate Summer Experience (MUSE). Undergraduate research experience (URE) is an effective tool to encourage students to pursue graduate degrees. The SUFP and MUSE are the only medical physics URE programs. From 2001 to 2012, 148 fellowships have been awarded and a total of $608,000 has been dispersed to fellows. This paper reports on the history, participation, and status of the programs. A review of surveys of past fellows is presented. Overall, the fellows and mentors are very satisfied with the program. The efficacy of the programs is assessed by four metrics: entry into a medical physics graduate program, board certification, publications, and AAPM involvement. Sixty-five percent of past fellow respondents decided to pursue a graduate degree in medical physics as a result of their participation in the program. Seventy percent of respondents are currently involved in some educational or professional aspect of medical physics. Suggestions for future enhancements to better track and maintain contact with past fellows, expand funding sources, and potentially combine the programs are presented.


Assuntos
Educação de Graduação em Medicina/economia , Educação de Graduação em Medicina/estatística & dados numéricos , Bolsas de Estudo/economia , Física Médica/economia , Física Médica/educação , Bolsas de Estudo/estatística & dados numéricos , Física Médica/estatística & dados numéricos , Estados Unidos
9.
Phys Med Biol ; 68(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37983905

RESUMO

Fast neutron therapy is a high linear energy transfer (LET) radiation treatment modality offering advantages over low LET radiations. Multileaf collimator technology reduces normal-tissue dose (toxicity) and makes neutron therapy more comparable to MV x-ray treatments. Published clinical-trial and other experiences with fast neutron therapy are reported. Early comparative studies failed to consider differences in target-dose spatial conformality between x-ray and neutron treatments, which is especially important for organs-at-risk close to tumor targets. Treatments planning systems (TPS) for high-energy neutrons lag behind TPS tools for MV x-rays, creating challenges for comparative studies of clinical outcomes. A previously published Monte Carlo model of the University of Washington (UW) Clinical Neutron Therapy System (CNTS) is refined and integrated with the RayStation TPS as an external dose planning/verification tool. The collapsed cone (CC) dose calculations in the TPS are based on measured dose profiles and output factors in water, with the absolute dose determined using a tissue-equivalent ionization chamber. For comparison, independent (external) Monte Carlo simulation computes dose on a voxel-by-voxel basis using an atlas that maps Hounsfield Unit (HU) numbers to elemental composition and density. Although the CC algorithm in the TPS accurately computes neutron dose to water compared to Monte Carlo calculations, calculated dose to water differs from bone or tissue depending largely on hydrogen content. Therefore, the elemental composition of tissue and bone, rather than the material or electron density, affects fast neutron dose. While the CC algorithm suffices for reproducible patient dosimetry in fast neutron therapy, adopting methods that consider tissue heterogeneity would enhance patient-specific neutron dose accuracy relative to national standards for other types of ionizing radiation. Corrections for tissue composition have a significant impact on absolute dose and the relative biological effectiveness (RBE) of neutron treatments compared to other radiation types (MV x-rays, protons, and carbon ions).


Assuntos
Nêutrons Rápidos , Planejamento da Radioterapia Assistida por Computador , Humanos , Nêutrons Rápidos/uso terapêutico , Dosagem Radioterapêutica , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria/métodos , Nêutrons , Água
10.
Phys Med Biol ; 65(16): 165009, 2020 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-32512540

RESUMO

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) has been used to treat over 3300 patients. Treatment planning for these patients is currently performed using an MV x-ray model in Pinnacle® adapted to fit measurements of fast neutron output factors, wedge factors, depth-dose and lateral profiles. While this model has provided an adequate representation of the CNTS for 3D conformal treatment planning, later versions of Pinnacle did not allow for isocentric gantry rotation machines with a source-to-axis distance of 150 cm. This restriction limited the neutron model to version 9.0 while the photon and electron treatment planning at the UW had moved on to newer versions. Also, intensity modulated neutron therapy (IMNT) is underdevelopment at the UW, and the Pinnacle neutron model developed cannot be used for inverse treatment planning. We have used the MCNP6 Monte Carlo code system to develop Collapsed Cone (CC) and Singular Value Decomposition (SVD) neutron scattering kernels suitable for integration into the RayStation treatment planning system. Kernels were generated for monoenergetic neutrons with energies ranging from 1 keV to 51 MeV, i.e. the energy range most relevant to the CNTS. Percent depth dose (PDD) profiles computed in RayStation for the CC and SVD kernels are in excellent agreement with each other for depths beyond the beam's dose build-up region (depths greater than about 1.7 cm) for open 2.8 × 2.8 cm2, 10.3 × 10.3 cm2, and 28.8 × 32.8 cm2 fields. Lateral profiles at several depths, as well as the PDD, calculated using the CC kernels in RayStation for the full CNTS energy spectrum pass a 3%/3 mm gamma test for field sizes of 2.8 × 2.8 cm2, 10.0 × 10.3 cm2, and 28.8 × 32.8 cm2.


Assuntos
Algoritmos , Nêutrons Rápidos/uso terapêutico , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosagem Radioterapêutica , Espalhamento de Radiação
11.
Top Magn Reson Imaging ; 29(3): 135-148, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32568976

RESUMO

The delivery of radiation therapy shares many of the challenges encountered in imaging procedures. As in imaging, such as MRI, organ motion must be reduced to a minimum, often for lengthy time periods, to effectively target the tumor during imaging-guided therapy while reducing radiation dose to nearby normal tissues. For patients, radiation therapy is frequently a stress- and anxiety-provoking medical procedure, evoking fear from negative perceptions about irradiation, confinement from immobilization devices, claustrophobia, unease with equipment, physical discomfort, and overall cancer fear. Such stress can be a profound challenge for cancer patients' emotional coping and tolerance to treatment, and particularly interferes with advanced radiation therapy procedures where active, complex and repetitive high-level cooperation is often required from the patient.In breast cancer, the most common cancer in women worldwide, radiation therapy is an indispensable component of treatment to improve tumor control and outcome in both breast-conserving therapy for early-stage disease and in advanced-stage patients. High technological complexity and high patient cooperation is required to mitigate the known cardiac toxicity and mortality from breast cancer radiation by reducing the unintended radiation dose to the heart from left breast or left chest wall irradiation. To address this, radiation treatment in daily deep inspiration breath hold (DIBH), to create greater distance between the treatment target and the heart, is increasingly practiced. While holding the promise to decrease cardiac toxicity, DIBH procedures often augment patients' baseline stress and anxiety reaction toward radiation treatment. Patients are often overwhelmed by the physical and mental demands of daily DIBH, including the nonintuitive timed and sustained coordination of abdominal thoracic muscles for prolonged breath holding.While technologies, such as DIBH, have advanced to millimeter-precision in treatment delivery and motion tracking, the "human factor" of patients' ability to cooperate and perform has been addressed much less. Both are needed to optimally deliver advanced radiation therapy with minimized normal tissue effects, while alleviating physical and cognitive distress during this challenging phase of breast cancer therapy.This article discusses physical training and psychotherapeutic integrative health approaches, applied to radiation oncology, to leverage and augment the gains enabled by advanced technology-based high-precision radiation treatment in breast cancer. Such combinations of advanced technologies with training and cognitive integrative health interventions hold the promise to provide simple feasible and low-cost means to improve patient experience, emotional outcomes and quality of life, while optimizing patient performance for advanced imaging-guided treatment procedures - paving the way to improve cardiac outcomes in breast cancer survivors.


Assuntos
Neoplasias da Mama/psicologia , Neoplasias da Mama/radioterapia , Cardiotoxicidade/prevenção & controle , Terapia Cognitivo-Comportamental/métodos , Coração/efeitos da radiação , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos , Suspensão da Respiração , Cardiotoxicidade/etiologia , Feminino , Humanos , Qualidade de Vida , Doses de Radiação , Lesões por Radiação/etiologia , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Radiat Res ; 169(4): 447-59, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18363426

RESUMO

A kinetic repair-misrepair-fixation (RMF) model is developed to better link double-strand break (DSB) induction to reproductive cell death. Formulas linking linear-quadratic (LQ) model radiosensitivity parameters to DSB induction and repair explicitly account for the contribution to cell killing of unrejoinable DSBs, misrepaired and fixed DSBs, and exchanges formed through intra- and intertrack DSB interactions. Information from Monte Carlo simulations is used to determine the initial yields and complexity of DSBs formed by low- and high-LET radiations. Our analysis of published survival data for human kidney cells suggests that intratrack DSB interactions are negligible for low-LET radiations but increase rapidly with increasing LET. The analysis suggests that no class of DSB is intrinsically unrejoinable or that DSB reparability is not strictly determined by the number of lesions forming the DSB. For radiations with LET >110 keV/mum, the model predicts that the relative cell killing efficiency, per unit absorbed dose, should continue to increase, whereas data from published experiments indicate a reduced cell killing efficiency. This observation suggests that the Monte Carlo simulation overestimates the DSB yield beyond 110 keV/microm or that other biological phenomena not included in the model, such as proximity effects, are important. For 200-250 kVp X rays ( approximately 1.9 keV/microm), only about 1% of the one-track killing is attributed to intratrack binary misrepair interactions. The analysis indicates that the remaining 99% of the lethal damage is due to other types of one-track damage, including possible unrepairable, misrepaired and fixed damage. Compared to the analysis of the X-ray results, 48% of the one-track lethal damage caused by 5.1 MeV alpha particles (approximately 88 keV/microm) is due to intratrack DSB interactions while the remainder is due to other forms of one-track damage.


Assuntos
Sobrevivência Celular/efeitos da radiação , Quebras de DNA de Cadeia Dupla , Reparo do DNA , Método de Monte Carlo , Humanos , Transferência Linear de Energia , Tolerância a Radiação
13.
Phys Med Biol ; 53(12): 3343-64, 2008 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-18523345

RESUMO

Compensator-based proton therapy of lung cancer using an un-gated treatment while allowing the patient to breathe freely requires a compensator design that ensures tumor coverage throughout respiration. Our investigation had two purposes: one is to investigate the dosimetric impact when a composite compensator correction is applied, or is not, and the other one is to evaluate the significance of using different respiratory phases as the reference computed tomography (CT) for treatment planning dose calculations. A 4D-CT-based phantom study and a real patient treatment planning study were performed. A 3D MIP dataset generated over all phases of the acquired 4D-CT scans was adopted to design the field-specific composite aperture and compensator. In the phantom study, the MIP-based compensator design plan named plan D was compared to the other three plans, in which average intensity projection (AIP) images in conjunction with the composite target volume contour copied from the MIP images were used. Relative electron densities within the target envelope were assigned either to original values from the AIP image dataset (plan A) or to predetermined values, 0.8 (plan B) and 0.9 (plan C). In the patient study, the dosimetric impact of a compensator design based on the MIP images (plan ITV(MIP)) was compared to designs based on end-of-inhale (EOI) (plan ITV(EOI)) and middle-of-exhale (MOE) CT images (plan ITV(MOE)). The dose distributions were recalculated for each phase. Throughout the ten phases, it shows that D(GTV)(min) changed slightly from 86% to 89% (SD = 0.9%) of prescribed dose (PD) in the MIP plan, while varying greatly from 10% to 79% (SD = 26.7%) in plan A, 17% to 73% (SD = 22.5%) in plan B and 53% to 73% (SD = 6.8%) in plan C. The same trend was observed for D(GTV)(mean) and V95 with less amplitude. In the MIP-based plan ITV(MIP), D(GTV)(mean) was almost identically equal to 95% in each phase (SD = 0.5%). The patient study verified that the MIP approach increased the minimum value of D99 of the clinical target volume (CTV) by 58.8% compared to plan ITV(EOI) and 12.9% compared to plan ITV(MOE). Minimum values of D99 were 37.60%, 83.50% and 96.40% for plan ITV(EOI), plan ITV(MOE) and plan ITV(MIP), respectively. Standard deviations of D99 were significantly decreased (SD = 0.5%) in the MIP plan as compared to plan ITV(EOI) (SD = 18.9%) or plan ITV(MOE) (SD = 4.0%). These studies demonstrate that the use of MIP images to design the patient-specific composite compensators provide superior and consistent tumor coverage throughout the entire respiratory cycle whilst maintaining a low average normal lung dose. The additional benefit of the MIP-based design approach is that the dose calculation can be implemented on any single phase as long as it uses the aperture and compensator optimized from the MIP images. This also reduces the requirement for contouring on all breathing phases down to just one.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias Pulmonares/radioterapia , Movimento , Terapia com Prótons , Radiometria/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Respiração , Tomografia Computadorizada por Raios X
14.
Phys Med Biol ; 63(2): 02NT03, 2018 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-29346116

RESUMO

Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Movimento , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Torácicas/diagnóstico por imagem , Neoplasias Torácicas/radioterapia , Humanos , Terapia com Prótons , Dosagem Radioterapêutica , Radioterapia Conformacional , Respiração , Estudos Retrospectivos
15.
Phys Med Biol ; 63(10): 105008, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29637903

RESUMO

The University of Washington (UW) Clinical Neutron Therapy System (CNTS), which generates high linear energy transfer fast neutrons through interactions of 50.5 MeV protons incident on a Be target, has depth-dose characteristics similar to 6 MV x-rays. In contrast to the fixed beam angles and primitive blocking used in early clinical trials of neutron therapy, the CNTS has a gantry with a full 360° of rotation, internal wedges, and a multi-leaf collimator (MLC). Since October of 1984, over 3178 patients have received conformal neutron therapy treatments using the UW CNTS. In this work, the physical and dosimetric characteristics of the CNTS are documented through comparisons of measurements and Monte Carlo simulations. A high resolution computed tomography scan of the model 17 ionization chamber (IC-17) has also been used to improve the accuracy of simulations of the absolute calibration geometry. The response of the IC-17 approximates well the kinetic energy released per unit mass (KERMA) in water for neutrons and photons for energies from a few tens of keV up to about 20 MeV. Above 20 MeV, the simulated model 17 ion chamber response is 20%-30% higher than the neutron KERMA in water. For CNTS neutrons, simulated on- and off-axis output factors in water match measured values within ~2% ± 2% for rectangular and irregularly shaped field with equivalent square areas ranging in a side dimension from 2.8 cm to 30.7 cm. Wedge factors vary by less than 1.9% of the measured dose in water for clinically relevant field sizes. Simulated tissue maximum ratios in water match measured values within 3.3% at depths up to 20 cm. Although the absorbed dose for water and adipose tissue are within 2% at a depth of 1.7 cm, the absorbed dose in muscle and bone can be as much as 12 to 40% lower than the absorbed dose in water. The reported studies are significant from a historical perspective and as additional validation of a new tool for patient quality assurance and as an aid in ongoing efforts to clinically implement advanced treatment techniques, such as intensity modulated neutron therapy, at the UW.


Assuntos
Nêutrons/uso terapêutico , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Humanos , Método de Monte Carlo , Fótons , Dosagem Radioterapêutica
16.
Int J Part Ther ; 5(1): 183-195, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-31773029

RESUMO

BACKGROUND: Merkel cell carcinoma (MCC) is a rare and aggressive cutaneous malignancy. In the advanced setting, MCC is often treated with immune checkpoint inhibitors such as anti-PD-1/PD-L1 antibodies. X-ray radiation therapy (XRT) is commonly used for palliation. There is an unmet need for new treatment options in patients progressing on immunotherapy and XRT. We present 2 patients with progressive MCC who were successfully treated with high linear energy transfer neutron radiation therapy (NRT). CLINICAL OBSERVATIONS: Patient A, an 85-year-old white male with chronic lymphocytic leukemia had progressive MCC with multiple tumors on the face despite prior XRT and ongoing treatment with pembrolizumab. The 5 most symptomatic lesions were treated with a short course of NRT (2 × 3 Gy) while continuing pembrolizumab. All irradiated facial lesions demonstrated a complete response 2 weeks after NRT. Remarkably, an additional 4 lesions located outside the NRT fields also completely resolved. Patient B, a 78-year-old white male with no immunosuppressive condition had recurrent MCC in the scalp and bilateral cervical nodes. The painful, ulcerative tumors on his scalp were progressing despite multiple courses of XRT and multiple immunotherapy regimens, including pembrolizumab. He was treated with NRT (16-18 Gy) to the scalp and had a complete response with successful palliation. While his disease subsequently progressed outside the NRT fields, the response to NRT bridged him to receive further investigational immunotherapies, and he remains disease free 3 years later. CONCLUSION: Short courses of high linear energy transfer particle therapy deserve consideration as a promising modality for local tumor control in XRT refractory tumors. The out-of-field response suggests that NRT has potential for synergizing with immunotherapy. While more data are required to identify optimal NRT parameters, the NRT dose that potentiates an antitumor immune response appears to be well below organ-at-risk tolerance.

17.
Australas Phys Eng Sci Med ; 30(4): 331-6, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18274075

RESUMO

A general methodology for addressing relative motion of targets and normal tissue for dynamic-MLC (DMLC) tracking is discussed. The basic idea is to exploit the extra degrees of freedom that tissue motion introduces into DMLC delivery. This principle is illustrated through the use of a simple example which uses a moving rigid target whose projection in the beam's eye view intersects a stationary critical organ. DMLC delivery which tracks the target motion is simulated, and it is shown that the choice of leaf motion and the time of the onset of delivery can have a large impact on the exposure of the critical organ. Depending on the choice of these parameters, the integral MU delivered to the critical organ ranged from -75% to +250% relative to the delivery planned for static geometry. These results indicate that deliveries using DMLC tracking should accommodate any normal tissue that is moving with respect to the tumor. This should be done to (1) avoid deliveries which result in large over-exposures of critical organs, and (2) to seek out deliveries that result in critical organ exposures that are lower than what is possible with any static geometry (4D therapy).


Assuntos
Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Fenômenos Biofísicos , Biofísica , Humanos , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos
18.
Australas Phys Eng Sci Med ; 30(4): 326-30, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18274074

RESUMO

A study of neutron production from a novel active scanning proton beam delivery system at the Midwest Proton Radiotherapy Institute (MPRI) has been performed. The neutron dose equivalent was determined using a neutron rem (roentgen equivalent in man) detector which has an upper energy limit of 10 MeV. Measurement were taken at 0, 45, and 90 degrees from the proton beam central axis and for various proton beam energies (127-208 MeV) and scanned field sizes (25-144 cm2). The maximum neutron dose observed was 0.43 mSv / (proton treatment Gy) at 90 degrees from the beam axis for a beam energy of 208.4 MeV and a scanned field size of 144 cm2. It is still possible to further mitigate this secondary neutron dose during treatment by optimizing parameters within the treatment nozzle and using shielding.


Assuntos
Nêutrons/efeitos adversos , Terapia com Prótons , Fenômenos Biofísicos , Biofísica , Dosagem Radioterapêutica , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/estatística & dados numéricos , Espalhamento de Radiação , Pele/efeitos da radiação
19.
Australas Phys Eng Sci Med ; 30(4): 341-4, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18274077

RESUMO

Characterizing respiratory-induced tumour motion is an important step in the effective image-guided radiation treatment of moving tumours, especially for tumours in the lung and lower abdomen. This study characterized tumour motion based on a piecewise linear model representing tumour motion at defined stages of the breathing cycle. Lung tumour locations were categorized based on broncho-pulmonary segments. Association rules between tumour motion characteristics and their locations in the lung were discovered and parameterized through statistical analysis. Results show there is a correlation between tumour motion characteristics and tumour location in the lungs. Generally, tumours with small motion (amplitude < 10 mm) are observed most frequently in the apex region of lung or when attached to a fixed structure, such as the chest wall or aorta. Tumours with relatively large motion (amplitude > 20 mm) are located close to the diaphragm or mid-level periphery of the lungs close to the chest wall.


Assuntos
Neoplasias Pulmonares/radioterapia , Humanos , Modelos Lineares , Neoplasias Pulmonares/fisiopatologia , Modelos Biológicos , Movimento , Planejamento da Radioterapia Assistida por Computador , Mecânica Respiratória , Estudos Retrospectivos
20.
Phys Med Biol ; 62(4): 1501-1517, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28121630

RESUMO

During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new iterative morphing algorithm to predict the real-time 3D tumor volume based on time-resolved computed tomography (4DCT) acquired before treatment. An offline iterative learning process has been designed to derive a target volumetric deformation function from one breathing phase to another. Real-time volumetric prediction is performed to derive the target 3D volume during treatment delivery. The proposed iterative deformable approach for tumor volume morphing and prediction based on 4DCT is innovative because it makes three major contributions: (1) a novel approach to landmark selection on 3D tumor surfaces using a minimum bounding box; (2) an iterative morphing algorithm to generate the 3D tumor volume using mapped landmarks; and (3) an online tumor volume prediction strategy based on previously trained deformation functions utilizing 4DCT. The experimental performance showed that the maximum morphing deviations are 0.27% and 1.25% for original patient data and artificially generated data, which is promising. This newly developed algorithm and implementation will have important applications for treatment planning, dose calculation and treatment validation in cancer radiation treatment.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/radioterapia , Radioterapia Guiada por Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Respiração , Carga Tumoral