Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 62(1): 264-73, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25137720

RESUMO

Capacitive electrodes are a promising alternative to the conventional adhesive electrodes for ECG measurements. They provide more comfort to the patient when integrated in everyday objects (e.g., beds or seats) for long-term monitoring. However, the application of capacitive sensors is limited by their high sensitivity to motion artifacts. For example, motion at the body-electrode interface causes variations of the coupling capacitance which, in the presence of a dc voltage across the coupling capacitor, create strong artifacts in the measurements. The origin, relevance, and reduction of this specific and important type of artifacts are studied here. An injection signal is exploited to track the variations of the coupling capacitance in real time. This information is then used by an identification scheme to estimate the artifacts and subtract them from the measurements. The method was evaluated in simulations, lab environments, and in a real-life recording on an adult's chest. For the type of artifact under study, a strong artifact reduction ranging from 40 dB for simulated data to 9 dB for a given real-life recording was achieved. The proposed method is automated, does not require any knowledge about the measurement system parameters, and provides an online estimate for the dc voltage across the coupling capacitor.


Assuntos
Algoritmos , Artefatos , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Movimento , Capacitância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Humanos , Movimento (Física) , Sistemas On-Line , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
2.
Artigo em Inglês | MEDLINE | ID: mdl-25570341

RESUMO

Many healthcare and lifestyle applications could benefit from capacitive measurement systems for unobtrusive ECG monitoring. However, a key technical challenge remains: the susceptibility of such systems to motion artifacts and common-mode interferences. With this in mind, we developed a novel method to reduce various types of artifacts present in capacitive ECG measurement systems. The objective is to perform ECG reconstruction and channel balancing in an automated and continuous manner. The proposed method consists of a) modeling the measurement system; b) specifically parameterizing the reconstruction equation; and c) adaptively estimating the parameters. A multi-frequency injection signal serves to estimate and track the variations of the different parameters of the reconstruction equation. A preliminary investigation on the validity of the method has been performed in both simulation and lab environment: the method shows benefits in terms of common-mode interference and motion artifact reduction, resulting in improved R-peak detection.


Assuntos
Eletrocardiografia/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Artefatos , Automação , Capacitância Elétrica , Eletrodos , Humanos , Processamento de Imagem Assistida por Computador , Injeções , Movimento (Física) , Software , Fatores de Tempo
3.
Physiol Meas ; 35(5): 895-913, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24743027

RESUMO

The thin skin of preterm babies is easily damaged by adhesive electrodes, tapes, chest drains and needle-marks. The scars caused could be disfiguring or disabling to 10% of preterm newborns. Capacitive sensors present an attractive option for pervasively monitoring neonatal ECG, and can be embedded in a support system or even a garment worn by the neonate. This could improve comfort and reduce pain aiding better recovery as well as avoiding the scars caused by adhesive electrodes. In this work, we investigate the use of an array of capacitive sensors unobtrusively embedded in a mattress and used in a clinical environment for 15 preterm neonates. We also describe the analysis framework including the fusion of information from all sensors to provide a more accurate ECG signal. We propose a channel selection strategy as well as a method using physiological information to obtain a reliable ECG signal. When sensor coverage is well attained, results for both instantaneous heart rate and ECG signal shape analysis are very encouraging. The study also provides several insights on important factors affecting the results. These include the effect of textile type, number of layers, interferences (e.g. people walking by), motion severity and interventions. Incorporating this knowledge in the design of a capacitive sensing system would be crucial in ensuring that these sensors provide a reliable ECG signal when embedded in a neonatal support system.


Assuntos
Capacitância Elétrica , Eletrocardiografia/instrumentação , Unidades de Terapia Intensiva Neonatal , Monitorização Fisiológica/instrumentação , Leitos , Eletrodos , Humanos , Recém-Nascido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA