Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Science ; 165(3889): 180-4, 1969 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-17834741

RESUMO

We measured the emission of water vapor at a wavelength of 1.35 centimeters from nine sources with the 120-foot (36.5-meter) Haystack antenna. Eight sources lie within 30 seconds of arc of the hydroxyl sources of 18 centimeters but not all hydroxyl sources produced detectable emission of water vapor. All sources are smaller than 30 seconds of arc in angular diameter, but we resolved at least three separate sources in the Orion Nebula. We do not find that the known hyperfine components are present with the equilibrium intensity distribution.

2.
Astrophys J ; 319(1): 426-35, 1987 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-11539740

RESUMO

We present observations of the 1300 micron continuum emission and the C18O spectral-line emission from three well-studied giant molecular cloud cores: Orion, W49, and W51. The observations were obtained at the Five College Radio Astronomy Observatory, and they provide a means to examine the consistency of these two methods to trace the column density structure of molecular clouds. We find a good general correlation between the 1300 micron continuum, which traces the column density of dust, and the C18O J = 2 --> 1 line emission, which traces the column density of molecular gas, when the effects of source temperature are taken into consideration. Moreover, nominal values for the gas and dust abundances and the dust properties reproduce the observed continuum-to-line ratios. Thus, no strong C18O abundance gradients within sources has been found, and it appears that either the C18O emission lines or the submillimeter dust emission may be used to derive the mass column density within molecular clouds accurately.


Assuntos
Astronomia , Monóxido de Carbono/química , Poeira Cósmica/análise , Meio Ambiente Extraterreno , Gases/análise , Fenômenos Astronômicos , Modelos Teóricos , Isótopos de Oxigênio , Análise Espectral , Temperatura
3.
Astrophys J ; 336(1): 519-25, 1989 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-11538349

RESUMO

In this paper we present nearly simultaneous 1300 microns continuum and J = 2-1 C18O maps of the cores of five molecular clouds, W3, NGC 2264, NGC 6334I, rho Oph, and S140. The purpose of this experiment was to compare these two column density tracers. We find that dust continuum and C18O emission are equally effective tracers of column density in molecular cloud cores and give a good indication of cloud structure. When the maps are analyzed in terms of the quantity q = Q/[a rho RX(C18O)], we find that q does not vary by much more than an order of magnitude either within objects or from object to object, implying that nominal dust parameters of absorption efficiency, radius, and gas-to-dust ratio and CO abundance are on average correct in a variety of sources. We did detect source-to-source variations in q. This variation could be either in the dust-to-CO number density ratio or in grain parameters. These variations are not well correlated with total source luminosity, average or typical temperature, or total column density. The best example of this variation appears to be rho Oph where q is about a factor of 7 lower than is typically found. Our approach is analogous to the study of the A nu to CO ratio and is probably equivalent to extending this study to large A nu if the same grains are responsible for both optical opacity and far-infrared to millimeter-wave emission. There is no fundamental reason to expect A nu/NCO or q to be constant and, in fact, we have found that it is not constant in even a small source sample.


Assuntos
Carbono , Poeira/análise , Meio Ambiente Extraterreno , Gases/análise , Fenômenos Astronômicos , Astronomia , Fenômenos Químicos , Química , Isótopos de Oxigênio , Análise Espectral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA