Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Lancet Oncol ; 24(12): 1387-1398, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38039992

RESUMO

BACKGROUND: Stereotactic body radiotherapy (SBRT) has the potential to ablate localised pancreatic ductal adenocarcinoma. Selective dismutase mimetics sensitise tumours while reducing normal tissue toxicity. This trial was designed to establish the efficacy and toxicity afforded by the selective dismutase mimetic avasopasem manganese when combined with ablative SBRT for localised pancreatic ductal adenocarcinoma. METHODS: In this adaptive, randomised, double-blind, placebo-controlled, phase 1b/2 trial, patients aged 18 years or older with borderline resectable or locally advanced pancreatic cancer who had received at least 3 months of chemotherapy and had an Eastern Cooperative Oncology Group performance status of 0-2 were enrolled at six academic sites in the USA. Eligible patients were randomly assigned (1:1), with block randomisation (block sizes of 6-12) with a maximum of 24 patients per group, to receive daily avasopasem (90 mg) or placebo intravenously directly before (ie, within 180 min) SBRT (50, 55, or 60 Gy in five fractions, adaptively assigned in real time by Bayesian estimates of 90-day safety and efficacy). Patients and physicians were masked to treatment group allocation, but not to SBRT dose. The primary objective was to find the optimal dose of SBRT with avasopasem or placebo as determined by the late onset EffTox method. All analyses were done on an intention-to-treat basis. This study is registered with ClinicalTrials.gov, NCT03340974, and is complete. FINDINGS: Between Jan 25, 2018, and April 29, 2020, 47 patients were screened, of whom 42 were enrolled (median age was 71 years [IQR 63-75], 23 [55%] were male, 19 [45%] were female, 37 [88%] were White, three [7%] were Black, and one [2%] each were unknown or other races) and randomly assigned to avasopasem (n=24) or placebo (n=18); the placebo group was terminated early after failing to meet prespecified efficacy parameters. At data cutoff (June 28, 2021), the avasopasem group satisfied boundaries for both efficacy and toxicity. Late onset EffTox efficacy response was observed in 16 (89%) of 18 patients at 50 Gy and six (100%) of six patients at 55 Gy in the avasopasem group, and was observed in three (50%) of six patients at 50 Gy and nine (75%) of 12 patients at 55 Gy in the placebo group, and the Bayesian model recommended 50 Gy or 55 Gy in five fractions with avasopasem for further study. Serious adverse events of any cause were reported in three (17%) of 18 patients in the placebo group and six (25%) of 24 in the avasopasem group. In the placebo group, grade 3 adverse events within 90 days of SBRT were abdominal pain, acute cholangitis, pyrexia, increased blood lactic acid, and increased lipase (one [6%] each); no grade 4 events occurred. In the avasopasem group, grade 3-4 adverse events within 90 days of SBRT were acute kidney injury, increased blood alkaline phosphatase, haematoma, colitis, gastric obstruction, lung infection, abdominal abscess, post-surgical atrial fibrillation, and pneumonia leading to respiratory failure (one [4%] each).There were no treatment-related deaths but one late death in the avasopasem group due to sepsis in the setting of duodenal obstruction after off-study treatment was reported as potentially related to SBRT. INTERPRETATION: SBRT that uses 50 or 55 Gy in five fractions can be considered for patients with localised pancreatic ductal adenocarcinoma. The addition of avasopasem might further enhance disease outcomes. A larger phase 2 trial (GRECO-2, NCT04698915) is underway to validate these results. FUNDING: Galera Therapeutics.


Assuntos
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Radiocirurgia , Humanos , Masculino , Feminino , Idoso , Adenocarcinoma/radioterapia , Adenocarcinoma/tratamento farmacológico , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/tratamento farmacológico , Radiocirurgia/efeitos adversos , Teorema de Bayes , Carcinoma Ductal Pancreático/radioterapia , Carcinoma Ductal Pancreático/tratamento farmacológico , Método Duplo-Cego , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico
2.
JNCI Cancer Spectr ; 8(3)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38730548

RESUMO

BACKGROUND: Traditional constraints specify that 700 cc of liver should be spared a hepatotoxic dose when delivering liver-directed radiotherapy to reduce the risk of inducing liver failure. We investigated the role of single-photon emission computed tomography (SPECT) to identify and preferentially avoid functional liver during liver-directed radiation treatment planning in patients with preserved liver function but limited functional liver volume after receiving prior hepatotoxic chemotherapy or surgical resection. METHODS: This phase I trial with a 3 + 3 design evaluated the safety of liver-directed radiotherapy using escalating functional liver radiation dose constraints in patients with liver metastases. Dose-limiting toxicities were assessed 6-8 weeks and 6 months after completing radiotherapy. RESULTS: All 12 patients had colorectal liver metastases and received prior hepatotoxic chemotherapy; 8 patients underwent prior liver resection. Median computed tomography anatomical nontumor liver volume was 1584 cc (range = 764-2699 cc). Median SPECT functional liver volume was 1117 cc (range = 570-1928 cc). Median nontarget computed tomography and SPECT liver volumes below the volumetric dose constraint were 997 cc (range = 544-1576 cc) and 684 cc (range = 429-1244 cc), respectively. The prescription dose was 67.5-75 Gy in 15 fractions or 75-100 Gy in 25 fractions. No dose-limiting toxicities were observed during follow-up. One-year in-field control was 57%. One-year overall survival was 73%. CONCLUSION: Liver-directed radiotherapy can be safely delivered to high doses when incorporating functional SPECT into the radiation treatment planning process, which may enable sparing of lower volumes of liver than traditionally accepted in patients with preserved liver function. TRIAL REGISTRATION: NCT02626312.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Fígado , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Masculino , Feminino , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Radioterapia Guiada por Imagem/métodos , Neoplasias Colorretais/radioterapia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Tamanho do Órgão , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto
3.
Mol Imaging Biol ; 25(6): 991-1019, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37845582

RESUMO

Critical advances in radionuclide therapy have led to encouraging new options for cancer treatment through the pairing of clinically useful radiation-emitting radionuclides and innovative pharmaceutical discovery. Of the various subatomic particles used in therapeutic radiopharmaceuticals, alpha (α) particles show great promise owing to their relatively large size, delivered energy, finite pathlength, and resulting ionization density. This review discusses the therapeutic benefits of α-emitting radiopharmaceuticals and their pairing with appropriate diagnostics, resulting in innovative "theranostic" platforms. Herein, the current landscape of α particle-emitting radionuclides is described with an emphasis on their use in theranostic development for cancer treatment. Commonly studied radionuclides are introduced and recent efforts towards their production for research and clinical use are described. The growing popularity of these radionuclides is explained through summarizing the biological effects of α radiation on cancer cells, which include DNA damage, activation of discrete cell death programs, and downstream immune responses. Examples of efficient α-theranostic design are described with an emphasis on strategies that lead to cellular internalization and the targeting of proteins involved in therapeutic resistance. Historical barriers to the clinical deployment of α-theranostic radiopharmaceuticals are also discussed. Recent progress towards addressing these challenges is presented along with examples of incorporating α-particle therapy in pharmaceutical platforms that can be easily converted into diagnostic counterparts.


Assuntos
Neoplasias , Compostos Radiofarmacêuticos , Compostos Radiofarmacêuticos/uso terapêutico , Partículas alfa/uso terapêutico , Radioisótopos/uso terapêutico , Preparações Farmacêuticas , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/radioterapia
4.
Adv Radiat Oncol ; 8(4): 101164, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36798731

RESUMO

Purpose: To determine the dosimetric limitations of daily online adaptive pancreas stereotactic body radiation treatment by using an automated dose escalation approach. Methods and Materials: We collected 108 planning and daily computed tomography (CT) scans from 18 patients (18 patients × 6 CT scans) who received 5-fraction pancreas stereotactic body radiation treatment at MD Anderson Cancer Center. Dose metrics from the original non-dose-escalated clinical plan (non-DE), the dose-escalated plan created on the original planning CT (DE-ORI), and the dose-escalated plan created on daily adaptive radiation therapy CT (DE-ART) were analyzed. We developed a dose-escalation planning algorithm within the radiation treatment planning system to automate the dose-escalation planning process for efficiency and consistency. In this algorithm, the prescription dose of the dose-escalation plan was escalated before violating any organ-at-risk (OAR) dose constraint. Dose metrics for 3 targets (gross target volume [GTV], tumor vessel interface [TVI], and dose-escalated planning target volume [DE-PTV]) and 9 OARs (duodenum, large bowel, small bowel, stomach, spinal cord, kidneys, liver, and skin) for the 3 plans were compared. Furthermore, we evaluated the effectiveness of the online adaptive dose-escalation planning process by quantifying the effect of the interfractional dose distribution variations among the DE-ART plans. Results: The median D95% dose to the GTV/TVI/DE-PTV was 33.1/36.2/32.4 Gy, 48.5/50.9/40.4 Gy, and 53.7/58.2/44.8 Gy for non-DE, DE-ORI, and DE-ART, respectively. Most OAR dose constraints were not violated for the non-DE and DE-ART plans, while OAR constraints were violated for the majority of the DE-ORI patients due to interfractional motion and lack of adaptation. The maximum difference per fraction in D95%, due to interfractional motion, was 2.5 ± 2.7 Gy, 3.0 ± 2.9 Gy, and 2.0 ± 1.8 Gy for the TVI, GTV, and DE-PTV, respectively. Conclusions: Most patients require daily adaptation of the radiation planning process to maximally escalate delivered dose to the pancreatic tumor without exceeding OAR constraints. Using our automated approach, patients can receive higher target dose than standard of care without violating OAR constraints.

5.
Med Phys ; 39(9): 5457-68, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22957613

RESUMO

PURPOSE: To determine the effect of different bleaching wavelengths on the response of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. METHODS: In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.5 to 10 Gy. To determine the effect of different bleaching wavelengths on the OSLDs' response, the authors optically treated the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120, and 600 min and (ii) with a long-pass filter for 55, 600, and 2000 min. Changes in the OSLDs' sensitivity were determined for an irradiation-readout-bleaching-readout cycle after irradiations with 1 and 10 Gy dose fractions. RESULTS: The OSLDs presented supralinearity for doses of 2 Gy and above. The signal loss rates for sequential readouts were (0.287 ± 0.007)% per readout in the reader's strong-stimulation mode, and (0.019 ± 0.002)% and (0.035 ± 0.007)% per readout for doses of 0.2 and 10 Gy, respectively, in the reader's weak-stimulation mode. Fading half-life values ranged from (0.98 ± 0.14) min to (1.77 ± 0.24) min and fading showed dose dependence for the first 10-min interval. For 10 and 55 min bleaching using modes (i) and (ii), the OSL signal increased 14% for an accumulated dose of 7 Gy (1 Gy fractions). For OSLDs exposed to 10 Gy fractions, the OSL signal increased 30% and 25% for bleaching modes (i) and (ii) and accumulated dose of 70 Gy, respectively. For 120 and 600 min bleaching using modes (i) and (ii), the OSL signal increased 2.7% and 1.5% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 14% for bleaching mode (i) (120 min bleaching) and decreased 1.3% for bleaching mode (ii) (600 min bleaching) for an accumulated dose of 70 Gy. For 600 and 2000 min bleaching using modes (i) and (ii), the signal increased 2.3% and 1.8% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 10% for mode (i) (600 min bleaching) and decreased 2.5% for mode (ii) (2000 min bleaching) for an accumulated dose of 70 Gy. CONCLUSIONS: The dose-response of nanoDot OSLDs read using the MicroStar reader presented supralinearity for doses of 2 Gy and above. The signal loss as a function of sequential readouts depended on dose. Fading also depended on dose for the first 10-min interval. For dose fractions of 1 and 10 Gy, OSLDs may be reused within 3% and 5% accuracies up to the maximum accumulated dose of 7 and 70 Gy investigated in this study, respectively. These accuracies were obtained after the OSLDs were bleached with a light source with wavelengths above about 495 nm. The authors also concluded that changes in sensitivity of OSLDs depended on bleaching time, accumulated dose, and wavelength spectrum of the bleaching source.


Assuntos
Óxido de Alumínio , Carbono , Medições Luminescentes/métodos , Fenômenos Ópticos , Fótons , Humanos , Luz , Doses de Radiação
6.
Med Phys ; 39(2): 891-900, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22320798

RESUMO

PURPOSE: Planar integral spot dose (PISD) of proton pencil beam spots (PPBSs) is a required input parameter for beam modeling in some treatment planning systems used in proton therapy clinics. The measurement of PISD by using commercially available large area ionization chambers, like the PTW Bragg peak chamber (BPC), can have large uncertainties due to the size limitation of these chambers. This paper reports the results of our study of a novel method to determine PISD values from the measured lateral dose profiles and peak dose of the PPBS. METHODS: The PISDs of 72.5, 89.6, 146.9, 181.1, and 221.8 MeV energy PPBSs were determined by area integration of their planar dose distributions at different depths in water. The lateral relative dose profiles of the PPBSs at selected depths were measured by using small volume ion chambers and were investigated for their angular anisotropies using Kodak XV films. The peak spot dose along the beam's central axis (D(0)) was determined by placing a small volume ion chamber at the center of a broad field created by the superposition of spots at different locations. This method allows eliminating positioning uncertainties and the detector size effect that could occur when measuring it in single PPBS. The PISD was then calculated by integrating the measured lateral relative dose profiles for two different upper limits of integration and then multiplying it with corresponding D(0). The first limit of integration was set to radius of the BPC, namely 4.08 cm, giving PISD(RBPC). The second limit was set to a value of the radial distance where the profile dose falls below 0.1% of the peak giving the PISD(full). The calculated values of PISD(RBPC) obtained from area integration method were compared with the BPC measured values. Long tail dose correction factors (LTDCFs) were determined from the ratio of PISD(full)∕PISD(RBPC) at different depths for PPBSs of different energies. RESULTS: The spot profiles were found to have angular anisotropy. This anisotropy in PPBS dose distribution could be accounted in a reasonable approximate manner by taking the average of PISD values obtained using the in-line and cross-line profiles. The PISD(RBPC) values fall within 3.5% of those measured by BPC. Due to inherent dosimetry challenges associated with PPBS dosimetry, which can lead to large experimental uncertainties, such an agreement is considered to be satisfactory for validation purposes. The PISD(full) values show differences ranging from 1 to 11% from BPC measured values, which are mainly due to the size limitation of the BPC to account for the dose in the long tail regions of the spots extending beyond its 4.08 cm radius. The dose in long tail regions occur both for high energy beams such as 221.8 MeV PPBS due to the contributions of nuclear interactions products in the medium, and for low energy PPBS because of their larger spot sizes. The calculated LTDCF values agree within 1% with those determined by the Monte Carlo (MC) simulations. CONCLUSIONS: The area integration method to compute the PISD from PPBS lateral dose profiles is found to be useful both to determine the correction factors for the values measured by the BPC and to validate the results from MC simulations.


Assuntos
Algoritmos , Prótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Med Phys ; 49(9): 6098-6109, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35754208

RESUMO

PURPOSE: We assessed whether adding sodium borocaptate (BSH) or 4-borono-l-phenylalanine (BPA) to cells irradiated with proton beams influenced the biological effectiveness of those beams against prostate cancer cells to investigate if the alpha particles generated through proton-boron nuclear reactions would be sufficient to enhance the biological effectiveness of the proton beams. METHODS: We measured clonogenic survival in DU145 cells treated with 80.4-ppm BSH or 86.9-ppm BPA, or their respective vehicles, after irradiation with 6-MV X-rays, 1.2-keV/µm (low linear energy transfer [LET]) protons, or 9.9-keV/µm (high-LET) protons. We also measured γH2AX and 53BP1 foci in treated cells at 1 and 24 h after irradiation with the same conditions. RESULTS: We found that BSH radiosensitized DU145 cells across all radiation types. However, no difference was found in relative radiosensitization, characterized by the sensitization enhancement ratio or the relative biological effectiveness, for vehicle- versus BSH-treated cells. No differences were found in numbers of γH2AX or 53BP1 foci or γH2AX/53BP1 colocalized foci for vehicle- versus BSH-treated cells across radiation types. BPA did not radiosensitize DU145 cells nor induced any significant differences when comparing vehicle- versus BPA-treated cells for clonogenic cell survival or γH2AX and 53BP1 foci or γH2AX/53BP1 colocalized foci. CONCLUSIONS: Treatment with 11 B, at concentrations of 80.4 ppm from BSH or 86.9 ppm from BPA, had no effect on the biological effectiveness of proton beams in DU145 prostate cancer cells. Our results agree with published theoretical calculations indicating that the contribution of alpha particles from such reactions to the total absorbed dose and biological effectiveness is negligible. We also found that BSH radiosensitized DU145 cells to X-rays, low-LET protons, and high-LET protons but that the radiosensitization was not related to DNA damage.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias da Próstata , Terapia com Prótons , Compostos de Boro/farmacologia , Compostos de Boro/uso terapêutico , Humanos , Masculino , Fenilalanina/farmacologia , Fenilalanina/uso terapêutico , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Prótons , Eficiência Biológica Relativa
8.
Med Phys ; 49(9): 6221-6236, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35831779

RESUMO

BACKGROUND: Proton relative biological effectiveness (RBE) is known to depend on physical factors of the proton beam, such as its linear energy transfer (LET), as well as on cell-line specific biological factors, such as their ability to repair DNA damage. However, in a clinical setting, proton RBE is still considered to have a fixed value of 1.1 despite the existence of several empirical models that can predict proton RBE based on how a cell's survival curve (linear-quadratic model [LQM]) parameters α and ß vary with the LET of the proton beam. Part of the hesitation to incorporate variable RBE models in the clinic is due to the great noise in the biological datasets on which these models are trained, often making it unclear which model, if any, provides sufficiently accurate RBE predictions to warrant a departure from RBE = 1.1. PURPOSE: Here, we introduce a novel model of proton RBE based on how a cell's intrinsic radiosensitivity varies with LET, rather than its LQM parameters. METHODS AND MATERIALS: We performed clonogenic cell survival assays for eight cell lines exposed to 6 MV x-rays and 1.2, 2.6, or 9.9 keV/µm protons, and combined our measurements with published survival data (n = 397 total cell line/LET combinations). We characterized how radiosensitivity metrics of the form DSF% , (the dose required to achieve survival fraction [SF], e.g., D10% ) varied with proton LET, and calculated the Bayesian information criteria associated with different LET-dependent functions to determine which functions best described the underlying trends. This allowed us to construct a six-parameter model that predicts cells' proton survival curves based on the LET dependence of their radiosensitivity, rather than the LET dependence of the LQM parameters themselves. We compared the accuracy of our model to previously established empirical proton RBE models, and implemented our model within a clinical treatment plan evaluation workflow to demonstrate its feasibility in a clinical setting. RESULTS: Our analyses of the trends in the data show that DSF% is linearly correlated between x-rays and protons, regardless of the choice of the survival level (e.g., D10% , D37% , or D50% are similarly correlated), and that the slope and intercept of these correlations vary with proton LET. The model we constructed based on these trends predicts proton RBE within 15%-30% at the 68.3% confidence level and offers a more accurate general description of the experimental data than previously published empirical models. In the context of a clinical treatment plan, our model generally predicted higher RBE-weighted doses than the other empirical models, with RBE-weighted doses in the distal portion of the field being up to 50.7% higher than the planned RBE-weighted doses (RBE = 1.1) to the tumor. CONCLUSIONS: We established a new empirical proton RBE model that is more accurate than previous empirical models, and that predicts much higher RBE values in the distal edge of clinical proton beams.


Assuntos
Terapia com Prótons , Prótons , Teorema de Bayes , Terapia com Prótons/métodos , Tolerância a Radiação , Eficiência Biológica Relativa , Raios X
9.
Radiat Res ; 198(4): 336-346, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35939823

RESUMO

Small molecule inhibitors are currently in preclinical and clinical development for the treatment of selected cancers, particularly those with existing genetic alterations in DNA repair and DNA damage response (DDR) pathways. Keen interest has also been expressed in combining such agents with other targeted antitumor strategies such as radiotherapy. Radiotherapy exerts its cytotoxic effects primarily through DNA damage-induced cell death; therefore, inhibiting DNA repair and the DDR should lead to additive and/or synergistic radiosensitizing effects. In this study we screened the response to X-ray or proton radiation in cell lines treated with DDR inhibitors (DDRis) targeting ATM, ATR, DNA-PKcs, Rad51, and PARP, with survival metrics established using clonogenic assays. We observed that DDRis generate significant radiosensitization in cancer and primary cells derived from normal tissue. Existing genetic defects in cancer cells appear to be an important consideration when determining the optimal inhibitor to use for synergistic combination with radiation. We also show that while greater radiosensitization can be achieved with protons (9.9 keV/µm) combined with DDRis, the relative biological effectiveness is unchanged or in some cases reduced. Our results indicate that while targeting the DDR can significantly radiosensitize cancer cells to such combinations, normal cells may also be equally or more severely affected, depending on the DDRi used. These data highlight the importance of identifying genetic defects as predictive biomarkers of response for combination treatment.


Assuntos
Neoplasias , Radiossensibilizantes , Proteínas Mutadas de Ataxia Telangiectasia/metabolismo , DNA , Dano ao DNA , Reparo do DNA , Humanos , Neoplasias/tratamento farmacológico , Inibidores de Poli(ADP-Ribose) Polimerases/farmacologia , Inibidores de Poli(ADP-Ribose) Polimerases/uso terapêutico , Prótons , Rad51 Recombinase/metabolismo , Radiossensibilizantes/farmacologia , Raios X
10.
Clin Colorectal Cancer ; 21(3): 204-211, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35125321

RESUMO

BACKGROUND: Short course radiation-based total neoadjuvant therapy can improve disease-free survival for patients with high-risk locally advanced rectal cancer. Tumors that involve or threaten the circumferential resection margin have a particularly high risk of local recurrence. Intraoperative radiation therapy enables treatment escalation at the threatened or involved margin at the time of surgery. PATIENTS AND METHODS: Patients with rectal adenocarcinoma treated with preoperative short course radiotherapy-based total neoadjuvant therapy and intraoperative radiation at the time of surgery were identified. All patients had a threatened or involved circumferential resection margin on magnetic resonance imaging at the time of diagnosis. Treatment details, radiation toxicities, postoperative complications and oncologic outcomes were recorded. RESULTS: Ten patients received intraoperative radiation after short course radiation-based total neoadjuvant therapy. All patients had an involved or threatened circumferential resection margin, 60% had extramural venous invasion, and 60% had positive lateral pelvic lymph nodes. Seven patients had negative surgical margins (≥ 2 mm), and 3 patients had an R1 resection with radial margins < 2 mm. The median [IQR] length of hospitalization after surgery was 11 [7-14] days. Three patients required readmission and 2 patients required reoperation due to complications including anastamotic leak and abscess. With a median follow up of 19.5 months postoperatively, no patient developed a pelvic recurrence, and 6 patients developed distant recurrences. CONCLUSIONS: The use of intraoperative radiation after a short course radiotherapy-based neoadjuvant therapy is safe and feasible. Further data are needed to determine whether the addition of intraoperative radiation improves local recurrence rates over preoperative radiation alone.


Assuntos
Adenocarcinoma , Neoplasias Retais , Adenocarcinoma/patologia , Humanos , Margens de Excisão , Terapia Neoadjuvante/efeitos adversos , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Neoplasias Retais/patologia , Estudos Retrospectivos
11.
Int J Radiat Oncol Biol Phys ; 112(2): 426-436, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34610390

RESUMO

PURPOSE: BRCA1/2 pathogenic variant (PV) mutations confer radiation sensitivity preclinically, but there are limited data regarding breast cancer outcomes after radiation therapy (RT) among patients with documented BRCA1/2 PV mutations versus no PV mutations. METHODS AND MATERIALS: This retrospective cohort study included women with clinical stage I-III breast cancer who received definitive surgery and RT and underwent BRCA1/2 genetic evaluation at the The University of Texas MD Anderson Cancer Center. Rates of locoregional recurrence (LRR), disease-specific death (DSD), toxicities, and second cancers were compared by BRCA1/2 PV status. RESULTS: Of the 2213 women who underwent BRCA1/2 testing, 63% self-reported their race as White, 13.6% as Black/African American, 17.6% as Hispanic, and 5.8% as Asian/American Indian/Alaska Native; 124 had BRCA1 and 100 had BRCA2 mutations; and 1394 (63%) received regional nodal RT. The median follow-up time for all patients was 7.4 years (95% confidence interval [CI], 7.1-7.7 years). No differences were found between the groups with and without BRCA1/2 PV mutations in 10-year cumulative incidences of LRR (with mutations: 11.6% [95% CI, 7.0%-17.6%]; without mutations: 6.6% [95% CI, 5.3%-8.0%]; P = .466) and DSD (with mutations: 12.3% [95% CI, 8.0%-17.7%]; without mutations: 13.8% [95% CI, 12.0%-15.8%]; P = .716). On multivariable analysis, BRCA1/2 status was not associated with LRR or DSD, but Black/African American patients (P = .036) and Asians/American Indians/Alaska Native patients (P = .002) were at higher risk of LRR compared with White patients, and Black/African American patients were at higher risk of DSD versus White patients (P = .004). No in-field, nonbreast second cancers were observed in the BRCA1/2 PV group. Rates of acute and late grade ≥3 radiation-related toxicity in the BCRA1/2 PV group were 5.4% (n = 12) and 0.4% (n = 1), respectively. CONCLUSIONS: Oncologic outcomes in a diverse cohort of patients with breast cancer who had a germline BRCA1/2 PV mutation and were treated with RT were similar to those of patients with no mutation, supporting the use of RT according to standard indications in patients with a germline BRCA1/2 PV mutation.


Assuntos
Neoplasias da Mama , Recidiva Local de Neoplasia , Proteína BRCA1/genética , Neoplasias da Mama/genética , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Feminino , Células Germinativas/patologia , Mutação em Linhagem Germinativa , Humanos , Mutação , Recidiva Local de Neoplasia/genética , Estudos Retrospectivos
12.
Int J Radiat Oncol Biol Phys ; 112(2): 437-444, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34582940

RESUMO

PURPOSE: Multigene panel testing has increased the detection of germline mutations in patients with breast cancer. The implications of using radiation therapy (RT) to treat patients with pathogenic variant (PV) mutations are not well understood and have been studied mostly in women with only BRCA1 or BRCA2 PVs. We analyzed oncologic outcomes and toxicity after adjuvant RT in a contemporary, diverse cohort of patients with breast cancer who underwent genetic panel testing. METHODS AND MATERIALS: We retrospectively reviewed the records of 286 women with clinical stage I-III breast cancer diagnosed from 1995 to 2017 who underwent surgery, breast or chest wall RT with or without regional nodal irradiation, multigene panel testing, and evaluation at a large cancer center's genetic screening program. We evaluated rates of overall survival, locoregional recurrence, disease-specific death, and radiation-related toxicities in 3 groups: BRCA1/2 PV carriers, non-BRCA1/2 PV carriers, and patients without PV mutations. RESULTS: PVs were detected in 25.2% of the cohort (12.6% BRCA1/2 and 12.6% non-BRCA1/2). The most commonly detected non-BRCA1/2 mutated genes were ATM, CHEK2, PALB2, CDH1, TP53, and PTEN. The median follow-up time for the entire cohort was 4.4 years (95% confidence interval, 3.8-4.9 years). No differences were found in overall survival, locoregional recurrence, or disease-specific death between groups (P > .1 for all). Acute and late toxicities were comparable across groups. CONCLUSION: Oncologic and toxicity outcomes after RT in women with PV germline mutations detected by multigene pane testing are similar to those in patients without detectable mutations, supporting the use of adjuvant RT as a standard of care when indicated.


Assuntos
Neoplasias da Mama , Mutação em Linhagem Germinativa , Proteína BRCA1/genética , Neoplasias da Mama/genética , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Genes BRCA2 , Predisposição Genética para Doença , Mutação em Linhagem Germinativa/genética , Humanos , Recidiva Local de Neoplasia/genética , Estudos Retrospectivos , Resultado do Tratamento
13.
Med Phys ; 48(6): 3243-3261, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33837540

RESUMO

PURPOSE: To show that intrinsic radiosensitivity varies greatly for protons and carbon (C) ions in addition to photons, and that DNA repair capacity remains important in governing this variability. METHODS: We measured or obtained from the literature clonogenic survival data for a number of human cancer cell lines exposed to photons, protons (9.9 keV/µm), and C-ions (13.3-77.1 keV/µm). We characterized their intrinsic radiosensitivity by the dose for 10% or 50% survival (D10% or D50% ), and quantified the variability at each radiation quality by the coefficient of variation (COV) in D10% and D50% . We also treated cells with DNA repair inhibitors prior to irradiation to assess how DNA repair capacity affects their variability. RESULTS: We found no statistically significant differences in the COVs of D10% or D50% between any of the radiation qualities investigated. The same was true regardless of whether the cells were treated with DNA repair inhibitors, or whether they were stratified into histologic subsets. Even within histologic subsets, we found remarkable differences in radiosensitivity for high LET C-ions that were often greater than the variations in RBE, with brain cancer cells varying in D10% (D50% ) up to 100% (131%) for 77.1 keV/µm C-ions, and non-small cell lung cancer and pancreatic cancer cell lines varying up to 55% (76%) and 51% (78%), respectively, for 60.5 keV/µm C-ions. The cell lines with modulated DNA repair capacity had greater variability in intrinsic radiosensitivity across all radiation qualities. CONCLUSIONS: Even for cell lines of the same histologic type, there are remarkable variations in intrinsic radiosensitivity, and these variations do not differ significantly between photon, proton or C-ion radiation. The importance of DNA repair capacity in governing the variability in intrinsic radiosensitivity is not significantly diminished for higher LET radiation.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carbono , Linhagem Celular , Sobrevivência Celular , Humanos , Prótons , Tolerância a Radiação , Eficiência Biológica Relativa
14.
Int J Radiat Oncol Biol Phys ; 111(5): 1298-1309, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34400267

RESUMO

PURPOSE: To estimate the effects of interfractional anatomic changes on dose to organs at risk (OARs) and tumors, as measured with cone beam computed tomography (CBCT) image guidance for pancreatic stereotactic body radiation therapy. METHODS AND MATERIALS: We evaluated 11 patients with pancreatic cancer whom were treated with stereotactic body radiation therapy (33-40 Gy in 5 fractions) using daily CT-on-rails (CTOR) image guidance immediately before treatment with breath-hold motion management. CBCT alignment was simulated in the treatment planning software by aligning the original planning CT to each fractional CTOR image set via fiducial markers. CTOR data sets were used to calculate fractional doses after alignment by applying the rigid shift of the planning CT and CTOR image sets to the planning treatment isocenter and recalculating the fractional dose. Accumulated dose to the gross tumor volume (GTV), tumor vessel interface, duodenum, small bowel, and stomach were calculated by summing the 5 fractional absolute dose-volume histograms into a single dose-volume histogram for comparison with the original planned dose. RESULTS: Four patients had a GTV D100% of at least 1.5 Gy less than the fractional planned value in several fractions; 4 patients had fractional underestimation of duodenum dose by 1.0 Gy per fraction. The D1.0 cm3 <35 Gy constraint was violated for at least 1 OAR in 3 patients, with either the duodenum (n = 2) or small bowel (n = 1) D1.0 cm3 being higher on the accumulated dose distribution (P = .01). D100% was significantly lower according to accumulated dose GTV (P = .01) and tumor vessel interface (P = .02), with 4 and 2 patients having accumulated D100%  ≥4 Gy lower than the planned value for the GTV and tumor vessel interface, respectively. CONCLUSIONS: For some patients, CBCT image guidance based on fiducial alignment may cause large dosimetric uncertainties for OARs and target structures, according to accumulated dose.


Assuntos
Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Humanos , Pâncreas , Radiometria , Dosagem Radioterapêutica
15.
Phys Med Biol ; 66(5)2021 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-33227715

RESUMO

The treatment of cancer with proton radiation therapy was first suggested in 1946 followed by the first treatments in the 1950s. As of 2020, almost 200 000 patients have been treated with proton beams worldwide and the number of operating proton therapy (PT) facilities will soon reach one hundred. PT has long moved from research institutions into hospital-based facilities that are increasingly being utilized with workflows similar to conventional radiation therapy. While PT has become mainstream and has established itself as a treatment option for many cancers, it is still an area of active research for various reasons: the advanced dose shaping capabilities of PT cause susceptibility to uncertainties, the high degrees of freedom in dose delivery offer room for further improvements, the limited experience and understanding of optimizing pencil beam scanning, and the biological effect difference compared to photon radiation. In addition to these challenges and opportunities currently being investigated, there is an economic aspect because PT treatments are, on average, still more expensive compared to conventional photon based treatment options. This roadmap highlights the current state and future direction in PT categorized into four different themes, 'improving efficiency', 'improving planning and delivery', 'improving imaging', and 'improving patient selection'.


Assuntos
Neoplasias , Terapia com Prótons , Biologia , Humanos , Neoplasias/radioterapia , Fótons , Física , Terapia com Prótons/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
16.
Med Phys ; 37(9): 4960-70, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20964215

RESUMO

PURPOSE: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. METHODS: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. RESULTS: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. CONCLUSIONS: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.


Assuntos
Método de Monte Carlo , Terapia com Prótons , Radioterapia/métodos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
17.
Med Phys ; 37(1): 154-63, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20175477

RESUMO

PURPOSE: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). METHODS: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm2 and over a maximum scan area at the isocenter of 30 x 30 cm2. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. RESULTS: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. CONCLUSIONS: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.


Assuntos
Aceleradores de Partículas/instrumentação , Terapia com Prótons , Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Dosagem Radioterapêutica , Integração de Sistemas , Texas
18.
Med Phys ; 47(2): e19-e51, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31574174

RESUMO

Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters (OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescence dosimetry in a clinical setting. This includes: (a) to review the variety of TLD/OSLD materials available, including features and limitations of each; (b) to outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used; (c) to develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice; and (d) to develop guidelines for special medically relevant uses of TLDs/OSLDs such as mixed photon/neutron field dosimetry, particle beam dosimetry, and skin dosimetry. While this report provides general guidelines for TLD and OSLD processes, the report provides specific details for TLD-100 and nanoDotTM dosimeters because of their prevalence in clinical practice.


Assuntos
Equipamentos e Provisões/normas , Dosimetria por Luminescência Estimulada Opticamente/métodos , Dosimetria por Luminescência Estimulada Opticamente/normas , Dosimetria Termoluminescente/métodos , Dosimetria Termoluminescente/normas , Calibragem , Guias como Assunto , Humanos , Luminescência , Modelos Teóricos , Nêutrons , Fótons , Tecnologia de Sensoriamento Remoto , Reprodutibilidade dos Testes
19.
Med Phys ; 47(1): 272-281, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31677156

RESUMO

PURPOSE: High energetic carbon (C-) ion beams undergo nuclear interactions with tissue, producing secondary nuclear fragments. Thus, at depth, C-ion beams are composed of a mixture of different particles with different linear energy transfer (LET) values. We developed a technique to enable isolation of DNA damage response (DDR) in mixed radiation fields using beam line microscopy coupled with fluorescence nuclear track detectors (FNTDs). METHODS: We imaged live cells on a coverslip made of FNTDs right after C-ion, proton or photon irradiation using an in-house built confocal microscope placed in the beam path. We used the FNTD to link track traversals with DNA damage and separated DNA damage induced by primary particles from fragments. RESULTS: We were able to spatially link physical parameters of radiation tracks to DDR in live cells to investigate spatiotemporal DDR in multi-ion radiation fields in real time, which was previously not possible. We demonstrated that the response of lesions produced by the high-LET primary particles associates most strongly with cell death in a multi-LET radiation field, and that this association is not seen when analyzing radiation induced foci in aggregate without primary/fragment classification. CONCLUSIONS: We report a new method that uses confocal microscopy in combination with FNTDs to provide submicrometer spatial-resolution measurements of radiation tracks in live cells. Our method facilitates expansion of the radiation-induced DDR research because it can be used in any particle beam line including particle therapy beam lines. CATEGORY: Biological Physics and Response Prediction.


Assuntos
Carbono , Dano ao DNA , Corantes Fluorescentes/metabolismo , Transferência Linear de Energia , Linhagem Celular Tumoral , Sobrevivência Celular , Humanos , Imagem Molecular , Fatores de Tempo
20.
Radiat Res ; 171(2): 225-35, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19267549

RESUMO

Space radiation hazards are recognized as a key concern for human space flight. For long-term interplanetary missions, they constitute a potentially limiting factor since current protection limits for low-Earth orbit missions may be approached or even exceeded. In such a situation, an accurate risk assessment requires knowledge of equivalent doses in critical radiosensitive organs rather than only skin doses or ambient doses from area monitoring. To achieve this, the MATROSHKA experiment uses a human phantom torso equipped with dedicated detector systems. We measured for the first time the doses from the diverse components of ionizing space radiation at the surface and at different locations inside the phantom positioned outside the International Space Station, thereby simulating an extravehicular activity of an astronaut. The relationships between the skin and organ absorbed doses obtained in such an exposure show a steep gradient between the doses in the uppermost layer of the skin and the deep organs with a ratio close to 20. This decrease due to the body self-shielding and a concomitant increase of the radiation quality factor by 1.7 highlight the complexities of an adequate dosimetry of space radiation. The depth-dose distributions established by MATROSHKA serve as benchmarks for space radiation models and radiation transport calculations that are needed for mission planning.


Assuntos
Radiação Cósmica , Modelos Anatômicos , Voo Espacial , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA