Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Cancer Res ; 53(5): 1091-7, 1993 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-8439953

RESUMO

The antitumor activity of cis-diamminedichloroplatinum(II) (cP) and human recombinant interleukin-1 alpha (IL-1 alpha) was studied in RIF-1 and SC VII solid tumor models and in a cP-resistant subline of RIF-1 designated RIF-R1cP. In RIF-1 tumors, clonogenic cell survival after cP plus IL-1 alpha combinations was highly schedule and IL-1 alpha dose dependent. More than additive clonogenic cell kill was seen when cP was given 6 h before, but not 8 h before or at 2-6 h after IL-1 alpha. Time course studies indicated that maximal clonogenic cell killing was achieved within 4-6 h after the cP plus IL-1 alpha combination, with little or no recovery for up to 24 h. In vivo dose-response studies indicated that cP plus IL-1 alpha combinations induced more clonogenic cell kill than cP alone in all three tumor models, and analysis by the median effect principle indicated highly synergistic antitumor activity. Dexamethasone but not indomethacin inhibited the synergistic interaction. IL-1 alpha had no effect on the cytotoxicity of cP in SCC VII cells in vitro, and neither in vitro hypoxia nor in vivo ischemia, induced by clamping tumor blood supply, significantly affected cP clonogenic cell killing. Increased clonogenic cell killing was seen, however, after removal of the clamp, implicating reperfusion events, such as oxyradical stress, as a potential mechanism for increased cP cytotoxicity in SCC VII solid tumors. The data from our model systems provide a rationale for additional work to define the mechanisms of the synergistic antitumor activity of the cP plus IL-1 alpha combination and indicate that IL-1 alpha might be a useful adjunct to increase the clinical efficacy of cP-containing strategies for both sensitive and cP-resistant cancers.


Assuntos
Cisplatino/administração & dosagem , Interleucina-1/administração & dosagem , Neoplasias Experimentais/tratamento farmacológico , Animais , Sobrevivência Celular/efeitos dos fármacos , Cisplatino/farmacologia , Relação Dose-Resposta a Droga , Resistência a Medicamentos , Sinergismo Farmacológico , Feminino , Interleucina-1/farmacologia , Camundongos , Camundongos Endogâmicos C3H , Neoplasias Experimentais/patologia , Proteínas Recombinantes/administração & dosagem , Células Tumorais Cultivadas/efeitos dos fármacos
2.
J Clin Oncol ; 11(5): 857-62, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8487050

RESUMO

PURPOSE: The purpose is twofold: (1) to identify the malignant glioma patients treated in a trial of hyperfractionated radiotherapy (RT) and carmustine (BCNU) who may have been eligible for a stereotactic radiosurgery (SRS) boost; and (2) to compare survival of such patients with that of those considered SRS-ineligible. PATIENTS AND METHODS: From January 1983 to July 1989, 778 malignant glioma patients were enrolled on Radiation Therapy Oncology Group (RTOG) 83-02, a randomized phase I/II hyperfractionated RT dose-escalation trial with BCNU chemotherapy. The SRS criteria used in a single-institution trial were applied to these patients; they are: Karnofsky performance status (KPS) of greater than 60; well-circumscribed tumor less than 4.0 cm; no subependymal spread; and a location not adjacent to brainstem or optic chiasm. RESULTS: Eighty-nine patients (11.9%) were identified as potentially SRS-eligible. The median survival times (MST) and 18-month survival rates of the 89 eligible and 643 ineligible patients were 14.4 versus 11.7 months and 40% versus 27%, respectively (P = .047). The MST and 18-month survival rate of the 544 SRS-ineligible patients with KPS greater than 60 were 12.1 months and 29%, respectively, and were not statistically inferior to the survival of the SRS-eligible group (P = .21). Multivariate analysis revealed age, KPS, and histopathology to be strongly predictive of survival, and SRS eligibility was also significantly predictive (P = .047). CONCLUSION: SRS-eligible patients enrolled on RTOG 83-02 had survival superior to that of the SRS-ineligible group, and this advantage is mainly due to the selection of a subgroup with a high minimum KPS.


Assuntos
Carmustina/uso terapêutico , Glioma/tratamento farmacológico , Glioma/radioterapia , Radiocirurgia , Terapia Combinada , Contraindicações , Feminino , Glioma/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Dosagem Radioterapêutica
3.
Int J Radiat Oncol Biol Phys ; 10(10): 1967-9, 1984 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-6436202

RESUMO

New multi-programmable pacemakers frequently employ complementary metal oxide semiconductors (CMOS). This circuitry appears more sensitive to the effects of ionizing radiation when compared to the semiconductor circuits used in older pacemakers. A case of radiation induced runaway pacemaker in a CMOS device is described. Because of this and other recent reports of radiation therapy-induced CMOS type pacemaker failure, these pacemakers should not be irradiated. If necessary, the pacemaker can be shielded or moved to a site which can be shielded before institution of radiation therapy. This is done to prevent damage to the CMOS circuit and the life threatening arrythmias which may result from such damage.


Assuntos
Marca-Passo Artificial/normas , Radioterapia de Alta Energia/efeitos adversos , Semicondutores , Idoso , Axila , Hemangiopericitoma/radioterapia , Humanos , Masculino , Metais , Óxidos
4.
Int J Radiat Oncol Biol Phys ; 20(3): 517-23, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1995537

RESUMO

Stereotactic radiosurgery with a linear accelerator requires the accurate determination of a target volume and an accurate match of the therapeutic radiation dose distribution to the target volume. X ray and CT localizers have been described that are used to define the target volume or target point from angiographic or CT data. To verify the accuracy of these localizers, measurements were made with a target point simulator and an anthropomorphic head phantom. The accuracy of determining a known, high contrast, target point with these localizers was found to be a maximum of +/- 0.5 mm and +/- 1.0 mm for the X ray and CT localizer, respectively. A technique using portal X rays taken with a linear accelerator to verify the target point is also described.


Assuntos
Radioterapia/instrumentação , Técnicas Estereotáxicas/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Dosagem Radioterapêutica
5.
Int J Radiat Oncol Biol Phys ; 21(5): 1321-5, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1938531

RESUMO

Stereotactic radiosurgery techniques for a linear accelerator typically use circular radiation fields to produce an essentially spherical radiation distribution with a steep dose gradient. Target volumes are frequently irregular in shape, and circular distributions may irradiate normal tissues to high dose as well as the target volume. Improvements to the dose distribution have been made using multiple target points and optimizing the dose per arc to the target. A retrospective review of 20 radiosurgery patients has suggested that the use of elliptically shaped fields may further improve the match of the radiation distribution to the intended target volume. This hypothesis has been verified with film measurements of the radiation distribution obtained using elliptical radiation beam in a head phantom. Reductions of 40% of the high dose volume have been obtained with elliptical fields compared to circular fields without compromising the dose to the target volume.


Assuntos
Radiocirurgia/métodos , Dosagem Radioterapêutica , Humanos , Modelos Estruturais , Estudos Retrospectivos
6.
Int J Radiat Oncol Biol Phys ; 47(2): 389-94, 2000 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-10802364

RESUMO

PURPOSE: To determine whether any difference in toxicity or efficacy occurs when head and neck cancer patients are treated postoperatively with (60)C0, 4 MV, or 6 MV photon beam. METHODS AND MATERIALS: This is a secondary analysis of the Intergroup Study 0034. Three hundred ninety-two patients were evaluable for comparison between treatment with (60)C0, 4 MV, or 6 MV photon beam. All patients had advanced but operable squamous cell carcinoma of the oral cavity, oropharynx, hypopharynx, or larynx. Patients were randomized following surgical resection to receive treatment with either postoperative irradiation alone, or postoperative irradiation plus three cycles of cisplatin and 5-fluorouracil. Patients were categorized as having either "low risk" or "high risk" treatment volumes based on whether the surgical margin was 5 mm or less, presence of extra capsular nodal extension, and/or carcinoma in situ at the surgical margins. Low-risk volumes received 50-54 Gy, and high-risk volumes were given 60 Gy. Patients were compared in regards to acute and late radiotherapy toxicities as well as overall survival and loco-regional control according to the beam energy used. RESULTS: One-hundred fifty-seven, 140, and 95 patients were treated by (60)C0, 4 MV, and 6 MV, respectively. No differences were seen in acute or late toxicity among treatment groups. Locoregional control was achieved in 75%, 79%, and 80% of patients treated with (60)C0, 4 MV, or 6 MV (p = 0.61). Patients treated with 6 MV had a higher incidence of ipsilateral neck failure as first event (13%) than patients treated by (60)C0 and 4 MV (9%). This difference was not statistically significant. CONCLUSION: No differences in outcome, acute, or late toxicity were discernible in patients with advanced head and neck cancer treated with (60)C0, 4 MV, or 6 MV. This result should be interpreted with caution as increased incidence, albeit nonsignificant, of ipsilateral neck recurrence was observed in patients treated with 6 MV and the power of the study to detect a statistically significant difference is small.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Radioisótopos de Cobalto/uso terapêutico , Neoplasias de Cabeça e Pescoço/radioterapia , Compostos Radiofarmacêuticos/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/cirurgia , Cisplatino/administração & dosagem , Terapia Combinada , Feminino , Fluoruracila/administração & dosagem , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica
7.
Int J Radiat Oncol Biol Phys ; 8(3-4): 371-5, 1982.
Artigo em Inglês | MEDLINE | ID: mdl-7107354

RESUMO

Since January 1981, 52 patients have entered the Radiation Therapy Oncology Group Phase I trial with intravenous (i.v.) desmethylmisonidazole (DMM). DMM is less lipophilic than misonidazole (MISO) and theoretically will be less neurotoxic due to lower penetration into neural tissue and more rapid elimination. The drug is administered intravenously to achieve the maximum drug concentration in tumor for a given dose. The protocol slowly escalates the total dose of drug administered. At this time the planned dose on the three week schedule is 1g/m2 five times per week to a total of 15g/m2, and on the seven week schedule is 1.25g/m2 twice weekly to a total dose of 17.5g/m2. The preliminary plasma pharmacokinetic data demonstrates high peak plasma levels within five minutes of the end of the drug infusion. Compared to MISO the percent of DMM excreted in the urine is increased, 63% vs 10%, and the elimination half-life is decreased: DMM, i.v. 5.3h; MISO, i.v. 9.3h; MISO, oral 10 to 13h. Neurotoxicity has been observed in approximately 30% of patients given a cumulative dose of greater than 11g/m2. This is in comparison to a 50% incidence in the RTOG Phase I study with oral MISO at doses of 12g/m2. There is not sufficient data to evaluate the relationship between neurotoxicity and drug exposure. Further patient accrual on this study is required to better define the properties of DMM.


Assuntos
Misonidazol/uso terapêutico , Nitroimidazóis/uso terapêutico , Radiossensibilizantes/uso terapêutico , Adulto , Idoso , Avaliação de Medicamentos , Humanos , Injeções Intravenosas , Cinética , Pessoa de Meia-Idade , Misonidazol/efeitos adversos , Misonidazol/análogos & derivados , Misonidazol/metabolismo , Doenças do Sistema Nervoso/induzido quimicamente , Radiossensibilizantes/efeitos adversos , Radiossensibilizantes/metabolismo
8.
Int J Radiat Oncol Biol Phys ; 15(1): 213-8, 1988 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3391817

RESUMO

This paper describes our experience in using the T1 and T2 relaxation times for quantitative evaluation of brain and brain tumor response to radiation therapy. Twenty-two computed T1 and 22 computed T2 images were obtained from 66 routine inversion-recovery and spin-echo magnetic resonance (MR) brain scans. The relaxation times of the brain tissues, determined from the computed images, were examined as a function of the absorbed dose. Statistical evaluation of the results showed no significant difference between the relaxation times of irradiated and not irradiated tissues, including tumor and normal white matter. Influence of the magnetic field strength and imaging techniques on the computed T1 and T2 values was confirmed. We conclude that the relaxation time values, as obtained today using conventional MR scanner and standard software, are not specific enough to warrant a correct assessment of the acute radiation effect on the brain tissues.


Assuntos
Neoplasias Encefálicas/radioterapia , Encéfalo/efeitos da radiação , Imageamento por Ressonância Magnética , Adolescente , Adulto , Criança , Humanos , Pessoa de Meia-Idade
9.
Int J Radiat Oncol Biol Phys ; 24(4): 777-80, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1429104

RESUMO

Stereotactic radiosurgery with a linear accelerator requires an accurate match of the therapeutic radiation distribution to the localized target volume. Techniques for localization of the target volume using CT scans and/or angiograms have been described. Alignment of the therapeutic radiation distribution to the intended point in stereotactic space is usually accomplished using precision mechanical scales which attach to the head ring. The present work describes a technique used to verify that the stereotactic coordinates of the center of the intended radiation distribution are in agreement with the localized target point coordinates. This technique uses anterior/posterior and lateral accelerator portal verification films to localize the stereotactic coordinates of the center of the radiation distribution with the patient in the treatment position. The results of 26 cases have been analyzed. Alignment errors of the therapeutic radiation distribution in excess of 1 mm have been found using the portal film verification procedure.


Assuntos
Encéfalo/cirurgia , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia , Técnicas Estereotáxicas , Angiografia Cerebral , Humanos , Tomografia Computadorizada por Raios X
10.
Int J Radiat Oncol Biol Phys ; 21(6): 1621-5, 1991 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1938572

RESUMO

Computer controlled high dose-rate (HDR) brachytherapy afterloading machines are equipped with a single, miniaturized, high activity Ir-192 source that can be rapidly moved in fine increments among several channels. Consequently, by appropriate programming of source dwell positions and times, the dose distribution can be optimized as desired. We have explored the optimization potential of this new technology for two applications: (a) cervix brachytherapy, and (b) transvaginal irradiation. Cervix brachytherapy with a gynecologic ring applicator was simulated by 48 sources of relative activities ranging from 0.17 to 1.00 that were equally distributed between the tandem and the ring. The results confirmed that the optimized distribution of physical doses are superior to those achievable with standard brachytherapy sources and applicators. For example, with five-point optimization, the relative dose-rate in the rectum was only 47% of that in point A; for standard application the dose rate was 47% higher. For transvaginal application 27 sources of relative activities between 0.07-0.79 were placed in the ring and a single source of unit strength in the tandem. Using dose distribution homogeneity as an optimization criterion, the results (+/- 2.5%) were again superior to those obtained for commonly used double ovoid (+/- 15%), linear cylinder (+/- 27%), or a "T" source (31%).


Assuntos
Braquiterapia , Colo do Útero , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Alta Energia , Vagina , Feminino , Humanos
11.
Int J Radiat Oncol Biol Phys ; 17(5): 1111-4, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2808046

RESUMO

Spatial definition of an intraocular tumor and subsequent determination of the actual position of an implanted eye plaque are essential for adequate ocular brachytherapy treatment planning. However, a method for verification of the plaque placement which would provide required 3-dimensional information is not available at present. In addition, tumor localization procedures, including ultrasonography and CT techniques, cannot always offer the precision needed for 3-dimensional definition of an intraocular target. This communication describes a magnetic resonance imaging technique specifically developed for both localization and verification procedures. A 1.5 Tesla magnetic resonance scanner, spin-echo pulse sequence (echo time 30 msec, repetition time 700 msec), and commercially available surface coil were used to obtain a series of transverse, coronal, and sagittal images of a slice thickness of 3 mm. Usually, eight scans in each of the three planes were needed for adequate coverage of the orbit. The required patient set-up and data acquisition time did not exceed 40 minutes. With a data matrix size of 256 X 256 pixels and 13 cm field of view, localization and verification were accomplished with a precision of 0.5 mm. Our results suggest that the magnetic resonance imaging technique permits precise integration of diagnostic and therapeutic procedures, and in addition provides adequate data for accurate treatment planning. We conclude that magnetic resonance imaging is the preferred diagnostic technique for episcleral brachytherapy.


Assuntos
Braquiterapia/métodos , Neoplasias Oculares/radioterapia , Melanoma/radioterapia , Humanos , Imageamento por Ressonância Magnética , Esclera
12.
Int J Radiat Oncol Biol Phys ; 22(1): 175-80, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1727115

RESUMO

A computer-controlled stereotaxic radiotherapy system based on a low-frequency magnetic field technology integrated with a single fixation point stereotaxic guide has been designed and instituted. The magnetic field, generated in space by a special field source located in the accelerator gantry, is digitized in real time by a field sensor that is six degree-of-freedom measurement device. As this sensor is an integral part of the patient stereotaxic halo, the patient position (x, y, z) and orientation (azimuth, elevation, roll) within the accelerator frame of reference are always known. Six parameters--three coordinates and three Euler space angles--are continuously transmitted to a computer where they are analyzed and compared with the stereotaxic parameters of the target point. Hence, the system facilitates rapid and accurate patient set-up for stereotaxic treatment as well as monitoring of patient during the subsequent irradiation session. The stereotaxic system has been developed to promote the integration of diagnostic and therapeutic procedures, with the specific aim of integrating CT and/or MR aided tumor localization and long term (4- to 7-week) fractionated radiotherapy of small intracranial and ocular lesions.


Assuntos
Radioterapia Assistida por Computador/métodos , Técnicas Estereotáxicas , Fenômenos Eletromagnéticos , Humanos , Planejamento da Radioterapia Assistida por Computador
13.
Int J Radiat Oncol Biol Phys ; 23(4): 705-13, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1618662

RESUMO

To test the efficacy of sequential chemotherapy as an adjuvant to surgery and postoperative radiotherapy for patients with locally-advanced but operable squamous cell cancers of the head and neck region, a randomized clinical trial was conducted under the auspices of the Head and Neck Intergroup (Radiation Therapy Oncology Group, Southwest Oncology Group, Eastern Oncology Group, Cancer and Leukemia Group B, Northern California Oncology Group, and Southeast Group). Eligible patients had completely resected tumors of the oral cavity, oropharynx, hypopharynx, or larynx. They were then randomized to receive either three cycles of cis-platinum and 5-FU chemotherapy followed by postoperative radiotherapy (CT/RT) or postoperative radiotherapy alone (RT). Patients were categorized as having either "low-risk" or "high-risk" treatment volumes depending on whether the surgical margin was greater than or equal to 5 mm, there was extracapsular nodal extension, and/or there was carcinoma-in-situ at the surgical margins. Radiation doses of 50-54 Gy were given to "low-risk" volumes and 60 Gy were given to "high-risk" volumes. A total of 442 analyzable patients were entered into this study with the mean-time-at-risk being 45.7 months at the time of the present analysis. The 4-year actuarial survival rate was 44% on the RT arm and 48% on the CT/RT arm (p = n.s.). Disease-free survival at 4 years was 38% on the RT arm compared to 46% on the CT/RT arm (p = n.s.). At 4 years the local/regional failure rate was 29% vs. 26% for the RT and CT/RT arms, respectively (p = n.s.). The incidence of first failure in the neck nodes was 10% on the RT arm compared to 5% on the CT/RT arm (p = 0.03 without adjusting for multiple testing) and the overall incidence of distant metastases was 23% on the RT arm compared to 15% on the CT/RT arm (p = 0.03). Treatment related toxicity is discussed in detail, but, in general, the chemotherapy was satisfactorily tolerated and did not affect the ability to deliver the subsequent radiotherapy. Implications for future clinical trials are discussed.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/cirurgia , Quimioterapia Adjuvante , Cisplatino/administração & dosagem , Fluoruracila/administração & dosagem , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Radioterapia/efeitos adversos , Distribuição Aleatória , Análise de Sobrevida , Taxa de Sobrevida
14.
Int J Radiat Oncol Biol Phys ; 24(4): 795-801, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1429107

RESUMO

Although high dose-rate brachytherapy with a single, rapidly moving radiation source is becoming a common treatment modality, a suitable formalism for determination of the dose delivered by a moving radiation source has not yet been developed. At present, brachytherapy software simulates high dose-rate treatments using only a series of stationary sources, and consequently fails to account for the dose component delivered while the source is in motion. We now describe a practical model for determination of the true, total dose administered. The algorithm calculates both the dose delivered while the source is in motion within and outside of the implanted volume (dynamic component), and the dose delivered while the source is stationary at a series of fixed dwell points. It is shown that the dynamic dose element cannot be ignored because it always increases the dose at the prescription points and, in addition, distorts the dose distribution within and outside of the irradiated volume. Failure to account for the dynamic dose component results in dosimetric errors that range from significant (> 10%) to negligible (< 1%), depending on the prescribed dose, source activity, and source speed as defined by the implant geometry.


Assuntos
Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador , Humanos , Doses de Radiação
15.
Int J Radiat Oncol Biol Phys ; 27(5): 1011-6, 1993 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-8262821

RESUMO

PURPOSE: The purpose of this study was to determine whether or not for patients with squamous cell carcinomas of the head and neck, a surgical resection leaving positive margins followed by postoperative adjuvant therapy improves the outcome compared to a matched group of patients treated with definitive radiotherapy alone. METHODS AND MATERIALS: From January 1985 through January 1990 a consortium of national cooperative groups (Radiation Therapy Oncology Group, Cancer and Leukemia Group B, Eastern Cooperative Oncology Group, Northern California Oncology Group, Southeast Group, and Southwest Oncology Group) conducted a phase III clinical trial testing the efficacy of adjuvant chemotherapy for patients with resectable, squamous cell carcinomas of the head and neck. One hundred and nine patients were excluded from this study due to positive surgical margins. These patients have been followed prospectively with regards to local/regional tumor control, development of distant metastases, and survival. The postoperative treatment of these patients was not specified by the protocol but the majority of patients received postoperative radiotherapy +/- chemotherapy. These patients were compared with a matched group of patients from the Radiation Therapy Oncology Group head and neck database of patients treated with definitive radiotherapy alone using a standard fractionation schema. Matching parameters included primary tumor site, T-stage, N-stage, Karnofsky performance status, and age. RESULTS: Actuarial curves are presented for local/regional control and survival. At 4 years the local/regional control rate is 44% for the positive margin patients compared to 24% for the patients from the data base (p = 0.007). However, there is no significant difference between the survival curves (p = 0.76) with respective median survivals being 18.1 months vs. 17.9 months and 4-year survivals being 29% vs. 25%. CONCLUSION: While an incomplete excision followed by postoperative therapy does not seem to improve survival compared to treatment with radiotherapy alone, it appears to yield significantly better local/regional control. This would argue for its applicability in selected palliative settings. A follow-up, Phase III trial for patients with advanced tumors may be warranted to test traditional resectability criteria.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/cirurgia , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/cirurgia , Análise Atuarial , Fatores Etários , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/mortalidade , Quimioterapia Adjuvante , Bases de Dados Factuais , Feminino , Seguimentos , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Estadiamento de Neoplasias , Fatores Sexuais , Taxa de Sobrevida , Fatores de Tempo
16.
Chest ; 81(4): 453-6, 1982 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7067511

RESUMO

Seven patients with squamous cell carcinoma of the esophagus received radiation therapy in twice weekly 400 rad fractions over five weeks followed by esophagectomy. Four of these patients developed severe interstitial pulmonary infiltrates and died of pulmonary insufficiency 18-50 days after surgery. In three of these patients the infiltrates were detected within 24 hours of surgery while the infiltrate was not present until the eighth postoperative day in the fourth patient. Postmortem examination revealed widespread dilatation of interstitial and subpleural lymphatics. It is postulated that the combination of large fraction radiation therapy followed by extensive surgery resulted in lymphatic obstruction.


Assuntos
Carcinoma de Células Escamosas/cirurgia , Neoplasias Esofágicas/cirurgia , Pulmão/patologia , Fibrose Pulmonar/etiologia , Idoso , Carcinoma de Células Escamosas/radioterapia , Neoplasias Esofágicas/radioterapia , Humanos , Pneumopatias/diagnóstico por imagem , Sistema Linfático/patologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Radiografia , Dosagem Radioterapêutica
17.
Med Phys ; 18(6): 1266-70, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1753916

RESUMO

Dosimetry calculations for iridium-192 sources generally assume that a sufficient medium surrounds both the iridium source(s) and the point of calculation so that full scattering conditions exist. In several clinical applications the iridium sources may be anatomically located so that the full scattering requirement is not satisfied. To assess the magnitude of this problem, relative measurements were made with a small ionization chamber in phantoms near air and lung-equivalent interfaces. Dose reduction caused by decreasing the volume of scattering material near these interfaces was then evaluated for a few clinical applications. The results show that reductions on the order of 8% may be expected at the interface with minimal dose reduction within the volume of the implant itself. In addition, the results indicate the verification of source strength of iridium sources in phantom require phantom dimensions determined by the source-chamber separation distance.


Assuntos
Braquiterapia , Radioisótopos de Irídio/uso terapêutico , Radiometria/métodos , Dosagem Radioterapêutica , Humanos , Modelos Estruturais , Radiometria/instrumentação , Espalhamento de Radiação
18.
Med Phys ; 19(6): 1451-3, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1461209

RESUMO

Assessment of electron beam energy and its long term stability is part of standard quality assurance practice in radiation oncology. Conventional depth-ionization or depth-film density measurements are time consuming both in terms of data acquisition and analysis. A procedure is described utilizing ionization measurements at two energy specific depths. It is based on a linear relationship between electron beam energy and its practical range. Energy shifts within the range covered by the two measurement depths are easily resolved. Within a range of +/- 0.50 MeV (+/- 1.30 MeV) around the established mean incident energy of 5.48 MeV (20.39 MeV), the method accuracy is better than 0.10 MeV.


Assuntos
Elétrons , Aceleradores de Partículas , Radioterapia de Alta Energia/normas , Humanos
19.
Med Phys ; 19(1): 181-5, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1620045

RESUMO

Stereotactic radiosurgery of the brain may be accomplished with a linear accelerator by performing several noncoplanar arcs of a highly collimated beam focused at a point. The shape of the radiation distribution produced by this technique is affected by the beam energy, field size, and the number and size of the arcs. The influence of these parameters on the resulting radiation distributions was analyzed by computing dose volume histograms for a typical brain. Dose volume functions were computed for: (a) the energy range of 4-24 MV x rays; (b) target sizes of 1-4 cm; and (c) 1-11 arcs and dynamic rotation. The dose volume histograms were found to be dependent on the number of arcs for target sizes of 1-4 cm. However, these differences were minimal for techniques with 4 arcs or more. The influence of beam energy on the dose volume histogram was also found to be minimal.


Assuntos
Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Encéfalo/anatomia & histologia , Humanos , Aceleradores de Partículas
20.
Am J Clin Oncol ; 17(3): 234-8, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8192109

RESUMO

This prospective study attempted to evaluate the indications for glucocorticoids which are commonly given to patients with brain metastases. Twelve patients with histologically confirmed malignancies and radiographically documented brain metastases were enrolled. Patients were scored for general performance status and neurologic function class. All subjects were given high-dose dexamethasone (HDD) for 48 hours and then randomized to receive either intermediate-dose dexamethasone (IDD) or no steroids with cranial radiotherapy. Of these 12 study patients, 3 achieved a complete response, 1 partial response, and 8 nonresponses to HDD. Seven patients had IDD, while five received no IDD. Although a small sample size prevented any statistical analysis, this study does suggest that the place for using glucocorticoids in treating patients with metastatic carcinoma to the brain remains uncertain and should be evaluated in a cooperative prospective trial.


Assuntos
Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/secundário , Dexametasona/uso terapêutico , Adulto , Idoso , Neoplasias Encefálicas/radioterapia , Quimioterapia Adjuvante , Dexametasona/administração & dosagem , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA