Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
BMC Ophthalmol ; 21(1): 253, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34098876

RESUMO

BACKGROUND: Disc hemorrhage (DH) is an important factor often associated with the development and especially progression of glaucoma. In contrast, some studies have reported peripapillary retinoschisis in glaucoma, but it is not recognized as a pathognomonic finding, and opinions on the clinical significance of retinoschisis are not consistent. Here,we present the case of DH following peripapillary retinoschisis in the same area within the same glaucomatous eye. CASE PRESENTATION: A 70-year-old man with high intraocular pressure (IOP) was referred to the glaucoma clinic. At the time of the baseline study, the IOP was 30mmHg, and peripapillary retinoschisis was discovered at 7 o'clock on the periphery of the optic nerve with swept-source optical coherence tomography. Accompanying retinal nerve fiber layer defect were manifest in the inferotemporal part with red-free fundus photography. Under the impression of open-angle glaucoma, we prescribe latanoprost ophthalmic solution. Eight months later, the IOP was 17mmHg, and the peripapillary retinoschisis had disappeared. DH was observed in the inferotemporal area in the same direction as that of the previous peripapillary retinoschisis. CONCLUSIONS: The case presented here are the first to report on the relationship between peripapillary retinoschisis and DH. Hopefully future studies will reveal the actual connection between peripapillary retinoschisis and DH.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Retinosquise , Idoso , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/diagnóstico , Hemorragia , Humanos , Pressão Intraocular , Masculino , Retinosquise/complicações , Retinosquise/diagnóstico , Tomografia de Coerência Óptica
2.
Graefes Arch Clin Exp Ophthalmol ; 255(6): 1193-1202, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28429123

RESUMO

PURPOSE: To investigate peripapillary vessel density at various spatial locations and layers in healthy and normal tension glaucoma eyes using optical coherence tomography angiography (OCTA). METHODS: A commercial OCTA device (AngioPlex; Carl Zeiss Meditec) was used to image microvasculature in a 6 × 6-mm optic disc region. Vessel densities of superficial and deep retinal layers were calculated using an automatic thresholding algorithm. Vessel density maps were plotted by averaging individual angiogram images. The spatial characteristics of vessel densities were analyzed at clock-hour sectors and in five 0.7-mm-thick concentric circles from a diameter of 2.0 to 5.5 mm. Areas under the receiver operating characteristics curves (AUCs) assessed the glaucoma diagnostic ability. RESULTS: Vessel density maps of superficial and deep retinal layers were significantly reduced at the 7 and 11 o'clock positions in glaucomatous eyes. In superficial layer, vessel density significantly decreased as the distance from the optic disc margin increased, except in the innermost circle (2.0-2.7-mm). There were significant differences in AUCs of superficial vessel density between innermost circle and the other outer circles. In the deep layer, the innermost circle showed significantly higher vessel density than the outer circles. Vessel density at 7 o'clock showed the best diagnostic performance (AUCs, 0.898 and 0.789) both in the superficial and deep layers. The innermost circle showed eccentric feature compared to the outer circles in terms of spatial characteristics and diagnostic ability. CONCLUSIONS: Understanding of the spatial characteristics of peripapillary vasculature may be helpful in clinical practice and determining the optimal measurement area of vessel density.


Assuntos
Angiofluoresceinografia/métodos , Glaucoma de Baixa Tensão/diagnóstico , Disco Óptico/irrigação sanguínea , Células Ganglionares da Retina/patologia , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Feminino , Seguimentos , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
BMC Ophthalmol ; 17(1): 182, 2017 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-28974211

RESUMO

BACKGROUND: To quantitatively compare short-term hard exudates (HEs) alteration in patients with diabetic macular edema (DME) after intravitreal triamcinolone, dexamethasone implant or bevacizumab injections. METHODS: This retrospective study enrolled DME eyes with HEs that underwent a single-dose intravitreal injection of triamcinolone (25 eyes), dexamethasone implant (20 eyes), or three monthly injections of bevacizumab (25 eyes) and completed at least three months of follow-up. All patients were examined before and after 1, 2 and 3 months of injections. Using color fundus photographs, the amount of HEs was quantified by two masked graders. The difference in HEs area between baseline and each follow-up visit was compared among the three groups. RESULTS: After three months, HEs area was reduced to 52.9 ± 4.21% (P < 0.001) in the triamcinolone group, 63.6 ± 6.08% (P = 0.002) in the dexamethasone implant group, and 85.2 ± 5.07% (P = 0.198) in the bevacizumab group. A significant reduction in HEs appeared at one month in the triamcinolone group (53.5 ± 4.91%, P < 0.001) and at two months in the dexamethasone implant group (70.1 ± 5.21%, P = 0.039). CONCLUSIONS: Our study suggests intravitreal steroids (triamcinolone, dexamethasone implants) significantly reduce HEs in DME patients on short-term follow-up, whereas intravitreal bevacizumab does not. Therefore, intravitreal steroids may be useful in DME with HEs in the fovea.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Bevacizumab/uso terapêutico , Dexametasona/administração & dosagem , Retinopatia Diabética/tratamento farmacológico , Exsudatos e Transudatos/efeitos dos fármacos , Edema Macular/tratamento farmacológico , Triancinolona Acetonida/uso terapêutico , Idoso , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/fisiopatologia , Implantes de Medicamento , Exsudatos e Transudatos/diagnóstico por imagem , Feminino , Glucocorticoides/uso terapêutico , Humanos , Injeções Intravítreas , Edema Macular/diagnóstico , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia de Coerência Óptica , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual/fisiologia
5.
Ophthalmology ; 121(4): 870-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24412281

RESUMO

PURPOSE: To measure the maximum angle of ocular versions using photographs of the 9 cardinal positions and a modified limbus test. DESIGN: An evaluation of diagnostic technology; a prospective observational study. PARTICIPANTS: We enrolled 104 healthy subjects, 20 to 40 years of age. METHODS: Photographs were obtained in the 9 cardinal positions of gaze and the images were processed using Photoshop. The images were analyzed using the Image J program to measure the angle of version. The maximum angle of the 9 cardinal positions was quantified using a modified limbus test. MAIN OUTCOME MEASURES: We measured the maximum angle of ocular versions in the 9 cardinal positions of gaze. We also compared the results for males and females. RESULTS: The mean angles of maximum version were adduction 47.4°, abduction 46.4°, elevation 31.8°, depression 47.8°, elevation in adduction 39.7°, elevation in abduction 40.7°, depression in adduction 52.7°, and depression in abduction 49.2°. The mean angle of maximum elevation was significantly smaller than that of depression (P <0.001). There were no correlations between the angle of maximum version and age, spherical equivalents, or axial length. The angle of maximum version for males was significantly greater than that for females, except for inferior gaze. CONCLUSIONS: A modified limbus test using photographs of the 9 cardinal positions is an objective and reproducible tool for quantifying ocular movement. Considering its simplicity, ease of use, and low cost, it has clear applications in clinical practice.


Assuntos
Segmento Anterior do Olho/anatomia & histologia , Movimentos Oculares/fisiologia , Fotografação/métodos , Adulto , Comprimento Axial do Olho , Medições dos Movimentos Oculares , Feminino , Fixação Ocular/fisiologia , Voluntários Saudáveis , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
6.
Arq Bras Oftalmol ; 88(2): e20230215, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39319909

RESUMO

PURPOSE: To compare the refractive prediction error of Hill-radial basis function 3.0 with those of 3 conventional formulas and 11 combination methods in eyes with short axial lengths. METHODS: The refractive prediction error was calculated using 4 formulas (Hoffer Q, SRK-T, Haigis, and Hill-RBF) and 11 combination methods (average of two or more methods). The absolute error was determined, and the proportion of eyes within 0.25-diopter (D) increments of absolute error was analyzed. Furthermore, the intraclass correlation coefficients of each method were computed to evaluate the agreement between target refractive error and postoperative spherical equivalent. RESULTS: This study included 87 eyes. Based on the refractive prediction error findings, Hoffer Q formula exhibited the highest myopic errors, followed by SRK-T, Hill-RBF, and Haigis. Among all the methods, the Haigis and Hill-RBF combination yielded a mean refractive prediction error closest to zero. The SRK-T and Hill-RBF combination showed the lowest mean absolute error, whereas the Hoffer Q, SRK-T, and Haigis combination had the lowest median absolute error. Hill-radial basis function exhibited the highest intraclass correlation coefficient, whereas SRK-T showed the lowest. Haigis and Hill-RBF, as well as the combination of both, demonstrated the lowest proportion of refractive surprises (absolute error >1.00 D). Among the individual formulas, Hill-RBF had the highest success rate (absolute error ≤0.50 D). Moreover, among all the methods, the SRK-T and Hill-RBF combination exhibited the highest success rate. CONCLUSIONS: Hill-radial basis function showed accuracy comparable to or surpassing that of conventional formulas in eyes with short axial lengths. The use and integration of various formulas in cataract surgery for eyes with short axial lengths may help reduce the incidence of refractive surprises.


Assuntos
Comprimento Axial do Olho , Extração de Catarata , Erros de Refração , Humanos , Erros de Refração/fisiopatologia , Extração de Catarata/métodos , Feminino , Inteligência Artificial , Masculino , Idoso , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Reprodutibilidade dos Testes , Biometria/métodos
7.
Sci Rep ; 14(1): 367, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172500

RESUMO

Diagnosing and monitoring glaucoma in high myopic (HM) eyes are becoming very important; however, it is challenging to diagnose this condition. This study aimed to evaluate the diagnostic ability of wide-field optical coherence tomography angiography (WF-OCTA) maps for the detection of glaucomatous damage in eyes with HM and to compare the diagnostic ability of WF-OCTA maps with that of conventional imaging approaches, including swept-source optical coherence tomography (SS-OCT) wide-field maps. In this retrospective observational study, a total 62 HM-healthy eyes and 140 HM eyes with open-angle glaucoma were included. Patients underwent a comprehensive ocular examination, including SS-OCT wide-field and 12 × 12 WF-OCTA scans. The WF-OCTA map represents the peripapillary and macular superficial vascular density maps. Glaucoma specialists determined the presence of glaucomatous damage in HM eyes by reading the WF-OCTA map and comparing its sensitivity and specificity with those of conventional SS-OCT images. The sensitivity and specificity of 12 × 12 WF-OCTA scans for HM-glaucoma diagnosis were 87.28% and 86.94%, respectively, while, the sensitivity and specificity of SS-OCT wide-field maps for HM-glaucoma diagnosis were 87.49% and 80.51%, respectively. The specificity of the WF-OCTA map was significantly higher than that of the SS-OCT wide-field map (p < 0.05). The sensitivity of the WF-OCTA map was comparable with that of the SS-OCT wide-field map (p = 0.078). The WF-OCTA map showed good diagnostic ability for discriminating HM-glaucomatous eyes from HM-healthy eyes. As a complementary method to an alternative imaging modality, WF-OCTA mapping can be a useful tool for the detection of HM glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Miopia , Disco Óptico , Humanos , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Glaucoma/diagnóstico por imagem , Miopia/diagnóstico por imagem , Angiografia , Angiofluoresceinografia/métodos , Vasos Retinianos
8.
J Ophthalmol ; 2024: 3654690, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39220230

RESUMO

Purpose: This study aimed to evaluate the expression of microRNAs (miRNAs) and inflammasomes in diabetes-induced retinal cells and to determine their role in the pathogenesis of diabetic retinopathy (DR). Methods: To establish diabetes-induced cell models, ARPE-19 cells were treated with high glucose. The expression levels of five miRNAs (miR-185, miR-17, miR-20a, miR-15a, and miR-15b) were measured in high glucose-treated ARPE-19 cells using real-time quantitative polymerase chain reaction. Western blotting was performed to measure inflammasome expression in cellular models. miR-17 was selected as the target miRNA, and inflammasome expression was measured following the transfection of an miR-17 mimic into high glucose-treated ARPE-19 cells. Results: In high glucose-treated ARPE-19 cells, miRNA expression was substantially downregulated, whereas that of inflammasome components was significantly increased. Following the transfection of the miR-17 mimic into high glucose-treated ARPE-19 cells, the levels of inflammasome components were significantly decreased. Conclusions: This study investigated the relationship between miRNAs and inflammasomes in diabetes-induced cells using high glucose-treated ARPE-19 cells. These findings suggested that miR-17 suppresses inflammasomes, thereby reducing the subsequent inflammatory response and indicating that miRNAs and inflammasomes could serve as new therapeutic targets for DR.

9.
Front Med (Lausanne) ; 11: 1288854, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38449883

RESUMO

Background: The aim of this study is to investigate the expression profiles of microRNAs (miRNAs) related to apoptosis in the aqueous humor (AH) and lens capsule (LC) of patients with glaucoma. Methods: AH and LC samples were collected from patients with open-angle glaucoma and control participants who were scheduled for cataract surgery. A miRNA PCR array comprising 84 miRNAs was used to analyze the AH (glaucoma, n = 3; control, n = 3) and LC samples (glaucoma, n = 3; control, n = 4). Additionally, the AH and LC samples (glaucoma, n = 3; control, n = 4) were subjected to quantitative real-time PCR to validate the differentially expressed miRNAs determined using the PCR array. Bioinformatics analysis was performed to identify the interactions between miRNAs and diseases. Additionally, the differential expression of these miRNAs and the target gene was validated through in vitro experiments using a retinal ganglion cell (RGC) model. Results: Expression levels of 19 and 3 miRNAs were significantly upregulated in the AH and LC samples of the glaucoma group, respectively (p < 0.05). Of these, the expression levels of hsa-miR-193a-5p and hsa-miR-222-3p showed significant differences in both AH and LC samples. Bioinformatics analysis showed experimentally validated 8 miRNA:gene pairs. Among them, PTEN was selected to analyze the expression level in AH and LC from separate cohort (glaucoma, n = 5; control, n = 4). The result showed downregulation of PTEN concurrent with upregulation of the two miRNAs in LC samples of glaucoma group. In vitro experiments validated that the expression levels of hsa-miR-193a-5p and hsa-miR-222-3p were significantly upregulated, and that of PTEN was significantly downregulated in the H2O2-treated RGC, while the level of PTEN was recovered through co-treatment with miR-193a inhibitor or miR-222 inhibitor. Conclusion: This is the first study to investigate the differential expression of apoptosis-related miRNAs in the AH and LC of patients with glaucoma. Hsa-miR-193a-5p and hsa-miR-222-3p, which were upregulated in both AH and LC, may be considered potential biomarkers for glaucoma.

10.
J Clin Med ; 12(20)2023 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-37892814

RESUMO

We examined the association between bioimpedance profiles and optical coherence tomography (OCT) features in patients with diabetic macular edema (DME). This cross-sectional study included 100 eyes of 100 patients with type 2 diabetes mellitus. The systemic fluid status was assessed using extracellular water-to-total body water ratio (ECW/TBW) and phase angle (PhA), which was measured using bioimpedance equipment. ECW/TBW was higher in the DR (diabetic retinopathy) with DME group than in the no DR and DR without DME groups (p = 0.007 and p = 0.047, respectively); however, no significant difference was observed between the no DR and DR without DME groups. The PhA values were significantly lower in the DR with DME group (5.45 ± 0.84) than in the no DR (6.69 ± 0.69) and DR without DME groups (6.05 ± 1.15) (p < 0.001, p = 0.032, respectively). The presence of multiple HRF (hyper-reflective foci) was associated with a significantly higher ECW/TBW (p = 0.001). In the group with the most significant HRF, PhA was lower than in those with none or moderate amounts of HRF (p < 0.05). Bioimpedance fluid profiles of patients with OCT features of DME suggest a connection between the overall systemic state, including fluid status and DME development. Further research is required to fully understand and utilize this information for effective clinical assessment and treatment planning.

11.
Br J Ophthalmol ; 107(1): 49-55, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34301610

RESUMO

BACKGROUND/AIMS: This study aimed to establish a wide-field optical coherence tomography (OCT) deviation map obtained from swept-source OCT (SS-OCT) scans. Moreover, it also aimed to compare the diagnostic ability of this wide-field deviation map with that of the peripapillary and macular deviation maps currently being used for the detection of early glaucoma (EG). METHODS: Four hundred eyes, including 200 healthy eyes and 200 eyes with EG were enrolled in this retrospective observational study. Patients underwent a comprehensive ocular examination, including wide-field SS-OCT (DRI-OCT Triton; Topcon, Tokyo, Japan). The individual wide-field scan was converted into a uniform template using the fovea and optic disc centres as fixed landmarks. Subsequently, the wide-field deviation map was obtained via the comparison between individual wide-field data and a normative wide-field database that had been created by combining images of healthy eyes into a uniform template in a previous study. The ability of the new wide-field deviation map to distinguish between EG and healthy eyes was assessed by comparing it with conventional deviation maps based on the area under the receiver operating characteristic curve (AUC). RESULTS: The wide-field deviation map obtained using the normative wide-field database showed the highest diagnostic ability for the diagnosis of EG (AUC=0.980 and 961 for colour-coded pixels presenting <5% and <1%, respectively) among various deviation maps. Its AUC was significantly superior to that of most conventional deviation maps (p<0.05). The wide-field deviation map demonstrated early structural glaucomatous damage well over a wider area. CONCLUSION: The wide-field SS-OCT deviation map exhibited good performance for distinguishing between eyes with EG and healthy eyes. The visualisation of the wider damaged area on the wide-field deviation map could be useful for the diagnosis of EG in clinical settings.


Assuntos
Glaucoma , Disco Óptico , Humanos , Tomografia de Coerência Óptica/métodos , Fibras Nervosas , Células Ganglionares da Retina , Glaucoma/diagnóstico , Disco Óptico/diagnóstico por imagem , Curva ROC , Pressão Intraocular
12.
J Clin Med ; 11(11)2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35683577

RESUMO

In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal control eyes and 504 glaucomatous eyes, were tested. A convolutional neural network was used for each true-colour confocal scan (Eidon AF™, CenterVue, Padova, Italy) and UWF fundus image (Optomap™, Optos PLC, Dunfermline, UK) to detect glaucoma. The diagnostic model was trained using 545 training and 232 test images. The presence of glaucoma was determined, and the accuracy and area under the receiver operating characteristic curve (AUC) metrics were assessed for diagnostic power comparison. DL-based UWF fundus imaging achieved an AUC of 0.904 (95% confidence interval (CI): 0.861−0.937) and accuracy of 83.62%. In contrast, DL-based true-colour confocal scanning achieved an AUC of 0.868 (95% CI: 0.824−0.912) and accuracy of 81.46%. Both DL-based confocal imaging modalities showed no significant differences in their ability to diagnose glaucoma (p = 0.135) and were comparable to the traditional optical coherence tomography parameter-based methods (all p > 0.005). Therefore, using a DL-based algorithm on true-colour confocal scanning and UWF fundus imaging, we confirmed that both confocal fundus imaging techniques had high value in diagnosing glaucoma.

13.
J Pers Med ; 12(9)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36143278

RESUMO

This study aimed to compare findings of optical coherence tomography (OCT) angiography (OCTA) between eyes with nearly recovered and partially recovered outer retina after full-thickness macular hole (FTMH) surgery and to identify OCTA findings associated with visual acuity. We retrospectively reviewed 30 patients who underwent surgery for idiopathic FTMH. Swept-source OCT (SS-OCT) and OCTA were performed preoperatively and at three and six months postoperatively. Subgroups were divided according to the integrity of the external limiting membranes and ellipsoid zones postoperatively. Correlations of best-corrected visual acuity six months postoperatively with SS-OCT and OCTA measurements were analyzed. There was no difference in preoperative retinal or choroidal vascular index on OCTA between the nearly and partially recovered groups. Six months postoperatively, the choriocapillaris flow-void area was significantly higher in the partially recovered group than in the fellow eye. The nearly recovered group showed better choroidal vascular flow, and vision at six months postoperatively correlated with the ratio of the operated eye's choriocapillaris flow-void area to the fellow eye. Sufficient choriocapillaris flow on OCTA is associated with better outer retinal recovery and visual outcomes after macular hole surgery.

14.
J Glaucoma ; 30(1): e8-e12, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33351550

RESUMO

PURPOSE: Microvasculature dropout (MvD) is a novel finding seen in optical coherence tomography angiography (OCTA), which is characterized by a localized dehiscence of the choriocapillaris in the parapapillary atrophy area. Disc hemorrhage (DH) is an important factor often associated with the development and especially progression of glaucoma. Here, we present 2 cases of MvD progression with DH. METHODS AND RESULTS: Case 1: A 62-year-old female patient with normal tension glaucoma in both her eyes had recurrent DH at the inferior area of her right eye. A new DH was observed in the inferotemporal area of the right eye with MvD progression on OCTA in the same direction three months from the baseline.Case 2: A 57-year-old female patient with bilateral steroid-induced secondary glaucoma also had recurrent DH in her right eye. Four months from the baseline, DH occurred in the superotemporal and inferotemporal area of the right eye, and MvD was detected on OCTA in the superotemporal corresponding direction. After 19 months from the baseline, OCTA was repeated. The DH had resolved, but the superotemporal MvD persisted. CONCLUSIONS: The 2 cases presented here are the first to report on the relationship between MvD progression and DH. MvD as visualized in OCTA imaging looks to be of clinical importance, and hopefully future studies will reveal the actual connection between MvD, DH, and glaucoma progression.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Corioide , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Pressão Intraocular , Pessoa de Meia-Idade , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais
15.
Sci Rep ; 11(1): 22034, 2021 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-34764370

RESUMO

The present study aimed to evaluate the diagnostic ability of wide-field optical coherence tomography angiography (OCTA) density map for detection of glaucomatous damage in high myopic (HM) eyes and to further compare the diagnostic ability of OCTA with that of conventional imaging approaches including red-free photography and swept-source OCT (SS-OCT) wide-field maps. A total of 77 healthy HM eyes and 72 HM eyes with open angle glaucoma (OAG) participated in this retrospective observational study. Patients underwent a comprehensive ocular examination, including wide-field SS-OCT scan and peripapillary area and macular OCTA scans. An integrated OCTA density map thereafter was merged by vascular landmark-guided superimposition of peripapillary and macular superficial vascular density maps onto the red-free photography (resulting in the OCTA-PanoMap). Glaucoma specialists then determined the presence of glaucomatous damage in HM eyes by reading the OCTA-PanoMap and compared its sensitivity and specificity with those of conventional images. Sensitivity and specificity of OCTA-PanoMap for HM-OAG diagnosis was 94.4% and 96.1%, respectively. Compared with other imaging methods, the sensitivity of OCTA-PanoMap was significantly higher than that of red-free photography (P = 0.022) and comparable to that of wide-field SS-OCT maps. Specificity of OCTA-PanoMap was significantly higher than those of other conventional imaging methods (except for wide-field thickness map). The OCTA-PanoMap showed good diagnostic ability for discrimination of HM-OAG eyes from healthy HM eyes. As a complementary method of an alternative imaging modality, OCTA-PanoMap can be a useful tool for detection of HM-OAG.


Assuntos
Glaucoma/diagnóstico por imagem , Adulto , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos
16.
J Clin Med ; 10(22)2021 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-34830717

RESUMO

This study aimed to evaluate and compare the retinal and choroidal thickness and vessel density (VD) changes between silicone oil (SO) tamponade and after SO removal using swept-source optical coherence tomography (SS-OCT) and OCT angiography (OCTA). Thirty patients who underwent pars plana vitrectomy for retinal detachment (RD) with SO tamponade were included. SS-OCT and OCTA were conducted before RD surgery, during SO tamponade, and after SO removal. A 3-dimensional volumetric wide scan protocol was used for the analysis. The segmented retina, choroidal thickness map, and peripapillary thickness were then measured. For the OCTA analysis, 4.5 × 4.5 mm scans were used. Superficial and deep capillary plexus VDs in unaffected fellow eyes and eyes after SO removal were compared. During the SO tamponade period, the thickness of the parafoveal total retina, ganglion cell-inner plexiform layer, and peripapillary retinal nerve fiber layer (ppRNFL) were significantly thinner than those of unaffected fellow eyes (p < 0.05). The parafoveal layer thickness thinning recovered up to three to six months after SO removal. Moreover, six months after SO removal, the parafoveal thickness was not significantly different compared to that of unaffected fellow eyes (p > 0.05). However, the ppRNFL thickness was significantly decreased during SO tamponade and remained unrecovered six months after SO removal. There was no significant difference in the VD on the OCTA. Thus, SO tamponade and removal for RD resulted in a change in the retinal and peripapillary thickness. This may be due to the mechanical pressure effect of SO.

17.
J Glaucoma ; 30(9): 803-812, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33979115

RESUMO

PURPOSE: (1) To evaluate the performance of deep learning (DL) classifier in detecting glaucoma, based on wide-field swept-source optical coherence tomography (SS-OCT) images. (2) To assess the performance of DL-based fusion methods in diagnosing glaucoma using a variety of wide-field SS-OCT images and compare their diagnostic abilities with that of conventional parameter-based methods. METHODS: Overall, 675 eyes, including 258 healthy eyes and 417 eyes with glaucoma were enrolled in this retrospective observational study. Each single-page wide-field report (12×9 mm) of wide-field SS-OCT imaging provides different types of images that reflect the state of the eyes. A DL-based automated diagnosis system was proposed to detect glaucoma and identify its stage based on such images. We applied the convolutional neural network to each type of image to detect glaucoma. In addition, 2 fusion strategies, fusion by convolution network (FCN) and fusion by fully connected network (FFC) were developed; they differ in terms of the level of fusion of features derived from convolutional neural networks. The diagnostic models were trained using 382 and 293 images in the training and test data sets, respectively. The diagnostic ability of this method was compared with conventional parameters of the thickness of the retinal nerve fiber layer and ganglion cell complex. RESULTS: FCN achieved an area under the receiver operating characteristic curve (AUC) of 0.987 (95% confidence interval, CI: 0.968-0.996) and an accuracy of 95.22%. In contrast, FFC achieved an AUC of 0.987 (95% CI, 0.971-0.998) and an accuracy of 95.90%. Both FCN and FFC outperformed the conventional method (P<0.001). In detecting early glaucoma, both FCN and FFC achieved significantly higher AUC and accuracy than the conventional approach (P<0.001). In addition, the classification performance of the DL-based fusion methods in identifying the 5 stages of glaucoma is presented via a confusion matrix. CONCLUSION: DL protocol based on wide-field OCT images outperformed the conventional method in terms of both AUC and accuracy. Therefore, DL-based diagnostic methods using wide-field OCT images are promising in diagnosing glaucoma in clinical practice.


Assuntos
Aprendizado Profundo , Glaucoma , Estudos Transversais , Glaucoma/diagnóstico por imagem , Humanos , Pressão Intraocular , Fibras Nervosas , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica
18.
J Glaucoma ; 30(1): 10-16, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33351548

RESUMO

PRCIS: Recognizing the shortcomings of poor consistency of the fovea-disc relationship at different time points and comparing PanoMaps may well facilitate the understanding of the spatial relationship between parapapillary and macular areas in glaucoma. PURPOSE: The aims of this study are to analyze the spatial distribution of the frequently damaged areas in early glaucoma, compare the patterns between nonprogressors and progressors using the combined wide-field parapapillary and macular deviation maps (PanoMap), and to evaluate the consistency of the fovea-disc relationship in PanoMap. The fovea-disc distance (FDD) and fovea-disc axis (FDA) were compared at baseline and at the last follow-up. MATERIALS AND METHODS: In total, 118 patients with early glaucoma and a minimum follow-up period of 3 years were included in this retrospective observational study. The pattern of structural changes was evaluated by averaging the PanoMaps of the enrolled patients at baseline and last follow-up. Longitudinal comparison of the FDD and FDA was performed at baseline and the last follow-up. Patients were divided into nonprogressor (n=44) and progressor (n=74), and the patterns of glaucoma progression in PanoMaps were compared between them. RESULTS: At baseline, the glaucomatous damage was found more frequently in the macular compared with the parapapillary area. The spatial distribution of frequently damaged areas was similar between the nonprogressor and progressor. At the last follow-up, compared with the baseline structural change on the PanoMap, the progressive structural changes extended toward the fovea at both the parapapillary and macular areas in the progressor. The FDD and FDA were significantly different between the baseline and the last follow-up. CONCLUSIONS: The PanoMaps showed a clear spatial distribution of early glaucomatous changes, indicating that the damaged area was frequently observed in the macular area. As the consistency of the fovea-disc relationship in PanoMaps was not excellent, this aspect should be considered when interpreting the PanoMap.


Assuntos
Glaucoma , Pressão Intraocular , Progressão da Doença , Fóvea Central , Humanos , Estudos Retrospectivos
19.
Transl Vis Sci Technol ; 10(2): 7, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-34003891

RESUMO

Purpose: One purpose of this study was to collect wide-field swept-source optical coherence tomography (SS-OCT) data from healthy eyes and build a wide-filed normative database. Another purpose was to compare the glaucoma diagnostic ability of new parameters based on this normative database to the parameters that are currently in use, such as the peripapillary retinal nerve fiber layer (RNFL), macular ganglion cell-inner plexiform layer, and ganglion cell complex (GCC) thickness. Methods: This study had 220 healthy eyes and 292 eyes with early-stage glaucoma (EG) and moderate-stage glaucoma (MG) enrolled. Using the wide-field SS-OCT images (12 × 9 mm) of healthy eyes, a wide-field normative database was constructed by transforming and combining the individual images into a uniform template using the fovea and optic disc centers as fixed landmarks. Adjustment for the disc size was conducted. With this normative database, new parameters based on the ratio of the fovea-disc distance (FDD) consisting of the fovea-disc relationship were evaluated. The glaucoma diagnostic ability was assessed based on the area under the receiver operating characteristic curve (AUC). Results: Among the new peripapillary parameters, the RNFL of the circumference of the circle with diameter 0.8 FDD showed the highest AUC value for EG and MG, but the value was not significantly superior to that of the initial RNFL (AUC = 0.940 vs. 0.937, P = 0.631). Among the macular parameters, the GCC of the area of the circle of 1.5 FDD showed the highest AUC value for EG and MG, and the value was significantly superior to that of initial GCC (AUC = 0.929 vs. 0.919, P = 0.033). However, there was no significant difference between the initial and adjusted GCC thickness in patients included in the EG or MG groups separately. Conclusions: A wide-field normative database was built to consider the relationship between the fovea and the optic disc. Considering this aspect, we found that the GCC analysis using a broader area presented a significantly greater glaucoma diagnostic performance for EG and MG in the macula than the initial parameter for the GCC. Translational Relevance: Based on this wide-field normative database, the clinical use of a wide-field deviation map may help diagnose the patients with EG and MG in the future.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Estudos Transversais , Glaucoma/diagnóstico , Humanos , Fibras Nervosas , Células Ganglionares da Retina
20.
J Glaucoma ; 30(6): 459-464, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33337722

RESUMO

PURPOSE: The aim was to investigate the effects of hemodialysis (HD) on peripapillary choroidal thickness (PCT) by swept-source optical coherence tomography and on other ophthalmologic parameters in patients with end-stage kidney disease. MATERIALS AND METHODS: This was a prospective observational study. The authors evaluated 29 patients who underwent HD for end-stage kidney disease. Detailed ophthalmologic examinations and swept-source optical coherence tomography were performed immediately before and after HD. PCT was measured using the modification tool in the built-in OCT image viewer program. Changes in PCT before and after HD were statistically analyzed. RESULTS: The average PCT significantly decreased from 127.3±49.2 µm before HD to 117.1±50.9 µm after HD (P<0.001). A significant correlation was found between changes in PCT and macular choroidal thickness (ρ=0.547, P=0.002). Changes in mean ocular perfusion pressure did not significantly correlate with changes in PCT (ρ=-0.049, P=0.803). CONCLUSIONS: PCT significantly decreased after HD. HD could influence the optic nerve head and its surrounding structures.


Assuntos
Disco Óptico , Tomografia de Coerência Óptica , Corioide/diagnóstico por imagem , Humanos , Pressão Intraocular , Diálise Renal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA