Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Radiol ; 33(3): 1698-1706, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36271920

RESUMO

OBJECTIVES: To evaluate the feasibility of Doppler-ultrasound (DUS)-gated 4D flow MRI of the fetal great thoracic vessels at 3T in a clinical setting. METHODS: Sixteen consecutive fetuses (range 30+4-38+5 weeks) with (n = 11) and without (n = 5) cardiovascular anomalies underwent 4D flow MRI of the great thoracic vessels at 3T. Direct fetal cardiac gating was obtained using a MR-compatible DUS device. 4D flow MRI-based visualisation and quantification of four target regions (ascending aorta (AAo), descending aorta (DAo), main pulmonary artery (MPA), and ductus arteriosus (DA)) were performed using dedicated software. RESULTS: Fetal 4D flow MRI of the great thoracic vessels was successful in 12/16 fetuses (75%) by adopting clinical 4D flow MR protocols in combination with direct fetal cardiac DUS-gating. Four datasets were excluded due to artefacts by fetal movement or maternal breathing. 4D flow MRI-derived time-velocity curves revealed typical arterial blood flow patterns in the aorta. 4D flow quantification was achieved for the pre-defined target regions. Average velocity and flow volume were 21.1 ± 5.2 cm/s and 6.0 ± 3.1 mL/s in the AAo, 24.3 ± 6.7 cm/s and 8.4 ± 3.7 mL/s in the DAo, 21.9 ± 6.4 cm/s and 7.8 ± 4.2 mL/s in the MPA, and 23.4 ± 4.7 cm/s and 5.9 ± 3.6 mL/s in the DA, respectively. CONCLUSIONS: Combination of DUS-gating of the fetal heart and 4D flow MRI allows comprehensive visualisation and quantification of haemodynamics in the fetal great thoracic vessels. DUS-gated fetal 4D flow MRI may provide a new diagnostic approach for prenatal assessment of blood flow haemodynamics. KEY POINTS: • Fetal cardiac Doppler-ultrasound (DUS) gating and 4D flow MRI can be successfully combined. • DUS-gated fetal 4D flow MRI allowed visualisation and evaluation of streamline directionality, illustration of blood flow variations, and pulsatile arterial waveforms in the target vessels. • 4D flow MRI-based visualisation and quantification of the fetal great thoracic vessels were successful and flow metrics agreed with echocardiographic reference values.


Assuntos
Coração Fetal , Imageamento por Ressonância Magnética , Gravidez , Feminino , Humanos , Estudos de Viabilidade , Idade Gestacional , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiologia , Artéria Pulmonar/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Aorta Torácica
2.
Eur Radiol ; 29(8): 4169-4176, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30617486

RESUMO

OBJECTIVES: To investigate the feasibility of fetal phase-contrast (PC)-MR angiography of the descending aorta (AoD) using an MR-compatible Doppler ultrasound sensor (DUS) for fetal cardiac gating and to compare velocimetry with Doppler ultrasound measurements. METHODS: In this prospective study, 2D PC-MR angiography was performed in 12 human fetuses (mean gestational age 32.8 weeks) using an MR-compatible DUS for gating of the fetal heart at 1.5 T. Peak flow velocities in the fetal AoD were compared with Doppler ultrasound measurements performed on the same day. Reproducibility of PC-MR measurements was tested by repeated PC-MR in five fetuses. RESULTS: Dynamic PC-MR angiography in the AoD was successfully performed in all fetuses using the DUS, with an average fetal heart rate of 140 bpm (range 129-163). Time-velocity curves revealed typical arterial blood flow patterns. PC-MR mean flow velocity and mean flux were 21.2 cm/s (range 8.6-36.8) and 8.4 ml/s (range 3.2-14.6), respectively. A positive association between PC-MR mean flux and stroke volume with gestational age was obtained (r = 0.66, p = 0.02 and r = 0.63, p = 0.03). PC-MR and Doppler ultrasound peak velocities revealed a highly significant correlation (r = 0.8, p < 0.002). Peak velocities were lower for PC-MR with 69.1 cm/s (range 39-125) compared with 96.7 cm/s (range 60-142) for Doppler ultrasound (p < 0.001). Reproducibility of PC-MR was high (p > 0.05). CONCLUSION: The MR-compatible DUS for fetal cardiac gating allows for PC-MR angiography in the fetal AoD. Comparison with Doppler ultrasound revealed a highly significant correlation of peak velocities with underestimation of PC-MR velocities. This new technique for direct fetal cardiac gating indicates the potential of PC-MR angiography for assessing fetal hemodynamics. KEY POINTS: • The developed MR-compatible Doppler ultrasound sensor allows direct fetal cardiac gating and can be used for prenatal dynamic cardiovascular MRI. • The MR-compatible Doppler ultrasound sensor was successfully applied to perform intrauterine phase-contrast MR angiography of the fetal aorta, which revealed a highly significant correlation with Doppler ultrasound measurements. • As fetal flow hemodynamics is an important parameter in the diagnosis and management of fetal pathologies, fetal phase-contrast MR angiography may offer an alternative imaging method in addition to Doppler ultrasound and develop as a second line tool in the evaluation of fetal flow hemodynamics.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Feto/fisiologia , Angiografia por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Adulto , Artérias/embriologia , Artérias/fisiologia , Feminino , Sangue Fetal/fisiologia , Idade Gestacional , Humanos , Angiografia por Ressonância Magnética/normas , Idade Materna , Microscopia de Contraste de Fase/métodos , Gravidez , Diagnóstico Pré-Natal/normas , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos
3.
Ultrasound Obstet Gynecol ; 53(5): 669-675, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30381848

RESUMO

OBJECTIVES: To investigate the diagnostic performance of dynamic fetal cardiac magnetic resonance imaging (MRI), using a MR-compatible Doppler ultrasound (DUS) device for fetal cardiac gating, in differentiating fetuses with congenital heart disease from those with a normal heart, and to compare the technique with fetal echocardiography. METHODS: This was a prospective study of eight fetuses with a normal heart and four with congenital heart disease (CHD), at a median of 34 (range, 28-36) weeks' gestation. Dynamic fetal cardiac MRI was performed using a DUS device for direct cardiac gating. The four-chamber view was evaluated according to qualitative findings. Measurements of the length of the left and right ventricles, diameter of the tricuspid and mitral valves, myocardial wall thickness, transverse cardiac diameter and left ventricular planimetry were performed. Fetal echocardiography and postnatal diagnoses were considered the reference standards. RESULTS: Direct cardiac gating allowed continuous triggering of the fetal heart, showing high temporal and spatial resolution. Both fetal cardiac MRI and echocardiography in the four-chamber view detected pathological findings in three of the 12 fetuses. Qualitative evaluation revealed overall consistency between echocardiography and MRI. On both echocardiography and MRI, quantitative measurements revealed significant differences between fetuses with a normal heart and those with CHD with respect to the length of the right (P < 0.01 for both) and left (P < 0.01 for both) ventricles and transverse cardiac diameter (P < 0.05 and P < 0.01, respectively). Tricuspid valve diameter on cardiac MRI was found to be significantly different in healthy fetuses from in those with CHD (P < 0.05). CONCLUSIONS: For the first time, this study has shown that dynamic fetal cardiac MRI in the four-chamber view, using external cardiac gating, allows evaluation of cardiac anatomy and diagnosis of congenital heart disease in agreement with fetal echocardiography. Dynamic fetal cardiac MRI may be useful as a second-line investigation if conditions for fetal echocardiography are unfavorable. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Ecocardiografia Doppler/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Angiografia por Ressonância Magnética/estatística & dados numéricos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto , Ecocardiografia Doppler/métodos , Feminino , Idade Gestacional , Cardiopatias Congênitas/embriologia , Testes de Função Cardíaca/métodos , Testes de Função Cardíaca/estatística & dados numéricos , Humanos , Angiografia por Ressonância Magnética/métodos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/métodos , Adulto Jovem
4.
Eur J Radiol ; 83(10): 1856-61, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25043987

RESUMO

OBJECTIVES: To determine cut-off values and the accuracy of plain film measurements for the detection of isolated syndesmotic injury after acute ankle trauma and to investigate MRI findings of concomitant ankle injury. METHODS: Eighty-four consecutive patients with absent fracture in plain film radiographs were prospectively evaluated for isolated syndesmotic injury after acute ankle trauma. The tibiofibular clear space (TFCS), the tibiofibular overlap (TFO), and the medial clear space (MCS) were independently assessed in plain radiographs by two readers. MRI performed at 3T within 24h served as the reference standard. MRI was evaluated for syndesmotic injury, using a four-scale grading system (0=normal syndesmosis, 1a=periligamentous edema, 1b=intraligamentous edema, 2=partial rupture, 3=complete rupture), and for concomitant ankle injury. Inter-observer variability for x-ray measurements was assessed using Bland-Altman diagrams. ROC analyses were performed to determine cut-off values and sensitivity and specificity for TFCS, TFO, and MCS. RESULTS: Eleven of 84 patients (13.1%) revealed syndesmotic injury (Grade 2 or 3) according to MRI. Between patients with and without syndesmotic injury significantly different measurements were obtained for TFCS (p=0.003) and MCS (p=0.04). ROC derived cut-off values were 5.3mm for TFCS, 2.8mm for TFO, and 2.8mm for MCS. Sensitivity and specificity was 82% and 75% for TFCS, 36% and 78% for TFO, and 73% and 59% for MCS. The bias and limits of agreement were -0.04 mm and [-1.54; 1.53] for TFCS, 0.8mm and [-2.5; 2.5] for TFO, and 0.05 mm and [-1.42; 1.43] for MCS. Patients with syndesmotic injury had a 5-fold increased risk of concomitant ankle injury (p=0.07). CONCLUSIONS: The determined cut-off values aid in the evaluation of syndesmotic integrity in patients with absent fracture in plain radiographs. In case of increased distances MRI is recommended to assess severity of SI and to reveal associated ankle injuries.


Assuntos
Traumatismos do Tornozelo/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Traumatismos do Tornozelo/diagnóstico por imagem , Edema/diagnóstico , Feminino , Humanos , Masculino , Estudos Prospectivos , Radiografia , Ruptura/diagnóstico , Sensibilidade e Especificidade
5.
Eur J Radiol ; 82(8): 1273-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23422283

RESUMO

OBJECTIVES: To investigate the accuracy of biplane radiography in the detection of fractures of the thoracic spine in patients with minor trauma using multidetector computed tomography (MDCT) as the reference and to compare the dose of both techniques. METHODS: 107 consecutive trauma patients with suspected fractures of the thoracic spine on physical examination were included. All had undergone biplane radiography first, followed by a MDCT scan between October 2008 and October 2012. A fourfold table was used for the classification of the screening test results. Both the Chi-square test (χ(2)) and the mean dose-length product (DLP) were used to compare the diagnostic methods. RESULTS: MDCT revealed 77 fractures in 65/107 patients (60.7%). Biplane radiography was true positive in 32/107 patients (29.9%), false positive in 19/107 patients (17.8%), true negative in 23/107 (21.5%) and false negative in 33/107 patients (30.8%), showing a sensitivity of 49.2%, a specificity of 54.7%, a positive predictive value (PPV) of 62.7%, a negative predictive value (NPV) of 41.1%, and an accuracy of 51.4%. The presence of a fracture on biplane radiography was highly statistical significant, if this was simultaneously proven by MDCT (χ(2)=7.6; p=0.01). None of the fractures missed on biplane radiography was unstable. The mean DLP on biplane radiography was 14.5mGycm (range 1.9-97.8) and on MDCT 374.6mGycm (range 80.2-871). CONCLUSIONS: The sensitivity and the specificity of biplane radiography in the diagnosis of fractures of the thoracic spine in patients with minor trauma are low. Considering the wide availability of MDCT that is usually necessary for taking significant therapeutic steps, the indication for biplane radiography should be very restrictive.


Assuntos
Doses de Radiação , Traumatismos da Coluna Vertebral/epidemiologia , Traumatismos da Coluna Vertebral/patologia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Índices de Gravidade do Trauma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA