1.
Magn Reson Med ; 87(2): 614-628, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34480778

RESUMO

PURPOSE: Point-of-care MRI requires operation outside of Faraday shielded rooms normally used to block image-degrading electromagnetic interference (EMI). To address this, we introduce the EDITER method (External Dynamic InTerference Estimation and Removal), an external sensor-based method to retrospectively remove image artifacts from time-varying external interference sources. THEORY AND METHODS: The method acquires data from multiple EMI detectors (tuned receive coils as well as untuned electrodes placed on the body) simultaneously with the primary MR coil during and between image data acquisition. We calculate impulse response functions dynamically that map the data from the detectors to the time varying artifacts then remove the transformed detected EMI from the MR data. Performance of the EDITER algorithm was assessed in phantom and in vivo imaging experiments in an 80 mT portable brain MRI in a controlled EMI environment and with an open 47.5 mT MRI scanner in an uncontrolled EMI setting. RESULTS: In the controlled setting, the effectiveness of the EDITER technique was demonstrated for specific types of introduced EMI sources with up to a 97% reduction of structured EMI and up to 76% reduction of broadband EMI in phantom experiments. In the uncontrolled EMI experiments, we demonstrate EMI reductions of up to 99% using an electrode and pick-up coil in vivo. We demonstrate up to a nine-fold improvement in image SNR with the method. CONCLUSION: The EDITER technique is a flexible and robust method to improve image quality in portable MRI systems with minimal passive shielding and could reduce the reliance of MRI on shielded rooms and allow for truly portable MRI.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Algoritmos , Imagens de Fantasmas , Estudos Retrospectivos
2.
NMR Biomed ; 35(11): e4793, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35772938

RESUMO

The purpose of the current study was to implement unequal microstrip power splitters for parallel transmission at 7 T that are optimized for size and loss and that can be configured for a wide range of power ratios. The splitters will enable the use of more transmit coils without a corresponding increase in the number of transmit channels or amplifiers to control specific absorption rate, shorten RF pulses, and shim inhomogeneous RF fields. Wilkinson unequal power splitters based on a novel microstrip network design were optimized to minimize their size under 8 cm in length and 9 cm in width, enabling them to be included in coil housing or cascaded in multiple stages. Splitters were designed and constructed for a wide range of output power ratios at 298 MHz. Simulations and bench tests were performed for each ratio, and a methodology was established to adapt the designs to other ratios and frequencies. The designs and code are open source and can be reproduced as is or reconfigured. The single-stage designs achieved good matches and isolations between output ports (worst isolation -15.9 dB, worst match -15.1 dB). A two-stage cascaded (one input to four outputs) power splitter with 1:2.5, 1:10, 1:3, and 1:6 ratio outputs was constructed. The worst isolation between output ports was -19.7 dB in simulation and the worst match of the three ports was -17.8 dB. The measured ratios for one- and two-stage boards were within 10% of the theoretical ratios. The power-handling capability of the smallest trace was approximately 70 W. Power loss for the one- and two-stage boards ranged from 1% to 3% in simulation compared with 5.1% to 7.2% on the bench. It was concluded that Wilkinson unequal microstrip power splitters can be implemented with a small board size (low height) and low loss, and across a wide range of output power ratios. The splitters can be cascaded in multiple stages while maintaining the expected ratios and low loss. This will enable the construction of large fixed transmit array-compression matrices with low loss.


Assuntos
Compressão de Dados , Imageamento por Ressonância Magnética , Amplificadores Eletrônicos , Simulação por Computador , Compressão de Dados/métodos , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
3.
IEEE Trans Med Imaging ; 41(6): 1420-1430, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34990352

RESUMO

Balun or trap circuits are critical components for suppressing common-mode currents flowing on the outer conductors of coaxial cables in RF coil systems for Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS). Common-mode currents affect coils' tuning and matching, induce losses, pick up extra noise from the surrounding environment, lead to undesired cross-talk, and cause safety concerns in animal and human imaging. First proposed for microwave antenna applications, the Lattice balun has been widely used in MRI coils. It has a small footprint and can be easily integrated with coil tuning/matching circuits. However, the Lattice balun is typically a single-tuned circuit and cannot be used for multi-nuclear MRI and MRS with two RF frequencies. This work describes a dual-tuned Lattice balun design that is suitable for multi-nuclear MRI/MRS. It was first analyzed theoretically to derive component values. RF circuit simulations were then performed to validate the theoretical analysis and provide guidance for practical construction. Based on the simulation results, a dual-tuned balun circuit was built for 7T 1H/23Na MRI and bench tested. The fabricated dual-tuned balun exhibits superior performance at the Larmor frequencies of both 1H and 23Na, with less than 0.15 dB insertion loss and better than 17 dB common-mode rejection ratio at both frequencies.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagens de Fantasmas
4.
Nat Biomed Eng ; 5(3): 229-239, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33230306

RESUMO

Access to scanners for magnetic resonance imaging (MRI) is typically limited by cost and by infrastructure requirements. Here, we report the design and testing of a portable prototype scanner for brain MRI that uses a compact and lightweight permanent rare-earth magnet with a built-in readout field gradient. The 122-kg low-field (80 mT) magnet has a Halbach cylinder design that results in a minimal stray field and requires neither cryogenics nor external power. The built-in magnetic field gradient reduces the reliance on high-power gradient drivers, lowering the overall requirements for power and cooling, and reducing acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique that leverages previous characterization of the field patterns. In healthy adult volunteers, the scanner can generate T1-weighted, T2-weighted and proton density-weighted brain images with a spatial resolution of 2.2 × 1.3 × 6.8 mm3. Future versions of the scanner could improve the accessibility of brain MRI at the point of care, particularly for critically ill patients.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Humanos , Campos Magnéticos , Aplicativos Móveis