Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Anal Chem ; 95(4): 2134-2139, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36649064

RESUMO

A polymer inclusion membrane (PIM) based sampling probe was developed for electrokinetic extraction of drugs from biological fluids. The probe was fabricated by dip-coating a nonconductive glass capillary tube in a homogeneous PIM solution for three cycles. The PIM solution comprised cellulose triacetate (CTA), 2-nitrophenyl octyl ether (NPOE), and 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [EMIM][NTf2] in a ratio of 5:4:2. The developed probe electrokinetically extracted doxorubicin from human plasma, human serum, and dried blood spot (DBS). The practicability and reliability of the electrokinetic extraction were evaluated by LC-MS/MS to quantify the desorption of extracted doxorubicin. Under the optimized conditions, a quantification limit of 0.2-2 ng/mL was achieved for the three biological samples. The probe was further integrated into a portable battery-powered device for safe low-voltage (36 V) electrokinetic extraction. The developed technique is envisioned to provide a more efficient analytical workflow in the laboratory.


Assuntos
Polímeros , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida , Reprodutibilidade dos Testes
2.
Environ Sci Technol ; 57(50): 21038-21049, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38064758

RESUMO

Microplastic fibers from textiles have been known to significantly contribute to marine microplastic pollution. However, little is known about the microfiber formation and discharge during textile production. In this study, we have quantified microfiber emissions from one large and representative textile factory during different stages, spanning seven different materials, including cotton, polyester, and blended fabrics, to further guide control strategies. Wet-processing steps released up to 25 times more microfibers than home laundering, with dyeing contributing to 95.0% of the total emissions. Microfiber release could be reduced by using white coloring, a lower dyeing temperature, and a shorter dyeing duration. Thinner, denser yarns increased microfiber pollution, whereas using tightly twisted fibers mitigated release. Globally, wet textile processing potentially produced 6.4 kt of microfibers in 2020, with China, India, and the US as significant contributors. The study underlined the environmental impact of textile production and the need for mitigation strategies, particularly in dyeing processes and fiber choice. In addition, no significant difference was observed between the virgin polyesters and the used ones. Replacing virgin fibers with recycled fibers in polyester fabrics, due to their increasing consumption, might offer another potential solution. The findings highlighted the substantial impact of textile production on microfiber released into the environment, and optimization of material selection, knitting technologies, production processing, and recycled materials could be effective mitigation strategies.


Assuntos
Microplásticos , Plásticos , Têxteis , Poliésteres , Meio Ambiente , Indústria Têxtil
3.
Electrophoresis ; 40(3): 455-461, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30450561

RESUMO

A new multi-stacking pre-concentration procedure based on field-enhanced sample injection (FESI), field-amplified sample stacking, and transient isotachophoresis was developed and implemented in a compact microchip electrophoresis (MCE) with a double T-junction glass chip, coupled with an on-chip capacitively coupled contactless conductivity detection (C4 D) system. A mixture of the cationic target analyte and the terminating electrolyte (TE) from the two sample reservoirs was injected under FESI conditions within the two sample-loading channels. At the double T-junction, the stacked analyte zones were further concentrated under field-amplified stacking conditions and then subsequently focused by transient-isotachophoresis and separated along the separation channels. The proposed multi-stacking strategy was verified under a Universal Serial Bus (USB) fluorescence microscope employing Rhodamine 6G as the model analyte. This developed approach was subsequently used to monitor the target quinine present in human plasma samples. The total analysis time for quinine was approximately 200 s with a sensitivity enhancement factor of approximately 61 when compared to the typical gated injection. The detection and quantification limits of the developed approach for quinine were 3.0 µg/mL and 10 µg/mL, respectively, with intraday and interday repeatability (%RSDs, n = 5) of 3.6 and 4.4%. Recoveries in spiked human plasma were 98.1-99.8%.


Assuntos
Análise Química do Sangue/instrumentação , Eletroforese em Microchip/instrumentação , Quinina/sangue , Análise Química do Sangue/métodos , Eletroforese em Microchip/métodos , Desenho de Equipamento , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
4.
Electrophoresis ; 40(1): 17-39, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30362581

RESUMO

One of the most cited limitations of capillary and microchip electrophoresis is the poor sensitivity. This review continues to update this series of biannual reviews, first published in Electrophoresis in 2007, on developments in the field of online/in-line concentration methods in capillaries and microchips, covering the period July 2016-June 2018. It includes developments in the field of stacking, covering all methods from field-amplified sample stacking and large-volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to online or in-line extraction methods that have been used for electrophoresis.


Assuntos
Eletroforese Capilar , Animais , Biomarcadores/análise , Linhagem Celular , Fracionamento Químico , Humanos , Concentração de Íons de Hidrogênio , Isotacoforese , Camundongos , Micelas , Sensibilidade e Especificidade
5.
Angew Chem Int Ed Engl ; 58(12): 3790-3794, 2019 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-30614157

RESUMO

An electrokinetic platform was developed for extracting small-molecule pharmaceuticals from a dried blood spot. Through the exclusion of liquid reagents and use of low field strength (6 V cm-1 ), the electroextraction of a drug from a dried blood spot, deposited on a polymer inclusion membrane (PIM), could be realised while in transit in the mail. In transit sample preparation provides a potential solution to in situ sample degradation and may accelerate the workflow upon arrival of a patient sample at the analytical facility. The electroextraction method was enabled through our discovery of the use of 15-20 µm thin PIMs as electrophoretic separation medium in absence of liquid reagents. Here, a PIM consisting of cellulose triacetate as polymer base, 2-nitrophenyl octyl ether as plasticizer and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide as carrier was used. The PIM, was packaged with two 12 V batteries to supply the separation voltage. A blood spot containing berberine chloride was deposited and dried before the applying the separation potential, allowing for the electroextraction while the packaged device was shipped in internal mail. Upon arrival in the analytical laboratory, the PIM was analysed using a fluorescence microscope with photon multiplier tube, quantifying the berberine extracted away from the sample matrix. This platform represents a new opportunity for processing clinical samples during transport to the laboratory, saving time and manual handling to accelerate the time to result.


Assuntos
Berberina/sangue , Eletroforese/métodos , Berberina/isolamento & purificação , Celulose/análogos & derivados , Celulose/química , Teste em Amostras de Sangue Seco , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Polímeros/química
6.
Molecules ; 23(5)2018 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-29695126

RESUMO

A method for on-line matrix elimination to enable selective quantification of ultraviolet absorbing analytes by a flow-injection analysis procedure is described. Selectivity is achieved by electric field driven extraction across a polymer inclusion membrane. The method was demonstrated on the example of the determination of naproxen from spiked human urine. Membranes of 10 µm thickness were employed which consisted of 7.5 mg cellulose triacetate as base polymer, 5 mg of o-nitrophenyl octyl ether as plasticizer and 7.5 mg of Aliquat 336 as cationic carrier. Ten µL of sample was introduced into a continuous stream of background solution consisting of 100 µM aqueous NaClO4 with a flow rate of 2 µL/min while applying a voltage of 150 V to the extraction cell. The target ion was electrokinetically transported across the membrane and enriched in 1.5 µL of a stagnant acceptor solution. This was subsequently pumped past a flow-through UV detector for quantification. The method showed a linear range from 5 to 200 µM with a correlation coefficient of 0.9978 and a reproducibility of typically 7% (n = 8). The detection limit of the method for naproxen was 2 µM.


Assuntos
Análise de Injeção de Fluxo , Modelos Teóricos , Humanos
7.
Electrophoresis ; 38(1): 33-59, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27678139

RESUMO

One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biennial reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods in capillaries and microchips, covering the period July 2014-June 2016. It includes developments in the field of stacking, covering all methods from field amplified sample stacking and large volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.


Assuntos
Eletroforese Capilar/métodos , Isotacoforese/métodos , Procedimentos Analíticos em Microchip/métodos , Eletrocromatografia Capilar , Linhagem Celular , Humanos , Compostos Inorgânicos/análise , Focalização Isoelétrica , Nanoestruturas/análise , Compostos Orgânicos/análise , Sensibilidade e Especificidade
8.
Anal Chem ; 88(20): 9915-9919, 2016 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-27669824

RESUMO

The translation of stacking techniques used in capillary electrophoresis (CE) to microchip CE (MCE) in order to improve concentration sensitivity is an important area of study. The success in stacking relies on the generation and control of the stacking boundaries which is a challenge in MCE because the manipulation of solutions is not as straightforward as in CE with a single channel. Here, a simple and rapid online sample concentration (stacking strategy) in a battery operated nonaqueous MCE device with a commercially available double T-junction glass chip is presented. A multistacking approach was developed in order to circumvent the issues for stacking in nonaqueous MCE. The cationic analytes from the two loading channels were injected under field-enhanced conditions and were focused by micelle-to-solvent stacking. This was achieved by the application of high electric fields along the two loading channels and a low electric field in the separation channel, with one ground electrode in the reservoir closest to the junction. At the junction, the stacked zones were restacked under field-enhanced conditions and then injected into the separation channels. The multistacking was verified under a fluorescence microscope using Rhodamine 6G as the analyte, revealing a sensitivity enhancement factor (SEF) of 110. The stacking approach was also implemented in the nonaqueous MCE with contactless conductivity detection of the anticancer drug tamoxifen as well as its metabolites. The multistacking and analysis time was 40 and 110 s, respectively, the limit of detections was from 10 to 35 ng/mL and the SEFs were 20 to 50. The method was able to quantify the target analytes from breast cancer patients.

9.
Electrophoresis ; 37(9): 1166-9, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26873060

RESUMO

Micelle to solvent stacking was implemented for the recently established NACE-C(4) D method to determine tamoxifen and its metabolites in standard samples and human plasma of breast cancer patients. For stacking, the standard samples and extract after liquid-liquid extraction (LLE) were prepared in methanol and the resulting sample solution was pressure injected after a micellar plug of SDS. Factors that affected the stacking such as SDS concentration, micelle, and sample plug length were examined. The sensitivity enhancement factor (peak height from stacking/peak height from typical injection of sample in BGE) was 15-22. The method detection limits with LLE were in the range of 5-10 ng/mL, which was lower than the established method (where the LLE extract was also prepared in methanol) with reported method detection limits of 25-40 ng/mL. The intraday and interday repeatability were in the range of 1.0-3.4% and 3.8-6.5%, respectively.


Assuntos
Eletroforese Capilar/métodos , Micelas , Tamoxifeno/análise , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Tamoxifeno/sangue
10.
Electrophoresis ; 36(21-22): 2713-2719, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26174155

RESUMO

A new approach for the quantification of tamoxifen and its metabolites 4-hydroxytamoxifen, N-desmethyltamoxifen, and 4-hydroxy-N-desmethyltamoxifen (endoxifen) in human plasma samples using NACE coupled with contactless conductivity detection (C4 D) is presented. The buffer system employed consisted of 7.5 mM deoxycholic acid sodium salt, 15 mM acetic acid, and 1 mM 18-crown-6 in 100% methanol. The complete separation of all targeted compounds (including endoxifen racemate) could be achieved within 6 min under optimized conditions. The proposed method was validated and showed good linearity in the range from 100 to 5000 ng/mL with correlation coefficients between 0.9922 and 0.9973, LODs in the range of 25-40 ng/mL, and acceptable reproducibility of the peak area (intraday RSD 2.2-3.1%, n = 4; interday (3 days) RSD 6.0-8.8%, n = 4). The developed method was successfully demonstrated for the quantification of tamoxifen and its metabolites in human plasma samples collected from breast cancer patients undertaking tamoxifen treatment.

11.
Electrophoresis ; 36(1): 36-61, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25330057

RESUMO

One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biannual reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods, covering the period July 2012-July 2014. It includes developments in the field of stacking, covering all methods from field-amplified sample stacking and large-volume sample stacking, through to ITP, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.


Assuntos
Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Animais , Desenho de Equipamento , Humanos , Concentração de Íons de Hidrogênio , Extração Líquido-Líquido/instrumentação , Extração Líquido-Líquido/métodos , Tamanho da Amostra , Sensibilidade e Especificidade , Extração em Fase Sólida/instrumentação , Extração em Fase Sólida/métodos
12.
Anal Chem ; 86(17): 8665-70, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25111065

RESUMO

An automated analyte electroextraction and preconcentration system, which was used as the front end for a liquid chromatography-electrospray mass spectrometry instrument, is described. The extraction was based on driving the anionic analytes across a polymer inclusion membrane by application of a potential of 200 V to the cell. Five milliliters (5 mL) of sample were passed through a flow-through cell at a flow rate of 0.2 mL/min containing a membrane 20 µm thick. This consisted of 75% cellulose triacetate as base polymer, 12.5% of tris(2-ethylhexyl)phosphate as plasticizer, and 12.5% of Aliquat 336 as cationic carrier. The target analytes were enriched in 20 µL of a stagnant acceptor solution prior to online LC/MS analysis. The performance of the system was demonstrated for the determination of chlorinated phenoxyacetic acid herbicides in spiked river water. Enrichment factors of ~200 were achieved with recoveries of typically 99% and precision values of typically 5%. The limit of detection (LOD) values were found to be between 0.03 ng/mL to 0.08 ng/mL.

13.
Crit Rev Anal Chem ; : 1-22, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38165816

RESUMO

Sample clean-up and pre-concentration are critical components of pharmaceutical analysis. The dispersive liquid-liquid microextraction (DLLME) technique is widely recognized as the most effective approach for enhancing overall detection sensitivity. While various DLLME modes have been advanced in pharmaceutical analysis, there need to be more discussions on pre-concentration techniques specifically developed for this field. This review presents a comprehensive overview of the different DLLME modes used in pharmaceutical analysis from 2017 to May 2023. The review covers the principles of DLLME, the factors affecting microextraction, the selected applications of different DLLME modes, and their advantages and disadvantages. Additionally, it focuses on multi-extraction strategies employed for pharmaceutical analysis.

14.
Carbohydr Polym ; 337: 121969, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38710542

RESUMO

Practical benefits of graphene-cellulose composites (GCC) are categorical. Diverse salient features like thermal and electrical conductivity, mechanical strength, and durability make GCC advantageous for widespread applications. Despite extensive studies the basic understanding of various fundamental aspects of this novel complex remains deficient. Based on this fact, a critical overview and bibliometric analysis involving the overall prospects of GCC was made wherein a total of 1245 research articles from the Scopus database published during the year 2002 to 2020 were used. For the bibliometric assessment, various criteria including the publication outputs, co-authorships, affiliated countries, and co-occurrences of the authors' keywords were explored. Environmental amiability, sustainability, economy, and energy efficiency of GCC were emphasized. In addition, the recent trends, upcoming challenges, and applied interests of GCC were highlighted. The findings revealed that the studies on GCC related to the energy storage, adsorption, sensing, and printing are ever-increasing, indicating the global research drifts on GCC. The bibliometric map analysis displayed that among the researchers from 61 countries/territories, China alone contributed about 50 % of the international publications. It is asserted that the current article may offer taxonomy to navigate into the field of GCC wherein stronger collaboration networks can be established worldwide through integrated research activities desirable for sustainable development.

15.
Electrophoresis ; 34(2): 317-23, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23161565

RESUMO

A study on the separation of lipophilic quaternary ammonium cations in NACE coupled with contactless conductivity detection (NACE-C(4)D) is presented. The suitability of different salts dissolved in various organic solvents as running electrolytes in NACE-C(4)D was investigated. A solvent mixture of methanol/acetonitrile at a ratio of 90%:10% v/v showed the best results. Deoxycholic acid sodium salt as BGE was found to provide exceptional high stability with low baseline noise that leads to highest S/N ratios for the target analytes among all BGEs tested. Under the optimum conditions, capillaries with different internal diameters were examined and an id of 50 µm was found to give best detection sensitivity. The proposed method was validated and showed good linearity in the range from 2.5 to 200 µM, low limits of detection (0.1-0.7 µM) and acceptable reproducibility of peak area (intraday RSD 0.1-0.7%, n = 3; interday RSD 5.9-9.4%, n = 3).


Assuntos
Eletrólitos/química , Eletroforese Capilar/métodos , Compostos de Amônio Quaternário/química , Solventes/química , Acetonitrilas/química , Cátions/análise , Ácido Desoxicólico/química , Condutividade Elétrica , Limite de Detecção , Metanol/química , Reprodutibilidade dos Testes
16.
Electrophoresis ; 34(14): 2072-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23797990

RESUMO

The determination of fatty acids by nonaqueous CZE with capacitively coupled contactless conductivity detection was investigated. A new deoxycholate-based BGE, which had previously been found to give significantly improved baseline stability in the determination of lipophilic organic ammonium ions, was found to be similarly beneficial for the determination of the anions. The use of a PVA-coated capillary was required for suppression of the EOF and to obtain well reproducible results. The complete separation of 12 fatty acids could be achieved with 10 mM DOC in methanol within 6 min under optimized conditions. The PVA-coated capillary demonstrated outstanding stability over 300 runs with no sign of depletion of the PVA layer. Method validation showed a good linearity range from 0.75 to 25 µM with correlation coefficients between 0.9949 and 0.9979. The LOD was determined as 0.5 µM for all fatty acids. The developed approach was successfully demonstrated for the separation of free fatty acids in commercial and home-made edible oil.


Assuntos
Eletroforese Capilar/métodos , Ácidos Graxos/isolamento & purificação , Álcool de Polivinil/química , Gorduras Insaturadas na Dieta/análise , Condutividade Elétrica , Limite de Detecção , Dióxido de Silício/química
17.
J Chromatogr A ; 1685: 463605, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36375217

RESUMO

A new dispersive inclusion complex microextraction (DICM) approach coupled with ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the determination of n-nitrosamine impurities in different medicinal products is demonstrated for the first time. The proposed DICM procedures consist of a dispersive liquid phase microextraction steps employing cyclodextrin as an inclusion complex agent to extract n-nitrosamines namely N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA), N-nitrosodiisopropylamine (NDIPA), N-ethyl-N-nitrosoisopropylamine (NEIPA) and N-nitroso-di-n-butylamine (NDBA) present in the medicinal products. The sample solutions were prepared by mixing 5% (m/v) NaCl solution with 1.5 mM ß-cyclodextrin and 20 mM sodium dodecyl sulphate to form a stable inclusion complex and subsequently extracted into dichloromethane as an extraction solvent. The enriched solution was reconstituted into aqueous solution prior to UPLC-MS/MS analysis. The method showed good linearity in the range of 0.036-1 ng/mL with a correlation coefficient of at least 0.995, acceptable reproducibility (RSD 0.5-5.8%, n=5), low limits of detection (0.011-0.018 ng/mL), and satisfactory relative recoveries (96-105%). The results obtained were found to be at least 10-fold more sensitive comparable to those obtained using validated direct sample dissolutions coupled with UPLC-MS/MS approach.


Assuntos
Microextração em Fase Líquida , Nitrosaminas , Nitrosaminas/análise , Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Microextração em Fase Líquida/métodos , Dimetilnitrosamina/análise
18.
J Pharm Sci ; 111(12): 3318-3326, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36028135

RESUMO

Drug-drug cocrystalllization is a novel mechanism for effective pharmacological combination therapy. In this work, we have demonstrated the preparation of a drug-drug cocrystal of a hypertension drug (Telmisartan; TEL) with a hyperuricemia drug (Febuxostat; FEB) in 1:1 molar ratio using a solvent evaporation method for the first time. Generally, a multi-component system may yield either a eutectic, salt, and/or a cocrystal. This study adopted a methodical orthogonal framework to analyze the final solid form. A single crystal X-ray structural investigation revealed the formation of a heterosynthon with carboxylic and benzimidazole groups of FEB and TEL, respectively, in the triclinic P-1 space group. ΔpKa of the heterosynthon is ∼1.5, hence, based on the empirical rules, a salt-cocrystal continuum is hypothesized. Further, attenuated total reflectance Fourier transform infrared (ATR-FTIR), and Raman spectroscopy were employed to corroborate the hydrogen bond formation in the heterosynthon (-N---H-O-), which confirmed the propensity for cocrystal formation. An accelerated stability study and an in vitro biorelevant dissolution study of the cocrystal were performed, which demonstrated that it is physiochemically stable, but it resulted in a slower dissolution rate when compared with plain drugs.


Assuntos
Gota , Hipertensão , Humanos , Febuxostat , Telmisartan , Gota/tratamento farmacológico , Hipertensão/tratamento farmacológico , Terapia Combinada , Cloreto de Sódio na Dieta , Cloreto de Sódio
19.
Anal Chem ; 83(19): 7507-13, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21851124

RESUMO

The use of a cationic carrier-mediated polymer inclusion membrane (PIM) for extraction and preconcentration of anionic model analytes driven by an electric field directly into an aqueous acceptor solution is demonstrated. The optimized membrane was 20 µm thick and consisted of 60% cellulose triacetate as base polymer, 20% o-nitrophenyl octyl ether as plasticizer, and 20% Aliquat 336 as cationic carrier in the perchlorate form. By applying voltages of up to 700 V across the membrane, the lipophilic model analytes propanesulfonate, octanesulfonate, and decanesulfonate could be transported from the aqueous donor solution to the aqueous acceptor solution with efficiences >90% within 5 to 20 min. A preconcentration factor of 26, defined by the volume ratio between donor and acceptor compartments of the current cell design, could be achieved. The utility of the method for analytical applications is demonstrated by extraction of the herbicide glyphosate and its breakdown product aminomethylphosphonic acid from spiked river water, followed by quantification with capillary electrophoresis using contactless conductivity detection. Limits of detection of 0.8 and 1.5 ng/mL were obtained for glyphosate and aminomethylphosphonic acid, respectively.


Assuntos
Alcanossulfonatos/isolamento & purificação , Celulose/análogos & derivados , Fracionamento Químico , Membranas Artificiais , Polímeros/química , Alcanossulfonatos/análise , Ânions/análise , Ânions/isolamento & purificação , Celulose/química , Fracionamento Químico/instrumentação , Eletricidade , Eletroforese Capilar , Água Doce/química , Interações Hidrofóbicas e Hidrofílicas
20.
J Chromatogr A ; 1635: 461731, 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33285415

RESUMO

Conventional sampling of biological fluids often involves a bulk quantity of samples that are tedious to collect, deliver and process. Miniaturized sampling approaches have emerged as promising tools for sample collection due to numerous advantages such as minute sample size, patient friendliness and ease of shipment. This article reviews the applications and advances of microsampling techniques in therapeutic drug monitoring (TDM), covering the period January 2015 - August 2020. As whole blood is the gold standard sampling matrix for TDM, this article comprehensively highlights the most historical microsampling technique, the dried blood spot (DBS), and its development. Advanced developments of DBS, ranging from various automation DBS, paper spray mass spectrometry (PS-MS), 3D dried blood spheroids and volumetric absorptive paper disc (VAPD) and mini-disc (VAPDmini) are discussed. The volumetric absorptive microsampling (VAMS) approach, which overcomes the hematocrit effect associated with the DBS sample, has been employed in recent TDM. The sample collection and sample preparation details in DBS and VAMS are outlined and summarized. This review also delineates the involvement of other biological fluids (plasma, urine, breast milk and saliva) and their miniaturized dried matrix forms in TDM. Specific features and challenges of each microsampling technique are identified and comparison studies are reviewed.


Assuntos
Líquidos Corporais/química , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/tendências , Manejo de Espécimes/métodos , Manejo de Espécimes/tendências , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA