Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 32(9): 2783-2787, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28511948

RESUMO

BACKGROUND: Noise after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a well-recognized problem. Computer navigation has been shown to achieve desired implant orientation. Our aim was (1) to compare the incidence of noise between navigated and conventional CoC THAs and (2) to determine the factors associated with noise. METHODS: All patients undergoing CoC THA between March 2009 and August 2012 were considered for this study. Information regarding hip noise was obtained via telephone or postal interview. A comparable cohort of patients in navigated and conventional groups was used to evaluate the incidence of noise. RESULTS: A total of 375 CoC THAs using the same implant (202 navigated and 173 conventional) were evaluated. Patients <65 years of age had significantly greater incidence of noise (22.4% vs 6.1%; P < .001). To ensure similarity, a subgroup of cohort <65 years and a 32-mm head size was used to compare the incidence of noise between the navigated (68 THAs) and conventional (118 THAs) groups. Overall incidence of noise was significantly greater in the conventional group (28%) as compared with the navigated group (10%; P = .005). The relative risk of noise for the conventional vs the navigated group was 2.7 (P = .01), and for squeaking was 1.9 (P = .2). Squeaking THAs had significantly lower cup anteversion (13.4° ± 5.2°) as compared with the silent THAs (17.6° ± 6.9°; P = .01). CONCLUSION: Navigated CoC THAs were 2.7× less likely to have noise as compared with the conventional ones. Squeaking THAs had significantly lower cup anteversion as compared with the silent ones. Patients of age <65 years had significantly greater incidence of noise after CoC THA.


Assuntos
Artroplastia de Quadril , Cerâmica , Diagnóstico por Computador , Prótese de Quadril , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Incidência , Masculino , Pessoa de Meia-Idade , Ruído , Estudos Prospectivos , Software , Interface Usuário-Computador
2.
J Arthroplasty ; 32(9): 2852-2856, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28529109

RESUMO

BACKGROUND: Dislocation is a leading cause of revision after primary total hip arthroplasty (THA). Although more common in the first few years after the procedure, dislocation can occur at any time. This study investigated the difference in late dislocation in ceramic-on-ceramic (CoC) bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings in THA. METHODS: Data were used from the Australian Orthopaedic Association National Joint Replacement Registry, and the cumulative percent revision for dislocation was estimated using the Kaplan-Meier method for the different bearing surfaces. There were 192,275 THAs included in the study with 101,915 metal-on-cross-linked polyethylene (MoXLPE), 30,256 ceramic-on-cross-linked polyethylene (CoXLPE), and 60,104 CoC. RESULTS: The cumulative percent revision for dislocation at 13 years for MoXLPE, CoXLPE, and CoC groups was 1.2 (95% confidence interval [CI], 1.1-1.3), 1.0 (95% CI, 0.7-1.4), and 0.9 (95% CI, 0.8-1.1), respectively. There was an increased risk of revision for dislocation for MoXLPE compared with CoXLPE and CoC. When stratified for head size, there was no difference in the risk of revision for dislocation between MoXLPE, CoXLPE, and CoC in the 28- and 32-mm head sizes. With a head size of 36 mm, MoXLPE had a higher rate of dislocation compared with other materials. CONCLUSION: Bearing surface has little impact on revision for dislocation.


Assuntos
Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/etiologia , Prótese de Quadril/efeitos adversos , Materiais Biocompatíveis , Cerâmica , Humanos , Masculino , Metais , Polietileno , Desenho de Prótese/efeitos adversos , Falha de Prótese , Sistema de Registros , Reoperação
3.
Arthroplasty ; 3(1): 41, 2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-35236503

RESUMO

BACKGROUND: Limb and implant alignment along with soft tissue balance plays a vital role in the outcomes after total knee arthroplasty (TKA). Computer navigation for TKA was first introduced in 1997 with the aim of implanting the prosthetic components with accuracy and precision. This review discusses the technique, current status, and scientific evidence pertaining to computer-navigated TKA. BODY: The adoption of navigated TKA has slowly but steadily increased across the globe since its inception 25 years ago. It has been more rapid in some countries like Australia than others, like the UK. Contemporary, large console-based navigation systems help control almost every aspect of TKA, including the depth and orientation of femoral and tibial resections, soft-tissue release, and customization of femoral and tibial implant positions in order to obtain desired alignment and balance. Navigated TKA results in better limb and implant alignment and reduces outliers as compared to conventional TKA. However, controversy still exists over whether improved alignment provides superior function and longevity. Surgeons may also be hesitant to adopt this technology due to the associated learning curve, slightly increased surgical time, fear of pin site complications, and the initial set-up cost. Furthermore, the recent advent of robotic-assisted TKA which provides benefits like precision in bone resections and avoiding soft-tissue damage due to uncontrolled sawing, in addition to those of computer navigation, might be responsible for the latter technology taking a backseat. CONCLUSION: This review summarizes the current state of computer-navigated TKA. The superiority of computer navigation to conventional TKA in improving accuracy is well established. Robotic-assisted TKA provides enhanced functionality as compared to computer navigation but is significantly more expensive. Whether robotic-assisted TKA offers any substantive advantages over navigation is yet to be conclusively proven. Irrespective of the form, the use of computer-assisted TKA is on the rise worldwide and is here to stay.

4.
Indian J Radiol Imaging ; 30(4): 500-503, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33737780

RESUMO

The COL4A1 gene (COL4A1) plays an important role in vascular basement membrane function and pathogenic mutations have been reported in mice and humans. The gene is expressed mainly in the human brain, eyes and kidneys. Pathogenic mutations result in a vast array of manifestations that can present throughout life including the foetal period. We present a case of an 11-year-old girl with right hemiparesis, congenital cataracts, epilepsy and magnetic resonance imaging (MRI) brain findings with a pathogenic COL4A1 mutation. Many of her clinical features are similar to those of a non-genetic cause of cerebral palsy highlighting the difficulties and delays in making this genetic diagnosis.

5.
J Orthop ; 18: 171-176, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32042221

RESUMO

BACKGROUND: Navigated total knee arthroplasty (TKA) improves implant and limb alignment but outliers continue to exist. This study aimed to determine the technical and surgical causes of outliers. METHODS: This retrospective cohort study included 208 patients who had undergone navigated TKA. Limb and implant alignment indices were measured on post-operative CT scans: mechanical femoro-tibial angle (MFTA); coronal femoral angle (CFA); coronal tibial angle (CTA); sagittal femoral angle (SFA); and sagittal tibial angle (STA). Values outside 0°±3° for MFTA and SFA, 90°±3° for CFA, CTA and STA were considered outliers. Intra-operative navigation data and CT scans were evaluated to categorize the causes of sagittal and coronal plane outliers into hip centre error; ankle centre error; heterogeneous tibial cement mantle; malalignment accepted by surgeon; suboptimal knee balance; and no obvious explanation. RESULTS: Of the 1040 measurements (five per TKA), the overall incidence of outliers was 10.4% (n = 108). Femoral component outliers (CFA + SFA, n = 51) were all attributable to hip centre error. Tibial component outliers (CTA + STA, n = 43) were attributable to ankle centre error (n = 6), heterogeneous cement mantle (n = 20), malalignment accepted by the surgeon (n = 6) and no obvious cause (n = 11). MFTA outliers were attributable to hip centre error (n = 4) or suboptimal knee balance (n = 10). CONCLUSIONS: Surgeon related errors can be minimized by a meticulous operative technique. These results indicate scope for additional technical improvement, especially in hip centre acquisition, which may further reduce the incidence of outliers.

6.
J Orthop ; 16(6): A1-A3, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32395040

RESUMO

The femoral head size influences dislocation, range of motion (ROM), functional outcome, wear, and survival after total hip arthroplasty (THA). These aspects of different head sizes with contemporary bearings in primary THA have been reviewed. Based on the existing evidence, for highly-cross-linked polyethylene (HXLPE) bearings, a 32 mm cobalt chromium (CoCr) or ceramic head appears to be a suitable choice. If a 36 mm head with HXLPE is desired, a ceramic head may be preferable over CoCr due to reduced risk of fretting and corrosion with the former. For ceramic-on-ceramic (CoC) bearings, head sizes >36 mm do not appear to provide any significant benefit over 36 mm heads. Also, large ceramic heads may lead to increased risk of squeaking. If non-cross-linked PE bearing is considered for use, it would be prudent to opt for <32 mm head size.

7.
Indian J Orthop ; 47(3): 250-4, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23798755

RESUMO

BACKGROUND: Anterior fixation using two 3.5 mm screws is typically recommended for type II odontoid fractures. However, it is unsuitable in patients with an odontoid diameter of <9.0 mm. There is no data regarding the morphology of odontoid process in the Indian population. The aim of our study was to: a) Measure the external diameters of odontoid process in the Indian population using CT scan and thus determine the feasibility of two 3.5 mm screw fixation in them. b) Determine if any correlation exists between body height (Ht) and weight (Wt) and external odontoid diameters. MATERIALS AND METHODS: CT images of odontoid process of 100 consecutive patients were analyzed. Antero- posterior (AP) and transverse (TD), outer diameters of the odontoid process were measured from the base and at 1 mm interval upwards on axial CT images. RESULTS: The mean AP and mean TD were 11.52 mm and 9.85 mm, respectively. Fifty-five (55%) of the patients had at least one TD <9.0 mm. Five (5%) patients had at least one TD <7.4 mm. None of the patients had any diameter <5.5 mm. Body Ht correlated significantly with mean AP and mean TD of the odontoid process (AP: r = 0.276, P = 0.013; TD: r = 0.359, P = 0.001), whereas body Wt correlated significantly only with mean TD (AP: r = 0.162, P = 0.15; TD: r = 0.297, P = 0.007). CONCLUSION: More than half of the study population (55%) was unsuitable for two 3.5 mm screw fixation for type II odontoid fracture. Two 2.7 mm screws can be safely used in 95% of the population. A 4.5 mm Herbert screw can be safely used in the entire population. We recommend two 2.7 mm screws or a 4.5 mm Herbert screw for fixation of these fractures in the Indian population. Body height showed a significant correlation with external odontoid diameters, whereas weight showed significant correlation only with TD of the odontoid process.

8.
Asian Spine J ; 7(4): 314-21, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24353849

RESUMO

STUDY DESIGN: A prospective observational study. PURPOSE: To evaluate the role of nucleoplasty in the management of discogenic axial back pain; to determine the influence of concordant pain during provocative discography, annular tear and loss of disc height on the outcome of nucleoplasty. OVERVIEW OF LITERATURE: The role of nucleoplasty in the management of radicular leg pain due to disc herniation is known. However, the data regarding its role in the management of discogenic axial back pain is scarce. METHODS: A prospective evaluation of 30 patients with discogenic axial back pain undergoing nucleoplasty was performed. Pain, functional disability and quality of life were assessed using the 100 mm visual analogue scale (VAS), Oswestry Disability Index (ODI) and Short Form-36 (SF-36), respectively. RESULTS: The mean reduction in VAS was 31.03 and 29.03; mean reduction in ODI was 24.53 and 20.60; and mean increment in SF-36 was 13.58 and 12.30, at 6 months and at 12 months, respectively. The differences were statistically significant (p <0.05). Concordant pain during provocative discography, annular tear and loss of disc height did not affect a clinically significant improvement in any of the three outcomes (p =0.882, 0.213, and 0.170; respectively). CONCLUSIONS: Nucleoplasty produced statistically significant improvements in pain, functional disability and quality of life in patients with discogenic low back pain at 6 months and at 12 months. Concordant pain during provocative discography, annular tear and loss of disc height did not influence any of the outcomes after nucleoplasty in patients with discogenic axial back pain.

9.
Indian J Orthop ; 45(5): 470-2, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21886932

RESUMO

Prophylactic or therapeutic arthrodesis is recommended for atlantoaxial instability in Morquio syndrome. Occipitocervical fusion, the common approach for upper cervical fusion in Morquio syndrome sacrifices the movements at the occipitoatlantal joints. The use of C1-C2 transarticular screws for achieving C1-C2 arthrodesis, without compromising mobility at the occipitoatlantal joint in Morquio syndrome has not been reported. We report a case of Morquio syndrome with atlantoaxial instability and odontoid hypoplasia, where we successfully achieved C1-C2 arthrodesis using transarticular screws and bone graft. The advantages of this method over other methods of atlantoaxial arthrodesis in Morquio syndrome have also been discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA