Childs Nerv Syst ; 33(11): 2003-2010, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28689342

RESUMO

PURPOSE AND METHODS: Superselective transvenous embolization (TVE) with liquid embolic agents is a new concept in treatment of vein of Galen aneurysmal malformations (VGAM). We performed ten sessions of TVE in VGAM patients with restricted transarterial access. In this paper, we assessed clinical and angiographic outcomes of the proposed treatment and discussed three different TVE techniques with regard to morphology of the shunt and outflow tract. Safety and avoidance-of-complication tips were also discussed. RESULTS: Patient age ranged from 4 to 51 months. There were eight patients with choroidal VGAMs, seven of them were successfully treated with Onyx, and in one case, transvenous catheterization failed. In three cases, adjunctive coiling of draining vein was performed. In three cases, normal deep cerebral veins were connected to the outflow part of malformation; they were preserved during embolization in all cases. Six-month follow-up angiography demonstrated angiographic cure in six cases, and partial occlusion in one. There were two patients with mural VGAMs: both were treated with n-BCA. Partial occlusion was achieved in both cases. There was no procedure-related permanent morbidity or mortality. Oculomotor deficit due to quadrigeminal ischemia occurred in one case, and resolved completely after 3 weeks. CONCLUSION: TVE with liquid embolic agents is a safe and effective salvage method for VGAMs with restricted transarterial access, previously considered as poor candidates for endovascular treatment.


Assuntos
Embolização Terapêutica/métodos , Malformações da Veia de Galeno/terapia , Adolescente , Adulto , Dimetil Sulfóxido/uso terapêutico , Embucrilato/uso terapêutico , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polivinil/uso terapêutico
2.
J Neurosurg Case Lessons ; 4(16)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36254355

RESUMO

BACKGROUND: Pediatric arteriovenous malformations (AVMs) and pial/dural arteriovenous fistulas (AVFs) are rare but life-threatening complications that can lead to congestive heart failure and hemorrhagic stroke in newborns and pediatric patients. The pronounced shunting in these conditions is associated with early complications and necessitates aggressive surgical management. Here, the authors describe endovascular treatment of an atypical cerebral pial AVF in a newborn. OBSERVATIONS: This AVF formed direct communication between a major cerebral artery (basilar artery) and a large draining vein (dilated deep cerebral vein). The authors performed earlier subtotal embolization of the AVF using 0.020-inch coils, which led to progressive thrombosis of the fistula with restoration of normal arterial blood flow. The patient was discharged 18 days after surgery, examination at 1.5 and 6 months showed magnetic resonance imaging signs of blood flow absence through the fistula and satisfactory condition of the infant without physical and mental developmental delay. LESSONS: Subtotal coiling of a high-flow pial AVF in a newborn can result in a good clinical outcome.

3.
Interv Neuroradiol ; 24(3): 270-273, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29378449

RESUMO

Utilization of flow diverting devices is accompanied with dual antiplatelet therapy to reduce the risk of thromboembolic events, even though this increases the risk of hemorrhagic complications. The updated Pipeline Flex embolization device with Shield Technology has been created using a phosphorylcholine coating that reduces thrombogenicity and possibly reduces the need for dual antiplatelet therapy. However, because of the potential risk to patients of utilizing a pipeline embolization device without dual antiplatelet therapy, the pipeline embolization device with Shield Technology has not been tested in human subjects without dual antiplatelet therapy, and its contribution to preventing thromboembolic events is therefore unknown. We report a case in which a patient, following complications that limited his absorption of dual antiplatelet therapy, had low levels of dual antiplatelet therapy medications in his bloodstream following treatment for an intracranial aneurysm with a pipeline embolization device with Shield Technology. The patient recovered without signs of luminal stenosis or thromboembolic event.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Idoso , Materiais Revestidos Biocompatíveis , Terapia Combinada , Humanos , Masculino
4.
Clin Neurol Neurosurg ; 172: 183-189, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30053620

RESUMO

OBJECTIVE: We performed prospective randomized comparison of clinical and surgical outcomes of flow diversion versus PVO and bypass in patients with complex anterior circulation aneurysms. PATIENTS AND METHODS: Open, prospective, randomized, parallel group, multicenter study of complex intracranial aneurysms treatment was conducted. Patients with complex intracranial aneurysms of anterior circulation with neck is more than 4 mm wide, dome/neck ratio is equal or less than 2:1, which is suitable for flow diversion and occlusion with bypass were included in the study. A total of 111 potential participants were enrolled since March 2015. Additional propensity score matching was performed with 40 patients in each group selected for analysis. RESULTS: 39 out of 40 patients (97.5%) from matched FD group reached good clinical outcome. In the matched bypass group acceptable outcome was achieved in 32 (80%) out of 40 patients (difference between groups p = 0.029). The morbidity and mortality rates were 15% and 5%, respectively. Difference in the rates of favorable outcomes, compared by χ2 met statistical significance (p = 0.014). The rate of complete aneurysm occlusion at 6 months was 42.5% in the FD group and 95% in surgical group (p < 0.0001). The rate of complete occlusion at 12 months was 65% in the FD group and 97.5% in surgical group. The difference between groups was still significant (p = 0.001). There were no significant differences between groups by occurrence of ischemic (p = 0.108) and hemorrhagic (p = 0.615) complications. CONCLUSION: The study demonstrated superior clinical outcomes for endovascular flow diversion in comparison with bypass surgery in treatment of complex aneurysms. Though, both techniques grant similar percentage of major neurologic complications and comparable cure rate for cranial neuropathy. Nevertheless, flow diversion is associated with significantly lower early obliteration rate, thus possesses patient for risks of prolonged dual antiplatelet regimen and delayed rupture. Hence, it's important to stratify patient by the natural risk of aneurysm rupture prior to treatment selection.


Assuntos
Aneurisma Roto/cirurgia , Artérias/cirurgia , Aneurisma Intracraniano/cirurgia , Fatores de Tempo , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Stents , Resultado do Tratamento