Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Neuroimage ; 293: 120623, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38670442

RESUMO

High-order interactions are required across brain regions to accomplish specific cognitive functions. These functional interdependencies are reflected by synergistic information that can be obtained by combining the information from all the sources considered and redundant information (i.e., common information provided by all the sources). However, electroencephalogram (EEG) functional connectivity is limited to pairwise interactions thereby precluding the estimation of high-order interactions. In this multicentric study, we used measures of synergistic and redundant information to study in parallel the high-order interactions between five EEG electrodes during three non-ordinary states of consciousness (NSCs): Rajyoga meditation (RM), hypnosis, and auto-induced cognitive trance (AICT). We analyzed EEG data from 22 long-term Rajyoga meditators, nine volunteers undergoing hypnosis, and 21 practitioners of AICT. We here report the within-group changes in synergy and redundancy for each NSC in comparison with their respective baseline. During RM, synergy increased at the whole brain level in the delta and theta bands. Redundancy decreased in frontal, right central, and posterior electrodes in delta, and frontal, central, and posterior electrodes in beta1 and beta2 bands. During hypnosis, synergy decreased in mid-frontal, temporal, and mid-centro-parietal electrodes in the delta band. The decrease was also observed in the beta2 band in the left frontal and right parietal electrodes. During AICT, synergy decreased in delta and theta bands in left-frontal, right-frontocentral, and posterior electrodes. The decrease was also observed at the whole brain level in the alpha band. However, redundancy changes during hypnosis and AICT were not significant. The subjective reports of absorption and dissociation during hypnosis and AICT, as well as the mystical experience questionnaires during AICT, showed no correlation with the high-order measures. The proposed study is the first exploratory attempt to utilize the concepts of synergy and redundancy in NSCs. The differences in synergy and redundancy during different NSCs warrant further studies to relate the extracted measures with the phenomenology of the NSCs.


Assuntos
Estado de Consciência , Eletroencefalografia , Hipnose , Meditação , Humanos , Masculino , Feminino , Adulto , Estado de Consciência/fisiologia , Pessoa de Meia-Idade , Encéfalo/fisiologia , Adulto Jovem
2.
Eur Radiol ; 33(9): 6009-6019, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37017703

RESUMO

OBJECTIVES: Beyond total kidney and cyst volume (TCV), non-cystic tissue plays an important role in autosomal dominant polycystic kidney disease (ADPKD) progression. This study aims at presenting and preliminarily validating a diffusion MRI (DWI)-based TCV quantification method and providing evidence of DWI potential in characterising non-cystic tissue microstructure. METHODS: T2-weighted MRI and DWI scans (b = 0, 15, 50, 100, 200, 350, 500, 700, 1000; 3 directions) were acquired from 35 ADPKD patients with CKD stage 1 to 3a and 15 healthy volunteers on a 1.5 T scanner. ADPKD classification was performed using the Mayo model. DWI scans were processed by mono- and segmented bi-exponential models. TCV was quantified on T2-weighted MRI by the reference semi-automatic method and automatically computed by thresholding the pure diffusivity (D) histogram. The agreement between reference and DWI-based TCV values and the differences in DWI-based parameters between healthy and ADPKD tissue components were assessed. RESULTS: There was strong correlation between DWI-based and reference TCV (rho = 0.994, p < 0.001). Non-cystic ADPKD tissue had significantly higher D, and lower pseudo-diffusion and flowing fraction than healthy tissue (p < 0.001). Moreover, apparent diffusion coefficient and D values significantly differed by Mayo imaging class, both in the whole kidney (Wilcoxon p = 0.007 and p = 0.004) and non-cystic tissue (p = 0.024 and p = 0.007). CONCLUSIONS: DWI shows potential in ADPKD to quantify TCV and characterise non-cystic kidney tissue microstructure, indicating the presence of microcysts and peritubular interstitial fibrosis. DWI could complement existing biomarkers for non-invasively staging, monitoring, and predicting ADPKD progression and evaluating the impact of novel therapies, possibly targeting damaged non-cystic tissue besides cyst expansion. CLINICAL RELEVANCE STATEMENT: This study shows diffusion-weighted MRI (DWI) potential to quantify total cyst volume and characterise non-cystic kidney tissue microstructure in ADPKD. DWI could complement existing biomarkers for non-invasively staging, monitoring, and predicting ADPKD progression and evaluating the impact of novel therapies, possibly targeting damaged non-cystic tissue besides cyst expansion. KEY POINTS: • Diffusion magnetic resonance imaging shows potential to quantify total cyst volume in ADPKD. • Diffusion magnetic resonance imaging might allow to non-invasively characterise non-cystic kidney tissue microstructure. • Diffusion magnetic resonance imaging-based biomarkers significantly differ by Mayo imaging class, suggesting their possible prognostic value.


Assuntos
Cistos , Rim Policístico Autossômico Dominante , Humanos , Rim Policístico Autossômico Dominante/diagnóstico por imagem , Rim Policístico Autossômico Dominante/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Rim/diagnóstico por imagem , Rim/patologia , Biomarcadores , Cistos/diagnóstico por imagem , Cistos/patologia
3.
Conscious Cogn ; 116: 103590, 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-39491426

RESUMO

Meditation is a self-regulatory process practiced primarily to reduce stress, manage emotions and mental health. The objective of this work is to study the information exchange between electrodes within and across the hemispheres during meditation using functional connectivity (FC) measures. We investigate the changes in the coherence between EEG electrode pairs during the meditation with open eyes practiced by long-term Brahmakumaris Rajyoga meditators and during listening to music by controls as the comparable task. FC derived from coherency, pairwise phase consistency (PPC) is used to study the changes in intra and interhemispheric coherence. Integrating connectivity (IC) derived from node degree strength has also been analyzed. Meditators show increased PPC in higher theta and alpha bands both within and across hemispheres. However, the control subjects with no knowledge of meditation show no change in theta band during the music session. Further, during baseline conditions, higher interhemispheric anterior to posterior IC is found in meditators in higher beta and slow gamma bands than controls. Distinct patterns of changes are observed with the PPC and IC measures in different frequency bands during meditation in the meditators and music-listening session in the control subjects indicating varied information processing between the right and left hemispheres. Increased IC is found between the frontal electrodes implying increased self-awareness in meditators. The PPC between the occipital electrodes in meditators is less than the controls in baseline condition indicating a possible modified visual information processing in Rajyoga meditators due to the long-term practice of meditation with open eyes. Overall, the changes in PPC and associated IC indicate increased functional integration during meditation supporting the hypothesis of communication through coherence and cortical integration theory during the non-ordinary state of consciousness induced by meditation.

4.
MAGMA ; 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37971557

RESUMO

OBJECTIVES: Renal blood flow (RBF) is controlled by a number of physiological factors that can contribute to the variability of its measurement. The purpose of this review is to assess the changes in RBF in response to a wide range of physiological confounders and derive practical recommendations on patient preparation and interpretation of RBF measurements with MRI. METHODS: A comprehensive search was conducted to include articles reporting on physiological variations of renal perfusion, blood and/or plasma flow in healthy humans. RESULTS: A total of 24 potential confounders were identified from the literature search and categorized into non-modifiable and modifiable factors. The non-modifiable factors include variables related to the demographics of a population (e.g. age, sex, and race) which cannot be manipulated but should be considered when interpreting RBF values between subjects. The modifiable factors include different activities (e.g. food/fluid intake, exercise training and medication use) that can be standardized in the study design. For each of the modifiable factors, evidence-based recommendations are provided to control for them in an RBF-measurement. CONCLUSION: Future studies aiming to measure RBF are encouraged to follow a rigorous study design, that takes into account these recommendations for controlling the factors that can influence RBF results.

5.
Physiol Mol Biol Plants ; 29(10): 1543-1561, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38076761

RESUMO

Canonical heterotrimeric G-proteins (G-proteins) are comprised of Gα, Gß, and Gγ subunits. G-proteins regulate multiple crucial plant growth and development processes, incorporating environmental responses. Besides Gα, Gß and Gγ, the discovery of atypical Gα subunits termed as extra-large G-proteins or extra-large GTP-binding proteins (XLGs) makes G-protein signaling unique in plants. The C-terminus of XLG shares similarities with the canonical Gα subunits; the N-terminus harbors a nuclear localization signal (NLS) and is rich in cysteine. The earlier explorations suggest XLG's role in flowering, the development of embryos and seedlings, root morphogenesis, stamen development, cytokinin-induced development, stomatal opening and regulation of rice grain filling. The XLGs are also known to initiate signaling cascades that prime plants against a variety of abiotic and biotic stresses. They are also engaged in controlling several agronomic parameters such as rice panicle length, grain filling, grain size, and biomass, highlighting their potential contribution to crop improvement. The present review explores the remarkable properties of non-canonical Gα subunits (XLGs) and reflects on the various developmental, abiotic and biotic stress signaling pathways controlled by them. Moreover, the bottleneck dilemma of how a tiny handful of XLGs control a multiplicity of stress-responsive activities is partially resolved in this review by addressing the interaction of XLGs with different interacting proteins. XLG proteins presented in this review can be exploited to gain access to highly productive and stress-tolerant plants.

6.
J Magn Reson Imaging ; 55(4): 1241-1250, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34397124

RESUMO

BACKGROUND: Renal blood flow (RBF) can be measured with dynamic contrast enhanced-MRI (DCE-MRI) and arterial spin labeling (ASL). Unfortunately, individual estimates from both methods vary and reference-standard methods are not available. A potential solution is to include a third, arbitrating MRI method in the comparison. PURPOSE: To compare RBF estimates between ASL, DCE, and phase contrast (PC)-MRI. STUDY TYPE: Prospective. POPULATION: Twenty-five patients with type-2 diabetes (36% female) and five healthy volunteers (HV, 80% female). FIELD STRENGTH/SEQUENCES: A 3 T; gradient-echo 2D-DCE, pseudo-continuous ASL (pCASL) and cine 2D-PC. ASSESSMENT: ASL, DCE, and PC were acquired once in all patients. ASL and PC were acquired four times in each HV. RBF was estimated and split-RBF was derived as (right kidney RBF)/total RBF. Repeatability error (RE) was calculated for each HV, RE = 1.96 × SD, where SD is the standard deviation of repeat scans. STATISTICAL TESTS: Paired t-tests and one-way analysis of variance (ANOVA) were used for statistical analysis. The 95% confidence interval (CI) for difference between ASL/PC and DCE/PC was assessed using two-sample F-test for variances. Statistical significance level was P < 0.05. Influential outliers were assessed with Cook's distance (Di > 1) and results with outliers removed were presented. RESULTS: In patients, the mean RBF (mL/min/1.73m2 ) was 618 ± 62 (PC), 526 ± 91 (ASL), and 569 ± 110 (DCE). Differences between measurements were not significant (P = 0.28). Intrasubject agreement was poor for RBF with limits-of-agreement (mL/min/1.73m2 ) [-687, 772] DCE-ASL, [-482, 580] PC-DCE, and [-277, 460] PC-ASL. The difference PC-ASL was significantly smaller than PC-DCE, but this was driven by a single-DCE outlier (P = 0.31, after removing outlier). The difference in split-RBF was comparatively small. In HVs, mean RE (±95% CI; mL/min/1.73 m2 ) was significantly smaller for PC (79 ± 41) than for ASL (241 ± 85). CONCLUSIONS: ASL, DCE, and PC RBF show poor agreement in individual subjects but agree well on average. Triangulation with PC suggests that the accuracy of ASL and DCE is comparable. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Meios de Contraste , Circulação Renal , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Circulação Renal/fisiologia , Reprodutibilidade dos Testes , Marcadores de Spin
7.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33140551

RESUMO

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Rim , Imageamento por Ressonância Magnética , Consenso , Técnica Delphi , Humanos , Estudos Multicêntricos como Assunto , Circulação Renal
8.
MAGMA ; 33(1): 131-140, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31628564

RESUMO

PURPOSE: The potential of renal MRI biomarkers has been increasingly recognised, but clinical translation requires more standardisation. The PARENCHIMA consensus project aims to develop and apply a process for generating technical recommendations on renal MRI. METHODS: A task force was formed in July 2018 focused on five methods. A draft process for attaining consensus was distributed publicly for consultation and finalised at an open meeting (Prague, October 2018). Four expert panels completed surveys between October 2018 and March 2019, discussed results and refined the surveys at a face-to-face meeting (Aarhus, March 2019) and completed a second round (May 2019). RESULTS: A seven-stage process was defined: (1) formation of expert panels; (2) definition of the context of use; (3) literature review; (4) collection and comparison of MRI protocols; (5) consensus generation by an approximate Delphi method; (6) reporting of results in vendor-neutral and vendor-specific terms; (7) ongoing review and updating. Application of the process resulted in 166 consensus statements. CONCLUSION: The process generated meaningful technical recommendations across very different MRI methods, while allowing for improvement and refinement as open issues are resolved. The results are likely to be widely supported by the renal MRI community and thereby promote more harmonisation.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Nefrologia/normas , Pesquisa Translacional Biomédica/normas , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Europa (Continente) , Prova Pericial , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/tendências , Nefrologia/tendências , Padrões de Referência , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências , Estados Unidos
9.
MAGMA ; 33(1): 177-195, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31676990

RESUMO

OBJECTIVES: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. MATERIALS AND METHODS: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. RESULTS: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65-74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. DISCUSSION: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.


Assuntos
Biomarcadores/metabolismo , Imagem de Difusão por Ressonância Magnética , Rim/diagnóstico por imagem , Pesquisa Translacional Biomédica , Algoritmos , Consenso , Técnica Delphi , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Rim/metabolismo , Modelos Estatísticos , Movimento (Física) , Reprodutibilidade dos Testes , Inquéritos e Questionários
11.
MAGMA ; 33(1): 199-215, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31768797

RESUMO

Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Animais , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Humanos , Rim/metabolismo , Imageamento por Ressonância Magnética/normas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências
12.
MAGMA ; 33(1): 141-161, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833014

RESUMO

OBJECTIVES: This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS: An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS: Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION: This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.


Assuntos
Circulação Cerebrovascular , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Marcadores de Spin , Pesquisa Translacional Biomédica/tendências , Algoritmos , Consenso , Técnica Delphi , Imagem Ecoplanar , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Transplante de Rim , Angiografia por Ressonância Magnética , Estudos Multicêntricos como Assunto , Perfusão , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-Ruído
13.
BMC Nephrol ; 21(1): 242, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32600374

RESUMO

BACKGROUND: Diabetic kidney disease (DKD) remains one of the leading causes of premature death in diabetes. DKD is classified on albuminuria and reduced kidney function (estimated glomerular filtration rate (eGFR)) but these have modest value for predicting future renal status. There is an unmet need for biomarkers that can be used in clinical settings which also improve prediction of renal decline on top of routinely available data, particularly in the early stages. The iBEAt study of the BEAt-DKD project aims to determine whether renal imaging biomarkers (magnetic resonance imaging (MRI) and ultrasound (US)) provide insight into the pathogenesis and heterogeneity of DKD (primary aim) and whether they have potential as prognostic biomarkers in DKD (secondary aim). METHODS: iBEAt is a prospective multi-centre observational cohort study recruiting 500 patients with type 2 diabetes (T2D) and eGFR ≥30 ml/min/1.73m2. At baseline, blood and urine will be collected, clinical examinations will be performed, and medical history will be obtained. These assessments will be repeated annually for 3 years. At baseline each participant will also undergo quantitative renal MRI and US with central processing of MRI images. Biological samples will be stored in a central laboratory for biomarker and validation studies, and data in a central data depository. Data analysis will explore the potential associations between imaging biomarkers and renal function, and whether the imaging biomarkers improve the prediction of DKD progression. Ancillary substudies will: (1) validate imaging biomarkers against renal histopathology; (2) validate MRI based renal blood flow measurements against H2O15 positron-emission tomography (PET); (3) validate methods for (semi-)automated processing of renal MRI; (4) examine longitudinal changes in imaging biomarkers; (5) examine whether glycocalyx and microvascular measures are associated with imaging biomarkers and eGFR decline; (6) explore whether the findings in T2D can be extrapolated to type 1 diabetes. DISCUSSION: iBEAt is the largest DKD imaging study to date and will provide valuable insights into the progression and heterogeneity of DKD. The results may contribute to a more personalised approach to DKD management in patients with T2D. TRIAL REGISTRATION: Clinicaltrials.gov ( NCT03716401 ).


Assuntos
Diabetes Mellitus Tipo 2/metabolismo , Nefropatias Diabéticas/diagnóstico por imagem , Rim/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 2/complicações , Nefropatias Diabéticas/etiologia , Nefropatias Diabéticas/patologia , Progressão da Doença , Humanos , Rim/irrigação sanguínea , Rim/patologia , Imageamento por Ressonância Magnética , Estudos Observacionais como Assunto , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Prognóstico , Estudos Prospectivos , Circulação Renal , Insuficiência Renal Crônica/etiologia , Insuficiência Renal Crônica/patologia , Ultrassonografia
14.
J Cell Physiol ; 234(3): 2067-2082, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30171697

RESUMO

A large body of evidence indicates that chronic obstructive pulmonary disorder (COPD) is accompanied by oxidative stress and inflammatory and genetic pathways. Epidemiological studies indicate that COPD is a major cause of mortality and morbidity in the world. Recent research development in COPD focuses on accelerated aging and various oxidative stress biomarkers. It involves the clinical manifestation of the disease process and may also contain biochemical, immunological, physiological, morphological, and genetic aspects that add to the progressiveness of the disease. Herein, we summarize findings that highlight the role of dimensions of COPD in the investigation of oxidative stress, inflammatory responses, genetic and epigenetic studies, and pharmacological and dietary antioxidant intervention.


Assuntos
Antioxidantes/metabolismo , Epigênese Genética , Estresse Oxidativo/genética , Doença Pulmonar Obstrutiva Crônica/genética , Biomarcadores/metabolismo , Humanos , Doença Pulmonar Obstrutiva Crônica/metabolismo , Doença Pulmonar Obstrutiva Crônica/patologia
16.
Nephrol Dial Transplant ; 33(suppl_2): ii41-ii50, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137583

RESUMO

This systematic review, initiated by the European Cooperation in Science and Technology Action Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease (PARENCHIMA), focuses on potential clinical applications of magnetic resonance imaging in renal non-tumour disease using magnetic resonance relaxometry (MRR), specifically, the measurement of the independent quantitative magnetic resonance relaxation times T1 and T2 at 1.5 and 3Tesla (T), respectively. Healthy subjects show a distinguishable cortico-medullary differentiation (CMD) in T1 and a slight CMD in T2. Increased cortical T1 values, that is, reduced T1 CMD, were reported in acute allograft rejection (AAR) and diminished T1 CMD in chronic allograft rejection. However, ambiguous findings were reported and AAR could not be sufficiently differentiated from acute tubular necrosis and cyclosporine nephrotoxicity. Despite this, one recent quantitative study showed in renal transplants a direct correlation between fibrosis and T1 CMD. Additionally, various renal diseases, including renal transplants, showed a moderate to strong correlation between T1 CMD and renal function. Recent T2 studies observed increased values in renal transplants compared with healthy subjects and in early-stage autosomal dominant polycystic kidney disease (ADPKD), which could improve diagnosis and progression assessment compared with total kidney volume alone in early-stage ADPKD. Renal MRR is suggested to be sensitive to renal perfusion, ischaemia/oxygenation, oedema, fibrosis, hydration and comorbidities, which reduce specificity. Due to the lack of standardization in patient preparation, acquisition protocols and adequate patient selection, no widely accepted reference values are currently available. Therefore this review encourages efforts to optimize and standardize (multi-parametric) protocols to increase specificity and to tap the full potential of renal MRR in future research.


Assuntos
Biomarcadores/análise , Nefropatias/patologia , Rim/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Guias de Prática Clínica como Assunto/normas , Progressão da Doença , Humanos
17.
J Clin Med ; 12(15)2023 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-37568543

RESUMO

Thanks to technical advances in the field of medical imaging, it is now possible to study key features of renal anatomy and physiology, but so far poorly explored due to the inherent difficulties in studying both the metabolism and vasculature of the human kidney. In this narrative review, we provide an overview of recent research findings on renal perfusion, oxygenation, and substrate uptake. Most studies evaluating renal perfusion with positron emission tomography (PET) have been performed in healthy controls, and specific target populations like obese individuals or patients with renovascular disease and chronic kidney disease (CKD) have rarely been assessed. Functional magnetic resonance (fMRI) has also been used to study renal perfusion in CKD patients, and recent studies have addressed the kidney hemodynamic effects of therapeutic agents such as glucagon-like receptor agonists (GLP-1RA) and sodium-glucose co-transporter 2 inhibitors (SGLT2-i) in an attempt to characterise the mechanisms leading to their nephroprotective effects. The few available studies on renal substrate uptake are discussed. In the near future, these imaging modalities will hopefully become widely available with researchers more acquainted with them, gaining insights into the complex renal pathophysiology in acute and chronic diseases.

18.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 459-462, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891332

RESUMO

Phonemes are classified into different categories based on the place and manner of articulation. We investigate the differences between the neural correlates of imagined nasal and bilabial consonants (distinct phonological categories). Mean phase coherence is used as a metric for measuring the phase synchronisation between pairs of electrodes in six cortical regions (auditory, motor, prefrontal, sensorimotor, so-matosensory and premotor) during the imagery of nasal and bilabial consonants. Statistically significant difference at 95% confidence interval is observed in beta and lower-gamma bands in various cortical regions. Our observations are inline with the directions into velocities of articulators and dual stream prediction models and support the hypothesis that phonological categories not only exist in articulated speech but can also be distinguished from the EEG of imagined speech.


Assuntos
Percepção da Fala , Fala , Eletroencefalografia
19.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 787-790, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891408

RESUMO

Meditation practices are considered mental training and have increasingly received attention from the scientific community due to their potential psychological and physical health benefits. We compared the EEG data recorded from long-term rajayoga practitioners during different meditative and non-meditative periods. Minimum variance modified fuzzy entropy (MVMFE) is computed for each EEG band for all channels of a given lobe. The means across all the channel entropy values were obtained and compared during meditative and non-meditative states. Meditators showed higher frontal entropy in the lower gamma band (25-45Hz) during the meditative states. Independent component analysis was applied to ensure that muscle or eye artifacts did not contribute to the gamma activity. Our results extend previous findings on the changes in entropy observed in long-term meditators during rajayoga practice. Gamma band in EEG is implicated in cognitive processes requiring high-level processing such as attention, learning, memory control, and retrieval. Gamma activity is also suggested as a potential biomarker for therapeutic progress in patients with clinical depression. Based on our findings, there is an excellent possibility to utilize the practice of meditation as a training tool to strengthen the neural circuits, where age-related degeneration is making its pathological impact.


Assuntos
Meditação , Artefatos , Entropia , Lobo Frontal , Humanos
20.
Int J Yoga ; 11(1): 30-36, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29343928

RESUMO

BACKGROUND: Rajyoga meditation is taught by Prajapita Brahmakumaris World Spiritual University (Brahmakumaris) and has been followed by more than one million followers across the globe. However, rare studies were conducted on physiological aspects of rajyoga meditation using electroencephalography (EEG). Band power and cortical asymmetry were not studied with Rajyoga meditators. AIMS: This study aims to investigate the effect of regular meditation practice on EEG brain dynamics in low-frequency bands of long-term Rajyoga meditators. SETTINGS AND DESIGN: Subjects were matched for age in both groups. Lower frequency EEG bands were analyzed in resting and during meditation. MATERIALS AND METHODS: Twenty-one male long-term meditators (LTMs) and same number of controls were selected to participate in study as par inclusion criteria. Semi high-density EEG was recorded before and during meditation in LTM group and resting in control group. The main outcome of the study was spectral power of alpha and theta bands and cortical (hemispherical) asymmetry calculated using band power. STATISTICAL ANALYSIS: One-way ANOVA was performed to find the significant difference between EEG spectral properties of groups. Pearson's Chi-square test was used to find difference among demographics data. RESULTS: Results reveal high-band power in alpha and theta spectra in meditators. Cortical asymmetry calculated through EEG power was also found to be high in frontal as well as parietal channels. However, no correlation was seen between the experience of meditation (years, hours) practice and EEG indices. CONCLUSION: Overall findings indicate contribution of smaller frequencies (alpha and theta) while maintaining meditative experience. This suggests a positive impact of meditation on frontal and parietal areas of brain, involved in the processes of regulation of selective and sustained attention as well as provide evidence about their involvement in emotion and cognitive processing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA