RESUMO
AIM: Synthetic MRI (SyMRI) works on the MDME sequence, which acquires the relaxation properties of the brain and helps to measure the accurate tissue properties in 6 minutes. The aim of this study was to evaluate the synthetic MRI (SyMRI)-generated myelin (MyC) to white matter (WM) ratio, the WM fraction (WMF), MyC partial maps performing normative brain volumetry to investigate MyC loss in multiple sclerosis (MS) patients with white-matter hyperintensites (WMHs) and non-MS patients with WMHs in a clinical setting. MATERIALS and METHODS: Synthetic MRI images were acquired from 15 patients with MS, and from 15 non-MS patients on a 3T MRI scanner (Discovery MR750w; GE Healthcare; Milwaukee, USA) using MAGiC, a customized version of SyntheticMR's SyMRI® IMAGE software marketed by GE Healthcare under a license agreement. Fast multi-delay multi-echo acquisition was performed with a 2D axial pulse sequence with different combinations of echo time (TEs) and saturation delay times. The total image acquisition time was 6 minutes. SyMRI image analysis was done using SyMRI software (SyMRI Version: 11.3.6; Synthetic MR, Linköping, Sweden). SyMRI data were used to generate the MyC partial maps and WMFs to quantify the signal intensities of test group and control group, andcontrol group , and their mean values were recorded. All patients also underwent conventional diffusion-weighted imaging, i.e., T1w and T2w imaging. RESULTS: The results showed that the WMF was significantly lower in the test group than in the control group (38.8% vs 33.2%, p < 0.001). The Mann-Whitney U nonparametric t-test revealed a significant difference in the mean myelin volume between the test group and the control group (158.66 ± 32.31 vs. 138.29 ± 29.28, p = 0.044). Also, there were no significant differences in the gray matter fraction and intracranial volume between the test group and the control group. CONCLUSIONS: We observed MyC loss in test group using quantitative SyMRI. Thus, myelin loss in MS patients can be quantitatively evaluated using SyMRI.
RESUMO
Image-based simulation, the use of 3D images to calculate physical quantities, relies on image segmentation for geometry creation. However, this process introduces image segmentation uncertainty because different segmentation tools (both manual and machine-learning-based) will each produce a unique and valid segmentation. First, we demonstrate that these variations propagate into the physics simulations, compromising the resulting physics quantities. Second, we propose a general framework for rapidly quantifying segmentation uncertainty. Through the creation and sampling of segmentation uncertainty probability maps, we systematically and objectively create uncertainty distributions of the physics quantities. We show that physics quantity uncertainty distributions can follow a Normal distribution, but, in more complicated physics simulations, the resulting uncertainty distribution can be surprisingly nontrivial. We establish that bounding segmentation uncertainty can fail in these nontrivial situations. While our work does not eliminate segmentation uncertainty, it improves simulation credibility by making visible the previously unrecognized segmentation uncertainty plaguing image-based simulation.