Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
BMC Cardiovasc Disord ; 22(1): 349, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35918658

RESUMO

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) represents an alternative stroke prevention method in patients with atrial fibrillation and an increased bleeding risk, chronic kidney disease or contraindications to oral anticoagulants. Aim of our study was to evaluate the feasibility and safety of percutaneous LAAO in high-risk, frail patients having undergone transcatheter aortic valve implantation (TAVI). METHODS: Thirty-one patients having undergone TAVI and scheduled for LAAO were prospectively included in our study. RESULTS: Implantation was successful in 29 of 31 cases (93.5%).There were no patients that developed a major acute cardiovascular event, stroke, or device dislocation/embolization. There was a single case of major bleeding (3.2%) and 3 cases of acute kidney injury (9.7%). At 3 months, no patients experienced a stroke, one patient had a device-related thrombus (3.4%), one patient showed a significant peri-device leak, and one patient had a persistent iatrogenic atrial septal defect. CONCLUSIONS: Our study shows that percutaneous LAAO may represent a feasible alternative strategy for stroke prevention, that can be safely performed in high-risk, multimorbid patients with high bleeding risk or contraindications to oral anticoagulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Idoso Fragilizado , Humanos , Octogenários , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(1): E146-E153, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32433818

RESUMO

BACKGROUND: Cerebral O2 saturation (ScO2 ) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). OBJECTIVES: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. METHODS AND RESULTS: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. CONCLUSIONS: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Projetos Piloto , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Medicina (Kaunas) ; 57(12)2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34946277

RESUMO

Background and Objectives: We tested if a novel combination of predictors could improve the accuracy of outcome prediction after transfemoral transcatheter aortic valve implantation (TAVI). Materials and Methods: This prospective study recruited 169 participants (49% female; median age 81 years). The primary endpoint was midterm mortality; secondary endpoints were acute Valve Academic Research Consortium (VARC)-3 complication rate and post-TAVI in-hospital length of stay (LoS). EuroSCORE II (ESII), comorbidities (e.g., coronary artery disease), eGFR (estimated glomerular filtration rate; based on cystatin C), hemoglobin, creatinine, N-Terminal pro-Brain Natriuretic Peptide (NTproBNP) levels and patient-reported outcome measures (PROMs, namely EuroQol-5-Dimension-5-Levels, EQ5D5L; Kansas City Cardiomyopathy Questionnaire, KCCQ; clinical frailty scale, CFS) at baseline were tested as predictors. Regression (uni- and multi-variate Cox; linear; binary logistic) and receiver operating characteristic (ROC)-curve analysis were applied. Results: Within a median follow-up of 439 (318-585) days, 12 participants died (7.1%). Independent predictors of mortality using multivariate Cox regression were baseline eGFR (p = 0.001) and KCCQ (p = 0.037). Based on these predictors, a Linear Prediction Score (LPS1) was calculated. The LPS1-area under the curve (AUC)-value (0.761) was significantly higher than the ESII-AUC value (0.597; p = 0.035). Independent predictors for LoS > 6 days (the median LoS) were eGFR (p = 0.028), NTproBNP (p = 0.034), and EQ5D5L values (p = 0.002); a respective calculated LPS2 provided an AUC value of 0.677 (p < 0.001). Eighty participants (47.3%) experienced complications. Male sex predicted complications only in the univariate analysis. Conclusions: The combination of KCCQ and eGFR can better predict midterm mortality than ES II alone. Combining eGFR, NTproBNP, and EQ5D5L can reliably predict LoS after TAVI. This novel method improves personalized TAVI risk stratification and hence may help reduce post-TAVI risk.


Assuntos
Estenose da Valva Aórtica , Tempo de Internação , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 95(1): 54-64, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31033152

RESUMO

INTRODUCTION: The treatment of aortic stenosis has been revolutionized by transcatheter aortic valve replacement (TAVR), but the experience in patients with liver disease is limited. To address this open question, we report the outcome of patients with liver disease undergoing surgical aortic valve replacement (SAVR), transapical (TA), and transfemoral (TF) TAVR. METHODS AND RESULTS: Between January 2004 and August 2016, 4,394 patients received aortic valve replacement at our institution. We identified 85 patients (mean follow-up 504 ± 733 days, age 73.4 ± 9.2 years, 44.7% female) with preexisting liver disease (median model of end-stage liver disease score 11, MELD-Na), who underwent TF-TAVR (n = 30), TA-TAVR (n = 13), or SAVR (n = 42). Baseline Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) and of Mortality and Morbidity (STS-PROMM) were the lowest in SAVR patients (related to TF- and TA-TAVR, both p < 0.01). Operative mortality (18.8%) was high, but no procedure showed superior short-term outcome. Need for renal replacement therapy (31.5% vs. 10.3%, p = 0.046) and reoperation occurred more frequently after SAVR than after TF-TAVR (26.6% vs. 6.7%, p = 0.021). Moreover, TF-TAVR patients had superior long-term survival compared to SAVR (log-rank test p = 0.048 and Cox regression adjusted for MELD and STS-PROM, p = 0.01, HR 0.25, CI95 0.09-0.71). Baseline MELD-Na (p = 0.013) and STS PROMM (p = 0.01) were predictors for operative mortality (ROC-analysis). CONCLUSIONS: Our results indicate increased perioperative risks for patients with liver disease undergoing AVR, but favorable long-term survival after TF-TAVR compared to SAVR. For baseline risk, stratification in patients with liver disease undergoing AVR, MELD-Na and STS-PROMM are valuable predictors.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Implante de Prótese de Valva Cardíaca , Hepatopatias/complicações , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Hepatopatias/diagnóstico , Hepatopatias/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
J Interv Cardiol ; 2019: 4292987, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772530

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is currently recommended for patients with severe aortic stenosis at intermediate or high surgical risk. The decision process during TAVI evaluation includes a thorough benefit-risk assessment, and knowledge about long-term benefits and outcomes may improve patients' expectation management. OBJECTIVE: To evaluate patients' perceived health status and self-reported long-term outcome more than 5 years after TAVI. METHODS AND RESULTS: Demographic and procedure data were obtained from all patients treated with TAVI at our institution from 2006 to 2012. A cross-sectional survey was conducted on the patients alive, measuring health status, including the EQ-5D-5L questionnaire, and clinical outcomes. 103 patients (22.8%) were alive at a median follow-up period of 7 years (5.4-9.8). 99 (96%) of the 103 patients were included in the final analysis. The mean age at follow-up was 86.5 years ± 8.0 years, and 56.6% were female. Almost all patients (93.9%) described an improvement of their quality of life after receiving TAVI. At late follow-up, the mean utility index and EQ-VAS score were 0.80 ± 0.20 and 58.49 ± 11.49, respectively. Mobility was found to be the most frequently reported limitation (85.4%), while anxiety/depression was the least frequently reported limitation (19.8%). With respect to functional class, 64.7% were in New York Heart Association (NYHA) class III or IV, compared to 67.0% prior to TAVI (p=0.51). Self-reported long-term outcomes revealed mainly low long-term complication rates. 74 total hospitalizations were reported after TAVI, and among those 43% for cardiovascular reasons. Within cardiovascular rehospitalizations, new pacemaker implantations were the most frequently reported (18.9%), followed by cardiac decompensation and coronary heart disease (15.6%). CONCLUSION: The majority of the patients described an improvement of health status after TAVI. More than five years after TAVI, the patients' perceived health status was satisfactory, and the incidence of clinical events and hospitalizations was very low.


Assuntos
Nível de Saúde , Qualidade de Vida , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estudos Transversais , Feminino , Seguimentos , Alemanha/epidemiologia , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Limitação da Mobilidade
6.
J Heart Valve Dis ; 24(2): 228-35, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26204691

RESUMO

BACKGROUND AND AIM OF THE STUDY: Systemic lupus erythematosus (SLE) and primary/secondary antiphospholipid syndrome (APLS) may cause early degenerative changes in cardiac valves, such as Libman-Sacks endocarditis, though few reports exist of this condition. Herein are presented the early and late clinical outcomes after cardiac valve surgery in patients diagnosed with SLE and APLS in a single-center experience. METHODS: A prospective analysis was conducted of the perioperative and follow up data acquired from patients with diagnosed SLE, and primary and secondary APLS, who underwent either single or combined valve surgery at the authors' department between 2002 and 2014. RESULTS: Fifteen patients (14 females, one male; mean age 53 ± 16 years; range: 16-77 years) were identified. The mean follow up time was 49 ± 32 months (range: 12.5-119 months). Thirteen patients (11 females, two males) were diagnosed with SLE; one of these patients had tricuspid Libman-Sacks endocarditis, while two female patients had primary APLS and four had secondary APLS. Besides bioprosthetic and mechanical valve replacements, mitral and tricuspid valve reconstruction were performed. The mean cross-clamp time was 112 ± 73 min (range: 55-294 min). Early major cardiovascular events occurred in two patients, and late non-fatal events in four patients, including one thromboembolic event. The 30-day and in-hospital mortalities were both 0%. Currently, 12 patients (80%) are alive at the end of follow up. Actuarial survival was 92 ± 7.4% at one year, 74 ± 18% at four years, and 49 ± 23% at ten years. CONCLUSION: Despite general concerns, the present results confirmed that patients with SLE and APLS can be operated on for cardiac valve disease, with favorable early results and acceptable long-term outcome.


Assuntos
Síndrome Antifosfolipídica/complicações , Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/cirurgia , Lúpus Eritematoso Sistêmico/complicações , Adolescente , Adulto , Idoso , Feminino , Doenças das Valvas Cardíacas/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Oligopeptídeos , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Adulto Jovem
7.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506737

RESUMO

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Catéteres , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valvas Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
J Vasc Surg ; 57(6): 1628-36, 1636.e1-3, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23294503

RESUMO

OBJECTIVE: Fibrillin-1 hypomorphic mice (mgR/mgR) are accepted as a model of Marfan syndrome. Phenotypic investigations of this mouse have not previously included quantification of phenotypic features and detailed examinations of the histopathology other than in the ascending aorta. METHODS: We developed a quantitative polymerase chain reaction assay to genotype the mice. Necropsy was performed on 50 male mice after natural death. We then sacrificed 10 mgR/mgR and 10 wild-type mice at 14-19 weeks to perform in vivo computed tomographic scans (n = 3) and microscopic examinations (n = 7). Four aortic segments (ascending, descending, pararenal, and infrarenal aorta) were excised. Each segment was divided into four subsegments and analyzed with Van Gieson staining. The number of elastin breaks and internal aortic diameter were determined twice in randomized, blinded fashion. RESULTS: Computed tomographic scans of mgR/mgR mice revealed aneurysm formation in the ascending aorta and kyphoscoliosis. Elastolysis was present in all four aortic segments of mgR/mgR but was rarely observed in wild-type mice (P < .001). The diameter of the ascending aorta was larger in mgR/mgR than in wild-type mice (P = .01), but para- and infrarenal aortic diameter were even smaller in mgR/mgR mice (P < .001 and P = .01, respectively). Exploratory gene expression analysis showed a number of differentially expressed genes with overrepresentation of immune-related functions. Quantitative polymerase chain reaction analysis confirmed upregulation of selected genes in both the ascending aorta and the abdominal aorta. CONCLUSIONS: Our findings suggest that mgR/mgR mice could be a useful model to study aortic abnormalities in segments other than the ascending aorta in order to understand the molecular mechanisms of aortic disease in Marfan syndrome.


Assuntos
Aorta/anormalidades , Aorta/metabolismo , Modelos Animais de Doenças , Síndrome de Marfan , Proteínas dos Microfilamentos/biossíntese , Animais , Aorta/patologia , Fibrilina-1 , Fibrilinas , Masculino , Camundongos , Proteínas dos Microfilamentos/genética
9.
Thorac Cardiovasc Surg ; 61(7): 610-1, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23817771

RESUMO

Transseptal puncture for left heart catheter or left atrial appendage occlusion is a highly standardized routine intervention in interventional cardiology. However, mispuncture is rare but can be life threatening at worst. Here, we report the case of a combined mispuncture of the right atrium and the ascending aorta resulting in a pericardial effusion with a hemodynamic effective tamponade requiring urgent cardiac operation for successful life saving.


Assuntos
Aorta/cirurgia , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos , Átrios do Coração/cirurgia , Traumatismos Cardíacos/cirurgia , Lesões do Sistema Vascular/cirurgia , Idoso , Aorta/lesões , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Emergências , Feminino , Átrios do Coração/lesões , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/etiologia , Humanos , Derrame Pericárdico/etiologia , Derrame Pericárdico/cirurgia , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/etiologia
10.
Cardiovasc Interv Ther ; 37(1): 191-201, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33313960

RESUMO

Replacement of a stenotic aortic valve reduces immediately the ventricular to aortic gradient and is expected to improve diastolic and systolic left ventricular function over the long term. However, the hemodynamic changes immediately after valve implantation are so far poorly understood. Within this pilot study, we performed an invasive pressure volume loop analysis to describe the early hemodynamic changes after transcatheter aortic valve implantation (TAVI) with self-expandable prostheses. Invasive left ventricular pressure volume loop analysis was performed in 8 patients with aortic stenosis (mean 81.3 years) prior and immediately after transfemoral TAVI with a self-expandable valve system (St. Jude Medical Portico Valve). Parameters for global hemodynamics, afterload, contractility and the interaction of the cardiovascular system were analyzed. Left ventricular ejection fraction, (53.9% vs. 44.8%, p = 0.018), preload recruitable stroke work (68.5 vs. 44.8 mmHg, p = 0.012) and end-systolic elastance (3.55 vs. 2.17, p = 0.036) both marker for myocardial contractility declined significantly compared to baseline. As sign of impaired diastolic function, TAU, a preload-independent measure of isovolumic relaxation (37.3 vs. 41.8 ms, p = 0.018) and end-diastolic pressure (13.1 vs. 16.4 mmHg, p = 0.015) raised after valve implantation. Contrarily, a smaller ratio of end-systolic to arterial elastance (ventricular-arterial coupling) indicates an improvement of global cardiovascular energy efficiency (1.40 vs. 0.97 p = 0.036). Arterial elastance had a strong correlation with the number of conducted rapid ventricular pacings (Pearson correlation coefficient, r = 0.772, p = 0.025). Invasive left ventricular pressure volume loop analysis revealed impaired systolic and diastolic function in the early phase after TAVI with self-expandable valve for the treatment of severe aortic stenosis. Contrarily, we found indications for early improvement of global cardiovascular energy efficiency.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Projetos Piloto , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
11.
Clin Res Cardiol ; 111(8): 955-965, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35505123

RESUMO

BACKGROUND: Cerebral oxygen saturation (ScO2) can be measured non-invasively by near-infrared spectroscopy (NIRS) and correlates with cerebral perfusion. We investigated cerebral saturation during transfemoral transcatheter aortic valve implantation (TAVI) and its impact on outcome. METHODS AND RESULTS: Cerebral oxygenation was measured continuously by NIRS in 173 analgo-sedated patients during transfemoral TAVI (female 47%, mean age 81 years) with self-expanding (39%) and balloon-expanding valves (61%). We investigated the periprocedural dynamics of cerebral oxygenation. Mean ScO2 at baseline without oxygen supply was 60%. During rapid ventricular pacing, ScO2 dropped significantly (before 64% vs. after 55%, p < 0.001). ScO2 at baseline correlated positively with baseline left-ventricular ejection fraction (0.230, p < 0.006) and hemoglobin (0.327, p < 0.001), and inversely with EuroSCORE-II ( - 0.285, p < 0.001) and length of in-hospital stay ( - 0.229, p < 0.01). Patients with ScO2 < 56% despite oxygen supply at baseline had impaired 1 year survival (log-rank test p < 0.01) and prolonged in-hospital stay (p = 0.03). Furthermore, baseline ScO2 was found to be a predictor for 1 year survival independent of age and sex (multivariable adjusted Cox regression, p = 0.020, hazard ratio (HR 0.94, 95% CI 0.90-0.99) and independent of overall perioperative risk estimated by EuroSCORE-II and hemoglobin (p = 0.03, HR 0.95, 95% CI 0.91-0.99). CONCLUSIONS: Low baseline ScO2 not responding to oxygen supply might act as a surrogate for impaired cardiopulmonary function and is associated with worse 1 year survival and prolonged in-hospital stay after transfemoral TAVI. ScO2 monitoring is an easy to implement diagnostic tool to screen patients at risk with a potential preserved recovery and worse outcome after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Oxigênio , Saturação de Oxigênio , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular Esquerda
12.
J Pers Med ; 12(3)2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35330346

RESUMO

Background: The aim of this study was to identify pre-operative parameters able to predict length of stay (LoS) based on clinical data and patient-reported outcome measures (PROMs) from a scorecard database in patients with significant aortic stenosis who underwent TAVI (transfemoral aortic valve implantation). Methods: 302 participants (51.7% males, age range 78.2−84.2 years.) were prospectively recruited. After computing the median LoS value (=6 days, range = 5−8 days), we implemented a decision tree algorithm by setting dichotomized values at median LoS as the dependent variable and assessed baseline clinical variables and PROMs (Clinical Frailty Scale (CFS), EuroQol-5 Dimension-5 Levels (EQ-5D) and Kansas City Cardiomyopathy Questionnaire (KCCQ)) as potential predictors. Results: Among clinical parameters, only peripheral arterial disease (p = 0.029, HR = 1.826) and glomerular filtration rate (GFR, cut-off < 33 mL/min/1.73 m2, p = 0.003, HR = 2.252) were predictive of LoS. Additionally, two PROMs (CFS; cut-off = 3, p < 0.001, HR = 1.324 and KCCQ; cut-off = 30, p = 0.003, HR = 2.274) were strong predictors. Further, a risk score for LoS (RS_LoS) was calculated based on these predictors. Patients with RS_LoS = 0 had a median LoS of 5 days; patients RS_LoS ≥ 3 had a median LoS of 8 days. Conclusions: based on the pre-operative values of the above four predictors, a personalized prediction of LoS after TAVI can be achieved.

13.
J Geriatr Cardiol ; 19(9): 675-684, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36284683

RESUMO

Background: Percutaneous left atrial appendage occlusion (LAAO) requires puncture of the interatrial septum. The immediate hemodynamic effects of iatrogenic atrial septal defects (iASD) after LAAO have not been examined so far. We aimed at evaluating these effects through invasive measurements of pressure and oxygen saturation. Moreover, we assessed the incidence of persistent iASD at three months. METHODS: Forty-eight patients scheduled for percutaneous LAAO were prospectively included in the study. Pressure and oxygen saturation were measured (1) in the right atrium (RA) before transseptal puncture, (2) in the left atrium (LA) through the transseptal sheath after transseptal puncture, (3) in the LA after removal of introducer sheath, and (4) in the RA after removal of introducer sheath. Transesophageal echocardiography was performed at three months to detect iASD. RESULTS: Pressure in the RA increased significantly after removing the introducer sheath (P = 0.034), whereas no difference was found in oxygen saturation in the RA (P = 0.623). Pressure measurement in the LA showed no significant difference after removing the introducer sheath (P = 0.718). Oxygen saturation in the LA also showed no significant difference (P = 0.129). Follow-up transesophageal echocardiogram at 3 months revealed a persistent iASD in 4 patients (8.5 %). CONCLUSIONS: Our study suggests that iASD after percutaneous LAAO does not result in significant shunts directly after the procedure, although a significant increase of mean right atrial pressure can be observed. Persistent iASDs after percutaneous LAAO seem to be relatively rare at three months.

14.
Clin Res Cardiol ; 110(5): 640-648, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33249517

RESUMO

AIMS: Stroke is a major complication after transcatheter aortic valve implantation (TAVI). Although multifactorial, it remains unknown whether the valve deployment system itself has an impact on the incidence of early stroke. We performed a meta- and network analysis to investigate the 30-day stroke incidence of self-expandable (SEV) and balloon-expandable (BEV) valves after transfemoral TAVI. METHODS AND RESULTS: Overall, 2723 articles were searched directly comparing the performance of SEV and BEV after transfemoral TAVI, from which 9 were included (3086 patients). Random effects models were used for meta- and network meta-analysis based on a frequentist framework. Thirty-day incidence of stroke was 1.8% in SEV and 3.1% in BEV (risk ratio of 0.62, 95% confidence interval (CI) 0.49-0.80, p = 0.004). Treatment ranking based on network analysis (P-score) revealed CoreValve with the best performance for 30-day stroke incidence (75.2%), whereas SAPIEN had the worst (19.0%). However, network analysis showed no inferiority of SAPIEN compared with CoreValve (odds ratio 2.24, 95% CI 0.70-7.2). CONCLUSION: Our analysis indicates higher 30-day stroke incidence after transfemoral TAVI with BEV compared to SEV. We could not find evidence for superiority of a specific valve system. More randomized controlled trials with head-to-head comparison of SEV and BEV are needed to address this open question.


Assuntos
Complicações Pós-Operatórias/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Humanos , Incidência , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
15.
Acta Cardiol ; 76(6): 615-622, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32396499

RESUMO

BACKGROUND: Nutritional status predicts outcomes after TAVR. Predictive value of Prognostic Nutritional Index (PNI) was investigated in patients undergoing TAVR, and compared to other nutritional indexes. METHODS: A cohort of 114 patients undergoing TAVR in a high-volume centre was studied. A prospective 1-year follow-up was completed. PNI was estimated as follows: (10 × serum albumin[g/dl])+(0.005 × total lymphocytes [1000/µl]). One-year survival was compared in patients with PNI above vs below median; Kaplan-Meier curves were created. A multivariate analysis was used to assess predictive value of PNI for 1-year mortality. ROC curves were used to assess discrimination by PNI, and to compare it with Geriatric Nutritional Risk Index (GNRI) and Body Mass Index (BMI). RESULTS: Mean age was 82.2 years, 59.6% were male. Mean PNI was 46 ± 5. Pre-procedurally, no differences were found between patients with high vs. low PNI. One-year mortality was significantly higher in patients with low PNI values (19/57 vs. 4/57; p < .001). Complications did not differ. A higher PNI predicted 1-year survival, even after adjusting for clinical factors (model 1: HR 0.8, 95% CI 0.7-0.9, p < .0001) and laboratory parameters (NT-proBNP, IL-6, CRP, eGFR, cystatin C, haemoglobin) (model 2: HR 0.8, 95% CI 0.7-0.9, p < .05). ROC curves revealed a stronger predictive value for PNI (AUC 0.80) compared to GNRI (0.77) and BMI (0.6). The optimal cut-off for PNI was 45. CONCLUSION: PNI is a useful and practical nutritional marker reflecting malnutrition and inflammation prior to the intervention, and strongly predicts 1-year survival. PNI seems to be a better prognostic marker than BMI or GNRI after TAVR.


Assuntos
Avaliação Nutricional , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Catéteres , Feminino , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
16.
Front Cardiovasc Med ; 7: 605257, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33330669

RESUMO

Background: Both EPO levels and anemia have shown prognostic value in several cardiac disorders. An observational study with a prospective follow-up was performed to investigate their independent prognostic roles in severe aortic stenosis. Methods: An up to 36-month follow-up of consecutive patients with severe aortic stenosis undergoing TAVR in a high-volume center was performed. Patients with eGRF <30 mL/min/1.73 m2 were excluded. EPO levels and/or anemia status and its association with mid-term mortality were assessed. Results: Out of 407, 360 met eligibility criteria. Median age was 83 years, with 71.4% having a NYHA class III/IV. Anemia was present in 51.9%, and iron deficiency in 52.8%. Median (IQR) EPO levels were 14.4 (9.30-24.30) mIU/mL. Median follow-up was 566 days. Anemia was associated with overall mortality (HR 2.40, 95% CI 1.51-3.80, p < 0.001). Higher logEPO levels were associated with mid-term mortality (HR 4.05, 95% CI 2.29-7.16, p < 0.001), even after adjusting for clinically and/or statistically relevant factors (multivariate HR 2.25, 95 CI 1.09-4.66, p = 0.029). Kaplan-Meier analyses showed early diverging curves for anemia vs. non-anemia, whereas curves for patients in various EPO level quartiles started to diverge at about 100 days, with differences consistently increasing during the subsequent entire follow-up period. Conclusions: Differently from anemia, which was a strong predictor for both early and late mortality in severe aortic stenosis after TAVR, independent prognostic value of EPO only emerged after post-TAVR recovery. EPO prognostic value was independent from anemia and mild-to-moderate renal dysfunction. High EPO levels could be useful to identify patients with severe aortic stenosis showing a compromised mid-term survival in spite of TAVR use and independently from early TAVR results.

17.
J Invasive Cardiol ; 32(3): 82-87, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32123140

RESUMO

OBJECTIVE: The aim of this study was to evaluate hemodynamic outcome, structural valve deterioration, and bioprosthetic valve failure beyond 5 years after transcatheter aortic valve replacement (TAVR). METHODS: Demographic, procedural, and outcome data were obtained from all patients treated with TAVR at our institution from 2006 to 2012. We included all patients with echocardiographic data at baseline and with a follow-up echocardiography more than 5 years after TAVR. Standardized definitions were used to assess durability of transcatheter aortic valves. RESULTS: A total of 452 patients were treated with apical or transfemoral transcatheter aortic valve implantation (TAVI) from 2006-2012, and 103 (23%) patients were still alive more than 5 years post TAVI. Mean duration of follow-up was 7.0 ± 0.9 years, with a maximum duration of 9.8 years. Seventy-nine of the 103 patients (76.7%) underwent follow-up echocardiography. Mean aortic gradient decreased from 51.8 ± 14.3 mm Hg before TAVR to 11.7 ± 5.8 mm Hg after TAVR (P<.001), and remained stable at 10.6 ± 6.3 mm Hg during late follow-up (P=.26). Bioprosthetic valve failure occurred in 3 patients (3.8%); two of these patients required reintervention. Seven patients (8.9%) had moderate structural valve deterioration, and 1 patient (1.3%) had severe structural valve deterioration. CONCLUSION: TAVR with self-expanding and balloon-expandable valves appears to be a long-lasting treatment strategy for severe aortic stenosis with excellent long-term hemodynamic function and very low incidence of structural valve deterioration and bioprosthetic valve failure.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Seguimentos , Hemodinâmica , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
ESC Heart Fail ; 7(3): 973-983, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31991063

RESUMO

AIMS: Treating patients with acute decompensated heart failure (ADHF) presenting with volume overload is a common task. However, optimal guidance of decongesting therapy and treatment targets are not well defined. The inferior vena cava (IVC) diameter and its collapsibility can be used to estimate right atrial pressure, which is a measure of right-sided haemodynamic congestion. The CAVA-ADHF-DZHK10 trial is designed to test the hypothesis that ultrasound assessment of the IVC in addition to clinical assessment improves decongestion as compared with clinical assessment alone. METHODS AND RESULTS: CAVA-ADHF-DZHK10 is a randomized, controlled, patient-blinded, multicentre, parallel-group trial randomly assigning 388 patients with ADHF to either decongesting therapy guided by ultrasound assessment of the IVC in addition to clinical assessment or clinical assessment alone. IVC ultrasound will be performed daily between baseline and hospital discharge in all patients. However, ultrasound results will only be reported to treating physicians in the intervention group. Treatment target is relief of congestion-related signs and symptoms in both groups with the additional goal to reduce the IVC diameter ≤21 mm and increase IVC collapsibility >50% in the intervention group. The primary endpoint is change in N-terminal pro-brain natriuretic peptide from baseline to hospital discharge. Secondary endpoints evaluate feasibility, efficacy of decongestion on other scales, and the impact of the intervention on clinical endpoints. CONCLUSIONS: CAVA-ADHF-DZHK10 will investigate whether IVC ultrasound supplementing clinical assessment improves decongestion in patients admitted for ADHF.


Assuntos
Insuficiência Cardíaca , Veia Cava Inferior , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Hospitalização , Humanos , Ultrassonografia , Veia Cava Inferior/diagnóstico por imagem
19.
J Cardiothorac Surg ; 14(1): 187, 2019 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-31694667

RESUMO

BACKGROUND: This single center study compares the different surgical techniques used in the treatment of acute aortic dissection type A (AADA) analyzing the influence of the extent of the surgical approach on outcome. METHODS: From 1988 to 2012, 407 patients were operated for AADA. The cohort was divided into subgroups according to the surgical approach. These groups were compared with the supracommissural replacement group (SCR; n = 141). Groups included aortic valve sparing techniques (AVS; n = 29), Composite replacement (COMP; n = 119), COMP with total arch replacement (COMP+TAR; n = 27) and SCR with TAR (n = 75). RESULTS: Compared to SCR alone, operation (p = 0.005), bypass-, cross-clamp and circulatory arrest times were longer in SCR + TAR (all p < 0.001). Moreover, operation, bypass and cross clamp times were longer in COMP+TAR (p = 0.003, p = 0.002 and p < 0.001 respectively). COMP alone and AVS required longer cross-clamp time, too (p < 0,001 and p = 0.002, respectively). Overall 30-day mortality was 21% with the observed lowest rate after AVS (14%, SCR 18%, COMP 25%) but differences in 30-day mortality were not statistically significant. The estimated 10-year survival was 42%, especially AVS demonstrated a good 10-year survival (69%). David technique was superior to Yacoub technique concerning incidence of redo interventions (p = 0.036). Risk factors for early mortality included age, circulatory arrest, general malperfusion, bypass and operation time. Circulatory arrest per se was revealed as risk factor for long-term survival. CONCLUSIONS: Within our single center retrospective study concomitant aortic root repair or aortic arch replacement for AADA demonstrated acceptable early and long-term survival. Circulatory arrest, long bypass and operation times per se might be important risk factors for early mortality. AVS techniques can be performed safely and have good outcomes in acute aortic dissection repair.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Dissecção Aórtica/mortalidade , Aorta/cirurgia , Aneurisma Aórtico/mortalidade , Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
20.
J Invasive Cardiol ; 31(7): E199-E204, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31257214

RESUMO

OBJECTIVES: Pairwise comparisons of clinical and hemodynamic outcomes with new transcatheter aortic valve replacement (TAVR) prostheses are needed to help interventionists select the most appropriate device. The self-expandable Portico valve (Abbott Vascular) was compared with the balloon-expandable Sapien 3 valve (Edwards Lifesciences) at a high-volume center in a real-world setting. METHODS: All patients undergoing TAVR with a new-generation device from March 2015 to September 2017 at a single center were included. Baseline, peri-interventional, and prospective 30-day follow-up data were obtained. A nearest-neighbor propensity-score matching procedure (2:1) was used, based on age, STS score, EuroScore II, New York Heart Association (NYHA) status, and sex. Primary endpoint was 30-day all-cause mortality. Secondary endpoints included procedural results, complications according to Valve Academic Research Consortium (VARC)-2 criteria, and echocardiographic findings. RESULTS: A total of 177 out of 273 patients were matched (104 Portico valves and 73 Sapien 3 valves). Procedural success rates were 99.0% vs 98.6%, respectively; P=NS). Contrast dye use (160 mL for Portico vs 120 mL for Sapien 3; P<.001) and fluoroscopy time (19.0 min for Portico vs 15.5 min for Sapien 3; P=.048) were significantly lower with the Sapien 3 device. Thirty-day mortality rate was 5.8% for the Portico group vs 4.1% for the Sapien 3 group (P=.74). Complication rates were similar between Portico and Sapien 3 groups: stroke (2.9% vs 4.1%, respectively; P=.31), major bleeding (3.8% vs 5.5%, respectively; P=.51), major vascular complications (5.8% vs 5.5%, respectively; P=.99), and pacemaker implantation (21.9% vs 17.5%, respectively; P=.55). A more-than-mild paravalvular leak was observed in 8.2% vs 4.5%, respectively (P=NS). CONCLUSIONS: Short-term clinical and hemodynamic outcomes were similar with Portico and Sapien 3 prostheses; no statistically significant differences were observed in mortality and major complication rates. An individually tailored prosthesis choice is suggested.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Hemodinâmica/fisiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA