Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Interact Cardiovasc Thorac Surg ; 34(6): 982-989, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34942005

RESUMO

OBJECTIVES: Obesity may increase the risk of vascular complications in transfemoral (TF) transcatheter aortic valve replacement (TAVR) procedures. The transcarotid (TC) approach has recently emerged as an alternative access in TAVR. We sought to compare vascular complications and early clinical outcomes in obese patients undergoing TAVR either by TF or TC vascular access. METHODS: Multicentre registry including obese patients undergoing TF- or TC-TAVR in 15 tertiary centres. All patients received newer-generation transcatheter heart valves. For patients exhibiting unfavourable ileo-femoral anatomic characteristics, the TC approach was favoured in 3 centres with experience with it. A propensity score analysis was performed for overcoming unbalanced baseline covariates. The primary end point was the occurrence of in-hospital vascular complications (Valve Academic Research Consortium-2 criteria). RESULTS: A total of 539 patients were included, 454 (84.2%) and 85 (15.8%) had a TF and TC access, respectively. In the propensity-adjusted cohort (TF: 442 patients; TC: 85 patients), both baseline and procedural valve-related characteristics were well-balanced between groups. A significant decrease in vascular complications was observed in the TC group (3.5% vs 12% in the TF group, odds ratio: 0.26, 95% CI: 0.07-0.95, P = 0.037). There were no statistically significant differences between groups regarding in-hospital mortality (TC: 2.8%, TF: 1.5%), stroke (TC: 1.2%, TF: 0.4%) and life-threatening/major bleeding events (TC: 2.8%, TF: 3.8%). CONCLUSIONS: In patients with obesity undergoing TAVR with newer-generation devices, the TC access was associated with a lower rate of vascular complications. Larger randomized studies are warranted to further assess the better approach for TAVR in obese patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Humanos , Obesidade/complicações , Obesidade/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
J Am Heart Assoc ; 10(12): e019051, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34056919

RESUMO

Background There is a paucity of outcome data on patients who are morbidly obese (MO) undergoing transcatheter aortic valve replacement. We aimed to determine their periprocedural and midterm outcomes and investigate the impact of obesity phenotype. Methods and Results Consecutive patients who are MO (body mass index, ≥40 kg/m2, or ≥35 kg/m2 with obesity-related comorbidities; n=910) with severe aortic stenosis who underwent transcatheter aortic valve replacement in 18 tertiary hospitals were compared with a nonobese cohort (body mass index, 18.5-29.9 kg/m2, n=2264). Propensity-score matching resulted in 770 pairs. Pre-transcatheter aortic valve replacement computed tomography scans were centrally analyzed to assess adipose tissue distribution; epicardial, abdominal visceral and subcutaneous fat. Major vascular complications were more common (6.6% versus 4.3%; P=0.043) and device success was less frequent (84.4% versus 88.1%; P=0.038) in the MO group. Freedom from all-cause and cardiovascular mortality were similar at 2 years (79.4 versus 80.6%, P=0.731; and 88.7 versus 87.4%, P=0.699; MO and nonobese, respectively). Multivariable analysis identified baseline glomerular filtration rate and nontransfemoral access as independent predictors of 2-year mortality in the MO group. An adverse MO phenotype with an abdominal visceral adipose tissue:subcutaneous adipose tissue ratio ≥1 (VAT:SAT) was associated with increased 2-year all-cause (hazard ratio [HR], 3.06; 95% CI, 1.20-7.77; P=0.019) and cardiovascular (hazard ratio, 4.11; 95% CI, 1.06-15.90; P=0.041) mortality, and readmissions (HR, 1.81; 95% CI, 1.07-3.07; P=0.027). After multivariable analysis, a (VAT:SAT) ratio ≥1 remained a strong predictor of 2-year mortality (hazard ratio, 2.78; P=0.035). Conclusions Transcatheter aortic valve replacement in patients who are MO has similar short- and midterm outcomes to nonobese patients, despite higher major vascular complications and lower device success. An abdominal VAT:SAT ratio ≥1 identifies an obesity phenotype at higher risk of adverse clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Obesidade Mórbida/complicações , Substituição da Valva Aórtica Transcateter , Adiposidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Índice de Massa Corporal , Europa (Continente) , Feminino , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Masculino , Obesidade Mórbida/diagnóstico , Obesidade Mórbida/mortalidade , Fenótipo , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Gordura Subcutânea/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA