RESUMO
People living with diabetes have many medical devices available to assist with disease management. A critical aspect that must be considered is how systems for continuous glucose monitoring and insulin pumps communicate with each other and how the data generated by these devices can be downloaded, integrated, presented and used. Not only is interoperability associated with practical challenges, but also devices must adhere to all aspects of regulatory and legal frameworks. Key issues around interoperability in terms of data ownership, privacy and the limitations of interoperability include where the responsibility/liability for device and data interoperability lies and the need for standard data-sharing protocols to allow the seamless integration of data from different sources. There is a need for standardised protocols for the open and transparent handling of data and secure integration of data into electronic health records. Here, we discuss the current status of interoperability in medical devices and data used in diabetes therapy, as well as regulatory and legal issues surrounding both device and data interoperability, focusing on Europe (including the UK) and the USA. We also discuss a potential future landscape in which a clear and transparent framework for interoperability and data handling also fulfils the needs of people living with diabetes and healthcare professionals.
Assuntos
Automonitorização da Glicemia , Diabetes Mellitus , Humanos , Glicemia , Diabetes Mellitus/tratamento farmacológico , Registros Eletrônicos de Saúde , Reino UnidoRESUMO
Diabetes is unique among chronic diseases because clinical outcomes are intimately tied to how the person living with diabetes reacts to and implements treatment recommendations. It is further characterised by widespread social stigma, judgement and paternalism. This physical, social and psychological burden collectively influences self-management behaviours. It is widely recognised that the individual's perspective about the impact of trying to manage the disease and the burden that self-management confers must be addressed to achieve optimal health outcomes. Standardised, rigorous assessment of mental and behavioural health status, in interaction with physical health outcomes is crucial to aid understanding of person-reported outcomes (PROs). Whilst tempting to conceptualise PROs as an issue of perceived quality of life (QoL), in fact health-related QoL is multi-dimensional and covers indicators of physical or functional health status, psychological and social well-being. This complexity is illuminated by the large number of person reported outcome measures (PROMs) that have been developed across multiple psychosocial domains. Often measures are used inappropriately or because they have been used in the scientific literature rather than based on methodological or outcome assessment rigour. Given the broad nature of psychosocial functioning/mental health, it is important to broadly define PROs that are evaluated in the context of therapeutic interventions, real-life and observational studies. This report summarises the central themes and lessons derived in the assessment and use of PROMs amongst adults with diabetes. Effective assessment of PROMs routinely in clinical research is crucial to understanding the true impact of any intervention. Selecting appropriate measures, relevant to the specific factors of PROs important in the research study will provide valuable data alongside physical health data.
Assuntos
Diabetes Mellitus , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Humanos , Diabetes Mellitus/terapia , Diabetes Mellitus/psicologia , Adulto , Consenso , Nível de SaúdeRESUMO
AIM: Automated insulin delivery (AID) systems have demonstrated improved glycaemic outcomes in people with type 1 diabetes (T1D), yet limited data exist on these systems in very young children and their impact on caregivers. We evaluated psychosocial outcomes following use of the tubeless Omnipod® 5 AID System in caregivers of very young children. MATERIALS AND METHODS: This 3-month single-arm, multicentre, pivotal clinical trial enrolled 80 children aged 2.0-5.9 years with T1D to use the Omnipod 5 AID System. Caregivers completed questionnaires assessing psychosocial outcomes-diabetes distress (Problem Areas in Diabetes), hypoglycaemia confidence (Hypoglycemia Confidence Scale), well-being (World Health Organization 5 Well-Being Index), sleep quality (Pittsburgh Sleep Quality Index), insulin delivery satisfaction (Insulin Delivery Satisfaction Survey) and system usability (System Usability Scale) at baseline with standard therapy and after 3 months of AID use. RESULTS: Following 3 months of Omnipod 5 use, caregivers experienced significant improvements across all measures, including diabetes-related psychosocial outcomes (Problem Areas in Diabetes; p < 0.0001, Hypoglycemia Confidence Scale; p < 0.01), well-being (World Health Organization 5 Well-Being Index; p < 0.0001) and perceived system usability (System Usability Scale; p < 0.0001). Significant improvements were seen in the Pittsburgh Sleep Quality Index total score and the overall sleep quality, sleep duration and efficiency subscales (all p < 0.05). Insulin Delivery Satisfaction Survey scores improved on all subscales (greater satisfaction, reduced burden and reduced inconvenience; all p < 0.0001). CONCLUSIONS: Caregivers face unique challenges when managing T1D in very young children. While glycaemic metrics have unquestioned importance, these results evaluating psychosocial outcomes reveal additional meaningful benefits and suggest that the Omnipod 5 AID System alleviates some of the burdens caregivers face with diabetes management.
RESUMO
A technological solution for the management of diabetes in people who require intensive insulin therapy has been sought for decades. The last 10 years have seen substantial growth in devices that can be integrated into clinical care. Driven by the availability of reliable systems for continuous glucose monitoring, we have entered an era in which insulin delivery through insulin pumps can be modulated based on sensor glucose data. Over the past few years, regulatory approval of the first automated insulin delivery (AID) systems has been granted, and these systems have been adopted into clinical care. Additionally, a community of people living with type 1 diabetes has created its own systems using a do-it-yourself approach by using products commercialised for independent use. With several AID systems in development, some of which are anticipated to be granted regulatory approval in the near future, the joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association has created this consensus report. We provide a review of the current landscape of AID systems, with a particular focus on their safety. We conclude with a series of recommended targeted actions. This is the fourth in a series of reports issued by this working group. The working group was jointly commissioned by the executives of both organisations to write the first statement on insulin pumps, which was published in 2015. The original authoring group was comprised by three nominated members of the American Diabetes Association and three nominated members of the European Association for the Study of Diabetes. Additional authors have been added to the group to increase diversity and range of expertise. Each organisation has provided a similar internal review process for each manuscript prior to submission for editorial review by the two journals. Harmonisation of editorial and substantial modifications has occurred at both levels. The members of the group have selected the subject of each statement and submitted the selection to both organisations for confirmation.
Assuntos
Diabetes Mellitus , Insulina , Humanos , Estados Unidos , Insulina/uso terapêutico , Automonitorização da Glicemia , Glicemia , Diabetes Mellitus/tratamento farmacológico , TecnologiaRESUMO
BACKGROUND: In youth with type 1 diabetes (T1D), high haemoglobin A1c (HbA1c) levels are associated with an increased risk for diabetic ketoacidosis (DKA). AIMS: This study examined whether daily school-supervised basal insulin injections were feasible and if they reduced the risk of morning ketosis in children and adolescents with high HbA1c levels. We hypothesized that supervised glargine and degludec would reduce the risk of ketosis and that the prolonged action of degludec would protect from ketosis after consecutive days of unsupervised injections. MATERIALS & METHODS: After a 2-4-week run-in, youth (10-18 years, HbA1c ≥ 8.5%) managing T1D with injections were randomized to school-supervised administration of degludec or glargine for 4 months. School nurses observed daily blood ß-hydroxybutyrate (BHB) and glucose checks. During COVID closures, the research team supervised procedures remotely. RESULTS: Data from 28 youth (age 14.3 ± 2.3 years, HbA1c 11.4 ± 1.9%, 64% F) were analysed. School-supervised injections of both basal insulins for 1-4 days progressively lowered the percent of participants with elevated BHB. The percent of participants with elevated BHB (≥0.6 mmol/L) after 2 days of unsupervised basal insulin doses at home was greater in the glargine than degludec group but had a high p-value (17.2% vs. 9.0%, p = 0.3). HbA1c was unchanged in both groups. DISCUSSION: In youth with T1D at high risk for DKA, daily supervised long-acting insulin administration decreased the probability of elevated ketone levels on subsequent school days, regardless of basal insulin type. A larger sample size may have demonstrated that the longer action profile of degludec would offer additional protection from ketosis during days of not attending school. CONCLUSION: Engaging school-based caregivers in management of youth with T1D on injected insulin may decrease clinically significant ketosis and minimize acute complications of diabetes.
Assuntos
COVID-19 , Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Neoplasias , Criança , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Glargina , Hemoglobinas Glicadas , Hipoglicemiantes , Projetos Piloto , Insulina/uso terapêutico , Glicemia/análise , Cetoacidose Diabética/epidemiologia , Cetoacidose Diabética/prevenção & controle , Cetoacidose Diabética/induzido quimicamente , Neoplasias/induzido quimicamenteRESUMO
Importance: Near normalization of glucose levels instituted immediately after diagnosis of type 1 diabetes has been postulated to preserve pancreatic beta cell function by reducing glucotoxicity. Previous studies have been hampered by an inability to achieve tight glycemic goals. Objective: To determine the effectiveness of intensive diabetes management to achieve near normalization of glucose levels on preservation of pancreatic beta cell function in youth with newly diagnosed type 1 diabetes. Design, Setting, and Participants: This randomized, double-blind, clinical trial was conducted at 6 centers in the US (randomizations from July 20, 2020, to October 13, 2021; follow-up completed September 15, 2022) and included youths with newly diagnosed type 1 diabetes aged 7 to 17 years. Interventions: Random assignment to intensive diabetes management, which included use of an automated insulin delivery system (n = 61), or standard care, which included use of a continuous glucose monitor (n = 52), as part of a factorial design in which participants weighing 30 kg or more also were assigned to receive either oral verapamil or placebo. Main Outcomes and Measures: The primary outcome was mixed-meal tolerance test-stimulated C-peptide area under the curve (a measure of pancreatic beta cell function) 52 weeks from diagnosis. Results: Among 113 participants (mean [SD] age, 11.8 [2.8] years; 49 females [43%]; mean [SD] time from diagnosis to randomization, 24 [5] days), 108 (96%) completed the trial. The mean C-peptide area under the curve decreased from 0.57 pmol/mL at baseline to 0.45 pmol/mL at 52 weeks in the intensive management group, and from 0.60 to 0.50 pmol/mL in the standard care group (treatment group difference, -0.01 [95% CI, -0.11 to 0.10]; P = .89). The mean time in the target range of 70 to 180 mg/dL, measured with continuous glucose monitoring, at 52 weeks was 78% in the intensive management group vs 64% in the standard care group (adjusted difference, 16% [95% CI, 10% to 22%]). One severe hypoglycemia event and 1 diabetic ketoacidosis event occurred in each group. Conclusions and Relevance: In youths with newly diagnosed type 1 diabetes, intensive diabetes management, which included automated insulin delivery, achieved excellent glucose control but did not affect the decline in pancreatic C-peptide secretion at 52 weeks. Trial Registration: ClinicalTrials.gov Identifier: NCT04233034.
Assuntos
Diabetes Mellitus Tipo 1 , Células Secretoras de Insulina , Feminino , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/administração & dosagem , Glicemia/efeitos dos fármacos , Células Secretoras de Insulina/efeitos dos fármacos , Peptídeo C/farmacologia , Peptídeo C/uso terapêutico , Método Duplo-Cego , Controle Glicêmico , Automonitorização da Glicemia , Hemoglobinas Glicadas , Insulina/efeitos adversos , Insulina/administração & dosagemRESUMO
Importance: In preclinical studies, thioredoxin-interacting protein overexpression induces pancreatic beta cell apoptosis and is involved in glucotoxicity-induced beta cell death. Calcium channel blockers reduce these effects and may be beneficial to beta cell preservation in type 1 diabetes. Objective: To determine the effect of verapamil on pancreatic beta cell function in children and adolescents with newly diagnosed type 1 diabetes. Design, Setting, and Participants: This double-blind, randomized clinical trial including children and adolescents aged 7 to 17 years with newly diagnosed type 1 diabetes who weighed 30 kg or greater was conducted at 6 centers in the US (randomized participants between July 20, 2020, and October 13, 2021) and follow-up was completed on September 15, 2022. Interventions: Participants were randomly assigned 1:1 to once-daily oral verapamil (n = 47) or placebo (n = 41) as part of a factorial design in which participants also were assigned to receive either intensive diabetes management or standard diabetes care. Main Outcomes and Measures: The primary outcome was area under the curve values for C-peptide level (a measure of pancreatic beta cell function) stimulated by a mixed-meal tolerance test at 52 weeks from diagnosis of type 1 diabetes. Results: Among 88 participants (mean age, 12.7 [SD, 2.4] years; 36 were female [41%]; and the mean time from diagnosis to randomization was 24 [SD, 4] days), 83 (94%) completed the trial. In the verapamil group, the mean C-peptide area under the curve was 0.66 pmol/mL at baseline and 0.65 pmol/mL at 52 weeks compared with 0.60 pmol/mL at baseline and 0.44 pmol/mL at 52 weeks in the placebo group (adjusted between-group difference, 0.14 pmol/mL [95% CI, 0.01 to 0.27 pmol/mL]; P = .04). This equates to a 30% higher C-peptide level at 52 weeks with verapamil. The percentage of participants with a 52-week peak C-peptide level of 0.2 pmol/mL or greater was 95% (41 of 43 participants) in the verapamil group vs 71% (27 of 38 participants) in the placebo group. At 52 weeks, hemoglobin A1c was 6.6% in the verapamil group vs 6.9% in the placebo group (adjusted between-group difference, -0.3% [95% CI, -1.0% to 0.4%]). Eight participants (17%) in the verapamil group and 8 participants (20%) in the placebo group had a nonserious adverse event considered to be related to treatment. Conclusions and Relevance: In children and adolescents with newly diagnosed type 1 diabetes, verapamil partially preserved stimulated C-peptide secretion at 52 weeks from diagnosis compared with placebo. Further studies are needed to determine the longitudinal durability of C-peptide improvement and the optimal length of therapy. Trial Registration: ClinicalTrials.gov Identifier: NCT04233034.
Assuntos
Diabetes Mellitus Tipo 1 , Células Secretoras de Insulina , Adolescente , Humanos , Criança , Feminino , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Peptídeo C/metabolismo , Peptídeo C/farmacologia , Peptídeo C/uso terapêutico , Método Duplo-Cego , Verapamil/efeitos adversos , Células Secretoras de Insulina/efeitos dos fármacosRESUMO
BACKGROUND: Prompt and reliable management of hypoglycemia in youth with diabetes is important to prevent serious medical complications. OBJECTIVES: To determine efficacy, pharmacodynamics (PD), pharmacokinetics (PK), safety, and tolerability of a ready-to-use, liquid stable glucagon formulation administered subcutaneously via an autoinjector pen to youth with type 1 diabetes (T1D). METHODS: After plasma glucose concentration was < 80 mg/dL (< 4.4 mmol/L) after insulin, participants aged 2 to < 12 years with T1D were administered 0.5 mg of glucagon; participants aged 12 to < 18 years instead received 1 mg of glucagon. Then, adolescents were challenged with 0.5 mg after a 7- to 28-day washout period. Primary endpoint was mean plasma glucose concentration at 30 min after glucagon. RESULTS: Plasma glucose concentrations significantly (p < 0.001) increased from baseline to 30 min after glucagon, with mean change in plasma glucose concentration between baseline and 30 min for each age cohort as follows: 2 to < 6 years (n = 7; 81.4 mg/dL [4.5 mmol/L]); 6 to < 12 years (13; 84.2 mg/dL [4.7 mmol/L]); 12 to < 18 years (11; dose, 1 mg; 54.0 mg/dL [3.0 mmol/L]); and 12 to < 18 years (11; 0.5 mg; 52.4 mg/dL [2.9 mmol/L]). Among age cohorts, no clinically relevant differences were observed for PD and PK parameters. Common adverse events were nausea, vomiting, and hypoglycemia. CONCLUSION: Age-appropriate dosing of this glucagon formulation was effective at 30 min in reversing plasma glucose concentrations from < 80 mg/dL in youth with T1D.
Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Liberação de Medicamentos , Glucagon , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes , Insulina , TemperaturaRESUMO
Automated insulin delivery (AID) systems, which connect an insulin pump, continuous glucose monitoring system, and software algorithm to automate insulin delivery based on real-time glycemic data, hold promise for improving outcomes and reducing therapeutic burden for people with diabetes. This article reviews the features of the Omnipod 5 Automated Insulin Delivery System and how it compares to other AID systems available on or currently under review for the U.S. market. It also provides practical guidance for clinicians on how to effectively train and onboard people with diabetes on the Omnipod 5 System, including how to personalize therapy and optimize glycemia. Many people with diabetes receive their diabetes care in primary care settings rather than in a diabetes specialty clinic. Therefore, it is important that primary care providers have access to resources to support the adoption of AID technologies such as the Omnipod 5 System.
RESUMO
OBJECTIVE: Many youth do not use the hybrid closed-loop system for type 1 diabetes effectively. This study evaluated the impact of financial incentives for diabetes-related tasks on use of the 670G hybrid closed-loop system and on glycemia. METHODS: At auto mode initiation and for 16 weeks thereafter, participants received a flat rate for wearing and calibrating the sensor ($1/day), administering at least 3 mealtime insulin boluses per day ($1/day), and uploading ($5/week). Weekly bonuses were given for maintaining at least 70% of the time in auto mode, which were increased for persistent auto mode use from $3/week to a maximum of $13/week. If a participant failed to maintain auto mode for a week, the rewards were reset to baseline. Data from 17 participants aged 15.9 years ± 2.5 years (baseline hemoglobin A1c [HbA1c] 8.6% ± 1.1%) were collected at 6, 12, and 16 weeks. The reinforcers were withdrawn at 16 weeks, with a follow-up assessment at 24 weeks. RESULTS: With reinforcers, the participants administered an average of at least 3 mealtime insulin boluses per day and wore the sensor over 70% of the time. However, auto mode use waned. HbA1c levels decreased by 0.5% after 6 weeks, and this improvement was maintained at 12 and 16 weeks (P < .05). Upon withdrawal of reinforcers, HbA1c levels increased back to baseline at 24 weeks. CONCLUSION: Compensation for diabetes-related tasks was associated with lower HbA1c levels, consistent administration of mealtime insulin boluses, and sustained sensor use. These results support the potential of financial rewards for improving outcomes in youth with type 1 diabetes.
Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Economia Comportamental , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Projetos PilotoRESUMO
OBJECTIVE: To provide evidence-based recommendations regarding the use of advanced technology in the management of persons with diabetes mellitus to clinicians, diabetes-care teams, health care professionals, and other stakeholders. METHODS: The American Association of Clinical Endocrinology (AACE) conducted literature searches for relevant articles published from 2012 to 2021. A task force of medical experts developed evidence-based guideline recommendations based on a review of clinical evidence, expertise, and informal consensus, according to established AACE protocol for guideline development. MAIN OUTCOME MEASURES: Primary outcomes of interest included hemoglobin A1C, rates and severity of hypoglycemia, time in range, time above range, and time below range. RESULTS: This guideline includes 37 evidence-based clinical practice recommendations for advanced diabetes technology and contains 357 citations that inform the evidence base. RECOMMENDATIONS: Evidence-based recommendations were developed regarding the efficacy and safety of devices for the management of persons with diabetes mellitus, metrics used to aide with the assessment of advanced diabetes technology, and standards for the implementation of this technology. CONCLUSIONS: Advanced diabetes technology can assist persons with diabetes to safely and effectively achieve glycemic targets, improve quality of life, add greater convenience, potentially reduce burden of care, and offer a personalized approach to self-management. Furthermore, diabetes technology can improve the efficiency and effectiveness of clinical decision-making. Successful integration of these technologies into care requires knowledge about the functionality of devices in this rapidly changing field. This information will allow health care professionals to provide necessary education and training to persons accessing these treatments and have the required expertise to interpret data and make appropriate treatment adjustments.
Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus/terapia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Qualidade de Vida , Tecnologia , Estados UnidosRESUMO
Importance: Adolescents and young adults with type 1 diabetes exhibit the worst glycemic control among individuals with type 1 diabetes across the lifespan. Although continuous glucose monitoring (CGM) has been shown to improve glycemic control in adults, its benefit in adolescents and young adults has not been demonstrated. Objective: To determine the effect of CGM on glycemic control in adolescents and young adults with type 1 diabetes. Design, Setting, and Participants: Randomized clinical trial conducted between January 2018 and May 2019 at 14 endocrinology practices in the US including 153 individuals aged 14 to 24 years with type 1 diabetes and screening hemoglobin A1c (HbA1c) of 7.5% to 10.9%. Interventions: Participants were randomized 1:1 to undergo CGM (CGM group; n = 74) or usual care using a blood glucose meter for glucose monitoring (blood glucose monitoring [BGM] group; n = 79). Main Outcomes and Measures: The primary outcome was change in HbA1c from baseline to 26 weeks. There were 20 secondary outcomes, including additional HbA1c outcomes, CGM glucose metrics, and patient-reported outcomes with adjustment for multiple comparisons to control for the false discovery rate. Results: Among the 153 participants (mean [SD] age, 17 [3] years; 76 [50%] were female; mean [SD] diabetes duration, 9 [5] years), 142 (93%) completed the study. In the CGM group, 68% of participants used CGM at least 5 days per week in month 6. Mean HbA1c was 8.9% at baseline and 8.5% at 26 weeks in the CGM group and 8.9% at both baseline and 26 weeks in the BGM group (adjusted between-group difference, -0.37% [95% CI, -0.66% to -0.08%]; P = .01). Of 20 prespecified secondary outcomes, there were statistically significant differences in 3 of 7 binary HbA1c outcomes, 8 of 9 CGM metrics, and 1 of 4 patient-reported outcomes. The most commonly reported adverse events in the CGM and BGM groups were severe hypoglycemia (3 participants with an event in the CGM group and 2 in the BGM group), hyperglycemia/ketosis (1 participant with an event in CGM group and 4 in the BGM group), and diabetic ketoacidosis (3 participants with an event in the CGM group and 1 in the BGM group). Conclusions and Relevance: Among adolescents and young adults with type 1 diabetes, continuous glucose monitoring compared with standard blood glucose monitoring resulted in a small but statistically significant improvement in glycemic control over 26 weeks. Further research is needed to understand the clinical importance of the findings. Trial Registration: ClinicalTrials.gov Identifier: NCT03263494.
Assuntos
Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/sangue , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Adolescente , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética , Feminino , Humanos , Hiperglicemia/diagnóstico , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Masculino , Aplicativos Móveis , Monitorização Ambulatorial/instrumentação , Adulto JovemRESUMO
OBJECTIVE: Many youth with diabetes struggle to meet glycemic targets. The new ultralong duration of action of insulin degludec (iDeg) holds potential to ameliorate missed doses of basal insulin and improve glycemic control in youth with diabetes. METHODS: A retrospective chart review was undertaken of youth age 13 to <24 years in our practice with type 1 diabetes (T1D) or type 2 diabetes (T2D) who had been switched from glargine or detemir to iDeg to evaluate the impact of this transition on glycemic control. RESULTS: Glycated hemoglobin A1c (HbA1c) in youth with T1D (n = 82) remained stable during 6 months of treatment with iDeg (10.1 ± 2.11% [87 ± 23 mmol/mol] at start of iDeg compared to 10.1 ± 2.12% [87 ± 23 mmol/mol] at 6 months of treatment), whereas in youth with T2D (n = 16), HbA1c significantly declined from 10.6 ± 2.3% (92 ± 25 mmol/mol) to 8.3 ± 2.2% (67 ± 24 mmol/mol) ( P = .0024). CONCLUSION: In youth switched to iDeg, which in our practice is commonly due to ineffectiveness of the patient's current regimen, the outcome differences we saw may be due to preserved beta-cell function in youth with T2D. It remains to be seen whether there are benefits of transition to iDeg in youth with T1D beyond glycemic outcomes, such as reduction in ketosis and episodes of diabetic ketoacidosis. ABBREVIATIONS: DKA = diabetic ketoacidosis; DPV = Diabetes-Patienten-Verlaufsdokumentation (German/Austrian Prospective Diabetes Follow-Up Registry); HbA1c = glycated hemoglobin A1c; iDeg = insulin degludec; T1D = type 1 diabetes; T2D = type 2 diabetes.
Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Insulina de Ação Prolongada/uso terapêutico , Hemoglobinas Glicadas , Humanos , Hipoglicemiantes , Insulina Glargina , Estudos Prospectivos , Estudos RetrospectivosRESUMO
BACKGROUND: To assess the change in rates of pediatric real-time or intermittent scanning continuous glucose monitoring (CGM) use over the past 5 years, and how it impacts glycemic control, data from two registries were compared: the US-based type 1 diabetes Exchange Registry (T1DX) and the German/Austrian DPV (Prospective Diabetes Follow-Up Registry). METHODS: Registry participants aged <18 years with T1D duration ≥1 year encompassed 29 007 individuals in 2011 and 29 150 participants in 2016. Demographic data, CGM use and hemoglobin A1c (HbA1c) were obtained from medical records. RESULTS: CGM use increased from 2011 to 2016 in both registries across all age groups, regardless of gender, ethnic minority status or insulin delivery method. The increase in CGM use was most pronounced in the youngest patients, and usage rates remain lowest for adolescent patients in 2016. For both registries in 2016, mean HbA1c was lower among CGM users regardless of insulin delivery method compared to pump only (P < 0.001) and injection only (P < 0.001), and CGM users were more likely to achieve glycemic target of HbA1c <7.5% (56% vs 43% for DPV and 30% vs 15% for T1DX, P < 0.001). T1DX participants had a higher mean HbA1c compared with DPV despite whether they were CGM users or non-users; however, the difference was less pronounced in CGM users (P < 0.001). CONCLUSIONS: Pediatric CGM use increased in both registries and was associated with lower mean HbA1c regardless of insulin delivery modality.
Assuntos
Automonitorização da Glicemia/estatística & dados numéricos , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Sistema de Registros , Dispositivos Eletrônicos Vestíveis/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , MasculinoRESUMO
BACKGROUND: Despite significant advances in type 1 diabetes (T1D) management, achieving targeted glycemic control in pediatric patients remains a struggle. Continuous glucose monitoring (CGM) with remote access holds the promise to address this challenge by allowing caregivers to monitor glucose, even when the child is not directly under their supervision. OBJECTIVE: To explore real-time and remote CGM practices in homes and schools, including caregiver expectations regarding this technology. SUBJECTS: Parents and daytime caregivers. METHODS: Respondents answered an anonymous survey assessing characteristics of CGM use. Cross-sectional data were collected and analyzed using quantitative and qualitative methods. RESULTS: Thirty-three parents and 17 daytime caregivers responded. Threshold alerts (alerts when patients reached certain pre-set high or low limits) were used most frequently, followed by rate of change alerts. Most parents and daytime caregivers responded to low- and high-threshold CGM alerts by confirming with a glucose meter prior to treatment; while about one-third endorsed treating lows without a confirmatory test. Most parents expected their child's daytime caregiver to respond to CGM alerts and daytime caregivers felt the parent's expectations of them were reasonable. All parents and most caregivers reported decreased overall worry/stress. Parents felt positive about CGM use and daytime caregivers felt comfortable with CGM. CONCLUSION: The positive and collaborative management reported by parents and daytime caregivers sets the stage for CGM to play an important role in the management of children with T1D both in the home and in the school settings.
Assuntos
Glicemia , Cuidadores/psicologia , Alarmes Clínicos/estatística & dados numéricos , Diabetes Mellitus Tipo 1 , Monitorização Ambulatorial/psicologia , Adolescente , Adulto , Cuidadores/estatística & dados numéricos , Criança , Pré-Escolar , Gerenciamento Clínico , Humanos , Monitorização Ambulatorial/estatística & dados numéricos , Pais/psicologia , Serviços de Saúde Escolar , Inquéritos e QuestionáriosAssuntos
Diabetes Mellitus Tipo 1 , Glicemia , Automonitorização da Glicemia , Criança , Pré-Escolar , Estudos de Coortes , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose/uso terapêutico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de InsulinaRESUMO
BACKGROUND: Automated insulin delivery systems, utilizing a control algorithm to dose insulin based upon subcutaneous continuous glucose sensor values and insulin pump therapy, will soon be available for commercial use. The objective of this study was to determine the preliminary safety and efficacy of initialization parameters with the Medtronic hybrid closed-loop controller by comparing percentage of time in range, 70-180 mg/dL (3.9-10 mmol/L), mean glucose values, as well as percentage of time above and below target range between sensor-augmented pump therapy and hybrid closed-loop, in adults and adolescents with type 1 diabetes. METHODS: We studied an initial cohort of 9 adults followed by a second cohort of 15 adolescents, using the Medtronic hybrid closed-loop system with the proportional-integral-derivative with insulin feed-back (PID-IFB) algorithm. Hybrid closed-loop was tested in supervised hotel-based studies over 4-5 days. RESULTS: The overall mean percentage of time in range (70-180 mg/dL, 3.9-10 mmol/L) during hybrid closed-loop was 71.8% in the adult cohort and 69.8% in the adolescent cohort. The overall percentage of time spent under 70 mg/dL (3.9 mmol/L) was 2.0% in the adult cohort and 2.5% in the adolescent cohort. Mean glucose values were 152 mg/dL (8.4 mmol/L) in the adult cohort and 153 mg/dL (8.5 mmol/L) in the adolescent cohort. CONCLUSIONS: Closed-loop control using the Medtronic hybrid closed-loop system enables adaptive, real-time basal rate modulation. Initializing hybrid closed-loop in clinical practice will involve individualizing initiation parameters to optimize overall glucose control.
Assuntos
Atividades Cotidianas , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose/metabolismo , Hiperglicemia/prevenção & controle , Pâncreas Artificial , Medicina de Precisão , Tela Subcutânea/efeitos dos fármacos , Adolescente , Comportamento do Adolescente , Adulto , Algoritmos , Glicemia/análise , Automonitorização da Glicemia , Calibragem , Estudos de Coortes , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/metabolismo , Cálculos da Dosagem de Medicamento , Monitoramento de Medicamentos , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Pâncreas Artificial/efeitos adversos , Tela Subcutânea/metabolismo , Adulto JovemRESUMO
AIMS/HYPOTHESIS: While the use of insulin pumps in paediatrics has expanded dramatically, there is still considerable variability among countries in the use of pump technology. The present study sought to describe differences in metabolic control and pump use in young people with type 1 diabetes using data collected in three multicentre registries. METHODS: Data for the years 2011 and 2012 from 54,410 children and adolescents were collected from the Prospective Diabetes Follow-up Registry (DPV; n = 26,198), T1D Exchange (T1DX; n = 13,755) and the National Paediatric Diabetes Audit (NPDA; n = 14,457). The modality of insulin delivery, based on age, sex and ethnic minority status, and the impact of pump use on HbA1c levels were compared. RESULTS: The overall mean HbA1c level was higher in the NPDA (8.9 ± 1.6% [74 ± 17.5 mmol/mol]) than in the DPV (8.0 ± 1.6% [64 ± 17.0 mmol/mol], p < 0.001) and T1DX (8.3 ± 1.4% [68 ± 15.4 mmol/mol], p < 0.001). Conversely, pump use was much lower in the NPDA (14%) than in the DPV (41%, p < 0.001) and T1DX (47%, p < 0.001). In a pooled analysis, pump use was associated with a lower mean HbA1c (pump: 8.0 ± 1.2% [64 ± 13.3 mmol/mol] vs injection: 8.5 ± 1.7% [69 ± 18.7 mmol/mol], p < 0.001). In all three registries, those with an ethnic minority status were less likely to be treated with a pump (p < 0.001) and boys were treated with a pump less often compared with girls (p < 0.001). CONCLUSIONS/INTERPRETATION: Despite similar clinical characteristics and proportion of minority participants, substantial differences in metabolic control exist across the three large transatlantic registries of paediatric patients with type 1 diabetes, which appears to be due in part to the frequency of insulin pump therapy.