Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr Orthop ; 35(8): e93-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25985374

RESUMO

BACKGROUND: Good outcomes have been described for pediatric lateral condyle fractures treated by open reduction and fixation using either screws or Kirschner wires (K-wires). No studies have compared the biomechanical properties of the 2 fixation methods. We hypothesized that screw fixation would be more biomechanically stable than K-wire fixation. METHODS: Synthetic humerus models were used for biomechanical testing, following a previously published protocol. A miter saw was used to make an oblique cut to simulate a Milch type II fracture. Fractures were anatomically reduced and fixed with either 2 divergent 0.062-inch K-wires placed bicortically or a 4.0-mm lag screw placed obliquely (perpendicular to the fracture line). Specimens were then embedded in polymethyl methacrylate bone cement for testing. Mechanical testing using displacement control was performed applying compression or distraction from 0 to 1.5 mm at a rate of 0.5 mm/s for 10 cycles. The maximum force was calculated based on the maximum force averaged over the 10 cycles. Stiffness was calculated based on the slope of the force-displacement curve of the 10th cycle. A 2-sample t test was used to determine significant differences between the stiffness and maximum force comparing the K-wire and screw groups. A P-value of <0.05 was considered statistically significant. RESULTS: Stiffness and maximum force in tension testing were significantly greater with screw fixation compared with K-wire fixation. Testing in compression revealed statistically significant increased maximum force and a trend towards increased stiffness. CONCLUSION: Screw fixation in a synthetic bone model of pediatric lateral condyle fractures (Milch type II) provides increased biomechanical stability of the construct as compared with K-wires. CLINICAL RELEVANCE: If similar effects were seen in vivo, increased biomechanical stability with screw fixation could decrease the occurrence of complications such as loss of reduction and nonunion.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas/instrumentação , Fraturas do Úmero/cirurgia , Úmero , Fenômenos Biomecânicos , Criança , Articulação do Cotovelo/cirurgia , Fixação Interna de Fraturas/métodos , Humanos , Úmero/lesões , Úmero/cirurgia , Modelos Anatômicos , Lesões no Cotovelo
2.
J Pediatr Orthop B ; 25(2): 148-52, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26583930

RESUMO

Good results have been described for lateral condyle fractures treated by open reduction and fixation using Kirschner wires or screws. We, in our level III retrospective comparison clinical research study, retrospectively reviewed 84 patients (43 K-wire, 41 screw fixation; average age 5.6 years, average follow-up 6.8 months). With K-wires there were three nonunions (average time to union 9.6 weeks). With screws, all fractures healed (average of 7.8 weeks). Screw fixation patients spent fewer days in a cast and had a greater range of motion at the last follow-up. Screw fixation is associated with fewer nonunions and faster time to union, but a secondary procedure for removal is required.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas do Úmero/cirurgia , Adolescente , Moldes Cirúrgicos , Criança , Pré-Escolar , Feminino , Seguimentos , Consolidação da Fratura , Humanos , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA