Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
J Radiol Prot ; 39(4): R37-R50, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31307030

RESUMO

This paper provides a summary of the Education and Training (E&T) activities that have been developed and organised by the European Radiation Dosimetry Group (EURADOS) in recent years and in the case of Training Courses over the last decade. These E&T actions include short duration Training Courses on well-established topics organised within the activity of EURADOS Working Groups (WGs), or one-day events integrated in the EURADOS Annual Meeting (workshops, winter schools, the intercomparison participants' sessions and the learning network, among others). Moreover, EURADOS has recently established a Young Scientist Grant and a Young Scientist Award. The Grant supports young scientists by encouraging them to perform research projects at other laboratories of the EURADOS network. The Award is given in recognition of excellent work developed within the WGs' work programme. Additionally, EURADOS supports the dissemination of knowledge in radiation dosimetry by promoting and endorsing conferences such as the individual monitoring (IM) series, the neutron and ion dosimetry symposia (NEUDOS) and contributions to E&T sessions at specific events.

2.
Radiat Prot Dosimetry ; 126(1-4): 482-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17496297

RESUMO

In neutron reference radiation fields, the conventional true value of the personal dose equivalent, H(p)(10), is derived from the spectral neutron fluence and recommended conversion coefficients. This procedure requires the phantom on which the personal dosemeter is mounted to be irradiated with a broad and parallel beam. In many practical situations, the change of the neutron fluence and/or the energy distribution over the surface of the phantom may not be neglected. For a selection of typical irradiation conditions in neutron reference radiation fields, the influence of this effect has been analysed using numerical methods. A further problem, which is of relevance for the calibration of dosemeters measuring both the neutron and the photon component of mixed fields, is the 'double counting' of the dose equivalent due to neutron-induced photons. The relevance of this conceptual problem for calibrations in mixed-field dosimetry was analysed.


Assuntos
Artefatos , Nêutrons , Fótons , Proteção Radiológica/instrumentação , Proteção Radiológica/normas , Radiometria/instrumentação , Radiometria/normas , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Alemanha , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Radiat Prot Dosimetry ; 125(1-4): 61-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18334544

RESUMO

Within its occupational radiation protection programme, the International Atomic Energy Agency (IAEA) initiated and funded an international intercomparison exercise of personal dosemeters to determine the quantity personal dose equivalent in mixed neutron-photon radiation. The objectives of the intercomparison are to assess the capabilities of the dosimetry services in measuring the quantity Hp(10) in mixed neutron-gamma fields; to assist IAEA member states in achieving sufficiently accurate dosimetry; and, if necessary, to provide guidelines for improvements (not simply a test of the performance of the existing dosimetry service). The intercomparison is directed to passive dosemeters to determine, in mixed neutron-gamma radiation fields, either these two components separately or the total personal dose equivalent. The intercomparison consists of two phases: Phase I--Type-test intercomparison: irradiation in selected calibration fields and results used to improve dosimetric procedures of participating laboratories, where needed. Phase II--Simulated workplace field intercomparison: irradiation in radiation fields similar to those in workplaces as a final check of performance. The exercise revealed clear deficiencies in the methodology used by several laboratories and necessitated a detailed analysis of the existing discrepancies. This papers summaries the finding and conclusions for radiation fields similar to those found in nuclear industry.


Assuntos
Carga Corporal (Radioterapia) , Exposição Ocupacional/análise , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Medição de Risco/normas , Europa (Continente) , Raios gama , Humanos , Internacionalidade , Nêutrons , Exposição Ocupacional/prevenção & controle , Controle de Qualidade , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Radiat Prot Dosimetry ; 124(3): 219-29, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17890781

RESUMO

Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional Bonner sphere spectrometry and newly developed direction spectrometers. The results of the analysis, using Bayesian parameter estimation methods and different unfolding codes, some of them especially adapted to simultaneously unfold energy and direction distributions of the neutron fluence, showed that neutron spectra differed strongly at the different places, both in energy and direction distribution. The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discussed.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Monitoramento de Radiação/métodos , Análise Espectral/instrumentação , União Europeia , Humanos , Análise Espectral/métodos , Local de Trabalho
5.
Radiat Prot Dosimetry ; 125(1-4): 281-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17314086

RESUMO

The paper presents the main conclusions and recommendations derived from the EVIDOS project, which is supported by the European Commission within the 5th Framework Programme. EVIDOS aims at evaluating state of the art neutron dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This analysis complements a series of individual papers which present detailed results and it summarises the main findings from a practical point of view. Conclusions and recommendations are given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosemeter results.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , União Europeia , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Radiat Prot Dosimetry ; 125(1-4): 364-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17369265

RESUMO

Within the EC project EVIDOS, double-differential (energy and direction) fluence spectra were determined by means of novel direction spectrometers. By folding the spectra with fluence-to-dose equivalent conversion coefficients, contributions to H*(10) for 14 directions, and values of the personal dose equivalent Hp(10) and the effective dose E for 6 directions of a person's orientation in the field were determined. The results of the measurements and calculations obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e., at Krümmel (boiling water reactor and transport cask), at Mol (Venus research reactor and fuel facility Belgonucléaire) and at Ringhals (pressurised reactor and transport cask) are presented.


Assuntos
Carga Corporal (Radioterapia) , Modelos Biológicos , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Internacionalidade , Nêutrons , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Radiat Prot Dosimetry ; 125(1-4): 275-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17522043

RESUMO

Supported by the European Commission, the EVIDOS project started in November 2001 with the broad goal of evaluating state of the art dosimetry techniques in representative workplaces of the nuclear industry. Seven European institutes joined efforts with end users at nuclear power plants, at fuel processing and reprocessing plants, and at transport and storage facilities. A comprehensive programme was devised to evaluate capabilities and limitations of standard and innovative personal dosemeters in relation to the mixed neutron-photon fields of concern to the nuclear industry. This paper describes the criteria behind the selection of dosimetry techniques and workplaces that were analysed, as well as the organisation of the measurement campaigns. Particular emphasis was placed on the evaluation of a variety of electronic personal dosemeters, either commercially available or previously developed by the partners. The estimates provided by these personal dosemeters were compared to reference values of dose equivalent quantities derived from spectrometry and fluence-to-dose equivalent conversion coefficients. Spectrometry was performed both with conventional multisphere and with some original instrumentation providing energy and direction resolution, based on silicon detectors and superheated drop detectors mounted on or in spherical moderators. The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europe.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , União Europeia , Internacionalidade , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Radiat Prot Dosimetry ; 126(1-4): 471-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17823130

RESUMO

The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those fields.


Assuntos
Ciclotrons , Modelos Biológicos , Nêutrons , Exposição Ocupacional/análise , Radiometria/métodos , Radiometria/tendências , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Masculino , Modelos Estatísticos , Doses de Radiação , Espanha
9.
Radiat Prot Dosimetry ; 125(1-4): 293-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17449908

RESUMO

Within the EC project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'), different types of active neutron personal dosemeters (and some passive ones) were tested in workplace fields at nuclear installations in Europe. The results of the measurements which have been performed up to now are summarised and compared to our currently best estimates of the personal dose equivalent Hp(10). Under- and over-readings by more than a factor of two for the same dosemeter in different workplace fields indicate that in most cases the use of field-specific correction factors is required.


Assuntos
Desenho Assistido por Computador , Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Programas Governamentais , Internacionalidade , Nêutrons , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Radiat Prot Dosimetry ; 124(3): 213-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17893081

RESUMO

Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H(p)(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Doses de Radiação , Monitoramento de Radiação/métodos , União Europeia , Humanos , Proteção Radiológica/métodos , Medição de Risco , Local de Trabalho
11.
Radiat Prot Dosimetry ; 125(1-4): 300-3, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17846030

RESUMO

Neutron survey instruments have been exposed at all the measurement locations used in the EVIDOS project. These results have an important impact in the interpretation of the results from the project, since operationally the survey instrument will be used for an initial assessment of and routine monitoring of the ambient dose equivalent dose rate. Additionally, since the response of these instruments is in some cases very well characterised, their systematic deviations from the reference quantities provide an important verification of the determination of those quantities.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Nêutrons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Radiat Prot Dosimetry ; 120(1-4): 378-82, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644993

RESUMO

This work describes spectral distributions of neutrons obtained as function of energy and direction at four workplace fields at the Krümmel reactor in Germany. Values of personal dose equivalent H(p)(10) and effective dose E are determined for different directions of a person's orientation in these fields and readings of personal neutron dosemeters--especially electronic dosemeters--are discussed with respect to H(p)(10) and E.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Proteção Radiológica/métodos , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Eletrônica , Desenho de Equipamento , Análise de Falha de Equipamento , Alemanha , Doses de Radiação , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Propriedades de Superfície , Dosimetria Termoluminescente/métodos
13.
Radiat Prot Dosimetry ; 120(1-4): 263-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16782978

RESUMO

EVIDOS is an EC sponsored project that aims at an evaluation and improvement of radiation protection dosimetry in mixed neutron/photon fields. This is performed through spectrometric and dosimetric investigations during different measurement campaigns in representative workplaces of the nuclear industry. The performance of routine and, in particular, novel personal dosemeters and survey instruments is tested in selected workplace fields. Reference values for the dose equivalent quantities, H(*)(10) and H(p)(10) and the effective dose E, are determined using different spectrometers that provide the energy distribution of the neutron fluence and using newly developed devices that determine the energy and directional distribution of the neutron fluence. The EVIDOS project has passed the mid-term, and three measurement campaigns have been performed. This paper will give an overview and some new results from the third campaign that was held in Mol (Belgium), around the research reactor VENUS and in the MOX producing plant of Belgonucléaire.


Assuntos
Nêutrons , Fótons , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , União Europeia , Doses de Radiação , Monitoramento de Radiação/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Neurochirurgie ; 52(2-3 Pt 1): 111-8, 2006 Jun.
Artigo em Francês | MEDLINE | ID: mdl-16840970

RESUMO

We report a series of five subdural empyema (SDE) in children and young adults treated in the same neurosurgical department. These five cases were reviewed retrospectively. There were four boys and one girl, aged from three months to 18 years at time of diagnosis (median age: 7 years). SDE following intracranial surgery were excluded from the study. All patients were treated surgically (burr hole evacuation or craniotomy, repeated in some cases), followed by intravenous antibiotic therapy (mean time: 52 days) adapted to the micro-organism. Only the two patients treated by large craniotomy at first had a single surgical procedure. Involved micro-organisms are as follow: Streptococcus intermedius (n=2), Streptococcus pneumoniae (n=1), Escherichia coli (n=1), absence of any identified micro-organism (n=1). The five patients are alive (median follow-up: 22 month) without any sequelae. We advocate an aggressive surgical treatment of SDE in children with a large bone flap to allow the surgeon to remove pus and membranes as much as possible, even in the interhemispheric fissure, followed by intravenous appropriate antibiotherapy and eradication of the source of infection. Even this "aggressive" treatment may sometimes not avoid re-operation. A careful follow-up is mandatory, because of the high risk of recurrence.


Assuntos
Empiema Subdural/terapia , Procedimentos Neurocirúrgicos , Adolescente , Antibacterianos/uso terapêutico , Criança , Pré-Escolar , Craniotomia , Empiema Subdural/cirurgia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/tratamento farmacológico , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Infecções Estreptocócicas/tratamento farmacológico , Infecções Estreptocócicas/etiologia
15.
Radiat Prot Dosimetry ; 168(2): 223-34, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25752758

RESUMO

Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org).


Assuntos
Pesquisa Biomédica , Monitoramento de Radiação/normas , Proteção Radiológica , Radiação Ionizante , Radiometria/normas , Europa (Continente) , Guias como Assunto , Humanos , Doses de Radiação
16.
Presse Med ; 34(10): 719-24, 2005 Jun 04.
Artigo em Francês | MEDLINE | ID: mdl-16026125

RESUMO

BACKGROUND: High-dose buprenorphine (HDB) treatment began in France in 1996 according to relatively unrestricted prescription rules. Continued heroin injection by patients on HDB maintenance treatment and even HDB injection remain underestimated and may lead to a variety of infectious diseases. OBJECTIVES: Description of infectious complications occurring in patients receiving HDB maintenance treatment. METHODS: Retrospective study of drug addicts receiving HDB maintenance treatment, injecting (or highly suspected of injecting) it, and hospitalized for infections (other than HIV or viral hepatitis) in the department of infectious and tropical diseases in Nancy University Hospital. Data collection covered 1998 through 2003. RESULTS: We identified 21 case reports, 9 concerning infectious endocarditis, 8 cutaneous abscesses, 2 osteoarticular infections, 1 meningitis and 1 Candida retinitis. The sex-ratio was of 1 woman for 2 men, and the patients' mean age was 29.8 years. Globally 13 patients had systemic infections. Nine patients admitted having injected HDB (and no other drugs) (including the case of Candida retinitis), while in the other 12 cases, the patients continued injecting heroin as well. The role of misused HDB was strongly suspected in those 12 infections, but was not clearly confirmed. All patients recovered from the infections. The long-term psychosocial outcome remains unknown. CONCLUSION: The cases analyzed illustrate the dual reality that HDB is often ineffective as a maintenance treatment, since some patients continue to inject heroin, and that its misuse can have infectious consequences. The results of HDB maintenance treatment substitution are mixed. The individual benefit/risk ratio must be improved. Networking is crucial, notably between physician and pharmacist, and the monitoring system must be reinforced.


Assuntos
Analgésicos Opioides/efeitos adversos , Buprenorfina/efeitos adversos , Endocardite Bacteriana/induzido quimicamente , Dependência de Heroína/reabilitação , Abuso de Substâncias por Via Intravenosa/complicações , Abscesso/induzido quimicamente , Adulto , Analgésicos Opioides/administração & dosagem , Buprenorfina/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Meningite/induzido quimicamente , Osteomielite/induzido quimicamente , Retinite/induzido quimicamente , Estudos Retrospectivos , Dermatopatias/induzido quimicamente
17.
Radiat Res ; 101(1): 177-96, 1985 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3918330

RESUMO

At the Swiss Institute for Nuclear Research (SIN) cancer patients are irradiated with negatively charged pi mesons using a 60-beam medical pion generator, the Piotron. A low-pressure tissue-equivalent proportional counter was used to measure absorbed dose and microdosimetric spectra. A method was developed to allow discrimination of events from different beam components, i.e., beam contamination (electrons and muons), pions in flight, and stopping pions. Measurements were performed along the axis and at lateral distances off one of these identical pion beams. The marked changes of total microdosimetric spectra with depth in phantom detected in earlier measurements are mainly due to large variations in the dose contributions of the beam components and much less to changes in the shapes of the individual microdosimetric spectra. The single beam measurements were used to calculate three-dimensional distributions of absorbed dose and of dose mean lineal energy, yD, for dynamic patient irradiations. Within the whole target volume yD remains nearly constant when irradiated with all 60 beams, whereas considerable changes were found for irradiations with 31 beams coming from a semicircle. Both size and shape of target volumes influence yD, the maximum values ranging from 30 to 45 keV/micron.


Assuntos
Partículas Elementares , Mésons , Neoplasias/radioterapia , Radiometria/instrumentação , Radioterapia de Alta Energia/métodos , Humanos , Dosagem Radioterapêutica , Radioterapia de Alta Energia/instrumentação
18.
Radiat Res ; 111(1): 1-13, 1987 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3602347

RESUMO

Measurements in nearly monoenergetic beams of 144, 24.5, and 2 keV neutrons and of thermal neutrons have been performed with low-pressure proportional counters. The suitability of a tissue-equivalent proportional counter (TEPC) for dosimetry of low-energy neutrons has been investigated. In contrast to higher neutron energies, the modification of the primary radiation field by the detector wall and the contribution of secondaries produced in the gas are significant. These effects have been investigated by additional measurements with a carbon-walled proportional counter. The various physical processes of neutron interaction with wall and gas of the TEPC have been analyzed, and absorbed dose, kerma, and kerma contributions from the various processes are presented. In addition, dose contributions from contaminating neutrons and photons have been obtained for the calibration fields used. The results have been related to neutron fluence. The comparison with tabulated kerma factors shows excellent agreement, indicating the suitability of the TEPC method for dosimetry of low-energy neutrons.


Assuntos
Nêutrons/uso terapêutico , Proteção Radiológica/instrumentação , Transferência de Energia , Nêutrons Rápidos/uso terapêutico , Matemática , Controle de Qualidade , Radioquímica , Dosagem Radioterapêutica
19.
Med Phys ; 26(6): 974-91, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10436900

RESUMO

Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determine kerma coefficients for calculations of energy deposition by neutrons in matter. Methods used to evaluate the neutron cross sections above 20 MeV, using nuclear model calculations and experimental data, are described. Below 20 MeV, the evaluated cross sections from the ENDF/B-VI library are adopted. Comparisons are shown between the evaluated charged-particle production cross sections and measured data. Kerma coefficients are derived from the neutron cross sections, for major isotopes of H, C, N, O, Al, Si, P, Ca, Fe, Cu, W, Pb, and for ICRU-muscle, A-150 tissue-equivalent plastic, and other compounds important for treatment planning and dosimetry. Numerous comparisons are made between our kerma coefficients and experimental kerma coefficient data, to validate our results, and agreement is found to be good. An important quantity in neutron dosimetry is the kerma coefficient ratio of ICRU-muscle to A-150 plastic. When this ratio is calculated from our kerma coefficient data, and averaged over the neutron energy spectra for higher-energy clinical therapy beams [three p (68) + Be beams, and a d (48.5) + Be beam], a value of 0.94 +/- 0.03 is obtained. Kerma ratios for water to A-150 plastic, and carbon to oxygen, are also compared with measurements where available.


Assuntos
Nêutrons Rápidos/uso terapêutico , Nêutrons/uso terapêutico , Radioterapia de Alta Energia , Fenômenos Biofísicos , Biofísica , Carbono , Humanos , Modelos Teóricos , Músculos/efeitos da radiação , Oxigênio , Planejamento da Radioterapia Assistida por Computador , Água
20.
Biol Psychol ; 24(3): 209-23, 1987 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3663796

RESUMO

Previous research has demonstrated that delayed nonverbal information feedback (IF) about the correctness of a positioning movement is preceded by a contingent negative variation (CNV) which is larger over the right hemisphere independent of movement side. It was hypothesized that this asymmetry is a manifestation of functional hemispheric specialization, and that, therefore, the distribution of the differences between CNV amplitude measures of the two hemispheres should be different in right-handed and left-handed subjects. The latter group should show a mean asymmetry score closer to zero, and a larger between-subject variance of the asymmetry scores. The present investigation was intended to test these assumptions in samples of rigorously defined right-handers (n = 12) and left-handers (n = 8). The results revealed the expected group differences of the CNV asymmetry scores. In addition, the P1-N1 peak-to-peak amplitude of the IF-evoked potentials was similarly lateralized as the pre-IF CNV and showed the same group differences. In contrast, the handedness groups did not differ in the contralateral lateralization of the movement-related potential shift in the same task.


Assuntos
Dominância Cerebral , Eletroencefalografia , Lateralidade Funcional , Cinestesia , Propriocepção , Adulto , Variação Contingente Negativa , Potenciais Evocados , Retroalimentação , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA