Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Comput Biol Med ; 168: 107715, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38007975

RESUMO

Sizing of flow diverters (FDs) is a challenging task in the treatment of intracranial aneurysms due to their foreshortening behavior. The purpose of this study is to evaluate the difference between the sizing results from the AneuGuide™ software and from conventional 2D measurement. Ninety-eight consecutive patients undergoing pipeline embolization device (PED) treatment between October 2018 and April 2023 in the First Medical Center of Chinese PLA General Hospital (Beijing, China) were retrospectively analyzed. For all cases, the optimal PED dimensions were both manually determined through 2D measurements on pre-treatment 3D-DSA and computed by AneuGuide™ software. The inter-rater reliability between the two sets of sizing results for each methodology was analyzed using intraclass correlation coefficient (ICC). The degree of agreement between manual sizing and software sizing were analyzed with the Bland-Altman plot and Pearson's test. Differences between two methodologies were analyzed with Wilcoxon signed rank test. Statistical significance was defined as p < 0.05. There was better inter-rater reliability between AneuGuide™ measurements both for diameter (ICC 0.92, 95%CI 0.88-0.95) and length (ICC 0.93, 95%CI 0.89-0.96). Bland-Altman plots showed a good agreement for diameter selection between two methodologies. However, the median length proposed by software group was significantly shorter (16 mm versus 20 mm, p < 0.001). No difference was found for median diameter (4.25 mm versus 4.25 mm). We demonstrated that the AneuGuide™ software provides highly reliable results of PED sizing compared with manual measurement, with a shorter stent length. AneuGuide™ may aid neurointerventionalists in selecting optimal dimensions for FD treatment.


Assuntos
Prótese Vascular , Software , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Stents
2.
J Neurointerv Surg ; 15(1): 57-62, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35039401

RESUMO

BACKGROUND: Stent sizing remains a challenging task for flow diverter implantation because of stent foreshortening. In this study, we aimed to quantify the change in length after implantation and assess the error in length prediction using AneuGuideTM software. METHODS: In a retrospective cohort of 101 patients with 102 aneurysms undergoing treatment with a pipeline embolization device (PED; Covidien, Irvine, California, USA), we used AneuGuideTM software to obtain measured lengths (ML) and calculated lengths (CL) after stent implantation. Stent elongation was defined as the ratio of ML-LL to the labeled length (LL). Simulation error was defined as the ratio of the absolute value of CL-ML to ML. The correlation and consistency between ML and LL and between ML and CL were analyzed using Pearson's correlation test and the Bland-Altman plot. Statistical significance was set at p<0.05. RESULTS: The mean elongation of ML was 32.6% (range 26.3-109.2%). Moderate consistency was observed between LL and ML (ρ=0.74, p<0.001). With the AneuGuideTM software, the mean simulation error was 6.6% (range 0.32-21.2%). Pearson's correlation test and the Bland-Altman plot showed a high correlation and consistency between ML and CL (ρ=0.96, p<0.001). CONCLUSION: Labeled length provides only a low reference value for predicting the actual length of the flow diverter after implantation. The high consistency between ML and CL obtained from AneuGuideTM software shows its great potential for the optimization of the flow diverter sizing process.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Prótese Vascular , Stents , Software , Resultado do Tratamento
3.
Interv Neuroradiol ; 29(4): 442-449, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35484808

RESUMO

BACKGROUNDS: Hemodynamics plays an important role in the natural history of the process of rupture and recurrence of intracranial aneurysms. This study aimed to investigate the role of hemodynamics for recurrence in a vertebral artery dissecting aneurysm (VADA). METHODS: A patient with a ruptured VADA firstly treated by low-profile visualized intraluminal support (LVIS)-assisted coiling, and was implanted with a Pipeline Embolization Device (PED) after aneurysm recurrence. Finite element analysis and computational fluid dynamics simulations were conducted in 6 serial imaging procedures, and the calculated hemodynamics was correlated with aneurysm recurrence. RESULTS: Wall shear stress (WSS) was not effectively suppressed, resulting in aneurysm recurrence with initial entry tear to occur above the protuberance after 7 months of LVIS stent-assisted coiling. With the implantation of PED, WSS, inflow stream and velocity at the aneurysm neck significantly decreased. During the 3-month follow-up after PED deployment, there was significant shrinkage of the sac and the blood flow in the sac was reduced considerably. The 27-month follow-up after PED deployment indicated the aneurysm was stable. CONCLUSIONS: The present case study suggests that insufficient suppression of high WSS and high inflow velocity at the neck of the parent artery, especially near the posterior inferior cerebellar artery, might be associated with aneurysm recurrence.


Assuntos
Aneurisma Roto , Dissecção Aórtica , Embolização Terapêutica , Aneurisma Intracraniano , Dissecação da Artéria Vertebral , Humanos , Artéria Vertebral/diagnóstico por imagem , Hidrodinâmica , Dissecação da Artéria Vertebral/terapia , Dissecação da Artéria Vertebral/cirurgia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Resultado do Tratamento , Embolização Terapêutica/métodos
4.
Bioeng Transl Med ; 7(2): e10291, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35600662

RESUMO

Nonuniform microstretching (NUMS) naturally occurs in real bone tissues in vivo, but its profound effects have not been identified yet. In order to explore the biological effects of NUMS and static stretch (uniform stretch [US]) on cells, a new "musical dish" device was developed. Musical signal was used to provide NUMS to cells. More stress fibers, arranging along the long axis of cells, were formed throughout the cells under NUMS, compared with US and untreated control group, although cell morphology did not show any alteration. Whole transcriptome sequencing revealed enhanced osteogenic differentiation of cells after NUMS treatment. Cells in the NUMS group showed a higher expression of bone-related genes, while genes related to stemness and other lineages were down-regulated. Our results give insights into the biological effects of NUMS and US on stem cell osteogenic differentiation, suggesting beneficial effects of micromechanical stimulus for osteogenesis. The newly developed device provides a basis for the development of NUMS derived rehabilitation technology to promote bone healing.

5.
Nanoscale ; 12(14): 7514-7521, 2020 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-32215396

RESUMO

Dielectric elastomers (DEs) are promising electroactive artificial muscles for use in soft machines. However, achieving anisotropy and sub-kV actuation voltage remains a great challenge for DE actuators. Herein, we report a facile method to fabricate ultrathin anisotropic DE films of an amorphous triblock copolymer poly(styrene-b-butyl acrylate-b-styrene) (SBAS) for soft actuators. The modulus of anisotropic SBAS in one direction can be modulated from 0.3 MPa to 10.5 MPa, and the modulus in the orthogonal direction remains the same as that of the pristine film (0.3 MPa). The anisotropy endows soft DE actuators with the directional-preferred response to an applied electric field and programmable multiple actuation morphs. These anisotropic SBAS films allowed us to fabricate compact soft robotics with high maneuverability, including soft grippers for object manipulation and crawling robots with reversible moving ability under an actuation voltage around 800 V.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA