Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Radiology ; 310(3): e231429, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38530172

RESUMO

Background Differentiating between benign and malignant vertebral fractures poses diagnostic challenges. Purpose To investigate the reliability of CT-based deep learning models to differentiate between benign and malignant vertebral fractures. Materials and Methods CT scans acquired in patients with benign or malignant vertebral fractures from June 2005 to December 2022 at two university hospitals were retrospectively identified based on a composite reference standard that included histopathologic and radiologic information. An internal test set was randomly selected, and an external test set was obtained from an additional hospital. Models used a three-dimensional U-Net encoder-classifier architecture and applied data augmentation during training. Performance was evaluated using the area under the receiver operating characteristic curve (AUC) and compared with that of two residents and one fellowship-trained radiologist using the DeLong test. Results The training set included 381 patients (mean age, 69.9 years ± 11.4 [SD]; 193 male) with 1307 vertebrae (378 benign fractures, 447 malignant fractures, 482 malignant lesions). Internal and external test sets included 86 (mean age, 66.9 years ± 12; 45 male) and 65 (mean age, 68.8 years ± 12.5; 39 female) patients, respectively. The better-performing model of two training approaches achieved AUCs of 0.85 (95% CI: 0.77, 0.92) in the internal and 0.75 (95% CI: 0.64, 0.85) in the external test sets. Including an uncertainty category further improved performance to AUCs of 0.91 (95% CI: 0.83, 0.97) in the internal test set and 0.76 (95% CI: 0.64, 0.88) in the external test set. The AUC values of residents were lower than that of the best-performing model in the internal test set (AUC, 0.69 [95% CI: 0.59, 0.78] and 0.71 [95% CI: 0.61, 0.80]) and external test set (AUC, 0.70 [95% CI: 0.58, 0.80] and 0.71 [95% CI: 0.60, 0.82]), with significant differences only for the internal test set (P < .001). The AUCs of the fellowship-trained radiologist were similar to those of the best-performing model (internal test set, 0.86 [95% CI: 0.78, 0.93; P = .39]; external test set, 0.71 [95% CI: 0.60, 0.82; P = .46]). Conclusion Developed models showed a high discriminatory power to differentiate between benign and malignant vertebral fractures, surpassing or matching the performance of radiology residents and matching that of a fellowship-trained radiologist. © RSNA, 2024 See also the editorial by Booz and D'Angelo in this issue.


Assuntos
Aprendizado Profundo , Fraturas da Coluna Vertebral , Humanos , Feminino , Masculino , Idoso , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Hospitais Universitários
2.
J Magn Reson Imaging ; 59(5): 1542-1552, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37501387

RESUMO

BACKGROUND: Several magnetic resonance (MR) techniques have been suggested for radiation-free imaging of osseous structures. PURPOSE: To compare the diagnostic value of ultra-short echo time and gradient echo T1-weighted MRI for the assessment of vertebral pathologies using histology and computed tomography (CT) as the reference standard. STUDY TYPE: Prospective. SUBJECTS: Fifty-nine lumbar vertebral bodies harvested from 20 human cadavers (donor age 73 ± 13 years; 9 male). FIELD STRENGTH/SEQUENCE: Ultra-short echo time sequence optimized for both bone (UTEb) and cartilage (UTEc) imaging and 3D T1-weighted gradient-echo sequence (T1GRE) at 3 T; susceptibility-weighted imaging (SWI) gradient echo sequence at 1.5 T. CT was performed on a dual-layer dual-energy CT scanner using a routine clinical protocol. ASSESSMENT: Histopathology and conventional CT were acquired as standard of reference. Semi-quantitative and quantitative morphological features of degenerative changes of the spines were evaluated by four radiologists independently on CT and MR images independently and blinded to all other information. Features assessed were osteophytes, endplate sclerosis, visualization of cartilaginous endplate, facet joint degeneration, presence of Schmorl's nodes, and vertebral dimensions. Vertebral disorders were assessed by a pathologist on histology. STATISTICAL TESTS: Agreement between T1GRE, SWI, UTEc, and UTEb sequences and CT imaging and histology as standard of reference were assessed using Fleiss' κ and intra-class correlation coefficients, respectively. RESULTS: For the morphological assessment of osteophytes and endplate sclerosis, the overall agreement between SWI, T1GRE, UTEb, and UTEc with the reference standard (histology combined with CT) was moderate to almost perfect for all readers (osteophytes: SWI, κ range: 0.68-0.76; T1GRE: 0.92-1.00; UTEb: 0.92-1.00; UTEc: 0.77-0.85; sclerosis: SWI, κ range: 0.60-0.70; T1GRE: 0.77-0.82; UTEb: 0.81-0.92; UTEc: 0.61-0.71). For the visualization of the cartilaginous endplate, UTEc showed the overall best agreement with the reference standard (histology) for all readers (κ range: 0.85-0.93). DATA CONCLUSIONS: Morphological assessment of vertebral pathologies was feasible and accurate using the MR-based bone imaging sequences compared to CT and histopathology. T1GRE showed the overall best performance for osseous changes and UTEc for the visualization of the cartilaginous endplate. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Osteófito , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Esclerose , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Vértebras Lombares/diagnóstico por imagem , Padrões de Referência
3.
Eur Radiol ; 34(4): 2437-2444, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37691079

RESUMO

OBJECTIVES: MR imaging-based proton density fat fraction (PDFF) and T2* imaging has shown to be useful for the evaluation of degenerative changes in the spine. Therefore, the aim of this study was to investigate the influence of myelotoxic chemotherapy on the PDFF and T2* of the thoracolumbar spine in comparison to changes in bone mineral density (BMD). METHODS: In this study, 19 patients were included who had received myelotoxic chemotherapy (MC) and had received a MR imaging scan of the thoracolumbar vertebrates before and after the MC. Every patient was matched for age, sex, and time between the MRI scans to two controls without MC. All patients underwent 3-T MR imaging including the thoracolumbar spine comprising chemical shift encoding-based water-fat imaging to extract PDFF and T2* maps. Moreover, trabecular BMD values were determined before and after chemotherapy. Longitudinal changes in PDFF and T2* were evaluated and compared to changes in BMD. RESULTS: Absolute mean differences of PDFF values between scans before and after MC were at 8.7% (p = 0.01) and at -0.5% (p = 0.57) in the control group, resulting in significantly higher changes in PDFF in patients with MC (p = 0.008). BMD and T2* values neither showed significant changes in patients with nor in those without myelotoxic chemotherapy (p = 0.15 and p = 0.47). There was an inverse, yet non-significant correlation between changes in PDFF and BMD found in patients with myelotoxic chemotherapy (r = -0.41, p = 0.12). CONCLUSION: Therefore, PDFF could be a useful non-invasive biomarker in order to detect changes in the bone marrow in patients receiving myelotoxic therapy. CLINICAL RELEVANCE STATEMENT: Using PDFF as a non-invasive biomarker for early bone marrow changes in oncologic patients undergoing myelotoxic treatment may help enable more targeted countermeasures at commencing states of bone marrow degradation and reduce risks of possible fragility fractures. KEY POINTS: Quantifying changes in bone marrow fat fraction, as well as T2* caused by myelotoxic pharmaceuticals using proton density fat fraction, is feasible. Proton density fat fraction could potentially be established as a non-invasive biomarker for early bone marrow changes in oncologic patients undergoing myelotoxic treatment.


Assuntos
Medula Óssea , Prótons , Humanos , Medula Óssea/diagnóstico por imagem , Coluna Vertebral , Imageamento por Ressonância Magnética/métodos , Biomarcadores , Tecido Adiposo/diagnóstico por imagem
4.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730373

RESUMO

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Membro Posterior , Animais , Cavalos/fisiologia , Fenômenos Biomecânicos , Fraturas do Fêmur/veterinária , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/veterinária , Fixação Interna de Fraturas/métodos , Membro Posterior/cirurgia , Análise de Elementos Finitos , Fêmur/cirurgia , Modelos Biológicos , Suporte de Carga , Fixação Intramedular de Fraturas/veterinária , Fixação Intramedular de Fraturas/instrumentação
5.
Strahlenther Onkol ; 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37676483

RESUMO

PURPOSE: Co-prevalence of abdominal aortic aneurysm (AAA) and cancer poses a unique challenge in medical care since both diseases and their respective therapies might interact. Recently, reduced AAA growth rates were observed in cancer patients that received radiation therapy (RT). The purpose of this study was to perform a fine-grained analysis of the effects of RT on AAA growth with respect to direct (infield) and out-of-field (outfield) radiation exposure, and radiation dose-dependency. METHODS: A retrospective single-center analysis identified patients with AAA, cancer, and RT. Clinical data, radiation plans, and aneurysm diameters were analyzed. The total dose of radiation to each aneurysm was computed. AAA growth under infield and outfield exposure was compared to patients with AAA and cancer that did not receive RT (no-RT control) and to an external noncancer AAA reference cohort. RESULTS: Between 2003 and 2020, a total of 38 AAA patients who had received well-documented RT for their malignancy were identified. AAA growth was considerably reduced for infield patients (n = 18) compared to outfield patients (n = 20), albeit not significantly (0.8 ± 1.0 vs. 1.3 ± 1.6 mm/year, p = 0.28). Overall, annual AAA growth in RT patients was lower compared to no-RT control patients (1.1 ± 1.5 vs. 1.8 ± 2.2 mm/year, p = 0.06) and significantly reduced compared to the reference cohort (1.1 ± 1.5 vs. 2.7 ± 2.1 mm/year, p < 0.001). The pattern of AAA growth reduction due to RT was corroborated in linear regression analyses correcting for initial AAA diameter. A further investigation with respect to dose-dependency of radiation effects on AAA growth, however, revealed no apparent association. CONCLUSION: In this study, both infield and outfield radiation exposure were associated with reduced AAA growth. This finding warrants further investigation, both in a larger scale clinical cohort and on a molecular level.

6.
Eur Radiol ; 33(7): 4875-4884, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36806569

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of an automated reconstruction algorithm combining MR imaging acquired using compressed SENSE (CS) with deep learning (DL) in order to reconstruct denoised high-quality images from undersampled MR images in patients with shoulder pain. METHODS: Prospectively, thirty-eight patients (14 women, mean age 40.0 ± 15.2 years) with shoulder pain underwent morphological MRI using a pseudo-random, density-weighted k-space scheme with an acceleration factor of 2.5 using CS only. An automated DL-based algorithm (CS DL) was used to create reconstructions of the same k-space data as used for CS reconstructions. Images were analyzed by two radiologists and assessed for pathologies, image quality, and visibility of anatomical landmarks using a 4-point Likert scale. RESULTS: Overall agreement for the detection of pathologies between the CS DL reconstructions and CS images was substantial to almost perfect (κ 0.95 (95% confidence interval 0.82-1.00)). Image quality and the visibility of the rotator cuff, articular cartilage, and axillary recess were overall rated significantly higher for CS DL images compared to CS (p < 0.03). Contrast-to-noise ratios were significantly higher for cartilage/fluid (CS DL 198 ± 24.3, CS 130 ± 32.2, p = 0.02) and ligament/fluid (CS DL 184 ± 17.3, CS 141 ± 23.5, p = 0.03) and SNR values were significantly higher for ligaments and muscle of the CS DL reconstructions (p < 0.04). CONCLUSION: Evaluation of shoulder pathologies was feasible using a DL-based algorithm for MRI reconstruction and denoising. In clinical routine, CS DL may be beneficial in particular for reducing image noise and may be useful for the detection and better discrimination of discrete pathologies. Assessment of shoulder pathologies was feasible with improved image quality as well as higher SNR using a compressed sensing deep learning-based framework for image reconstructions and denoising. KEY POINTS: • Automated deep learning-based reconstructions showed a significant increase in signal-to-noise ratio and contrast-to-noise ratio (p < 0.04) with only a slight increase of reconstruction time of 40 s compared to CS. • All pathologies were accurately detected with no loss of diagnostic information or prolongation of the scan time. • Significant improvements of the image quality as well as the visibility of the rotator cuff, articular cartilage, and axillary recess were detected.


Assuntos
Cartilagem Articular , Aprendizado Profundo , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Dor de Ombro/diagnóstico por imagem , Ombro/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Razão Sinal-Ruído , Processamento de Imagem Assistida por Computador/métodos
7.
Eur Radiol ; 33(12): 8617-8626, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37453986

RESUMO

OBJECTIVES: To evaluate and compare the diagnostic performance of CT-like images based on a 3D T1-weighted spoiled gradient-echo sequence (T1 GRE), an ultra-short echo time sequence (UTE), and a 3D T1-weighted spoiled multi-echo gradient-echo sequence (FRACTURE) with conventional CT in patients with suspected osseous shoulder pathologies. MATERIALS AND METHODS: Patients with suspected traumatic dislocation of the shoulder (n = 46, mean age 40 ± 14.5 years, 19 women) were prospectively recruited and received 3-T MR imaging including 3D T1 GRE, UTE, and 3D FRACTURE sequences. CT was performed in patients with acute fractures and served as standard of reference (n = 25). Agreement of morphological features between the modalities was analyzed including the glenoid bone loss, Hill-Sachs interval, glenoid track, and the anterior straight-line length. Agreement between the modalities was assessed using Bland-Altman plots, Student's t-test, and Pearson's correlation coefficient. Inter- and intrareader assessment was evaluated with weighted Cohen's κ and intraclass correlation coefficient. RESULTS: All osseous pathologies were detected accurately on all three CT-like sequences (n = 25, κ = 1.00). No significant difference in the percentage of glenoid bone loss was found between CT (mean ± standard deviation, 20.3% ± 8.0) and CT-like MR images (FRACTURE 20.6% ± 7.9, T1 GRE 20.4% ± 7.6, UTE 20.3% ± 7.7, p > 0.05). When comparing the different measurements on CT-like images, measurements performed using the UTE images correlated best with CT. CONCLUSION: Assessment of bony Bankart lesions and other osseous pathologies was feasible and accurate using CT-like images based on 3-T MRI compared with conventional CT. Compared to the T1 GRE and FRACTURE sequence, the UTE measurements correlated best with CT. CLINICAL RELEVANCE STATEMENT: In an acute trauma setting, CT-like images based on a T1 GRE, UTE, or FRACTURE sequence might be a useful alternative to conventional CT scan sparing associated costs as well as radiation exposure. KEY POINTS: • No significant differences were found for the assessment of the glenoid bone loss when comparing measurements of CT-like MR images with measurements of conventional CT images. • Compared to the T1 GRE and FRACTURE sequence, the UTE measurements correlated best with CT whereas the FRACTURE sequence appeared to be the most robust regarding motion artifacts. • The T1 GRE sequence had the highest resolution with high bone contrast and detailed delineation of even small fractures but was more susceptible to motion artifacts.


Assuntos
Doenças Ósseas Metabólicas , Fraturas Ósseas , Articulação do Ombro , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Ombro , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Imageamento Tridimensional/métodos
8.
Eur Radiol ; 33(2): 1445-1455, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35980430

RESUMO

OBJECTIVES: To evaluate the performance of single-echo Dixon water-fat imaging and computed tomography (CT)-like imaging based on a single ultrashort echo time (sUTE) MR sequence for imaging of vertebral fractures as well as degenerative bone changes of the spine in comparison to conventional CT and MR sequences. METHODS: Thirty patients with suspected acute vertebral fractures were examined using a 3-T MRI, including an sUTE sequence as well as short-tau inversion recovery (STIR) and T1-weighted sequences. During postprocessing, water-fat separation was performed by solving the smoothness-constrained inverse water-fat problem based on a single-complex UTE image. By removing the unwanted low-frequency phase terms, additional MR-based susceptibility-weighted-like (SW-like) images with CT-like contrast were created. Two radiologists evaluated semi-quantitative and quantitative features of fractures and degenerative changes independently and separately on CT and MR images. RESULTS: In total, all 58 fractures were accurately detected of whom 24 were correctly classified as acute fractures with an edema detected on the water-fat-separated UTE images, using STIR and T1w sequences as standard of reference. For the morphological assessment of fractures and degenerative changes, the overall agreement between SW-like images and CT was substantial to excellent (e.g., Genant: κ 0.90 (95% confidence interval 0.54-1.00); AO/Magerl: κ 0.75 (95% confidence interval 0.43-1.00)). Overall inter-reader agreement for water-fat-separated UTE images and SW-like images was substantial to almost perfect. CONCLUSION: Detection and assessment of vertebral fractures and degenerative bone changes of the spine were feasible and accurate using water-fat-separated images as well as SW-like images, both derived from the same sUTE-Dixon sequence. KEY POINTS: • The detection of acute vertebral fractures was feasible using water-fat-separated images and CT-like images reconstructed from one sUTE sequence. • Assessment of the vertebral fractures using SW-like images with CT-like contrast was found to be comparable to conventional CT. • sUTE imaging of the spine can help reduce examination times and radiation exposure.


Assuntos
Fraturas Ósseas , Fraturas da Coluna Vertebral , Humanos , Água , Coluna Vertebral , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
9.
Vasa ; 52(1): 38-45, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36373268

RESUMO

Background: Multi-morbidity poses a substantial challenge for health care in an aging population. Recent studies did not provide evidence for general side effects of anti-cancer therapy regarding the growth rate of coincident abdominal aortic aneurysms, although it was suggested that specific therapeutic substances might accelerate growth. Aneurysm pathology, however, differs with respect to localization. Hence, we present the first ever analysis on the association of cancer and cancer therapy with growth alteration of aneurysms of the ascending aorta (AscAA). Patients and methods: A retrospective single-center identification of AscAA+cancer patients was performed in the institutional picture archiving and communication system (PACS). Included were all patients with ≥2 CT angiograms over ≥6 months and additional malignancy. Clinical data and aneurysm diameters were retrieved and analyzed for an association of cancer (stratified by tumor entity) or cancer therapy (stratified by several classes of chemotherapeutic agents and radiation therapy) with annual growth rate, respectively. Statistics included t-test, Wilcoxon test, and a linear regression model accounting for initial AscAA diameter and type of treatment. Results: From 2003 to 2021, 151 patients (median age 70 years; 85% male) with AscAA and coincident 163 malignancies were identified. Prostate (37%) and hematologic cancer (17%) were most frequent. One-hundred-eleven patients (74%) received chemotherapy and 75 patients (50%) had radiation. After exclusion of six patients with an initial AscAA diameter >55 mm, the average annual AscAA growth rate was 0.18±0.64 mm/year, with only 12 patients experiencing a growth rate >1mm/year. Neither tumor entity nor radiation or chemotherapy - alone or in combination - were significantly associated with an alteration of the annual AscAA growth rate. Likewise, a subanalysis for singular chemotherapeutic agents did not reveal a specific association with AscAA growth alteration. Conclusions: Growth rates of AscAA are low in this cohort with coincident malignancy. Cancer and/or chemotherapy or radiation are not associated with an alteration of the annual growth rate. Additional control examinations seem unnecessary.


Assuntos
Aneurisma da Aorta Abdominal , Neoplasias , Humanos , Masculino , Idoso , Feminino , Estudos Retrospectivos , Aorta Torácica , Aorta/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aneurisma da Aorta Abdominal/terapia
10.
Magn Reson Med ; 87(4): 1771-1783, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34752650

RESUMO

PURPOSE: To develop a methodology to simultaneously perform single echo Dixon water-fat imaging and susceptibility-weighted imaging (SWI) based on a single echo time (TE) ultra-short echo time (UTE) (sUTE) scan to assess vertebral fractures and degenerative bone changes in the thoracolumbar spine. METHODS: A methodology was developed to solve the smoothness-constrained inverse water-fat problem to separate water and fat while removing unwanted low-frequency phase terms. Additionally, the corrected UTE phase was used for SWI. UTE imaging (TE: 0.14 ms, 3T MRI) was performed in the lumbar spine of nine patients with vertebral fractures and bone marrow edema (BME). All images were reviewed by two radiologists. Water- and fat-separated images were analyzed in comparison with short-tau inversion recovery (STIR) and with respect to BME visibility. The visibility of fracture lines and cortical outlining of the UTE magnitude images were analyzed in comparison with computed tomography. RESULTS: Unwanted phase components, dominated by the B1 phase, were removed from the UTE phase images. The rating of the diagnostic quality of BME visualization showed a high preference for the sUTE-Dixon water- and fat-separated images in comparison with STIR. The UTE magnitude images enabled better visualizing fracture lines compared with STIR and slightly better visibility of cortical outlining. With increasing SWI weighting osseous structures and fatty tissues were enhanced. CONCLUSION: The proposed sUTE-Dixon-SWI methodology allows the removal of unwanted low-frequency phases and enables water-fat separation and SWI processing from a single complex UTE image. The methodology can be used for the simultaneous assessment of vertebral fractures and BME of the thoracolumbar spine.


Assuntos
Imageamento por Ressonância Magnética , Água , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral , Tomografia Computadorizada por Raios X/métodos
11.
Eur Radiol ; 32(7): 4738-4748, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35258673

RESUMO

OBJECTIVES: To evaluate the performance and reproducibility of MR imaging features in the diagnosis of joint invasion (JI) by malignant bone tumors. METHODS: MR images of patients with and without JI (n = 24 each), who underwent surgical resection at our institution, were read by three radiologists. Direct (intrasynovial tumor tissue (ITT), intraarticular destruction of cartilage/bone, invasion of capsular/ligamentous insertions) and indirect (tumor size, signal alterations of epiphyseal/transarticular bone (bone marrow replacement/edema-like), synovial contrast enhancement, joint effusion) signs of JI were assessed. Odds ratios, sensitivity, specificity, PPV, NPV, and reproducibilities (Cohen's and Fleiss' κ) were calculated for each feature. Moreover, the diagnostic performance of combinations of direct features was assessed. RESULTS: Forty-eight patients (28.7 ± 21.4 years, 26 men) were evaluated. All readers reliably assessed the presence of JI (sensitivity = 92-100 %; specificity = 88-100%, respectively). Best predictors for JI were direct visualization of ITT (OR = 186-229, p < 0.001) and destruction of intraarticular bone (69-324, p < 0.001). Direct visualization of ITT was also highly reliable in assessing JI (sensitivity, specificity, PPV, NPV = 92-100 %), with excellent reproducibility (κ = 0.83). Epiphyseal bone marrow replacement and synovial contrast enhancement were the most sensitive indirect signs, but lacked specificity (29-54%). By combining direct signs with high specificity, sensitivity was increased (96 %) and specificity (100 %) was maintained. CONCLUSION: JI by malignant bone tumors can reliably be assessed on preoperative MR images with high sensitivity, specificity, and reproducibility. Particularly direct visualization of ITT, destruction of intraarticular bone, and a combination of highly specific direct signs were valuable, while indirect signs were less predictive and specific. KEY POINTS: • Direct visualization of intrasynovial tumor was the single most sensitive and specific (92-100%) MR imaging sign of joint invasion. • Indirect signs of joint invasion, such as joint effusion or synovial enhancement, were less sensitive and specific compared to direct signs. • A combination of the most specific direct signs of joint invasion showed best results with perfect specificity and PPV (both 100%) and excellent sensitivity and NPV (both 96 %).


Assuntos
Neoplasias Ósseas , Neoplasias Ósseas/diagnóstico , Humanos , Ligamentos Articulares/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Eur Radiol ; 32(9): 6247-6257, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35396665

RESUMO

OBJECTIVES: To develop and validate machine learning models to distinguish between benign and malignant bone lesions and compare the performance to radiologists. METHODS: In 880 patients (age 33.1 ± 19.4 years, 395 women) diagnosed with malignant (n = 213, 24.2%) or benign (n = 667, 75.8%) primary bone tumors, preoperative radiographs were obtained, and the diagnosis was established using histopathology. Data was split 70%/15%/15% for training, validation, and internal testing. Additionally, 96 patients from another institution were obtained for external testing. Machine learning models were developed and validated using radiomic features and demographic information. The performance of each model was evaluated on the test sets for accuracy, area under the curve (AUC) from receiver operating characteristics, sensitivity, and specificity. For comparison, the external test set was evaluated by two radiology residents and two radiologists who specialized in musculoskeletal tumor imaging. RESULTS: The best machine learning model was based on an artificial neural network (ANN) combining both radiomic and demographic information achieving 80% and 75% accuracy at 75% and 90% sensitivity with 0.79 and 0.90 AUC on the internal and external test set, respectively. In comparison, the radiology residents achieved 71% and 65% accuracy at 61% and 35% sensitivity while the radiologists specialized in musculoskeletal tumor imaging achieved an 84% and 83% accuracy at 90% and 81% sensitivity, respectively. CONCLUSIONS: An ANN combining radiomic features and demographic information showed the best performance in distinguishing between benign and malignant bone lesions. The model showed lower accuracy compared to specialized radiologists, while accuracy was higher or similar compared to residents. KEY POINTS: • The developed machine learning model could differentiate benign from malignant bone tumors using radiography with an AUC of 0.90 on the external test set. • Machine learning models that used radiomic features or demographic information alone performed worse than those that used both radiomic features and demographic information as input, highlighting the importance of building comprehensive machine learning models. • An artificial neural network that combined both radiomic and demographic information achieved the best performance and its performance was compared to radiology readers on an external test set.


Assuntos
Neoplasias Ósseas , Aprendizado de Máquina , Adolescente , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Raios X , Adulto Jovem
13.
Eur J Vasc Endovasc Surg ; 64(2-3): 255-264, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35853577

RESUMO

OBJECTIVE: The purpose of this study was to assess the associations between malignancy, therapeutic regimens, and aorto-iliac aneurysm (i.e., abdominal aortic aneurysm [AAA]) growth rates. METHODS: A retrospective single centre analysis identified patients with an AAA plus cancer. Patients who had two or more computed tomography angiograms over six months or more and additional malignancy were included. Clinical data and aneurysm diameters were analysed. AAA growth under cancer therapy (chemotherapy or radiation) was compared with a non-cancer AAA control cohort and to meta-analysis data. Statistics included t tests and a linear regression model with correction for initial aortic diameter and type of treatment. RESULTS: From 2003 to 2020, 217 patients (median age 70 years; 92% male) with 246 aneurysms (58.8% AAA) and 238 malignancies were identified. Prostate (26.7%) and lung (15.7%) cancer were most frequently seen. One hundred and fifty-seven patients (72.3%) received chemotherapy, 105 patients (48.4%) radiation, and 79 (36.4%) both. Annual AAA growth (mean ± standard deviation) was not statistically significantly different for cancer and non-cancer patients (2.0 ± 2.3 vs. 2.8 ± 2.1 mm/year; p = .20). However, subgroup analyses revealed that radiation was associated with a statistically significantly reduced mean aneurysm growth rate compared with cancer patients without radiation (1.1 ± 1.3 vs. 1.6 ± 2.1 mm/year; p = .046) and to the non-cancer control cohort (1.7 ± 1.9 vs. 2.8 ± 2.1 mm/year; p = .007). Administration of antimetabolites resulted in statistically significantly increased AAA growth (+ 0.9 mm/year; p = .011), while topoisomerase inhibitors (- 0.8 mm/year; p = .17) and anti-androgens (- 0.5 mm/year; p = .27) showed a possible trend for reduced growth. Similar observations were noted for iliac aneurysms (n = 85). Additionally, the effects persisted for chemotherapy combinations (2.6 ± 1.4 substances/patient). CONCLUSION: Patients with cancer and concomitant aortic aneurysms may require intensified monitoring when undergoing specific therapies, such as antimetabolite treatment, as they may experience an increased aneurysm growth rate. Radiation may be associated with reduced aneurysm growth.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Ilíaco , Neoplasias , Humanos , Masculino , Idoso , Feminino , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aneurisma da Aorta Abdominal/complicações , Aneurisma Ilíaco/complicações , Estudos de Coortes , Neoplasias/complicações
14.
BMC Musculoskelet Disord ; 23(1): 122, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35123466

RESUMO

BACKGROUND: To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with suspected shoulder pathology. METHODS: 3 T MRI of the shoulder including a 3D T1-weighted gradient echo sequence was performed in 25 patients (mean age 52.4 ± 18 years, 13 women) with suspected shoulder pathology. Subsequently a cone-beam forward projection algorithm was used to obtain intensity-inverted CT-like images and simulated radiographs. Two radiologists evaluated the simulated images separately and independently using the conventional radiographs as the standard of reference, including measurements of the image quality, acromiohumeral distance, critical shoulder angle, degenerative joint changes and the acromial type. Additionally, the CT-like MR images were evaluated for glenoid defects, subcortical cysts and calcifications. Agreement between the MR-derived simulated radiographs and conventional radiographs was calculated using Cohen's Kappa. RESULTS: Measurements on simulated radiographs and conventional radiographs overall showed a substantial to almost perfect inter- and intra-rater agreement (κ = 0.69-1.00 and κ = 0.65-0.85, respectively). Image quality of the simulated radiographs was rated good to excellent (1.6 ± 0.7 and 1.8 ± 0.6, respectively) by the radiologists. A substantial agreement was found regarding diagnostically relevant features, assessed on Y- and anteroposterior projections (κ = 0.84 and κ = 0.69 for the measurement of the CSA; κ = 0.95 and κ = 0.60 for the measurement of the AHD; κ = 0.77 and κ = 0.77 for grading of the Samilson-Prieto classification; κ = 0.83 and κ = 0.67 for the grading of the Bigliani classification, respectively). CONCLUSION: In this proof-of-concept study, clinically relevant features of the shoulder joint were assessed reliably using MR-derived CT-like images and simulated radiographs with an image quality equivalent to conventional radiographs. MR-derived CT-like images and simulated radiographs may provide useful diagnostic information while reducing the amount of radiation exposure.


Assuntos
Imageamento por Ressonância Magnética , Dor de Ombro , Acrômio , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Dor de Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
15.
Clin Anat ; 35(3): 296-304, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34837270

RESUMO

Visceral artery aneurysms (VAA) are a rare entity of arterial aneurysms with the imminent threat of rupture. The impact of cancer and chemotherapy on the growth of VAAs is unknown. A retrospective dual center cohort study of patients with concomitant VAA and different types of cancer was conducted and the impact of various chemotherapeutic agents on VAA growth was studied by sequential CT analysis. For comparison, a non-cancer all comer cohort with VAAs and no cancer was studied to compare different growth rates. The primary endpoint was aneurysm progress or regression >1.75 mm. Chi-square test, Fisher's exact test and Mann-Whitney test was used for statistical comparison. In the 17-year-period from January 2003 to March 2020, 59 patients with 30 splenic artery aneurysms, 14 celiac trunk aneurysms, 11 renal artery aneurysms and 4 other VAA and additional malignancy were identified. 20% of patients suffered from prostate cancer, the rest were heterogeneous. The most prevalent chemotherapies were alkylating agents (23%), antimetabolites (14%) and mitose inhibitors (10%). Eight patients had relevant growth of their VAA and one patient showed diameter regression (average growth rate 0.1 ± 0.5 mm/year). Twenty-nine patients with 14 splenic, 11 RAAs (seven right) and 4 celiac trunk aneurysms were available in the non-cancer comparison cohort (average growth rate 0.5 ± 0.9 mm/year, p = 0.058). However, the growth rate of patients receiving operative treatment for relevant VAA growth was significantly higher (p = 0.004). VAAs grow rarely, and rather slow. Cancer and/or chemotherapy do not significantly influence the annual growth rate. Additional control examinations seem unnecessary.


Assuntos
Aneurisma , Neoplasias , Aneurisma/terapia , Artérias , Estudos de Coortes , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Vísceras/irrigação sanguínea
16.
Radiology ; 300(1): 110-119, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33876973

RESUMO

Background Dual-energy CT (DECT) shows promising performance in detecting bone marrow edema (BME) associated with vertebral body fractures. However, the optimal technical and image interpretation parameters are not well described. Purpose To conduct a systematic review and meta-analysis to determine the diagnostic performance of DECT in detecting BME associated with vertebral fractures (VFs), using different technical and image interpretation parameters, compared with MRI as the reference standard. Materials and Methods A systematic literature search was performed on July 9, 2020, to identify studies evaluating DECT performance for in vivo detection of vertebral BME. A random-effects model was used to derive estimates of the diagnostic accuracy parameters of DECT. The impact of relevant covariates in technical, image interpretation, and study design parameters on the diagnostic performance of DECT was investigated using subgroup analyses. Results Seventeen studies (with 742 of 2468 vertebrae with BME at MRI) met inclusion criteria. Pooled estimates of sensitivity, specificity, and area under the curve of DECT for vertebral body BME were 89% (95% CI: 84%, 92%), 96% (95% CI: 92%, 98%), and 96% (95% CI: 94%, 97%), respectively. Single-source consecutive scanning showed poor specificity (78%) compared with the dual-source technique (98%, P < .001). Specificity was higher using bone and soft-tissue kernels (98%) compared with using only soft-tissue kernels (90%, P = .001). Qualitative assessment had a better specificity (97%) versus quantitative assessment (90%) of DECT images (P = .01). Experienced readers showed considerably higher specificity (96%) compared with trainees (79%, P = .01). DECT sensitivity improved using a higher difference between low- and high-energy spectra (90% vs 83%, P = .04). Conclusion Given its high specificity, the detection of vertebral bone marrow edema with dual-energy CT (DECT) associated with vertebral fracture may obviate confirmatory MRI in an emergency setting. Technical parameters, such as the dual-source technique, both bone and soft-tissue kernels, and qualitative assessment by experienced readers, can ensure the high specificity of DECT. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
Doenças da Medula Óssea/complicações , Doenças da Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Fraturas da Coluna Vertebral/complicações , Tomografia Computadorizada por Raios X/métodos , Medula Óssea/diagnóstico por imagem , Edema/etiologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Magn Reson Med ; 85(4): 2001-2015, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33251655

RESUMO

PURPOSE: UTE sequences typically acquire data during the ramping up of the gradient fields, which makes UTE imaging prone to eddy current and system delay effects. The purpose of this work was to use a simple gradient impulse response function (GIRF) measurement to estimate the real readout gradient waveform and to demonstrate that precise knowledge of the gradient waveform is important in the context of high-resolution UTE musculoskeletal imaging. METHODS: The GIRF was measured using the standard hardware of a 3 Tesla scanner and applied on 3D radial UTE data (TE: 0.14 ms). Experiments were performed on a phantom, in vivo on a healthy knee, and in vivo on patients with spine fractures. UTE images were reconstructed twice, first using the GIRF-corrected gradient waveforms and second using nominal-corrected waveforms, correcting for the low-pass filter characteristic of the gradient chain. RESULTS: Images reconstructed with the nominal-corrected gradient waveforms exhibited blurring and showed edge artifacts. The blurring and the edge artifacts were reduced when the GIRF-corrected gradient waveforms were used, as shown in single-UTE phantom scans and in vivo dual-UTE gradient-echo scans in the knee. Further, the importance of the GIRF-based correction was indicated in UTE images of the lumbar spine, where thin bone structures disappeared when the nominal correction was employed. CONCLUSION: The presented GIRF-based trajectory correction method using standard scanner hardware can improve the quality of high-resolution UTE musculoskeletal imaging.


Assuntos
Processamento de Imagem Assistida por Computador , Sistema Musculoesquelético , Artefatos , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
18.
Eur Radiol ; 31(7): 4680-4689, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33443599

RESUMO

OBJECTIVES: To evaluate the performance of 3D T1w spoiled gradient-echo (T1SGRE) and ultra-short echo time (UTE) MRI sequences for the detection and assessment of vertebral fractures and degenerative bone changes compared with conventional CT. METHODS: Fractures (n = 44) and degenerative changes (n = 60 spinal segments) were evaluated in 30 patients (65 ± 14 years, 18 women) on CT and 3-T MRI, including CT-like images derived from T1SGRE and UTE. Two radiologists evaluated morphological features on both modalities: Genant and AO/Magerl classifications, anterior/posterior vertebral height, fracture age; disc height, neuroforaminal diameter, grades of spondylolisthesis, osteophytes, sclerosis, and facet joint degeneration. Diagnostic accuracy and agreement between MRI and CT and between radiologists were assessed using crosstabs, weighted κ, and intraclass correlation coefficients. Image quality was graded on a Likert scale. RESULTS: For fracture detection, sensitivity, specificity, and accuracy were 0.95, 0.98, and 0.97 for T1SGRE and 0.91, 0.96, and 0.95 for UTE. Agreement between T1SGRE and CT was substantial to excellent (e.g., Genant: κ, 0.92 [95% confidence interval, 0.83-1.00]; AO/Magerl: κ, 0.90 [0.76-1.00]; osteophytes: κ, 0.91 [0.82-1.00]; sclerosis: κ, 0.68 [0.48-0.88]; spondylolisthesis: ICCs, 0.99 [0.99-1.00]). Agreement between UTE and CT was lower, ranging from moderate (e.g., sclerosis: κ, 0.43 [0.26-0.60]) to excellent (spondylolisthesis: ICC, 0.99 [0.99-1.00]). Inter-reader agreement was substantial to excellent (0.52-1.00), respectively, for all parameters. Median image quality of T1SGRE was rated significantly higher than that of UTE (p < 0.001). CONCLUSIONS: Morphologic assessment of bone pathologies of the spine using MRI was feasible and comparable to CT, with T1SGRE being more robust than UTE. KEY POINTS: • Vertebral fractures and degenerative bone changes can be assessed on CT-like MR images, with 3D T1w spoiled gradient-echo-based images showing a high diagnostic accuracy and agreement with CT. • This could enable MRI to precisely assess bone morphology, and 3D T1SGRE MRI sequences may substitute additional spinal CT examinations in the future. • Image quality and robustness of T1SGRE sequences are higher than those of UTE MRI for the assessment of bone structures.


Assuntos
Fraturas da Coluna Vertebral , Tomografia Computadorizada por Raios X , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/diagnóstico por imagem
19.
Eur Radiol ; 31(5): 3147-3155, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33052464

RESUMO

OBJECTIVES: Osteoporosis remains under-diagnosed, which may be improved by opportunistic bone mineral density (BMD) measurements on CT. However, correcting for the influence of intravenous iodine-based contrast agent is challenging. The purpose of this study was to assess the diagnostic accuracy of iodine-corrected vertebral BMD measurements derived from non-dedicated contrast-enhanced phantomless dual-layer spectral CT (DLCT) examinations. METHODS: Vertebral volumetric DLCT-BMD was measured in native, arterial, and portal-venous scans of 132 patients (63 ± 16 years; 32% women) using virtual monoenergetic images (50 and 200 keV). For comparison, conventional BMD was determined using an asynchronous QCT calibration. Additionally, iodine densities were measured in the abdominal aorta (AA), inferior vena cava, and vena portae (VP) on each CT phase to adjust for iodine-related measurement errors in multivariable linear regressions and a generalized estimated equation, and conversion equations were calculated. RESULTS: BMD values derived from contrast-enhanced phases using conversion equations adjusted for individual vessel iodine concentrations of VP and/or AA showed a high agreement with those from non-enhanced scans in Bland-Altman plots. Mean absolute errors (MAE) of DLCT-BMD were 3.57 mg/ml for the arterial (R2 = 0.989) and 3.69 mg/ml for the portal-venous phase (R2 = 0.987) (conventional BMD: 4.70 [R2 = 0.983] and 5.15 mg/ml [R2 = 0.981]). In the phase-independent analysis, MAE was 4.49 mg/ml for DLCT (R2 = 0.989) (conventional BMD: 4.82 mg/ml [R2 = 0.981]). CONCLUSIONS: Converted BMD derived from contrast-enhanced DLCT examinations and adjusted for individual vessel iodine concentrations showed a high agreement with non-enhanced DLCT-BMD, suggesting that opportunistic BMD measurements are feasible even in non-dedicated contrast-enhanced DLCT examinations. KEY POINTS: • Accurate BMD values can be converted from contrast-enhanced DLCT scans, independent from the used scan phase. • DLCT-BMD measurements from contrast-enhanced scans should be adjusted with iodine concentrations of portal vein and/or abdominal aorta, which significantly improves the goodness-of-fit of conversion models.


Assuntos
Densidade Óssea , Osteoporose , Feminino , Humanos , Masculino , Programas de Rastreamento , Osteoporose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
20.
Skeletal Radiol ; 50(3): 551-558, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32901305

RESUMO

PURPOSE: (i) To investigate the frequency and natural evolution of meniscal ramp lesions (MRLs) on MRI in subjects with acute ACL tear and (ii) to compare knee cartilage compositional degeneration between subjects with MRLs and subjects without meniscal pathology over 2 years. MATERIALS AND METHODS: Fifty-seven subjects with ACL tears (32 females; age 32.6 ± 8.3 years; BMI 24.5 ± 3.5 kg/m2) from a prospective study were screened for the presence of MRLs. Morphological (high-resolution 3D fast spin-echo) and compositional (T1ρ and T2 mapping) MRI was performed prior to and 2 years after ACL reconstruction. Follow-up MR images were assessed for changes in the signal intensity of the MRLs and the presence of meniscal tears. Differences of compositional parameters were compared between subjects with MRLs and without meniscal lesions using independent samples t tests. RESULTS: MRLs were found in 16% (9/56) of the subjects with ACL tears at baseline. Only one subject with MRLs developed a posterior horn meniscal tear over 2 years. In 12 knees, no meniscal tears were found, which were defined as controls. Most interestingly, cartilage ∆T1ρ of the medial femur and medial tibia increased significantly more in subjects with MRLs compared with controls (mean difference, MF = 6.0 ± 0.8 vs. 2.3 ± 0.6, p = 0.004, and MT = 4.4 ± 1.4 vs. 0.4 ± 0.6, p = 0.027) and medial femur ∆T2 over 2 years increased significantly more in MRL than in control knees (5.1 ± 2.5 ms vs. 2.2 ± 1.9 ms, p = 0.012). CONCLUSION: Subjects with ACL tear presented MRLs in 16% of cases. Compared with controls without meniscal lesions, knees with MRLs demonstrated accelerated degeneration of cartilage composition in the medial knee compartment over 2 years.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Adulto , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Cartilagem , Feminino , Humanos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Meniscos Tibiais , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA