Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Int J Mol Sci ; 24(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37958698

RESUMO

Antimicrobial resistance is a silent pandemic considered a public health concern worldwide. Strategic therapies are needed to replace antibacterials that are now ineffective. One approach entails the use of well-known antibacterials along with adjuvants that possess non-antibiotic properties but can extend the lifespan and enhance the effectiveness of the treatment, while also improving the suppression of resistance. In this regard, a group of uniform materials based on organic salts (GUMBOS) presents an alternative to this problem allowing the combination of antibacterials with adjuvants. Fluoroquinolones are a family of antibacterials used to treat respiratory and urinary tract infections with broad-spectrum activity. Ciprofloxacin and moxifloxacin-based GUMBOS were synthesized via anion exchange reactions with lithium and sodium salts. Structural characterization, thermal stability and octanol/water partition ratios were evaluated. The antibacterial profiles of most GUMBOS were comparable to their cationic counterparts when tested against Gram-positive S. aureus and Gram-negative E. coli, except for deoxycholate anion, which demonstrated the least effective antibacterial activity. Additionally, some GUMBOS were less cytotoxic to L929 fibroblast cells and non-hemolytic to red blood cells. Therefore, these agents exhibit promise as an alternative approach to combining drugs for treating infections caused by resistant bacteria.


Assuntos
Fluoroquinolonas , Sais , Fluoroquinolonas/farmacologia , Sais/farmacologia , Sais/química , Escherichia coli , Staphylococcus aureus , Antibacterianos/química , Ânions , Testes de Sensibilidade Microbiana
2.
J Enzyme Inhib Med Chem ; 37(1): 1527-1536, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35635138

RESUMO

A novel automated method based on sequential injection analysis (SIA), a non-segmented flow injection technique, was developed to evaluate glutathione S-transferase P1-1 (GST P1-1) activity in the presence of organometallic complexes with putative anticancer activity. The assay is based on the reaction of L-glutathione (GSH) and 1-chloro-2,4-dinitrobenzene (CDNB) in the presence of GST P1-1 to afford the GS-DNB conjugate and the reaction may be monitored by an increase in absorbance at 340 nm. A series of ruthenium, iron, osmium and iridium complexes were evaluated as GST P1-1 inhibitors by evaluating their half-maximal inhibitory concentration (IC50). An iridium compound displays the lowest IC50 value of 6.7 ± 0.7 µM and an iron compound displays the highest IC50 value of 275 ± 9 µM. The SIA method is simple to use, robust, reliable, and efficient and uses fewer reagents than batch methods and each analysis takes only 5 minutes.


Assuntos
Glutationa Transferase , Compostos Organometálicos , Glutationa , Glutationa S-Transferase pi , Irídio , Compostos Organometálicos/farmacologia
3.
Molecules ; 26(1)2021 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-33401768

RESUMO

Human neutrophil elastase (HNE) is used as diagnostic biomarker for inflammation/infection. In this work, 10 ionic liquids (ILs) and 11 ionic liquids active pharmaceutical ingredients (ILs-APIs) were tested to evaluate the inhibition effect on the activity of porcine pancreatic elastase enzyme, frequently employed as a model for HNE. The insertion of ionic liquids in some drugs is useful, as the insertion of ILs with inhibitory capacity will also slow down all processes in which this enzyme is involved. Therefore, a spectrophotometric method was performed to the determination of EC50 values of the compounds tested. EC50 values of 124 ± 4 mM to 289 ± 11 mM were obtained, with the most toxic IL for elastase being tetrabutylammonium acetate and the least toxic 1-butyl-3-methylimidazolium acetate. Moreover, sodium salicylate (raw material) presented the lower and benzethonium bistriflimide the higher EC50 when compared with all the IL-APIs tested. This work provides significant information about the effect of the studied IL and IL-APIs in elastase enzyme activity.


Assuntos
Líquidos Iônicos/química , Líquidos Iônicos/farmacologia , Elastase Pancreática/antagonistas & inibidores , Inibidores de Serina Proteinase/química , Inibidores de Serina Proteinase/farmacologia , Compostos de Anilina/metabolismo , Animais , Imidazóis/química , Imidazóis/farmacologia , Líquidos Iônicos/toxicidade , Elastase Pancreática/metabolismo , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacologia , Salicilato de Sódio/farmacologia , Relação Estrutura-Atividade , Suínos
4.
Analyst ; 145(7): 2701-2708, 2020 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-32072997

RESUMO

In this work, two solid-phases based on imidazolium-based ionic liquids were obtained and characterized for solid-phase extraction of fluoroquinolones. The process of immobilization was performed replacing a toxic reagent by UV-irradiation to get a harmless process. The obtained solid-phases were characterized by nuclear magnetic resonance spectroscopy and elemental analysis. Each solid-phase was packed in a cartridge and was used in solid-phase extraction processes for norfloxacin and ciprofloxacin, after the optimization of some parameters such as the elution solvent, the eluent volume and, the sample volume to be used during the loading step. The developed solid-phases with immobilized ionic liquids were successfully implemented for the studied compounds and indicate high probabilities to be useful in solid-phase extractions of other fluoroquinolones.

5.
Analyst ; 143(10): 2426-2434, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29713696

RESUMO

An automatic assay was developed that is intended to be a generic tool for evaluation of a horseradish peroxidase activity in different ionic liquids (ILs). Ionic liquids with different characteristics were used and their effects on the enzymatic reaction, were compared with those obtained with conventional organic solvents. In addition, ILs were tested as solvents for the enzyme substrate (bisphenol A (BPA)). ILs were shown to be a good alternative to conventional organic solvents from either the effect on enzymatic activity or the solubilization of bisphenol. Since bisphenol A is an endocrine disruptor frequently used in plastic industries, it was also applied the developed enzymatic methodology for quantification of this compound in real beverage samples. To increase the sensitivity (already increased by the use of an IL) and the selectivity of the methodology, a sample pre-treatment using a molecular recognition solid phase extraction was applied. Finally, the methodology presented detection and quantification limits of 7.73 × 10-4 and 1.29 × 10-3 mmol L-1 and a linear range up to 1.00 mmol L-1, allowing accurate and reliable quantifications of bisphenol in beer and cola drink samples. This work confirmed the potential of a sequential injection analysis (SIA) system as a simple, versatile, robust, and rapid analytical tool for automating enzymatic assays in ILs medium and, at the same time, showed it to be a relevant automatic alternative for routine determinations of bisphenol A in food samples.


Assuntos
Compostos Benzidrílicos/análise , Biocatálise , Análise de Alimentos/métodos , Líquidos Iônicos/química , Fenóis/análise , Disruptores Endócrinos , Extração em Fase Sólida , Solventes
6.
Ecotoxicol Environ Saf ; 152: 55-60, 2018 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-29407782

RESUMO

Antipsychotic (AP) drugs are becoming accumulated in terrestrial and aqueous resources due to their actual consumption. Thus, the search of methods for assessing the contamination load of these drugs is mandatory. The COD is a key parameter used for monitoring water quality upon the assessment of the effect of polluting agents on the oxygen level. Thus, the present work aims to assess the chemical oxygen demand (COD) levels of several typical and atypical antipsychotic drugs in order to obtain structure-activity relationships. It was implemented the titrimetric method with potassium dichromate as oxidant and a digestion step of 2h, followed by the measurement of remained unreduced dichromate by titration. After that, an automated sequential injection analysis (SIA) method was, also, used aiming to overcome some drawbacks of the titrimetric method. The results obtained showed a relationship between the chemical structures of antipsychotic drugs and their COD values, where the presence of aromatic rings and oxidable groups give higher COD values. It was obtained a good compliance between the results of the reference batch procedure and the SIA system, and the APs were clustered in two groups, with the values ratio between the methodologies, of 2 or 4, in the case of lower or higher COD values, respectively. The SIA methodology is capable of operating as a screening method, in any stage of a synthetic process, being also more environmentally friendly, and cost-effective. Besides, the studies presented open promising perspectives for the improvement of the effectiveness of pharmaceutical removal from the waste effluents, by assessing COD values.


Assuntos
Antipsicóticos/análise , Análise da Demanda Biológica de Oxigênio/métodos , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Antipsicóticos/química , Oxirredução , Oxigênio/análise , Relação Estrutura-Atividade , Titulometria , Eliminação de Resíduos Líquidos , Poluentes Químicos da Água/química , Qualidade da Água
7.
Chemphyschem ; 18(10): 1351-1357, 2017 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-28217924

RESUMO

A novel automated fluorimetric technique was developed for the assessment of the chemical oxygen demand (COD) of ionic liquids (ILs) and combined with a photodegradation step to promote IL degradation. The method was implemented on a sequential injection analysis (SIA) system and is based on the reduction of cerium(IV) in the presence of irradiated ILs. Compounds incorporating the chloride anion were found to exhibit higher COD values and 1-butyl-3-methylimidazolium chloride ([bmim]+ [Cl]- ), 1-butyl-1-methylpyrrolidinium chloride ([bmpyr]+ [Cl]- ), and1-hexyl-3-methylimidazolium chloride ([hmim]+ [Cl]- ) also exhibited considerable photodegradability, whereas the cholinium cation and methanesulfonate and tetrafluoroborate anions showed resistance to photolysis. The developed methodology proved to be a simple, affordable, and robust method, showing good repeatability under the tested conditions (rsd <3.5 %, n=10). Therefore, it is expected that the developed approach can be used as a screening method for the preliminary evaluation of compounds' potential impact in the aquatic field. Additionally, the photolysis step presents an attractive option to promote degradation of ILs prior to their release into wastewater.


Assuntos
Automação , Fluorometria , Líquidos Iônicos/química , Oxigênio/química , Processos Fotoquímicos
8.
Chemphyschem ; 16(9): 1880-8, 2015 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-25908390

RESUMO

Immobilization of quantum dots (QDs) onto solid supports could improve their applicability in the development of sensing platforms and solid-phase reactors by allowing the implementation of reusable surfaces and the execution of repetitive procedures. As the reactivity of QDs relies mostly on their surface chemistry, immobilization could also limit the disruption of solution stability that could prevent stable measurements. Herein, distinct strategies to immobilize QDs onto porous aminated supports, such as physical adsorption and the establishment of chemical linking, were evaluated. This work explores the influence of QD capping and size, concentration, pH, and contact time between the support and the QDs. Maximum QD retention was obtained for physical adsorption assays. Freundlich and Langmuir isotherms were used to analyze the equilibrium data. Gibbs free energy, enthalpy, and entropy were calculated and the stability of immobilized QDs was confirmed.

9.
Biosens Bioelectron ; 251: 116095, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38382268

RESUMO

Chronic wounds (CW) present a significant healthcare challenge due to their prolonged healing time and associated complications. To effectively treat these wounds and prevent further deterioration, monitoring their healing progress is crucial. Traditional wound assessment methods relying on visual inspection and subjective evaluation are prone to inter-observer variability. Biomarkers play a critical role in objectively evaluating wound status and predicting healing outcomes, providing quantitative measures of wound healing progress, inflammation, infection, and tissue regeneration. Recent attention has been devoted to identifying and validating CW biomarkers. Various studies have investigated potential biomarkers, including growth factors, cytokines, proteases, and extracellular matrix components, shedding light on the complex molecular and cellular processes within CW. This knowledge enables a more targeted and personalized approach to wound management. Accurate and sensitive techniques are necessary for detecting CW biomarkers. Thus, this review compares and discusses the use of electrochemical and optical sensors for biomarker determination. The advantages and disadvantages of these sensors are highlighted. Differences in detection capabilities and characteristics such as non-invasiveness, portability, high sensitivity, specificity, simplicity, cost-effectiveness, compatibility with point-of-care applications, and real-time monitoring of wound biomarkers will be pointed out and compared. In summary, this work provides an overview of CW, explores the emerging field of CW biomarkers, and discusses methods for detecting these biomarkers, with a specific focus on optical and electrochemical sensors. The potential of further research and development in this field for advancing wound care and improving patient outcomes will also be noted.


Assuntos
Técnicas Biossensoriais , Humanos , Biomarcadores/análise , Cicatrização , Atenção à Saúde
10.
Dalton Trans ; 53(32): 13503-13514, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39072444

RESUMO

Tris(pyrazolyl)methane (tpm), 2,2,2-tris(pyrazolyl)ethanol (tpmOH) and its esterification derivatives with ibuprofen and flurbiprofen (tpmIBU and tpmFLU) were used as ligands to obtain complexes of the type [Fe(tpmX)2]Cl2 (1-4). The tpmIBU and tpmFLU ligands and corresponding complexes 3 and 4 were characterized by IR and multinuclear NMR spectroscopy, and the structure of tpmIBU was elucidated by single crystal X-ray diffraction. Complexes 1-4 were also assessed for their behaviour in aqueous media (solubility in D2O, octanol/water partition coefficient, stability in physiological-like conditions). The antiproliferative activity of ligands and complexes was determined on A2780, A2780cis and A549 cancer cell lines and the non-cancerous HEK 293T and BJ cell lines. The ligands and complexes were investigated for their ability to inhibit COX-2 (cyclooxygenase) and HNE (4-hydroxynonenal) enzymes. Complexes 3 and 4 exhibited cytotoxicity that may be attributed predominantly to their bioactive fragments, while DNA binding and enhancement of ROS production do not appear to play any significant role.


Assuntos
Anti-Inflamatórios não Esteroides , Antineoplásicos , Complexos de Coordenação , Pirazóis , Humanos , Ligantes , Antineoplásicos/farmacologia , Antineoplásicos/química , Antineoplásicos/síntese química , Complexos de Coordenação/química , Complexos de Coordenação/farmacologia , Complexos de Coordenação/síntese química , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/farmacologia , Anti-Inflamatórios não Esteroides/síntese química , Pirazóis/química , Pirazóis/farmacologia , Pirazóis/síntese química , Proliferação de Células/efeitos dos fármacos , Linhagem Celular Tumoral , Compostos Ferrosos/química , Compostos Ferrosos/farmacologia , Metano/química , Metano/análogos & derivados , Metano/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais , Ciclo-Oxigenase 2/metabolismo , Aldeídos/química , Aldeídos/farmacologia , Espécies Reativas de Oxigênio/metabolismo , Estrutura Molecular , Ibuprofeno/química , Ibuprofeno/farmacologia , Modelos Moleculares
11.
Appl Spectrosc ; 78(8): 806-814, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38747750

RESUMO

Tuning the 8-anilino-1-naphthalenesulfonic acid (ANS) structure usually requires harsh conditions and long reaction times, which can result in low yields. Herein, ANS was modified to form an ANS group of uniform materials based on organic salts (GUMBOS), prepared with simple metathesis reactions and distinct cations, namely tetrabutylammonium (N4444), tetrahexylammonium (N6666), and tetrabutylphosphonium (P4444). These ANS-based GUMBOS were investigated as fluorescent probes for membrane binding studies with four proteins having distinct physicochemical properties. Liposomes of 1,2-dimyristoyl-sn-glycero-3-phosphocholine were employed as membrane models as a result of their ability to mimic the structure and chemical composition of cell membranes. Changes in fluorescence intensity were used to monitor protein binding to liposomes, and adsorption data were fitted to a Freundlich-like isotherm. It was determined that [N4444][ANS] and [P4444][ANS] GUMBOS have enhanced optical properties and lipophilicity as compared to parent ANS. As a result, these two GUMBOS were selected for subsequent protein-membrane binding studies. Both [N4444][ANS] and [P4444][ANS] GUMBOS and parent ANS independently reached membrane saturation within the same concentration range. Furthermore, distinct fluorescence responses were observed upon the addition of proteins to each probe, which demonstrates the impact of properties such as lipophilicity on the binding process. The relative maintenance of binding cooperativity and maximum fluorescence intensity suggests that proteins compete with ANS-based probes for the same membrane binding sites. Finally, this GUMBOS-based approach is simple, rapid, and involves relatively small amounts of reagents, making it attractive for high-throughput purposes. These results presented herein can also provide relevant information for designing GUMBOS with ameliorated properties.


Assuntos
Naftalenossulfonato de Anilina , Lipossomos , Ligação Proteica , Naftalenossulfonato de Anilina/química , Lipossomos/química , Corantes Fluorescentes/química , Espectrometria de Fluorescência/métodos , Materiais Biomiméticos/química , Sais/química , Compostos de Amônio Quaternário/química
12.
Dalton Trans ; 52(33): 11679-11690, 2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37552495

RESUMO

Ruthenium-based complexes have been suggested as promising anticancer drugs exhibiting reduced general toxicity compared to platinum-based drugs. In particular, Ru(η6-arene)(PTA)Cl2 (PTA = 1,3,5-triaza-7-phosphaadamantane), or RAPTA, complexes have demonstrated efficacy against breast cancer by suppressing metastasis, tumorigenicity, and inhibiting the replication of the human tumor suppressor gene BRCA1. However, RAPTA compounds have limited cytotoxicity, and therefore comparatively high doses are required. This study explores the activity of a series of RAPTA-like ruthenium(II) arene compounds against MCF-7 and MDA-MB-231 breast cancer cell lines and [Ru(η6-toluene)(PPh3)2Cl]+ was identified as a promising candidate. Notably, [Ru(η6-toluene)(PPh3)2Cl]Cl was found to be remarkably stable and highly cytotoxic, and selective to breast cancer cells. The minor groove of DNA was identified as a relevant target.


Assuntos
Antineoplásicos , Neoplasias da Mama , Complexos de Coordenação , Compostos Organometálicos , Rutênio , Humanos , Feminino , Compostos Organometálicos/farmacologia , Compostos Organometálicos/metabolismo , Rutênio/farmacologia , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Antineoplásicos/farmacologia , Antineoplásicos/metabolismo , Tolueno , Linhagem Celular Tumoral , Complexos de Coordenação/farmacologia
13.
Biosensors (Basel) ; 13(4)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37185512

RESUMO

The combination of multiple quantum dots (QDs) in a multi-emitter nanoprobe can be envisaged as a promising sensing scheme, as it enables obtaining a collective response of individual emitters towards a given analyte and allows for achieving specific analyte-response profiles. The processing of these profiles using adequate chemometric methods empowers a more sensitive, reliable and selective determination of the target analyte. In this work, we developed a kinetic fluorometric method consisting of a dual CdTe/AgInS2 quantum dots photoluminescence probe for the determination of acetylsalicylic acid (ASA). The fluorometric response was acquired as second-order time-based excitation/emission matrices that were subsequently processed using chemometric methods seeking to assure the second-order advantage. The data obtained in this work are considered second-order data as they have a three-dimensional size, I × J × K (where I represents the samples' number, J the fluorescence emission wavelength while K represents the time). In order to select the most adequate chemometric method regarding the obtained data structure, different chemometric models were tested, namely unfolded partial least squares (U-PLS), N-way partial least squares (N-PLS), multilayer feed-forward neural networks (MLF-NNs) and radial basis function neural networks (RBF-NNs).


Assuntos
Compostos de Cádmio , Pontos Quânticos , Aspirina , Compostos de Cádmio/química , Quimiometria , Telúrio/química
14.
Ecotoxicol Environ Saf ; 80: 97-102, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22417674

RESUMO

An automated high-throughput Vibrio fischeri assay was developed and further applied to the evaluation of ionic liquids (ILs) (eco)toxicity. The assay was based on the reduction of bacterial bioluminescence in the presence of test compounds and the results were presented as EC(50). The assays were performed with eight commercially available ILs with distinct cationic head groups, alkyl side chains and anions. EC(50) values between 6.5 and 691.9 mmol L(-1) were obtained for the tested ILs, being hmim [Cl] the most toxic and bmim [Cl] the less toxic ones, confirming the influence of the different structural elements. Moreover, all the tested ILs exhibited a (eco)toxicity lower than Cu(II), used as a positive control during the optimization and analysis steps. The automated assay assured the precise control of the contact time between V. fischeri and test compound by means of a simple protocol that guaranteed adequate aspiration and handling of the solutions as well as the precise implementation of a computer controlled stop period. Furthermore, a significant reduction of the assay costs was achieved through automation mainly by a drastic reduction of the volume of bacterial suspension and test compound. The methodology was validated by comparison with a microplate assay; it was stated that the results, obtained after a 3min contact time, changed proportionally relatively to Cu(II) in both assays. This confirmed the applicability of the methodology as an (eco)toxicity screening assay, with reduction of time and increase of robustness and repeatability (n=10; rsd<1.1%). It is expected that due to its simplicity and reduced cost the developed assay can be integrated in the early stage of development of new compounds as a rapid screening test.


Assuntos
Poluentes Ambientais/toxicidade , Ensaios de Triagem em Larga Escala/métodos , Líquidos Iônicos/toxicidade , Aliivibrio fischeri , Automação Laboratorial , Bioensaio/métodos , Ecotoxicologia , Poluentes Ambientais/química , Ensaios de Triagem em Larga Escala/instrumentação , Líquidos Iônicos/química
15.
Dalton Trans ; 51(44): 17050-17063, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36314260

RESUMO

In comparison with RuII-arene compounds, the medicinal potential of homologous RuII-tpm compounds [tpm = tris(pyrazolyl)methane] is underexplored. Pyridine, 4-pyridinemethanol and four functionalized pyridines, synthesized from the esterification of 4-pyridinemethanol with bioactive carboxylic acids (i.e., ethacrynic acid, ibuprofen, flurbiprofen and naproxen), react with the precursor [RuCl(κ3-tpm)(PPh3)2]Cl (1) to afford [RuCl(κ3-tpm)(PPh3)(L)]Cl (2-7, L = pyridine ligand), in 78-91% yields. All products were fully characterized by HR-ESI mass spectrometry, IR and multinuclear NMR spectroscopy and the solid-state structures of two of the complexes, i.e. where L = pyridine and 4-pyridinemethanol, were ascertained by single crystal X-ray diffraction. The {Ru-tpm-PPh3} assembly is stable in D2O and in biological medium (DMEM) at 37 °C, with a tendency to slowly dissociate the pyridine ligand. The antiproliferative activity of the complexes was assessed on the cancerous A2780 and A2780cisR cell lines, and the nontumoral HEK 293T cell line; moreover inhibition assays were carried out on the complexes towards COX-2 and GSTP1 enzymes.


Assuntos
Neoplasias Ovarianas , Rutênio , Humanos , Feminino , Rutênio/química , Ligantes , Metano , Linhagem Celular Tumoral
16.
Spectrochim Acta A Mol Biomol Spectrosc ; 267(Pt 2): 120592, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34789406

RESUMO

A sensing platform combining carbon dots (CDs, with blue emission) and thiomalic acid (TMA)-capped AgInS2 quantum dots (QDs, with orange emission) was developed aiming the photoluminescence (PL) ratiometric determination of ibandronic acid (IBAN), a bisphosphonate pharmaceutical. The ternary AgInS2 QDs were used for IBAN probing, undergoing a concentration-related PL quenching in its presence, whilst the PL of CDs remained practically unaffected due to its chemical inertness towards the antiresorptive drug, provided an intrinsic self-reference fluorophore. In addition, a visual sensing approach was also proposed, employing for the first time ternary QDs. This relied on RGB images acquired by means of a digital camera and seek the development of a rapid IBAN screening test. The developed sensing platforms were employed for IBAN determination in samples with pharmaceutical interest providing good results, in accordance to the reported IBAN levels, and obtaining recovery values between 98 and 103%.


Assuntos
Pontos Quânticos , Carbono , Corantes Fluorescentes , Ácido Ibandrônico
17.
Talanta ; 240: 123164, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972064

RESUMO

GUMBOS (Group of Uniform Materials Based on Organic Salts) have recently emerged as interesting materials for protein analysis due to their unique features and high tunability. In this regard, four novel erythrosin B (EB)-based GUMBOS were synthesized and their potential to discriminate among proteins with distinct properties (e.g., size, charge, and hydrophobicity) was assessed. These solid-phase materials were prepared using a single-step metathesis reaction between EB and various phosphonium and ammonium cations, namely tetrabutylphosphonium (P4444+), tributylhexadecylphosphonium (P44416+), tetrabutylammonium (N4444+), and benzyldimethylhexadecylammonium (BDHA+). Subsequently, the effect of pH (3.0, 4.5, and 6.0) and reaction time (5, 10, and 15 min) on the discriminatory power of synthesized GUMBOS was evaluated. Absorption spectra resulting from the interaction between EB-based GUMBOS and proteins were analyzed using partial least squares discriminant analysis (PLSDA). Unlike time, the pH value was determined to have influence over GUMBOS discrimination potential. Correct protein assignments varied from 86.5% to 100.0%, and the best discriminatory results were observed for [P4444]2[EB] and [N4444]2[EB] at pH 6.0. Additionally, these two GUMBOS allowed discrimination of protein mixtures containing different ratios of albumin and myoglobin, which appeared as individualized clusters in the PLSDA scores plots. Overall, this study showcases EB-based GUMBOS as simple synthetic targets to provide a label-free, cost-effective, rapid, and successful approach for discrimination of single proteins and their mixtures.


Assuntos
Quimiometria , Eritrosina , Proteínas , Sais , Análise Espectral
18.
Luminescence ; 26(6): 571-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21308949

RESUMO

In this work, an automated flow-based procedure for the screening of the effect of the different phenolic compounds on the chemiluminescence (CL) luminol-hydrogen peroxide-horseradish peroxidase (HRP) system is presented. This procedure involves the combination of multisyringe flow injection analysis (MFSIA) and sequential injection analysis (SIA) techniques and exploits the ability of the different subgroups of phenols, such as cholorophenols, nitrophenols, methylphenols and polyphenols, to enhance or inhibit the described CL system. The implementation of this reaction in the SIA-MSFIA system enabled favourable and precise conditions to evaluate the effect of phenolic compounds, as it involves an in-line reaction between the phenolic derivative, hydrogen peroxide and peroxidase and subsequent oxidized HRP intermediates generation prior to the fast reaction with the chemiluminogenic reagent. Several studies were then performed with the aim of establishing the appropriate flow system configuration and reaction conditions. It was shown that phenol and chlorophenols produce an enhanced CL response and nitrophenols, methylphenols and polyphenols are inhibitors within the range of concentrations studied (1-100 mg/L). Based on these studies, the developed method was applied to the determination of total polyphenol and phenol content in wine/grape seeds and water samples, respectively, and the results obtained showed good agreement with those furnished by the corresponding Folin-Ciocalteu and 4-aminoantipyrine reference methods. The developed approach is further pursued by designing an automated generic tool for performing studies of peroxidase-catalysed CL reactions of luminol focused on the detection of compounds that will affect the rate of those reactions.


Assuntos
Peroxidase do Rábano Silvestre/química , Peróxido de Hidrogênio/química , Luminol/química , Fenóis/química , Luminescência
19.
Anal Chim Acta ; 1188: 339174, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34794564

RESUMO

In this work a kinetic fluorometric methodology relying on the time-based monitoring of the photoluminescence quenching of AgInS2 ternary quantum dots induced by oxytetracycline, was developed. The kinetic approach allowed not only to reduce the LOD and improve sensitivity and selectivity but also to collect second-order data that was explored for the quantification of the target analyte in the presence of uncalibrated interfering species. Upon processing the acquired second-order kinetic PL data by unfolded partial least-squares (U-PLS), oxytetracycline was quantified in commercially available pharmaceutical formulations. The obtained results, namely an R2P higher than 0.99 and RE lower than 8%, proved the suitability and accuracy of the developed approach.


Assuntos
Oxitetraciclina , Pontos Quânticos , Fluorometria , Cinética , Análise dos Mínimos Quadrados
20.
J Inorg Biochem ; 218: 111399, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33706122

RESUMO

An automatic methodology based on micro sequential injection analysis coupled to a lab-on-valve system (termed µSIA-LOV) was developed and used to determine the ability of metal-based anticancer compounds to inhibit cyclooxygenase 2 (COX-2) activity. COX-2 may be involved in pathogenesis of cancer and it is overexpressed in several types of solid tumors. Since platinum-based compounds are extensively used in the treatment of cancer, and ruthenium compounds are considered as promising candidates for next generation of non-targeted anticancer drugs, it is interesting to establish whether COX-2 inhibition is relevant to their mode of action. The µSIA-LOV system was optimized and the IC50 values of each compound were calculated. All the results present RSD values less than 2.5%. IC50 values of 9.7 ±â€¯0.6 µM to 207 ±â€¯3 µM were obtained, with the most active inhibitor for COX-2 being rofecoxib with the metal compounds exhibiting IC50 values in the range 13.7 ±â€¯1.6 to 207 ±â€¯3. The results obtained in this work provide significant information about the mechanism of the studied compounds, mostly ruthenium-based compounds, and the role of COX-2 in their mode of action. Moreover, this work confirmed the potential of the µSIA-LOV system as a simple, versatile, robust, and rapid analytical tool for automating the determination of IC50 values of metal-based compounds.


Assuntos
Antineoplásicos/farmacologia , Inibidores de Ciclo-Oxigenase 2/farmacologia , Ciclo-Oxigenase 2/química , Lactonas/farmacologia , Metais/química , Neoplasias/tratamento farmacológico , Sulfonas/farmacologia , Antineoplásicos/química , Inibidores de Ciclo-Oxigenase 2/química , Humanos , Lactonas/química , Neoplasias/patologia , Sulfonas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA