RESUMO
BACKGROUND: The majority of prediabetic people are overweight and weight loss is still the most effective treatment strategy. The aim of this study was to evaluate the effects of short-term exercise and/or diet on weight loss and clinical parameters in subjects with insulin resistance (IR). METHODS: A total of 60 subjects (BMI≥25.0 kg/m2) were included in the study. Subjects divided into two groups as follows: diet only (DI, N.=27) and diet and exercise (DEI, N.=27). DI group received an energy restricted diet program, while DEI group received a diet combined with an exercise program for four weeks. Anthropometric measurements and biochemical parameters were assessed at baseline and at the end. RESULTS: Total body weight (BW) loss was 2.3 kg (2.5%) in DI group and 3.0 kg (3.2%) in DEI group at the end of four weeks. Fasting blood glucose (FBG) levels decreased significantly in DEI group (P=0.021). However, the reductions in FBG levels were mild and not statistically significant in DI group (P>0.05). Total cholesterol and LDL-c levels reduced in both groups, while triglyceride levels significantly decreased only in DI group (P<0.05). CONCLUSIONS: Short-term lifestyle interventions have beneficial effects on weight loss and clinical parameters associated with glucose control and lipid profile in subjects with IR. Even small changes in BW (loss of <5% of initial BW) have a positive impact on clinical parameters.
Assuntos
Glicemia , Dietoterapia/métodos , Terapia por Exercício/métodos , Obesidade/terapia , Adulto , Peso Corporal , Dieta , Exercício Físico , Feminino , Humanos , Resistência à Insulina , Estilo de Vida , Masculino , Obesidade/fisiopatologia , Sobrepeso/complicações , Redução de PesoRESUMO
OBJECTIVE: To compare the auditory outcomes of Carina middle-ear implants with those of conventional hearing aids in patients with moderate-to-severe mixed hearing loss. METHODS: The study comprised nine patients (six males, three females) who underwent middle-ear implantation with Carina fully implantable active middle-ear implants to treat bilateral moderate-to-severe mixed hearing loss. The patients initially used conventional hearing aids and subsequently received the Carina implants. The hearing thresholds with implants and hearing aids were compared. RESULTS: There were no significant differences between: the pre-operative and post-operative air and bone conduction thresholds (p > 0.05), the thresholds with hearing aids and Carina implants (p > 0.05), or the pre-operative (mean, 72.8 ± 19 per cent) and post-operative (mean, 69.9 ± 24 per cent) speech discrimination scores (p > 0.05). One of the patients suffered total sensorineural hearing loss three months following implantation despite an initial 38 dB functional gain. All except one patient showed clinical improvements after implantation according to quality of life questionnaire (Glasgow Benefit Inventory) scores. CONCLUSION: Acceptance of Carina implants is better than with conventional hearing aids in patients with mixed hearing loss, although both yield similar hearing amplification. Cosmetic reasons appear to be critical for patient acceptance.
Assuntos
Correção de Deficiência Auditiva/instrumentação , Auxiliares de Audição/estatística & dados numéricos , Perda Auditiva Condutiva-Neurossensorial Mista/reabilitação , Audição/fisiologia , Prótese Ossicular/estatística & dados numéricos , Adulto , Audiometria de Tons Puros , Audiometria da Fala , Correção de Deficiência Auditiva/métodos , Orelha Média/cirurgia , Feminino , Perda Auditiva Condutiva-Neurossensorial Mista/fisiopatologia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Percepção da Fala/fisiologiaRESUMO
OBJECTIVES: The purpose of this study was to determine prospectively whether the differences in anticoagulant and antiplatelet effects of ionic and nonionic contrast media after angiographic or clinical outcomes in patients with unstable ischemic syndromes undergoing percutaneous transluminal coronary angioplasty. BACKGROUND: The interaction of platelets and thrombin with the endothelium of injured vessels contributes to thrombosis and restenosis after coronary angioplasty. Case reports and retrospective observations have reported an increased risk of thrombosis with the use of nonionic contrast media. METHODS: A total of 211 patients with acute myocardial infarction or unstable angina undergoing coronary angioplasty were randomized to receive nonionic or ionic low osmolar contrast media. Coronary angiograms were assessed by a technician blinded to the study contrast media, and clinical events were monitored by an independent nurse for 1 month. RESULTS: Patients receiving the ionic media were significantly less likely to experience decreased blood flow during the procedure (8.1% vs. 17.8%, p = 0.04). After the angioplasty, residual stenosis, vessel patency, the incidence of moderate to large thrombi and use of adjunctive thrombolytic therapy were similar between the two groups. However, patients receiving ionic media had fewer recurrent ischemic events requiring repeat catheterization (3.0% vs. 11.4%, p = 0.02) and repeat angioplasty during the initial hospital stay (1.0% vs. 5.8%, p = 0.06). One month after angioplasty, patients receiving ionic contrast media reported significantly fewer symptoms of any angina (8.5 vs. 20.0%, p = 0.04) or of angina at rest (1.4% vs. 11.8%, p = 0.01) and a reduced need for subsequent bypass surgery (0% vs. 5.9%, p = 0.04), compared with patients receiving the nonionic media. CONCLUSIONS: These findings demonstrate that in patients with unstable ischemic syndromes undergoing coronary angioplasty, the use of ionic low osmolar contrast media reduces the risk of ischemic complications acutely and at 1 month after the procedure. Therefore, low osmolar ionic contrast media should be strongly considered when performing interventions in patients with unstable angina or myocardial infarction.
Assuntos
Angina Instável/terapia , Angioplastia Coronária com Balão , Meios de Contraste , Trombose Coronária/prevenção & controle , Infarto do Miocárdio/terapia , Angiografia Coronária , Feminino , Humanos , Íons , Masculino , Pessoa de Meia-Idade , Concentração Osmolar , Estudos Prospectivos , RecidivaRESUMO
Mono- and biexponential fitting of myocardial 11C-acetate kinetics does not account for the effect of recirculating 11C activity following intravenous injection of the tracer. A tracer kinetic model comprising two and three compartments was developed to describe intravascular and myocardial 11C-acetate kinetics defined by PET. This model approach including a correction for 11C-metabolites in blood was validated by correlating the model parameter estimates with directly measured oxygen consumption (MVO2) in 11 closed-chest dog experiments over a wide range of cardiac work. The model parameter k2 closely correlated with oxygen consumption (r = 0.94). This approach was subsequently applied to human studies and k2-related to rate-pressure product (PRP). In comparison to conventional monoexponential fitting of 11C-acetate tissue kinetics, the model approach improved the correlation coefficients of scintigraphic MVO2 estimates and PRP values from 0.61 to 0.91. Thus, analysis of myocardial 11C-acetate and clearance kinetics with a tracer kinetic model corrects for recirculating 11C-activity and may provide more consistent estimates of myocardial oxygen consumption.
Assuntos
Coração/diagnóstico por imagem , Miocárdio/metabolismo , Tomografia Computadorizada de Emissão , Acetatos , Adulto , Animais , Radioisótopos de Carbono , Cães , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Consumo de Oxigênio/fisiologiaRESUMO
Evaluation of right ventricular (RV) oxidative metabolism is limited by the inability to easily determine oxygen extraction by the RV myocardium and the complex morphology of this ventricle. Because left ventricular C-11 clearance rate constants closely correlate with myocardial oxygen consumption, it was postulated that C-11 clearance rate constants for the RV free wall should also reflect its oxygen consumption. Therefore, RV C-11 clearance rate constants were compared with RV loading in 21 patients with aortic valve disease to assess the possible use of this technique for noninvasive evaluation of RV oxidative metabolism. RV free wall C-11 clearance rate constants correlated with the product of systolic pulmonary artery pressure and heart rate for all patients (r = 0.65, p = 0.002), but the relation was stronger if 2 patients with overt RV dysfunction were excluded (r = 0.83, p = 0.001). On the basis of mean pulmonary artery pressures, patients were stratified into subgroups with normal (group I, n = 8) and elevated (group II, n = 13) pulmonary pressures and were compared with 10 normal control subjects. RV C-11 clearance rate constants were significantly higher in group II than in group I and in normal control subjects (p less than 0.05). These data suggest that RV C-11 acetate clearance rate constants can provide noninvasive evaluation of RV oxidative metabolism. This technique may allow serial assessment of RV performance in various cardiac and pulmonary diseases, and particularly of changes associated with therapeutic interventions.
Assuntos
Acetatos , Valva Aórtica , Miocárdio/metabolismo , Acetatos/metabolismo , Idoso , Pressão Sanguínea/fisiologia , Radioisótopos de Carbono , Coração/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/metabolismo , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Artéria Pulmonar/fisiopatologia , Tomografia Computadorizada de EmissãoAssuntos
Angioplastia Coronária com Balão/efeitos adversos , Doença das Coronárias/terapia , Infarto do Miocárdio/terapia , Varfarina/uso terapêutico , Cateterismo Cardíaco , Doença das Coronárias/complicações , Estudos de Avaliação como Assunto , Humanos , Infarto do Miocárdio/complicações , Recidiva , Fatores de TempoAssuntos
Angioplastia Coronária com Balão , Parada Cardíaca/etiologia , Infarto do Miocárdio/terapia , Idoso , Reanimação Cardiopulmonar , Feminino , Parada Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Estudos Prospectivos , Estudos RetrospectivosRESUMO
A 22-yr-old pregnant woman with mitral, aortic, and tricuspid stenosis presented with accelerating dyspnea and shortness of breath at the end of her first trimester. She subsequently underwent percutaneous triple-valve balloon valvuloplasty at 22 weeks of gestation without complications and achieved marked clinical improvement. We conclude that percutaneous triple-valve balloon valvuloplasty represents an alternative treatment for mitral, aortic, and tricuspid stenosis in pregnant women with compromised cardiovascular status who do not wish to terminate their pregnancy.
Assuntos
Cateterismo , Doenças das Valvas Cardíacas/terapia , Complicações Cardiovasculares na Gravidez/terapia , Adulto , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Eletrocardiografia , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Estenose da Valva Mitral/terapia , Gravidez , Complicações Cardiovasculares na Gravidez/fisiopatologia , Punções , Estenose da Valva Tricúspide/terapiaRESUMO
The incidence of retained hardware components in the coronary artery tree is likely to parallel the growing number and types of percutaneous coronary revascularization procedures being performed. Management has extended from the conservative option of simply leaving behind the retained components to the more aggressive approach of surgical removal. A percutaneous method is described herein which offers the interventional cardiologist an alternative method of managing patients with retained wire fragments contained entirely in the coronary artery.
Assuntos
Angioplastia Coronária com Balão , Vasos Coronários , Corpos Estranhos/terapia , Doença das Coronárias/cirurgia , Endarterectomia/instrumentação , Falha de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Instrumentos CirúrgicosRESUMO
Cor triatriatum dexter is a rare congenital anomaly in which an obstructive membrane is located in the right atrium. The detection usually occurs after the sequelae of systemic congestion, coagulopathy, and hepatic dysfunction have set in, leading up to a high surgical risk. A percutaneous balloon correction of cor triatriatum dexter in a patient with advanced right-sided congestive symptoms and hepatic dysfunction is presented. This efficacious method is an alternative to surgical correction and could be extended to the more common cor triatriatum sinistra.
Assuntos
Cateterismo , Coração Triatriado/terapia , Adulto , Função do Átrio Direito/fisiologia , Cateterismo Cardíaco , Coração Triatriado/complicações , Coração Triatriado/diagnóstico , Ecocardiografia , Feminino , Humanos , Hipóxia/etiologia , Cirrose Hepática/etiologia , Função Ventricular Direita/fisiologiaRESUMO
C-11 acetate has recently been introduced as a tracer of myocardial oxidative metabolism with the use of positron emission tomography. To evaluate this approach in the pressure- or volume-loaded heart, C-11 acetate clearance rate constants were determined in 22 patients with chronic aortic valve disease and in nine normal subjects. Global myocardial C-11 clearance was significantly higher in patients with predominant aortic stenosis (n = 11) or aortic regurgitation (n = 11) than in normal subjects (0.069 +/- 0.017 min-1 and 0.072 +/- 0.010 min-1 compared with 0.050 +/- 0.004 min-1, p less than 0.05) and correlated significantly with the rate-pressure product corrected for mean aortic valve gradient (r = 0.73, p = 0.0001) for all studies. However, analysis of patient subgroups demonstrated that this correlation held only for aortic stenosis (r = 0.79, p less than 0.005 for gradient-corrected rate-pressure product). Additionally, C-11 clearance was strongly correlated with the product of heart rate and mean wall stress in patients with aortic stenosis (r = 0.89, p less than 0.005) but not in patients with aortic regurgitation. Normalization of C-11 acetate clearance rate constants for gradient-corrected rate-pressure product were significantly lower in patients with loaded ventricles, particularly in the presence of a low ejection fraction, compared to normal subjects. Possible mechanisms include myocardial adaptation through hypertrophy or depressed contractility, which would both tend to reduce oxygen consumption under any given load. Serial comparison of C-11 acetate kinetics and noninvasive indexes of oxygen demand may provide assessment of disease progression in pathologic ventricular loading.
Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Coração/diagnóstico por imagem , Miocárdio/metabolismo , Tomografia Computadorizada de Emissão , Acetatos , Idoso , Radioisótopos de Carbono , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Consumo de Oxigênio/fisiologiaRESUMO
BACKGROUND: Transluminal extraction coronary (TEC) atherectomy is a relatively new device that has recently been approved by the Food and Drug Administration. Because of its ability to aspirate clot and atheromatous material, TEC atherectomy may be useful in patients with stenoses in saphenous vein bypass grafts. METHODS AND RESULTS: TEC atherectomy was performed on 158 saphenous vein graft lesions in 146 consecutive patients with a mean age of 65 +/- 8 years (78% men). Clinical indications for atherectomy included stable angina (37%), unstable angina (54%), and postinfarction angina after recent (< 1 month) myocardial infarction (8%). Patients with acute myocardial infarction and target vessels < 2 mm in diameter were excluded. The mean age of the bypass graft was 8.3 +/- 3.0 years, and 17% were diffusely diseased and degenerated. Complex lesion morphology included total occlusion (6%), eccentricity (64%), ulceration (18%), and thrombus (28%). The TEC atherectomy cutter was successfully advanced through 144 lesions (91%), but technical failures occurred in 14 lesions (9%), and these were subsequently managed by successful balloon angioplasty. Quantitative angiography revealed an increase in lumen diameter from 0.9 +/- 0.5 mm, to 1.5 +/- 0.7 mm after TEC atherectomy, to 2.3 +/- 0.8 mm after percutaneous transluminal coronary angioplasty (PTCA) (P < .001), which corresponded to decreases in diameter stenosis from 75 +/- 14%, to 58 +/- 20% after TEC atherectomy, to 36 +/- 22% after PTCA (P < .001). Device success was achieved in 39.2% (post-TEC atherectomy decrease in diameter stenosis > or = 20%), and procedural success was achieved in 84% (final diameter stenosis < 50% in the absence of a major complication). Angiographic complications were evident in 33 lesions (20.7%) immediately after TEC atherectomy and in 8 lesions (5%) after PTCA, including distal embolization (11.9%), no-reflow (8.8%), and abrupt closure (5.0%), but no perforations. Adjunctive PTCA (and other medical therapy) successfully managed 61% of angiographic complications. Serious clinical complications included in-hospital death in 3 patients (2.0%), emergency bypass surgery in 1 patient who died (0.7%), Q wave myocardial infarction in 3 patients (2.0%), non-Q wave myocardial infarction in 4 patients (2.7%), vascular injury requiring surgical repair and/or blood transfusion in 9 patients (6.1%), and hemorrhagic cerebral infarction in 4 patients (2.7%). Using a composite clinical end point defined as in-hospital death, emergency bypass surgery, or myocardial infarction, the strongest independent correlate (P < .001) of a severe clinical complication was the development of one or more serious angiographic complications (no-reflow, distal embolization, or abrupt closure) immediately after TEC atherectomy. Complete clinical follow-up was available in 118 (92%) of 128 eligible patients at an interval of 6.0 +/- 2.5 months after discharge. Late cardiac outcome included recurrent angina treated with medical therapy (18%), repeat percutaneous intervention on the original target lesion (26%), repeat coronary artery bypass surgery (5%), Q wave myocardial infarction (4%), and late cardiac death (7%). Angiographic follow-up in 105 (80%) of 132 eligible lesions revealed a restenosis rate of 69% (defined as a diameter stenosis > 50%), including 30 lesions (29%) with total occlusion of the original lesion. CONCLUSIONS: In patients with stenoses in saphenous vein bypass grafts, TEC atherectomy is limited by the frequent need for adjunctive balloon angioplasty to achieve adequate lumen enlargement and to manage TEC atherectomy-induced complications. Although the incidence of serious clinical complications is similar to that of other percutaneous interventions in vein grafts, there is a high incidence of restenosis and late vessel occlusion. Prospective randomized studies are needed to determine the best revascularization strategy for high-risk patients with old degenerated vein