Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Ophthalmic Physiol Opt ; 43(5): 985-996, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37340533

RESUMO

PURPOSE: Controversy exists regarding the influence of peripheral visual experience on the onset and progression of childhood myopia. This longitudinal, observational study evaluated the relationship between relative peripheral refraction (RPR) and changes in refractive error and axial length (AL) over 12 months in White children aged 6-7 and 12-13 years with a range of baseline refractive errors. METHODS: Cycloplegic baseline autorefraction at horizontal retinal eccentricities of 0° and ±30° were recorded with the Shin-Nippon NVision-K 5001 while AL was measured using the Zeiss IOLMaster 700. Measurements were repeated after 12 months on a subgroup. Refractive data were transposed into power vectors as mean spherical equivalent (M), J0 and J45 . RPR was calculated by subtracting central from peripheral measurements. Participants were defined as myopic (M ≤ -0.50 D), premyopic (-0.50 D < M ≤ +0.75 D), emmetropic (+0.75 D < M < +2.00 D) or hyperopic (M ≥ +2.00 D). RESULTS: Data were collected from 222 and 245 participants aged 6-7 and 12-13 years, respectively. Myopic eyes demonstrated, on average, more hyperopic RPR. Emmetropes and premyopes displayed emmetropic RPR, and hyperopes showed a myopic RPR. Fifty-six 6- to 7-year-olds and seventy 12- to 13-year-olds contributed 12-month repeated measures. Longitudinal data demonstrated a significant relationship between a more hyperopic RPR in the nasal retina and greater short-term axial elongation in teens with myopia at baseline (ß = 0.69; p = 0.04). Each dioptre of relative peripheral hyperopia in the nasal retina was associated with an additional 0.10 mm (95% CI: 0.02-0.18 mm) annual increase in AL. CONCLUSIONS: Hyperopic RPR in the nasal retina of myopic children is indicative of increased risk for rapid axial elongation and may be a useful metric to support decision-making in myopia management.


Assuntos
Hiperopia , Miopia , Erros de Refração , Adolescente , Criança , Humanos , Miopia/etiologia , Refração Ocular , Erros de Refração/complicações , Retina , População Branca , Estudos Longitudinais
2.
Ophthalmic Physiol Opt ; 42(1): 48-58, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34761427

RESUMO

PURPOSE: To evaluate the repeatability and reproducibility of the swept-source optical coherence tomographer Zeiss IOLMaster 700 and compare its outputs with those obtained using partial coherence interferometry (Zeiss IOLMaster v3) in a healthy, paediatric population. METHODS: This is a cross-sectional, observational study. Examiner 1 took two sets of biometric measurements (axial length [AL], mean corneal radius of curvature [Kmean ], anterior chamber depth [ACD] and lens thickness [LT]) using the IOLMaster 700, and one set of measurements (AL, Kmean and ACD) using the IOLMaster v3. Examiner 2 took one full set of measurements using the IOLMaster 700. Mean differences and 95% limits of agreement (LOA) were calculated, and Bland and Altman plots used to explore repeatability and reproducibility of the IOLMaster 700 alongside establishing its agreement with the IOLMaster v3. RESULTS: Mean participant age was 7.52 ± 0.58 years. Repeatability analyses demonstrated small mean differences and narrow 95% LOA for AL (0.001, -0.013 to 0.015 mm), Kmean (0.002, -0.020 to 0.024 mm), ACD (-0.003, -0.031 to 0.024 mm) and LT (0.001, -0.024 to 0.026 mm), respectively. Similarly, small mean differences and narrow 95% LOA established excellent reproducibility (AL 0.001, -0.016 to 0.018 mm; Kmean -0.001, -0.027 to 0.025 mm; ACD -0.010, -0.041 to 0.021 mm; LT 0.002, -0.016 to 0.020 mm). The IOLMaster 700 and IOLMaster v3 demonstrated good agreement with small mean differences and narrow 95% LOA (AL 0.009, -0.034 to 0.052 mm; Kmean 0.016, -0.013 to 0.044 mm; ACD 0.134, 0.055 to 0.212 mm). CONCLUSIONS: When used within a paediatric population, these data demonstrate the IOLMaster 700 to be highly repeatable and reproducible for measures of AL, Kmean , ACD and LT. There is excellent inter-instrument agreement between the IOLMaster 700 and IOLMaster v3 for measures of AL and Kmean . ACD measurements show weaker agreement. These data will be useful when considering reports from population-based studies of refractive error and clinical myopia research.


Assuntos
Câmara Anterior , Comprimento Axial do Olho , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Biometria , Criança , Córnea/anatomia & histologia , Estudos Transversais , Humanos , Interferometria , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
3.
Ophthalmic Physiol Opt ; 41(2): 224-244, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33368471

RESUMO

PURPOSE: Cerebral visual impairment (CVI) is the leading cause of childhood visual impairment in the developed world. Despite this, there are no agreed clinical guidelines for the investigation and diagnosis of the condition. Before development of such guidelines can commence, it is important to recognise which approaches are currently employed. This systematic review evaluated the literature to identify which methods of assessment are currently used to investigate and diagnose childhood CVI. METHODS: Medline, Embase, CINAHL, Scopus and the Cochrane Library databases were systematically searched in January 2020 using defined search terms. Articles were included if they: (i) were research papers, conference abstracts or research protocols published in peer-reviewed scientific journals, or relevant textbooks; (ii) included a clinical investigation of CVI in children; (iii) provided an explanation or criteria to diagnose CVI and (iv) were specifically investigating cerebral/cortical visual impairment. Methods used to a) assess and b) diagnose CVI were extracted from included articles. 'Assessment scores' were assigned for each method employed by researchers to investigate and diagnose CVI to quantify and compare approaches between articles. A quality grading was also applied to each article. RESULTS: Of 6454 identified articles, 45 met the inclusion criteria. From these, 10 categories of assessment utilised within included articles were identified: (1) Medical history, (2) Vision assessment/ophthalmologic examination, (3) Neuroimaging, (4) Visual behaviour and direct observation, (5) Structured history-taking, (6) Visual perception tests, (7) Ocular movement and posture assessment, (8) Intelligence/IQ assessment, (9) Clinical electrophysiology and (10) Neurodevelopmental tests. In terms of diagnostic criteria, the most commonly reported approach was one of exclusion, i.e., CVI was diagnosed when visual dysfunction could not be attributed to abnormalities detected in the anterior visual pathway. CONCLUSION: There is a lack of common practice in the approaches used by clinicians to investigate and diagnose CVI in children. At present, a 'diagnosis of exclusion' remains the most common means to diagnose CVI. Development of clinical guidelines for assessment and diagnosis are necessary to ensure consistency in the diagnosis of CVI and the timely implementation of support to alleviate the impact of CVI on the child's daily living.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Técnicas de Diagnóstico Oftalmológico , Neuroimagem/métodos , Transtornos da Visão/diagnóstico , Acuidade Visual/fisiologia , Córtex Cerebral/fisiopatologia , Criança , Gerenciamento Clínico , Humanos , Transtornos da Visão/etiologia , Transtornos da Visão/fisiopatologia
4.
Ophthalmic Physiol Opt ; 41(5): 1048-1059, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34387902

RESUMO

PURPOSE: To compare real-world measures of illumination obtained with the Actiwatch-2 and Clouclip-M2 with 'gold standard' photometry measures and to evaluate the ability of Actiwatch-2 to correctly identify photometer-defined conditions: scotopic (≤0.01 lux), mesopic (0.02-3 lux), indoor photopic (>3-1,000 lux) and outdoor photopic (>1,000 lux); and Clouclip to correctly identify photometer-defined conditions within its operating range (>1 lux). Inter-device reliability of Clouclip for illumination and viewing distance measures was also investigated. METHODS: A Hagner-S2 photometer was used as reference. Measures of illumination were obtained from a range of real-world conditions. To investigate inter-device reliability, five Clouclips were simultaneously exposed to varied light conditions and object distances. RESULTS: Strong correlations existed between illumination measured with the photometer and both Actiwatch-2 (ρ = 0.99, p < 0.0001) and Clouclip (ρ = 0.99, p < 0.0001). However, both devices underestimated illumination compared to the photometer; disparity increased with increasing illumination and was greater for Actiwatch-2 than Clouclip measures. Actiwatch-2 successfully categorised illumination level (scotopic, mesopic, indoor and outdoor photopic) in 71.2% of cases. Clouclip successfully categorised illumination levels as scotopic/mesopic (≤3 lux) and indoor and outdoor photopic in 100% of cases. Mean differences and limits of agreement (LOA) were 430.92 ± 1,828.74 and 79.35 ± 407.33 lux, between the photometer and Actiwatch-2 and photometer and Clouclip, respectively. The Intra-class Correlation Coefficients for illumination and viewing distance measured with five Clouclips were 0.85 and 0.96, respectively. CONCLUSION: These data illustrate that different Clouclip devices produce comparable measures of viewing distance and illumination in real-world settings. Both Actiwatch-2 and Clouclip underestimate illumination in the field compared to gold standard photometer measures. The disparity increases at higher levels of illumination and the discrepancy was greater for Actiwatch-2 measures. For researchers interested in categorising light exposure, Clouclip classifies illumination levels >2 lux more accurately than Actiwatch-2 but cannot discriminate between scotopic and low mesopic light.


Assuntos
Visão de Cores , Iluminação , Humanos , Reprodutibilidade dos Testes
5.
Optom Vis Sci ; 97(3): 198-206, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32168243

RESUMO

SIGNIFICANCE: Pupillometry protocols evaluating rod/cone- and melanopsin-driven responses often use mydriatics to ensure maximal stimulus exposure; however, retinal effects of mydriatics are not fully understood. We demonstrate that dilation with either atropine or phenylephrine results in similar enhancements of rod/cone- and melanopsin-driven pupil responses. PURPOSE: The purposes of this study were to compare the effects of atropine, a muscarinic antagonist, and phenylephrine, an adrenergic agonist, on consensual pupil responses and to assess the repeatability of pupil metrics without mydriasis. METHODS: Right eye pupil responses of 20 adults aged 21 to 42 years were recorded before and 45 minutes after instillation of 0.5% atropine or 2.5% phenylephrine in the left eye. Stimuli were presented to the left eye and included six alternating 1-second 651-nm "red" and 456-nm "blue" flashes. Metrics included baseline pupil diameter, maximal constriction, 6- and 30-second post-illumination pupil responses, and early (0 to 10 seconds) and late (10 to 30 seconds) areas under the curve. RESULTS: Dilation of the stimulated eye with either mydriatic significantly increased the 6-second post-illumination pupil response and early and late areas under the curve for blue stimuli, and early area under the curve for red stimuli (P < .05 for all). Melanopsin-driven post-illumination pupil responses, achieved with either phenylephrine or atropine, did not significantly differ from each other (P > .05 for all). Without mydriasis, intersession intraclass correlation coefficients for pupil metrics were 0.63 and 0.50 (6- and 30-second post-illumination pupil responses, respectively) and 0.78 and 0.44 (early and late areas under the curve, respectively) for blue stimuli, with no significant difference between sessions (P > .05 for all). CONCLUSIONS: Dilation with phenylephrine or atropine resulted in similar enhancements of the rod/cone- and melanopsin-driven pupil responses, despite differing mechanisms. Early pupil metrics without mydriasis demonstrated moderate to good intersession repeatability.


Assuntos
Atropina/farmacologia , Midriáticos/farmacologia , Fenilefrina/farmacologia , Pupila/efeitos dos fármacos , Opsinas de Bastonetes/metabolismo , Administração Oftálmica , Agonistas de Receptores Adrenérgicos alfa 1/farmacologia , Adulto , Feminino , Humanos , Masculino , Antagonistas Muscarínicos/farmacologia , Soluções Oftálmicas , Estimulação Luminosa , Células Fotorreceptoras de Vertebrados/efeitos dos fármacos , Células Fotorreceptoras de Vertebrados/metabolismo , Reflexo Pupilar/fisiologia , Adulto Jovem
6.
Augment Altern Commun ; 36(1): 54-62, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32248709

RESUMO

Learning to read and spell is an important but difficult achievement for children who have complex communication needs. Given that assessment is a vital part of any intervention program, one major barrier is the lack of reliable and valid assessments for this population. This study evaluated the reliability and validity of Dynamic Assessment of the Alphabetic Principle (DAAP), which does not require spoken responses. For this study, 27 preschool and school-aged children with typical development completed the DAAP and other standard measures of phonemic awareness and early literacy. Results indicated the DAAP had high internal consistency and strong correlations among its subtests, indicating high reliability. Moreover, performance on the DAAP had high correlations with standard measures of phonemic awareness and early literacy, providing evidence of its validity. Consequently, the DAAP represents one approach to fill the important need for assessments of early literacy that do not require speech responses.


Assuntos
Alfabetização , Fonética , Criança , Pré-Escolar , Auxiliares de Comunicação para Pessoas com Deficiência , Transtornos da Comunicação/reabilitação , Feminino , Voluntários Saudáveis , Humanos , Testes de Linguagem , Masculino , Leitura , Reprodutibilidade dos Testes
7.
Optom Vis Sci ; 96(8): 587-598, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31318801

RESUMO

SIGNIFICANCE: This study highlights potential differences that can arise in gaze-position estimates from first Purkinje image-based eye trackers based on how individual Hirschberg ratios (HRs) are calculated. PURPOSE: The purpose of this study was to evaluate the accuracy and repeatability of eccentric-viewing, prism-based, and theoretical techniques that are routinely used to calibrate HR in first Purkinje image-based eye trackers. METHODS: Hirschberg ratios of 28 participants (18 to 40 years old) were obtained using the PlusOptix PowerRef 3 photorefractor and eye tracker. In the gold standard eccentric-viewing technique, participants viewed eccentric targets (±12°, 4° steps) at 2 m. In the prism-based technique, 4 to 16Δ-D base-out and base-in prisms were placed in 4Δ-D steps before an eye occluded with an infrared filter; the fellow eye fixated a target at 1 m. Each participant's HR was calculated as the slope of the linear regression of the shift in Purkinje image relative to the pupil center for each target eccentricity or induced prism power. Theoretical HR was calculated from the participant's corneal curvature and anterior chamber depth measures. Data collection was repeated on another visit using all three techniques to assess repeatability. Data were also obtained from an Indian cohort (n = 30, 18 to 40 years old) using similar protocols. RESULTS: Hirschberg ratio ranged from 10.61 to 14.63°/mm (median, 11.90°/mm) in the eccentric-viewing technique. The prism-based and theoretical techniques demonstrated inaccuracies of 12 and 4% relative to the eccentric-viewing technique. The 95% limits of agreement of intrasubject variability were ±2.00, ±0.40, and ±0.30°/mm for the prism-based, eccentric-viewing, and theoretical techniques, respectively (P > .05). Intraclass correlation coefficients (95% confidence interval) were 0.99 (0.98 to 1.00) for eccentric, 0.99 (0.99 to 1.00) for theoretical, and 0.88 (0.74 to 0.94) for prism-based techniques. Similar results were found for the Indian cohort. CONCLUSIONS: The prism-based and theoretical techniques both demonstrated relative inaccuracies in measures of HR compared with the eccentric-viewing technique. The prism-based technique exhibited the poorest repeatability.


Assuntos
Movimentos Oculares/fisiologia , Fixação Ocular/fisiologia , Fotogrametria/normas , Gravação em Vídeo/normas , Adolescente , Adulto , Calibragem , Feminino , Humanos , Masculino , Pupila/fisiologia , Reprodutibilidade dos Testes , Adulto Jovem
8.
Ophthalmic Physiol Opt ; 39(3): 148-161, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30957261

RESUMO

PURPOSE: To survey a large number of UK-based optometrists, in a variety of settings, to determine current attitudes relating to the use of cycloplegia and spectacle prescribing in children aged ≤11 years. METHODS: One thousand randomly selected members of the College of Optometrists (UK) were invited to complete an electronic questionnaire. The questionnaire was comprised of 42 questions relating to respondent demographics, practitioner use of cycloplegia and attitudes to using cycloplegia to assess childhood refractive error and prescribing spectacles for children aged ≤11 years. RESULTS: Three hundred and eleven practitioners (31%) completed the questionnaire. Practitioners agreed that they are confident carrying out cycloplegic refraction (60%) and instilling cyclopentolate (77%); are not concerned about the time the procedure takes (69%); feel parents are receptive to its use (65%) and are not discouraged by side effects (72%). Most practitioners agreed that they would carry out a cycloplegic refraction in pre-school children (aged 2-4 years) at their first eye exam (34% vs 27%), but would not carry out a cycloplegic refraction in a child of school age (5-7 years: 25% vs 47%, 8-11 years: 12% vs 45%). More recently qualified practitioners are more likely to be proactive in using cycloplegia (Mann-Whitney, p = 0.003). Community practitioners prescribed at slightly lower levels of ametropia in non-strabismic children than those working in a hospital setting both in the present study and in comparison to previously published hospital optometry values, particularly for hyperopia at 1 year of age. CONCLUSIONS: This is the first study to report practitioner use of cycloplegia and attitudes to using cycloplegia to assess childhood refractive error and prescribing spectacles for children in a large number of UK-based optometrists practising in a variety of settings. The majority of practitioners responded in a positive manner to the use of cycloplegia and reported patterns of use which adhere closely to available professional guidance. However, outcomes indicate practitioners may appreciate more comprehensive evidence-based resources to inform their decision-making relating to use of cycloplegia in paediatric examination.


Assuntos
Ciclopentolato/administração & dosagem , Óculos/estatística & dados numéricos , Midriáticos/administração & dosagem , Optometria/métodos , Padrões de Prática Médica/estatística & dados numéricos , Erros de Refração , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Prescrições/estatística & dados numéricos , Erros de Refração/diagnóstico , Erros de Refração/reabilitação , Reino Unido
9.
Ophthalmic Physiol Opt ; 39(4): 272-281, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31236978

RESUMO

PURPOSE: This study was designed with the aim of providing practitioners with an evidence base to inform their clinical decision making as to when cycloplegic retinoscopy is necessary and when it might be appropriate to forgo. The study aimed to determine the age at which there ceases to be a clinically significant difference between cycloplegic and non-cycloplegic retinoscopy and whether age, refractive error, habitual spectacle wear and accommodation influence the relationship. METHODS: A single examiner carried out cycloplegic and non-cycloplegic retinoscopy on 128 children stratified into four age groups (6-7, 8-9, 10-12 and 12-13 years). Cycloplegia was achieved using 1% cyclopentolate and retinoscopy carried out after 30 min. The examiner was masked to the lenses used and to habitual spectacle wear. Accommodation was assessed using dynamic retinoscopy prior to cycloplegia. RESULTS: Cycloplegic and non-cycloplegic sphere differed significantly (z = -9.18, p < 0.0001). Although the difference decreased significantly as age increased (χ2  = 16.57, p = 0.0009), cycloplegic retinoscopy revealed more hyperopia than non-cycloplegic retinoscopy in all age groups (p < 0.0001). The difference between cycloplegic and non-cycloplegic results was greater where 'high' hyperopia (≥+2.50DS) was present (F1,6  = 12.86, p = 0.0005), and as hyperopia increased the difference increased (Spearman's ρ = 0.55, p < 0.0001). Neither spectacle wear (p = 0.74) nor accommodation (p = 0.08) influenced the difference between spherical measures. Measures of astigmatic error did not differ significantly (z = -1.59, p = 0.11). A non-cycloplegic sphere ≥+1.50DS was relatively sensitive (87%) and specific (96%) at indicating clinically significant hyperopia (≥+2.50D) as revealed by cycloplegic retinoscopy. CONCLUSIONS: Cyclopentolate 1% does not impact the cylindrical component of the retinoscopy result, but reveals significantly more hyperopia in the spherical component, both statistically and clinically in children aged 6-13 years. Differences between cycloplegic and non-cycloplegic sphere increase significantly with increasing hyperopia, independent of spectacle wear and accommodation. A non-cycloplegic retinoscopy result of ≥+1.50DS may be used by practitioners wishing to identify children aged 6-13 years at risk of clinically significant hyperopia (≥+2.50DS), but cycloplegia is required to accurately ascertain the full spherical error.


Assuntos
Ciclopentolato/administração & dosagem , Midriáticos/administração & dosagem , Erros de Refração/diagnóstico , Retinoscopia/métodos , Adolescente , Fatores Etários , Criança , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
10.
Optom Vis Sci ; 95(3): 193-201, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29424829

RESUMO

SIGNIFICANCE: Accommodative responses were significantly poorer in individuals with autism spectrum disorder (ASD) compared with age-matched typically developing control subjects, and hypoaccommodation was associated with reduced near visual acuity (NVA) and convergence. PURPOSE: Autism spectrum disorder is a neurodevelopmental disorder with a reported prevalence of 1.1 to 1.5%. Accommodative dysfunction has been noted in other developmental conditions including cerebral palsy and Down syndrome. The aim of this study was to investigate how accommodative accuracy and near visual function in ASD compared with typically developing control subjects. METHODS: This study investigated accommodative function in children with ASD, in conjunction with other vision measures with habitual refractive corrections. Accommodative accuracy was assessed using modified Nott dynamic retinoscopy. Individual accommodative demand and response were calculated incorporating residual refractive error (difference between cycloplegic and habitual refractive state). Near visual measures included NVA, near point of convergence, fusional reserves, and stereoacuity. Cycloplegic autorefraction confirmed refractive error. RESULTS: Accommodative responses were measured from 124 participants with ASD (6 to 17 years old) and 204 age-matched control subjects. There was no significant difference in the magnitude of residual refractive error between groups (P = .10). The prevalence of a clinically significant lag of accommodation was greater in the ASD group compared with control subjects (ASD = 17.4%, control subjects = 4.9%, χ = 13.04, P < .0001). Near visual acuity was significantly reduced in the ASD group with a clinically significant lag of accommodation (P < .01). A few participants (n = 24 control subjects, n = 14 ASD) had uncorrected or undercorrected refractive errors (spherical equivalent refractive error ≥+2.00 D, >1.00 DC), and when these were removed from analysis, there was still an increased prevalence of hypoaccommodation in ASD (14.7%). CONCLUSIONS: Children with ASD were significantly more likely to have accommodative deficits (and associated near visual deficits) in their presenting refractive state than typically developing children. Appraisal of refractive error, accommodation, and NVA should be considered in visual assessment of children with ASD.


Assuntos
Acomodação Ocular/fisiologia , Transtorno do Espectro Autista/fisiopatologia , Erros de Refração/fisiopatologia , Adolescente , Criança , Feminino , Humanos , Masculino , Retinoscopia , Testes Visuais , Acuidade Visual/fisiologia
11.
Ophthalmic Physiol Opt ; 37(1): 16-23, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28030881

RESUMO

PURPOSE: To evaluate the intra- and inter-examiner repeatability of cycloplegic retinoscopy in young children aged 4-5 years old. METHODS: Examiner 1 refracted all children in the first sample (n = 108); firstly with masked loose lenses, then using unmasked loose lenses (intra-examiner repeatability). Examiners 1 and 2 refracted all children in the second sample (n = 97) using unmasked loose lenses, blind to the child's refractive error, presence/magnitude of habitual spectacle correction and to each other's findings (inter-examiner repeatability). Refractions were performed on one eye chosen at random. Mean differences, 95% limits of agreement (LOAs) and confidence intervals were calculated for intra- and inter-examiner repeatability of sphere, cylinder and spherical equivalent refraction (SER). RESULTS: Participants had a wide range of refractive errors (-1.50DS to +7.25DS; ≥4.50DC). Mean differences (95% LOAs) were small for both intra- and inter-examiner repeatability [Intra: Sphere 0.00D (-0.85, +0.85D), Cylinder -0.03D (-0.68, +0.62D), SER -0.06D (-0.90, +0.78D); Inter: Sphere -0.08D (-0.92, +0.76D), Cylinder -0.08D (-0.75, +0.59D), SER -0.13D (-0.95, +0.69D). A statistically significant proportional bias was present for intra-examiner repeatability of cylinder (ρ = 0.20, p = 0.04) and SER measurement (ρ = 0.19, p = 0.049). Proportional bias was not present for any other measure (p > 0.12). Examiners agreed on cylinder axis within ±20° in 71% of refractions where astigmatism of -0.75D or higher was present. 80% of intra- and inter-examiner measures fell within ±0.50D for spherical and cylindrical components. CONCLUSIONS: Differences of ±1.00D and ±0.75D or more for spherical and cylindrical measures respectively can be considered significant when performing cycloplegic retinoscopy on young children.


Assuntos
Midriáticos/farmacologia , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Retina/diagnóstico por imagem , Retinoscopia/métodos , Pré-Escolar , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Erros de Refração/fisiopatologia , Seleção Visual/métodos
12.
Ophthalmic Physiol Opt ; 37(5): 557-567, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28721695

RESUMO

PURPOSE: Experimental animal models of myopia demonstrate that higher melatonin (Mel) and lower dopamine (DA) concentrations actively promote axial elongation. This study explored the association between myopia and serum concentrations of DA and Mel in humans. METHODS: Morning serum concentrations of DA and Mel were measured by solid phase extraction-liquid chromatography-tandem mass spectrometry from 54 participants (age 19.1 ± 0.81 years) in September/October 2014 (phase 1) and March/April 2016 (phase 2). Axial length (AL), corneal radii (CR) and spherical equivalent refraction (SER) were also recorded. Participants were defined as myopic if non-cycloplegic spherical equivalent refractive error ≤-0.50 DS at phase 1. RESULTS: Nine participants were lost to follow up. Mel concentrations were measurable for all myopes (phase 1 n = 25, phase 2 n = 22) and non-myopes (phase 1 n = 29, phase 2 n = 23). SER did not change significantly between phases (p = 0.51). DA concentrations were measurable for fewer myopes (phase 1 n = 13, phase 2 n = 12) and non-myopes (phase 1 n = 23, phase 2 n = 16). Myopes exhibited significantly higher Mel concentrations than non-myopes at phase 1 (Median difference: 10 pg mL-1 , p < 0.001) and at phase 2 (Median difference: 7.3 pg mL-1 , p < 0.001) and lower DA concentrations at phase 2 (Median difference: 4.7 pg mL-1 , p = 0.006). Mel concentrations were positively associated with more negative SER (all r ≥ -0.53, all p < 0.001), longer AL (all r ≥ 0.37, all p ≤ 0.008) and higher AL/CR ratio (all r ≥ 0.51, all p < 0.001). CONCLUSION: This study reports for the first time in humans that myopes exhibit higher serum Mel concentrations than non-myopes. This may indicate a role for light exposure and circadian rhythm in the human myopic growth mechanism. Further research should focus on younger cohorts exhibiting more dynamic myopic progression and explore the profile of these neurochemicals alongside evaluation of sleep patterns in myopic and non-myopic groups.


Assuntos
Melatonina/sangue , Miopia/sangue , Refração Ocular , Adolescente , Biomarcadores/sangue , Cromatografia Líquida , Feminino , Seguimentos , Humanos , Masculino , Miopia/fisiopatologia , Estudos Retrospectivos , Adulto Jovem
14.
Ophthalmic Physiol Opt ; 36(4): 395-403, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26897735

RESUMO

PURPOSE: Autistic Spectrum Disorder (ASD) is a common neurodevelopmental disorder characterised by impairment of communication, social interaction and repetitive behaviours. Only a small number of studies have investigated fundamental clinical measures of vision including refractive error. The aim of this study was to describe the refractive profile of a population of children with ASD compared to typically developing (TD) children. METHODS: Refractive error was assessed using the Shin-Nippon NVision-K 5001 open-field autorefractor following the instillation of cyclopentolate hydrochloride 1% eye drops. RESULTS: A total of 128 participants with ASD (mean age 10.9 ± 3.3 years) and 206 typically developing participants (11.5 ± 3.1 years) were recruited. There was no significant difference in median refractive error, either by spherical equivalent or most ametropic meridian between the ASD and TD groups (Spherical equivalent, Mann-Whitney U307 = 1.15, p = 0.25; Most Ametropic Meridian, U305 = 0.52, p = 0.60). Median refractive astigmatism was -0.50DC (range 0.00 to -3.50DC) for the ASD group and -0.50DC (Range 0.00 to -2.25DC) for the TD group. Magnitude and prevalence of refractive astigmatism (defined as astigmatism ≥1.00DC) was significantly greater in the ASD group compared to the typically developing group (ASD 26%, TD 8%, magnitude U305 = 3.86, p = 0.0001; prevalence (χ12=17.71 , p < 0.0001). CONCLUSIONS: This is the first study to describe the refractive profile of a population of European Caucasian children with ASD compared to a TD population of children. Unlike other neurodevelopmental conditions, there was no increased prevalence of spherical refractive errors in ASD but astigmatic errors were significantly greater in magnitude and prevalence. This highlights the need to examine refractive errors in this population.


Assuntos
Astigmatismo/etnologia , Transtorno Autístico/complicações , Refração Ocular/fisiologia , População Branca , Adolescente , Astigmatismo/complicações , Astigmatismo/fisiopatologia , Criança , Feminino , Humanos , Masculino , Irlanda do Norte/epidemiologia , Prevalência , Testes Visuais
15.
Ophthalmic Physiol Opt ; 36(4): 359-69, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27350182

RESUMO

PURPOSE: Conjunctival ultraviolet autofluorescence (CUVAF) has been used in previous Southern Hemisphere myopia research as a marker for time spent outdoors. The validity of CUVAF as an indicator of time spent outdoors is yet to be explored in the Northern Hemisphere. It is unclear if CUVAF represents damage attributed to UV exposure or dry eye. This cross-sectional study investigated the association between CUVAF measures, self-reported time spent outdoors and measures of dry eye. METHODS: Participants were recruited from University staff and students (n = 50, 19-64 years; mean 41). None were using topical ocular medications (with the exception of dry eye treatments). Sun exposure and dry eye questionnaires (Ocular Surface Disease Index and McMonnies) were completed by the participant. Dryness was also assessed using slit lamp biomicroscopy and invasive tear break up time. Images of the temporal and nasal conjunctiva from the right and left eye were captured using a bespoke photography system. The total CUVAF area, average CUVAF pixel intensity per mm(2) and total CUVAF pixel intensity were analysed using MATLAB R2013a (The MathWorks Inc). RESULTS: Of the 50 participants, 42% were classified as having dry eye. Self-reported sunglasses use was negatively associated with all CUVAF measures (Kruskal Wallis total CUVAF area, p = 0.04, ptrend  = 0.03, average CUVAF pixel intensity p = 0.02, ptrend  = 0.02, total CUVAF pixel intensity: p = 0.04, ptrend  = 0.02). Time spent outdoors was positively associated with all CUVAF measures (Spearman's correlation coefficients, total CUVAF area: r = 0.37, p = 0.01, average CUVAF pixel intensity: r = 0.36, p = 0.01, total CUVAF pixel intensity: r = 0.37, p = 0.01) and remained significant when sunglasses use was controlled for (partial correlation, total CUVAF area: r = 0.32, p = 0.03, average CUVAF pixel intensity: r = 0.39, p = 0.01, total CUVAF pixel intensity: r = 0.39, p = 0.03). Neither CUVAF area nor intensity measures were associated with any dry eye measure (Ocular Surface Disease Index: all p ≥ 0.41, corneal staining: all p ≥ 0.38, McMonnies: all r ≤ 0.09 all p ≥ 0.52, slit lamp biomicroscopy: all r ≤ 0.20 all p ≥ 0.17, invasive tear break up time: all r ≤ -0.07 all p ≥ 0.31). CONCLUSIONS: CUVAF area and intensity were not associated with clinical measures of dry eye. Greater CUVAF area and intensity were associated with wearing sunglasses less frequently and spending more time outdoors. If sunglass wear is accounted for, CUVAF may be a useful biomarker of time spent outdoors in future myopia studies.


Assuntos
Túnica Conjuntiva/patologia , Síndromes do Olho Seco/diagnóstico , Exposição Ambiental/efeitos adversos , Imagem Óptica/métodos , Raios Ultravioleta , Adulto , Estudos Transversais , Síndromes do Olho Seco/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fotografação , Inquéritos e Questionários , Adulto Jovem
16.
Ophthalmic Physiol Opt ; 34(3): 346-52, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24345090

RESUMO

PURPOSE: To assess the validity of questionnaire use in the self-identification of refractive status. METHODS: Two hundred and forty adults (21-60 years of age) presenting for a routine eye examination at various optometric practices in Northern Ireland were asked to complete one of two questionnaires. Both questionnaires used identical questions to ascertain age, gender, current spectacle use, age of first spectacle use and level of education. For the identification of refractive status, Questionnaire 1 used layman's terminology whilst Questionnaire 2 combined optometric terminology with descriptive explanations. Current refractive status was identified by the examining optometrist who did not see the completed questionnaire. The spherical equivalent refractive error of the non-cycloplegic subjective refraction was used to categorise myopia as <0D and hyperopia as ≥+1.00D. Astigmatism was defined according to two different criteria: ≥0.50DC and ≥1.00DC. RESULTS: Questionnaire 1 had a sensitivity of 0.63 and a specificity of 0.90 for identifying myopia; a sensitivity of 0.58 and a specificity of 0.71 for identifying hyperopia; a sensitivity of 0.12 and a specificity of 0.98 for identifying astigmatism ≥0.50DC and a sensitivity of 0.19 and a specificity of 0.95 for identifying astigmatism ≥1.00DC. Questionnaire 2 had a sensitivity of 0.83 and a specificity of 0.93 for identifying myopia; a sensitivity of 0.45 and a specificity of 0.86 for identifying hyperopia; a sensitivity of 0.32 and a specificity of 0.88 for identifying astigmatism ≥0.50DC and a sensitivity of 0.50 and a specificity of 0.84 for identifying astigmatism ≥1.00DC. For both questionnaires, altering a positive self-identification of myopia to include only those who had worn spectacles prior to age 30 reduced the sensitivity and increased the specificity slightly. CONCLUSIONS: Questionnaires are a valid tool in self-identification of myopic refractive status. However, they are not an effective way of identifying hyperopia and astigmatism and objective or subjective refraction remains the most appropriate method of identifying such individuals.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Erros de Refração/diagnóstico , Inquéritos e Questionários/normas , Adulto , Autoavaliação Diagnóstica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Irlanda do Norte , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
17.
Ophthalmic Physiol Opt ; 34(3): 369-75, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24446667

RESUMO

PURPOSE: To explore the onset and progression of spherical refractive error in a population with infantile nystagmus syndrome. METHODS: Retrospective refractive error data were obtained from 147 medical records of children with infantile nystagmus syndrome (albinism n = 98; idiopathic infantile nystagmus n = 49), attending a low vision clinic in Northern Ireland, over a 24 year period (1986-2010). Data were categorised by age to allow for comparisons with published studies. A prospective group of participants with Infantile nystagmus syndrome (INS) [n = 22 (albinism n = 18, idiopathic infantile nystagmus n = 4)] (aged 0-4) were also recruited. Cycloplegic streak retinoscopy was performed biannually, over a 3 year period. Spherical equivalent refractive error and most ametropic meridian were analysed. RESULTS: The mean spherical equivalent refractive errors for albinism and idiopathic infantile nystagmus groups (across all age categories) were hypermetropic, with highest levels demonstrated by the participants with albinism aged 1 ≤ 4 years (Mann-Whitney U test, p = 0.013). Mean most ametropic meridian was highest in the albinism group aged 1 ≤ 12 years (Mann-Whitney U test, p < 0.05). Individual data demonstrated relatively static spherical equivalent refractive errors over time. Prospective participants were hypermetropic at all visits and those with albinism had, on average, higher refractive errors than those with idiopathic infantile nystagmus (IIN). No significant correlations were noted between visual acuity and spherical equivalent refractive errors or most ametropic meridian. CONCLUSIONS: Hypermetropia is the most prevalent spherical refractive error in the INS population, irrespective of level of visual acuity. Individuals with infantile nystagmus syndrome fail to demonstrate typical patterns of emmetropisation, particularly in the presence of albinism.


Assuntos
Nistagmo Congênito/complicações , Erros de Refração/epidemiologia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Estudos Longitudinais , Masculino , Irlanda do Norte/epidemiologia , Prevalência , Estudos Retrospectivos
18.
Augment Altern Commun ; 30(1): 71-82, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24564701

RESUMO

Most assessments of phonemic awareness require speech responses and cannot be used with individuals with severe speech impairments who may use augmentative and alternative communication (AAC). This study investigated the reliability and construct validity of the Dynamic Assessment of Phonemic Awareness via the Alphabetic Principle (DAPA-AP), which does not require speech. In all, 17 adults with mild to moderate intellectual disabilities completed the DAPA-AP, a letter-sound knowledge task, four measures of phonological awareness, and two reading assessments. Results indicated the DAPA-AP was both a reliable and valid assessment of phonemic awareness for this sample. Consequently, the DAPA-AP represents an important step in developing phonemic awareness assessments that have the potential to be suitable for use with a wide range of individuals, including those with SSI.

19.
Eye (Lond) ; 38(7): 1333-1341, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38200321

RESUMO

BACKGROUND/OBJECTIVES: Axial length, a key measurement in myopia management, is not accessible in many settings. We aimed to develop and assess machine learning models to estimate the axial length of young myopic eyes. SUBJECTS/METHODS: Linear regression, symbolic regression, gradient boosting and multilayer perceptron models were developed using age, sex, cycloplegic spherical equivalent refraction (SER) and corneal curvature. Training data were from 8135 (28% myopic) children and adolescents from Ireland, Northern Ireland and China. Model performance was tested on an additional 300 myopic individuals using traditional metrics alongside the estimated axial length vs age relationship. Linear regression and receiver operator characteristics (ROC) curves were used for statistical analysis. The contribution of the effective crystalline lens power to error in axial length estimation was calculated to define the latter's physiological limits. RESULTS: Axial length estimation models were applicable across all testing regions (p ≥ 0.96 for training by testing region interaction). The linear regression model performed best based on agreement metrics (mean absolute error [MAE] = 0.31 mm, coefficient of repeatability = 0.79 mm) and a smooth, monotonic estimated axial length vs age relationship. This model was better at identifying high-risk eyes (axial length >98th centile) than SER alone (area under the curve 0.89 vs 0.79, respectively). Without knowing lens power, the calculated limits of axial length estimation were 0.30 mm for MAE and 0.75 mm for coefficient of repeatability. CONCLUSIONS: In myopic eyes, we demonstrated superior axial length estimation with a linear regression model utilising age, sex and refractive metrics and showed its clinical utility as a risk stratification tool.


Assuntos
Comprimento Axial do Olho , Miopia , Refração Ocular , Humanos , Miopia/fisiopatologia , Miopia/diagnóstico , Masculino , Feminino , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Adolescente , Criança , Refração Ocular/fisiologia , Curva ROC , Biometria/métodos , Adulto Jovem , Cristalino/fisiopatologia , Cristalino/diagnóstico por imagem , Cristalino/patologia , Modelos Lineares , Córnea/patologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
20.
Optom Vis Sci ; 90(12): 1396-405, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24141633

RESUMO

PURPOSE: To investigate crystalline lens thickness (LT) across a range of ages and accommodative demands and to evaluate the repeatability of LT measurements using the Visante Anterior Segment Optical Coherence Tomographer (AS-OCT) (Zeiss Meditec, Germany) under non-cycloplegic conditions. METHODS: Participants were 98 visually normal adults aged 18-75 years, stratified into age groups of 18-29, 30-39, 40-49, 50-59, and 60-75 years of age. Images of the crystalline lens were taken using the Visante AS-OCT during stimulation of accommodation at demands of 0, 1, 2, 3, 4, 5, and 8 D with accommodative response measured in a subgroup of participants. Images were analyzed and LT measured assuming a refractive index of 1.42. Repeat measures were taken from 86 participants for each accommodative demand at a second visit. RESULTS: The mean unaccommodated LT for all participants was 4.07 ± 0.40 mm. An average increase in LT of 20 µm per year was calculated (linear regression, R² = 0.61, F(1,89) = 143.92, p < 0.00001). Increase in LT with accommodation was shown to be significant in the 18- to 29-year-olds (repeated measures ANOVA, F(6,105) = 96.31, p < 0.00001), 30- to 39-year-olds (F(6,93) = 71.25, p < 0.00001), and 40- to 49-year-olds (F(6,90) = 12.60, p < 0.01) with little or no measureable change in the older age groups. Eighty-six participants returned for a second visit. The mean difference in LT in the unaccommodated state for all participants between visit 1 and visit 2 was 0.0006 mm (95% limits of agreement of -0.07 to 0.07 mm). The 95% limits of agreement were widest for youngest age groups and narrowest for the oldest participants. CONCLUSIONS: This study is the first to report the repeatability of LT measures using the Visante AS-OCT in the non-cyclopleged eye. It has also demonstrated the ability of the Visante AS-OCT to detect small changes in lens thickness with accommodation.


Assuntos
Acomodação Ocular/fisiologia , Envelhecimento/fisiologia , Cristalino/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem