Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
AJR Am J Roentgenol ; 218(3): 526-533, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34643106

RESUMO

BACKGROUND. Use of upper gastrointestinal (UGI) series to diagnose UGI obstruction in neonates and infants has raised concern about increased radiation sensitivity of developing organs. OBJECTIVE. The purpose of this study was to assess the diagnostic performance of saline-aided ultrasound (US) in comparison with UGI series in evaluation for UGI obstruction in neonates and infants. METHODS. In this prospective multicenter study at three hospitals, inpatients were enrolled who were younger than 1 year and had suspected UGI obstruction between June 2015 and May 2018; patients with US evidence of malrotation or pyloric stenosis were ineligible. Enrolled patients underwent both saline-aided US (saline solution administered through a nasogastric tube) and UGI series. Surgical findings or at least 1-year of clinical follow-up findings served as the reference for presence of UGI obstruction. UGI obstruction was classified in terms of level (proximal vs distal) and cause. Two radiologists independently interpreted saline-aided US examinations to assess interobserver agreement and then reached consensus. Two other radiologists assessed upper GI series in consensus. Diagnostic performance for the presence and level of UGI obstruction was compared between modalities. Causes of obstruction were assessed with saline-aided US. RESULTS. A total of 209 neonates were included (116 boys, 93 girls; median age, 5 days; 124 (59.3%) patients had UGI obstruction (proximal in 108 patients). Saline-aided US had strong interobserver agreement for presence (κ = 0.87) and level (κ = 0.85) of obstruction. For presence of UGI obstruction, accuracy, sensitivity, and specificity were 94.7%, 98.4%, and 89.4% for saline-aided US and 89.5%, 95.2%, and 81.2% for UGI series. For obstruction level, accuracy, sensitivity, and specificity were 90.3%, 97.2%, and 56.3% for saline-aided US versus 87.1%, 92.6%, and 50.0% for UGI series. Accuracy for presence was significantly higher for saline-aided US (p = .02); otherwise, these metrics were not different between tests (p > .05). For causes of UGI obstruction (annular pancreas, duodenal web, duodenal atresia, and duodenal stenosis), the accuracy of saline-aided US ranged from 75.0% to 95.2%. CONCLUSION. Saline-aided US has high diagnostic performance for presence and level of UGI obstruction in neonates and infants, comparing favorably with UGI series. Saline-aided US may have additional utility in evaluating causes of obstruction. CLINICAL IMPACT. Saline-aided US may serve as an initial screening modality for UGI obstruction in neonates and infants. TRIAL REGISTRATION. Chinese Clinical Trial Registry ChiCTR-DCC-15006232.


Assuntos
Trato Gastrointestinal/diagnóstico por imagem , Obstrução Intestinal/diagnóstico por imagem , Solução Salina/administração & dosagem , Ultrassonografia/métodos , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos
2.
BMC Gastroenterol ; 22(1): 517, 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36513975

RESUMO

OBJECTIVE: The main aim of this study was to analyze the performance of different artificial intelligence (AI) models in endoscopic colonic polyp detection and classification and compare them with doctors with different experience. METHODS: We searched the studies on Colonoscopy, Colonic Polyps, Artificial Intelligence, Machine Learning, and Deep Learning published before May 2020 in PubMed, EMBASE, Cochrane, and the citation index of the conference proceedings. The quality of studies was assessed using the QUADAS-2 table of diagnostic test quality evaluation criteria. The random-effects model was calculated using Meta-DISC 1.4 and RevMan 5.3. RESULTS: A total of 16 studies were included for meta-analysis. Only one study (1/16) presented externally validated results. The area under the curve (AUC) of AI group, expert group and non-expert group for detection and classification of colonic polyps were 0.940, 0.918, and 0.871, respectively. AI group had slightly lower pooled specificity than the expert group (79% vs. 86%, P < 0.05), but the pooled sensitivity was higher than the expert group (88% vs. 80%, P < 0.05). While the non-experts had less pooled specificity in polyp recognition than the experts (81% vs. 86%, P < 0.05), and higher pooled sensitivity than the experts (85% vs. 80%, P < 0.05). CONCLUSION: The performance of AI in polyp detection and classification is similar to that of human experts, with high sensitivity and moderate specificity. Different tasks may have an impact on the performance of deep learning models and human experts, especially in terms of sensitivity and specificity.


Assuntos
Pólipos do Colo , Humanos , Pólipos do Colo/diagnóstico , Inteligência Artificial , Colonoscopia/métodos , Sensibilidade e Especificidade , Área Sob a Curva
3.
AJR Am J Roentgenol ; 214(6): 1377-1383, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32160054

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous transhepatic cholangial drainage (PTCD) and consequent percutaneous US cholangiography in managing the dilated biliary tracts of children who have undergone hepatobiliary surgery. SUBJECTS AND METHODS. Sixteen children (11 boys, five girls; age range, 3-144 months) who underwent hepatobiliary surgery from December 2016 to October 2018 and had US evidence of biliary dilatation were included. All patients had undergone US-guided PTCD because of elevated postoperative serum bilirubin levels or bile duct infection. Immediately after the PTCD procedure, diluted sulphur hexafluoride microbubbles dispersion was injected through the PTCD tube to evaluate the anastomosis and the intrahepatic bile duct tree. Laboratory results, including those of serum bilirubin measurement, liver function tests, and routine blood tests, were evaluated before and after PTCD. Nine of 16 patients also underwent percutaneous transhepatic cholangiography (PTC). The percutaneous US cholangiography findings were evaluated and compared with the PTC findings. RESULTS. Liver enzyme levels decreased after PTCD with a statistically significant difference from the values before PTCD. Percutaneous US cholangiography showed that the anastomosis in 6 of the 16 patients (37.5%) was patent and depicted the morphologic featuresof intrahepatic bile duct tree in five of these patients. In the other 10 patients, the anastomosis was completely obstructed, and percutaneous US cholangiography depicted the morphologic features of intrahepatic bile duct tree in eight patients. In the nine patients who underwent PTC, the percutaneous US cholangiographic findings were the same as the PTC findings. CONCLUSION. US-guided PTCD is helpful in relieving jaundice and inflammation in children who have undergone hepatobiliary surgery and have biliary dilatation. Findings at consequent percutaneous US cholangiography are comparable to those of PTC in depicting the anastomosis in these patients.


Assuntos
Doenças Biliares/cirurgia , Colangiografia , Drenagem/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Ultrassonografia de Intervenção , Ductos Biliares Intra-Hepáticos , Bilirrubina/sangue , Criança , Pré-Escolar , Meios de Contraste , Dilatação Patológica , Estudos de Viabilidade , Feminino , Humanos , Lactente , Testes de Função Hepática , Masculino , Microbolhas
4.
Am J Otolaryngol ; 41(6): 102625, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32668355

RESUMO

OBJECTIVE: To compare diagnostic performance and malignancy risk stratification among guidelines set forth by the American Thyroid Association (ATA) in 2015, the American Association of Clinical Endocrinologists (AACE), the American College of Endocrinology (ACE) and the Association Medici Endocrinologi (AME) in 2016, and the American College of Radiology (ACR) in 2017. METHODS: The retrospective study was approved by the hospital ethics committee, and the informed consent requirement was waived. From October 2015 to March 2016, a total of 230 patients with 230 consecutive thyroid nodules were enrolled in this study. Each nodule was classified by one junior and one senior radiologist separately according to ACR TI-RADS, AACE/ACE/AME and ATA guidelines. The malignancy diagnostic performance and the number of FNA recommendations were pairwise compared among three guidelines using chi-square tests. RESULTS: Of the 230 thyroid nodules, 137 were malignant, and 93 were benign. However, 19.6% of the nodules (45 of 230) did not match any pattern using the ATA guidelines but with a high risk of malignancy (68.9%). The ACR TI-RADS derived the highest diagnostic performance, from both junior radiologist (AUC 0.815) and senior radiologist (AUC 0.864). The ACR guidelines also showed the greatest level of sensitivity (junior: 86.1%, senior: 94.9%), compared with AACE/ACE/AME and ATA guidelines. The number of thyroid nodules recommended to fine-needle aspiration (FNA) was the lowest (37.8%, 40.4%) by ACR TI-RADS, and meanwhile, the malignant detection rate within these nodules was highest (64.4%, 68.8%). CONCLUSIONS: The ACR guidelines present a higher level of diagnostic indicators and may offer a meaningful reduction in FNA recommendations with a higher malignancy detection rate.


Assuntos
Biópsia por Agulha Fina , Endocrinologia/organização & administração , Guias de Prática Clínica como Assunto , Radiologia/organização & administração , Sociedades Médicas/organização & administração , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/patologia , Adolescente , Adulto , Idoso , Biópsia por Agulha Fina/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Risco , Adulto Jovem
5.
Radiol Med ; 125(8): 697-705, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32200455

RESUMO

PURPOSE: To test the technical reproducibility of acquisition and scanners of CT image-based radiomics model for early recurrent hepatocellular carcinoma (HCC). METHODS: We included primary HCC patient undergone curative therapies, using early recurrence as endpoint. Four datasets were constructed: 109 images from hospital #1 for training (set 1: 1-mm image slice thickness), 47 images from hospital #1 for internal validation (sets 2 and 3: 1-mm and 10-mm image slice thicknesses, respectively), and 47 images from hospital #2 for external validation (set 4: vastly different from training dataset). A radiomics model was constructed. Radiomics technical reproducibility was measured by overfitting and calibration deviation in external validation dataset. The influence of slice thickness on reproducibility was evaluated in two internal validation datasets. RESULTS: Compared with set 1, the model in set 2 indicated favorable prediction efficiency (the area under the curve 0.79 vs. 0.80, P = 0.47) and good calibration (unreliability statistic U: P = 0.33). However, in set 4, significant overfitting (0.63 vs. 0.80, P < 0.01) and calibration deviation (U: P < 0.01) were observed. Similar poor performance was also observed in set 3 (0.56 vs. 0.80, P = 0.02; U: P < 0.01). CONCLUSIONS: CT-based radiomics has poor reproducibility between centers. Image heterogeneity, such as slice thickness, can be a significant influencing factor.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Recidiva Local de Neoplasia/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Algoritmos , Biomarcadores Tumorais/análise , Carcinoma Hepatocelular/cirurgia , Meios de Contraste , Feminino , Hepatectomia , Humanos , Iohexol/análogos & derivados , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco
6.
J Ultrasound Med ; 38(9): 2447-2455, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30680769

RESUMO

OBJECTIVES: The aim of this study was to evaluate the influence of fasting time on the ultrasound identification and exclusion of biliary atresia in jaundiced infants through the use of the gallbladder classification scheme and to test the value of the gallbladder classification scheme in the diagnosis of biliary atresia in inexperienced individuals. METHODS: A total of 188 jaundiced infants were enrolled in this study. All patients received detailed abdominal sonograms. Diagnoses were confirmed via liver biopsy, surgical findings, or follow-up. Infants were grouped into either the fasting group (fasting time ≥ 4 h) or the nonfasting group (fasting time < 4 h). According to the gallbladder classification scheme, the gallbladders were classified into 4 types. The accuracy of diagnosing biliary atresia based on the gallbladder classification scheme was compared between the 2 groups. The gallbladders of 177 infants that were detectable by ultrasonography were used to compare the diagnostic performances between a junior radiologist and an experienced radiologist. RESULTS: The accuracies in the diagnosis of biliary atresia with the gallbladder classification scheme were 86.3% (82 of 95 patients) for the fasting group and 93.5% (87 of 93 patients) for the nonfasting group (P = .100). The diagnostic accuracies of biliary atresia were 88.7% (157 of 177 patients) for the junior radiologist and 90.4% (160 of 177 patients) for the experienced radiologist (P = .250). The κ value for the agreement between the 2 radiologists was 0.859. CONCLUSIONS: The performance of gallbladder diagnoses was not influenced by the fasting time with the use of the gallbladder classification scheme. Additionally, the gallbladder classification scheme may help junior radiologists to more effectively identify biliary atresia and nonbiliary atresia.


Assuntos
Atresia Biliar/diagnóstico por imagem , Atresia Biliar/fisiopatologia , Jejum/fisiologia , Vesícula Biliar/diagnóstico por imagem , Vesícula Biliar/fisiopatologia , Ultrassonografia/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Fatores de Tempo
7.
Dig Dis ; 36(3): 228-235, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29353268

RESUMO

AIM: To confirm whether cirrhosis is indispensable for the non-invasive diagnostic criteria for hepatocellular carcinoma (HCC) in hepatitis B virus (HBV)-endemic areas. METHODS: Between January 2014 and December 2014, a total of 409 patients with pathologically proven focal liver lesions who underwent contrast-enhanced ultrasound (CEUS) were recruited from our institution. Clinical liver cirrhosis, HBV/HCV infection and HCC-typical vascular pattern of the targeted lesion on CEUS were evaluated. The following 3 criteria were applied to these patients to diagnose HCC: criterion 1, clinical liver cirrhosis and HCC-typical vascular pattern; criterion 2, HBV/HCV infection and HCC-typical vascular pattern; criterion 3, HBV/HCV infection or clinical liver cirrhosis and HCC-typical vascular pattern. Pathological reports were considered the gold standard. RESULTS: A total of 311 patients had confirmed HCC by pathology. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and area under the ROC curve for criterion 1 were 29.6, 90.8, 44.3, 91.1, 28.9, and 0.60% respectively. For criterion 2, they were 83.3, 74.5, 81.2, 91.2, 58.4, and 0.79%, respectively, and for criterion 3, they were 86.2, 72.5, 82.9, 90.9, 62.3, and 0.79% respectively. CONCLUSIONS: In HBV-endemic areas, when using the HBV/HCV infection instead of cirrhosis as the precondition of the non-invasive diagnostic criteria for HCC, we should be aware of the potential false positive. Cirrhosis still plays an important role in the non-invasive diagnostic criteria for HCC because of the high specificity.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/virologia , Doenças Endêmicas , Vírus da Hepatite B/fisiologia , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/virologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Meios de Contraste/química , Feminino , Hepatite B/complicações , Hepatite B/diagnóstico por imagem , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade
8.
Eur Radiol ; 27(8): 3474-3484, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28083694

RESUMO

OBJECTIVES: To prospectively assess the diagnostic performance of supersonic shear wave elastography (SSWE) in identifying biliary atresia (BA) among infants with conjugated hyperbilirubinaemia by comparing this approach with grey-scale ultrasonography (US). METHODS: Forty infants were analysed as the control group to determine normal liver stiffness values. The use of SSWE values for identifying BA was investigated in 172 infants suspected of having BA, and results were compared with the results obtained by grey-scale US. The Mann-Whitney U test, unpaired t-test, Spearman correlation and linear regression were also performed. RESULTS: The success rates of SSWE measurements in the control and study group were 100% (40/40) and 96.4% (244/253), respectively. Age, direct bilirubin, and indirect bilirubin all significantly correlated with SSWE in the liver (all P < 0.001). Linear regression showed that age had a greater effect on SSWE values than direct or indirect bilirubin. The diagnostic performance of liver stiffness values in identifying BA was lower than that of grey-scale US (area under the receiver operating characteristic curve [AUC], 0.790 vs 0.893, P < 0.001). CONCLUSIONS: SSWE is feasible and valuable in differentiating BA from non-BA. However, its diagnostic performance does not exceed that of grey-scale US. KEY POINTS: • SSWE could be successfully performed in an infant population. • For infants, the liver stiffness will increase as age increases. • SSWE is potentially useful in assessing infants suspected of biliary atresia. • SSWE is inferior to grey-scale US in identifying biliary atresia.


Assuntos
Atresia Biliar/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Atresia Biliar/complicações , Bilirrubina/sangue , Estudos de Casos e Controles , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Hiperbilirrubinemia/diagnóstico por imagem , Hiperbilirrubinemia/etiologia , Lactente , Recém-Nascido , Cirrose Hepática/etiologia , Masculino , Curva ROC , Reprodutibilidade dos Testes , Ultrassonografia/métodos
9.
AJR Am J Roentgenol ; 206(5): W73-82, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27010179

RESUMO

OBJECTIVE: The purpose of this meta-analysis was to summarize the evidence on the accuracy of various ultrasound findings for excluding a diagnosis of biliary atresia. MATERIALS AND METHODS: We searched MEDLINE and the Web of Science databases for the period from January 1990 to May 2015. To be included, studies had to satisfy two criteria. First, the data needed to include 2 × 2 contingency data on the diagnostic accuracy of ultrasound in identifying biliary atresia in at least 10 patients with and 10 patients without disease. Second, the study needed to use surgery or biopsy for biliary atresia and surgery, biopsy, clinical follow-up, or some combination of the three as the reference standard for the exclusion of biliary atresia. The methodologic quality of each study was assessed with version 2 of the Quality Assessment of Diagnostic Accuracy Studies tool. Estimated sensitivity and specificity of each ultrasound characteristic were calculated using a random-effects model. RESULTS: Twenty-three studies published during 1998-2015 were included. Summary sensitivity and specificity were 0.85 (95% CI, 0.76-0.91) and 0.92 (95% CI, 0.81-0.97), respectively, for gallbladder abnormalities in 19 studies; 0.74 (95% CI, 0.61-0.84) and 0.97 (95% CI, 0.95-0.99), respectively, for triangular cord sign in 20 studies; and 0.95 (95% CI, 0.70-0.99) and 0.89 (95% CI, 0.79-0.94), respectively, for the combination of the triangular cord sign and gallbladder abnormalities in five studies. Subgroup analysis of an absent gallbladder in 10 studies yielded a summary specificity of 0.99 (95% CI, 0.93-1.00). CONCLUSION: The triangular cord sign and gallbladder abnormalities are the two most accurate and widely accepted ultrasound characteristics for diagnosing or excluding biliary atresia. Other ultrasound characteristics are less valuable for diagnosis or exclusion of biliary atresia.


Assuntos
Atresia Biliar/diagnóstico por imagem , Vesícula Biliar/diagnóstico por imagem , Humanos , Ultrassonografia
10.
Hepatol Res ; 46(12): 1203-1213, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26857658

RESUMO

AIM: A meta-analysis was carried out to assess the accuracies of shear wave speed imaging (SWSI) in predicting significant fibrosis (stages F2-4) and cirrhosis (stage F4). METHODS: A review was performed of relevant studies published until October 2015. A bivariate binomial model was used to combine the sensitivity, specificity, and the area under the summary receiver operating characteristic (AUC), and 95% confidence intervals were derived to indicate the diagnostic accuracy of imaging modalities. RESULTS: In total, 10 studies with 2182 patients were included in the analysis. The sensitivity, specificity, and AUC (with 95% confidence intervals) of SWSI were: 0.84 (0.81-0.87), 0.83 (0.77-0.88), and 0.88 (0.85-0.90) for significant fibrosis, respectively; and 0.80 (0.66-0.89), 0.93 (0.88-0.96), and 0.95 (0.92-0.96) for cirrhosis, respectively. When SWSI was compared with well-evaluated transient elastography, the AUCs for the prediction of significant fibrosis were 0.93 and 0.86, respectively. The AUCs for the prediction of cirrhosis were both 0.94. CONCLUSION: Shear wave speed imaging is a trustworthy tool for staging hepatic fibrosis, with a high combination of sensitivity and specificity. Compared with transient elastography, SWSI showed better diagnostic performance for the prediction of significant fibrosis.

11.
Radiology ; 277(1): 181-91, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25955579

RESUMO

Purpose To evaluate the diagnostic performance of ultrasonography (US) in the identification and exclusion of biliary atresia with a modified triangular cord thickness metric together with a gallbladder classification scheme, as well as hepatic artery (HA) diameter and liver and spleen size, in a large sample of jaundiced infants. Materials and Methods The ethics committee approved this study, and written informed parental consent was obtained. In 273 infants with conjugated hyperbilirubinemia (total bilirubin level ≥ 31.2 µmol/L, with direct bilirubin level > indirect bilirubin level), detailed abdominal US was performed to exclude biliary atresia. Biliary atresia was found in 129 infants and ruled out in 144. A modified triangular cord thickness was measured at the anterior branch of the right portal vein, and a gallbladder classification scheme was identified that incorporated the appearance of the gallbladder and a gallbladder length-to-width ratio of up to 5.2 when the lumen was visualized, as well as HA diameter and liver and spleen size. Reference standard diagnosis was based on results of one or more of the following: surgery, liver biopsy, cholangiography, and clinical follow-up. Area under the receiver operating characteristic curve (AUC) analysis, binary logistic regression analysis, Fisher exact test, and unpaired t test were performed. Results Triangular cord thickness, HA diameter, ratio of gallbladder length to gallbladder width, liver size, and spleen size exhibited statistically significant differences (all P < .05) between the group with biliary atresia and the group without. AUCs of triangular cord thickness, ratio of gallbladder length to width, and HA diameter were 0.952, 0.844, and 0.838, respectively. Logistic regression analysis demonstrated that these three US parameters were significantly associated (all P < .05) with biliary atresia. The combination of triangular cord thickness and gallbladder classification could yield comparable AUCs (0.915 vs 0.933, P = .400) and a higher sensitivity (96.9% vs 92.2%), compared with triangular cord thickness alone. Conclusion By using the combination of modified triangular cord thickness and gallbladder classification scheme, most infants with biliary atresia could be identified. (©) RSNA, 2015.


Assuntos
Atresia Biliar/diagnóstico por imagem , Vesícula Biliar/diagnóstico por imagem , Atresia Biliar/classificação , Feminino , Vesícula Biliar/patologia , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/patologia , Humanos , Lactente , Recém-Nascido , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Tamanho do Órgão , Baço/diagnóstico por imagem , Baço/patologia , Ultrassonografia
12.
J Ultrasound Med ; 34(10): 1825-32, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26362146

RESUMO

OBJECTIVES: The purpose of this study was to prospectively evaluate the value of sonography in working up or ruling out malrotation by 3 sonographic features (inversion of the superior mesenteric artery and superior mesenteric vein, the whirlpool sign, and an intraperitoneal transverse duodenum) and comparing it with an upper gastrointestinal (GI) contrast study. METHODS: A total of 70 pediatric patients who underwent detailed abdominal sonography to rule out intestinal malrotation were included. Twenty-three of them also underwent an upper GI contrast study. Surgery or clinical follow-up was taken as the reference standard. Statistical analysis was performed with the χ(2) test. RESULTS: Twenty-three patients had a diagnosis of malrotation by surgical findings. With the combination of all 3 sonographic features, the sensitivity, specificity, and accuracy of sonography for determining malrotation were 100% (23 of 23), 97.8% (46 of 47), and 98.6% (69 of 70), respectively, whereas the sensitivity, specificity, and accuracy of the upper GI study were 40% (4 of 10), 64.3% (9 of 14), and 56.5% (13 of 23; P < .001). Combined anomalies in 2 patients and complications in 2 patients were also detected by sonography. CONCLUSIONS: By combining inversion of the superior mesenteric artery and superior mesenteric vein, the whirlpool sign, and an intraperitoneal transverse duodenum, sonography might be more valuable for accurately working up or ruling out pediatric malrotation than an upper GI contrast study. In addition, sonography could provide extra information, such as combined anomalies and intestinal necrosis, to help management.


Assuntos
Volvo Intestinal/diagnóstico por imagem , Ultrassonografia/métodos , Trato Gastrointestinal Superior/anormalidades , Trato Gastrointestinal Superior/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Variações Dependentes do Observador , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Breast Cancer Res Treat ; 137(3): 783-95, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23292085

RESUMO

To present a systematic [corrected] review and meta-analysis to evaluate the nomograms developed to predict non-sentinel lymph node (NSLN) metastasis in breast cancer patients. We focused on the six nomograms (Cambridge, MSKCC, Mayo, MDA, Tenon, and Stanford) that are the most widely validated. The AUCs were converted to odds ratios for the meta-analysis. In total, the Cambridge, Mayo, MDA, MSKCC, Stanford, and Tenon models were validated in 2,156, 2,431, 843, 8,143, 3,700, and 3,648 patients, respectively. The pooled AUCs for the Cambridge, MDA, MSKCC, Mayo, Tenon, and Stanford models were 0.721, 0.706, 0.715, 0.728, 0.720, and 0.688, respectively. Subgroup analysis revealed that in populations with a higher micrometastasis rate in the SLNs, the Tenon and Stanford models had a significantly higher predictive accuracy. A meta-regression analysis revealed that the SLN micrometastasis rate, but not the NSLN-positivity rate, was associated with improved predictive accuracy in the Tenon and Stanford models. The performance of the MSKCC and Cambridge models was not influenced by these two factors. All of these prediction models perform better than random chance. The Stanford model seems to be relatively inferior to the other models. The accuracy of the Tenon and Stanford models is influenced by the tumor burden in the SLNs.


Assuntos
Neoplasias da Mama/diagnóstico , Nomogramas , Biópsia de Linfonodo Sentinela , Neoplasias da Mama/patologia , Feminino , Humanos , Metástase Linfática , Razão de Chances , Prognóstico
14.
Cancer Sci ; 103(2): 274-81, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22054165

RESUMO

Several models for predicting the risk of non-sentinel lymph node (NSLN) metastasis in breast cancer patients with positive sentinel lymph nodes (SLNs) have been developed. The purpose of this study was to validate and compare these models in Chinese patients. A total of 159 breast cancer patients with positive SLNs treated at our institution were included. Among them, 81 (50.9%) patients had at least one NSLN involvement. The Cambridge, Mou, Mayo, Tenon, MDA, Memorial Sloan-Kettering Cancer Center (MSKCC), Ljubljana, SNUH, Turkish, Louisville, Stanford, and Saidi models were evaluated and compared using receiver operating characteristic (ROC) curves, calibration plots, and false negative (FN) rates. The Cambridge and Mou models outperformed the others, both with area under the ROC curves (AUCs) of 0.73. The Mayo, Tenon, MDA, MSKCC, Turkish, Ljubljana, SNUH, and Louisville models had AUCs of 0.68, 0.66, 0.66, 0.64, 0.63, 0.62, 0.61, and 0.60, respectively. The Stanford and Saidi models did not present any discriminative capabilities, with AUCs of 0.54 and 0.50, respectively. The Cambridge, MSKCC, and Mayo models were well calibrated. With adjusted thresholds, the Mayo model outperformed the others by classifying the highest proportion of patients (20%) into the low-risk group. Our study revealed that the Cambridge and Mou models performed well in Chinese patients. The ROC curves, calibration plots, and FN rates should be used together for the accurate evaluation of prediction models. Selection of these models should be based on the clinicopathological features of the targeted population. The models specifically designed for patients with micrometastases or macrometastases of SLNs are needed in the future.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/patologia , Metástase Linfática/patologia , Micrometástase de Neoplasia/patologia , Adulto , Idoso , Mama/patologia , Feminino , Humanos , Excisão de Linfonodo , Linfonodos/patologia , Pessoa de Meia-Idade , Modelos Biológicos , Risco , Biópsia de Linfonodo Sentinela
15.
Diagnostics (Basel) ; 12(5)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35626253

RESUMO

Purpose: To compare the reliability and performance of Supersonic shear wave elastography (S-SWE) and Toshiba shear wave elastography (T-SWE) in the diagnosis of biliary atresia (BA) and assessment of liver fibrosis among jaundiced infants suspected of BA. Material and Methods: A total of 35 patients with suspected BA who underwent both S-SWE and T-SWE examinations were prospectively included. Diagnostic performances of S-SWE and T-SWE in identifying BA were evaluated. The correlation between two types of SWE values and histological liver fibrosis stages by Metavir scores were investigated in 21 patients with pathology results. The intraclass correlation coefficients (ICCs) were calculated in 16 patients for inter- and intra-observer agreement. The area under the receiver operating characteristic curve (AUC) analysis was compared using a DeLong test. Results: There were 22 patients with BA and 13 patients without BA. The diagnostic performance of S-SWE was comparable to that of T-SWE (AUC 0.895 vs. 0.822, p = 0.071) in diagnosing BA. The AUCs of S-SWE in predicting liver fibrosis stages were from 0.676 to 1.000 and showed no statistical differences from that of T-SWE (from 0.704 to 1.000, all p > 0.05). T-SWE provided higher inter-operator agreement (ICC 0.990) and intra-operator agreement (ICCs 0.966−0.993), compared with that of S-SWE in a previous study (ICC 0.980 for inter-operator and 0.930−0.960 for intra-operator). Conclusions: For infants suspected of BA, T-SWE had good performances in the diagnosis of BA and the assessment of liver fibrosis compared with S-SWE. Furthermore, T-SWE showed higher measurement reproducibility than S-SWE.

16.
Indian J Pediatr ; 88(7): 650-655, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33216321

RESUMO

OBJECTIVE: To compare the outcome of biliary atresia (BA) patients with and without hilar cyst on preoperative ultrasound. METHODS: A single center retrospective review of patients of BA with (n = 27) and without hilar cyst (n = 27) over a 5 y period was done. The patients were analyzed using propensity score matching to reduce selection bias. All patients were diagnosed as type III BA by histologic examination and cholangiograms. Clinicopathological characteristics and survival outcomes were compared between the two groups. RESULTS: There were no significant intergroup differences between baseline characteristics and outcomes after Kasai portoenterostomy surgery in two groups. BA with hilar cyst group showed comparable survival outcomes to the BA without cyst group (cumulative 1-y, 2-y and 5-y overall survival rates with native liver 61.4% vs. 65.8%, P = 0.041; 45.0% vs. 49.0%, P = 0.57; 45.0% vs. 49.0%, P = 0.57). And the Kaplan-Meier survival curves showed no significant difference in cumulative survival with native liver between the two groups (P = 0.58). CONCLUSIONS: Type III BA with hilar cyst had no better prognosis compared with Type III BA without cyst.


Assuntos
Atresia Biliar , Cistos , Atresia Biliar/complicações , Atresia Biliar/diagnóstico , Atresia Biliar/cirurgia , Cistos/cirurgia , Humanos , Lactente , Portoenterostomia Hepática , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
17.
Clin Transl Oncol ; 22(3): 401-410, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31172445

RESUMO

PURPOSE: Hepatitis B core antibody (HBcAb) positivity is regarded as a sensitive marker for occult and prior hepatitis B virus (HBV) infection. However, the prognosis of patients with HBcAb-positive in non-B, non-C hepatocellular carcinoma (NBNC-HCC) remains unclear. The study aimed to compare the clinicopathological characteristics of patients with HBcAb-positive NBNC-HCC to those with overt HBV (hepatitis B surface antigen positive) HCC. METHODS: 306 HCC patients underwent hepatectomy were divided into two groups: an overt HBV-HCC group and HBcAb-positive NBNC-HCC group. Then patients were analyzed using propensity score matching (PSM) to reduce selection bias. Clinicopathological characteristics and survival outcomes were compared between the two groups. Univariate and multivariate analysis for risk factors were also evaluated. RESULTS: HBcAb-positive NBNC-HCC group showed comparable survival outcomes to the overt HBV-HCC group (3-year overall survival rates 66% vs 62%, 69% vs 53%; 3-year recurrence-free survival rates 49% vs 40%, 47% vs 37%; P > 0.05) before and after PSM. Patients with HBcAb-positive NBNC-HCC were older, had more complications, higher proportions of vascular invasion, and larger tumor sizes but lower proportions of cirrhosis, elevated alanine aminotransferase and prothrombin time. CONCLUSIONS: HBcAb-positive NBNC-HCC group had more advanced tumors, but their prognosis was relatively comparable to that of the other group. Therefore, we believe that screening is also necessary in HBcAb-positive patients for early detection of HCC, especially in the elderly.


Assuntos
Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/virologia , Vírus da Hepatite B/isolamento & purificação , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/virologia , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Feminino , Hepatectomia , Hepatite B/complicações , Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Antígenos de Superfície da Hepatite B/sangue , Vírus da Hepatite B/imunologia , Humanos , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
18.
Cancer Imaging ; 19(1): 11, 2019 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-30813956

RESUMO

OBJECTIVE: To construct a prediction model based on peritumoral radiomics signatures from CT images and investigate its efficiency in predicting early recurrence (ER) of hepatocellular carcinoma (HCC) after curative treatment. MATERIALS AND METHODS: In total, 156 patients with primary HCC were randomly divided into the training cohort (109 patients) and the validation cohort (47 patients). From the pretreatment CT images, we extracted 3-phase two-dimensional images from the largest cross-sectional area of the tumor. A region of interest (ROI) was manually delineated around the lesion for tumoral radiomics (T-RO) feature extraction, and another ROI was outlined with an additional 2 cm peritumoral area for peritumoral radiomics (PT-RO) feature extraction. The least absolute shrinkage and selection operator (LASSO) logistic regression model was applied for feature selection and model construction. The T-RO and PT-RO models were constructed. In the validation cohort, the prediction efficiencies of the two models and peritumoral enhancement (PT-E) were evaluated qualitatively by receiver operating characteristic (ROC) curves, calibration curves and decision curves and quantitatively by area under the curve (AUC), the category-free net reclassification index (cfNRI) and integrated discrimination improvement values (IDI). RESULTS: By comparing AUC values, the prediction accuracy in the validation cohort was good for the PT-RO model (0.80 vs. 0.79, P = 0.47) but poor for the T-RO model (0.82 vs. 0.62, P < 0.01), which was significantly overfitted. In the validation cohort, the ROC curves, calibration curves and decision curves indicated that the PT-RO model had better calibration efficiency and provided greater clinical benefits. CfNRI indicated that the PT-RO model correctly reclassified 47% of ER patients and 32% of non-ER patients compared to the T-RO model (P < 0.01); additionally, the PT-RO model correctly reclassified 24% of ER patients and 41% of non-ER patients compared to PT-E (P = 0.02). IDI indicated that the PT-RO model could improve prediction accuracy by 0.22 (P < 0.01) compared to the T-RO model and by 0.20 (P = 0.01) compared to PT-E. CONCLUSION: The CT-based PT-RO model can effectively predict the ER of HCC and is more efficient than the T-RO model and the conventional imaging feature PT-E.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/diagnóstico por imagem , Técnicas de Ablação , Adulto , Idoso , Anatomia Transversal , Feminino , Hepatectomia , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X
19.
Abdom Radiol (NY) ; 44(7): 2409-2417, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31093728

RESUMO

PURPOSE: Intraductal papillary neoplasms of the bile duct (IPNBs) are a group of rare lesions with uncertain clinical findings and imaging features. We aim to investigate the clinicopathological features and imaging findings of IPNBs on contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT). METHODS: From February 2005 to March 2018, 30 patients with pathologically confirmed IPNBs were retrospectively identified in our hospital. Demographic, clinical, and pathological data, CEUS and CECT features and surgical strategies were analyzed. RESULTS: The most common clinical manifestations were abdominal pain (53.3%), jaundice (23.3%), and acute cholangitis (10.0%). Among all lesions, 5/30 (16.7%) lesions presented as dilated bile ducts only, while 13/30 (43.3%) lesions presented as dilated bile ducts with intraductal papillary masses, and 12/30 (40.0%) presented as solid masses with dilated bile ducts. For the 20 patients who underwent both CEUS and CECT, 18 lesions were hyperenhanced on CEUS, and 17 lesions were hyperenhanced on CECT in the arterial phase. In total, 16 and 18 lesions showed washout in the portal and late phases on CEUS, while the corresponding number of lesions that showed washout in the portal and late phases on CECT were 11 and 13. Twelve lesions (40.0%) showed atypical hyperplasia, while 16/30 (53.3%) lesions underwent malignant transformations. CONCLUSIONS: There are 3 major forms of IPNBs on grayscale ultrasound, including diffusely dilated bile ducts without visible mass; focal dilated bile duct with intraductal papillary masses; and solid mass surrounded by dilated bile ducts. The enhancement patterns of IPNBs on CEUS and on CECT were consistent. IPNB has a high malignant potential, and patients should be treated with surgical resection after the diagnosis is established.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/patologia , Meios de Contraste , Aumento da Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Adulto , Idoso , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Jpn J Radiol ; 37(10): 701-709, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31401722

RESUMO

OBJECTIVES: To evaluate quantitative three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) in the assessment of tumor angiogenesis using an orthotropic liver tumor model. METHODS: Nine New Zealand white rabbits with liver orthotropic VX2 tumors were established and imaged by two-dimensional (2D) and 3D DCE-US after SonoVue® bolus injections. The intraclass correlation coefficients of perfusion parameters, including peak intensity (PI), mean transit time, time to peak, and area under the curve, were calculated based on time-intensity curve. The percentage area of microvascular (PAMV) and the expression of vascular endothelial growth factor (VEGF) were both evaluated by immunohistochemical analysis and weighted by the tumor activity area ratio. Correlations between quantitative and histologic parameters were analyzed. RESULTS: The reproducibility of 3D DCE-US quantitative parameters was excellent (ICC 0.91-0.99); but only PI showed high reproducibility (ICC 0.97) in 2D. None of the parameters of quantitative 2D DCE-US were significantly correlated with weighted PAMV or VEGF. For 3D DCE-US, there was a positive correlation between PI and weighted PAMV (r = 0.74, P = 0.04) as well as VEGF (r = 0.79, P = 0.02). CONCLUSION: Quantitative parameters of 3D DCE-US show feasibility, higher reproducibility and accuracy for the assessment of tumor angiogenesis using an orthotropic liver tumor model compared with 2D DCE-US.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Modelos Animais de Doenças , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/patologia , Neovascularização Patológica/patologia , Coelhos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA