Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Arthroplasty ; 38(12): 2667-2672, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37321520

RESUMO

BACKGROUND: We aimed to evaluate the mean 14-year outcomes of hybrid total hip arthroplasty (THA) with cementless acetabular cups using bulk femoral head autografts in acetabular reconstruction and specify the radiological characteristics of cementless acetabular cups using this technique. METHODS: This retrospective study included 98 patients (123 hips) who underwent hybrid THA with a cementless acetabular cup using bulk femoral head autografts for bone deficiency in acetabular dysplasia and who were followed-up for a mean of 14 years (range, 10 to 19.6). The percentage of bone coverage index (BCI) and cup center-edge (CE) angles were evaluation radiologically of acetabular host bone coverage. The survival rate of the cementless acetabular cup and autograft bone ingrowth were assessed. RESULTS: The survival rate with all revisions of cementless acetabular cups was 97.1% (95% confidence interval: 91.2 to 99.1). The autograft bone was remodeled or reoriented in all cases except in 2 hips where the bulk femoral head autograft collapsed. Radiological evaluation revealed a mean cup CE angle of -17.8° (range, -52 to -7°) and a BCI of 44.4% (range, 10 to 75.4%). CONCLUSION: Cementless acetabular cups using bulk femoral head autografts for bone deficiency of the acetabular roof remained stable even if the average BCI was 44.4% and the average cup CE angle was -17.8°. Cementless acetabular cups using these techniques showed good 10-year to 19.6-year outcomes and viabilities of graft bones.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Autoenxertos/cirurgia , Estudos Retrospectivos , Cabeça do Fêmur/cirurgia , Acetábulo/cirurgia , Seguimentos
2.
BMC Musculoskelet Disord ; 23(1): 646, 2022 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-35794611

RESUMO

BACKGROUND: Total hip arthroplasty after osteotomy is more technically challenging than primary total hip arthroplasty, especially concerning cup placement. This is attributed to bone morphological abnormalities caused by acetabular bone loss and osteophyte formation. This study aimed to investigate the clinical and radiological outcomes of total hip arthroplasty after rotational acetabular osteotomy compared with those of primary total hip arthroplasty, focusing mainly on acetabular deformity and cup position. METHODS: The study included 22 hips that had undergone rotational acetabular osteotomy and 22 hips in an age- and sex-matched control group of patients who underwent total hip arthroplasties between 2005 and 2020. We analyzed cup abduction and anteversion; lateral, anterior, and posterior cup center-edge angle; hip joint center position; femoral anteversion angle; and presence of acetabular defect using postoperative radiography and computed tomography. Operative results and clinical evaluations were also analyzed. RESULTS: The clinical evaluation showed that the postoperative flexion range of motion was lower in total hip arthroplasty after rotational acetabular osteotomy than in primary total hip arthroplasty, although no significant difference was noted in the postoperative total Japanese Orthopedic Association hip score. The operative time was significantly longer in the rotational acetabular osteotomy group than in the control group, but there was no significant difference in blood loss. The lateral cup center-edge angle was significantly higher and the posterior cup center-edge angle was significantly lower in the total hip arthroplasty after rotational acetabular osteotomy, suggesting a posterior bone defect existed in the acetabulum. In total hip arthroplasty after rotational acetabular osteotomy, the hip joint center was located significantly superior and lateral to the primary total hip arthroplasty. CONCLUSIONS: In total hip arthroplasty after rotational acetabular osteotomy, the cup tended to be placed in the superior and lateral positions, where there was more bone volume. The deformity of the acetabulum and the high hip center should be considered for treatment success because they may cause cup instability, limited range of motion, and impingement.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Hiperplasia , Osteotomia/efeitos adversos
3.
J Bone Miner Metab ; 37(5): 768-772, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31079208

RESUMO

Subchondral insufficiency fractures of the femoral head are generally considered to be osteoporosis-related fragility fractures. There have been reports of microfractures being found in subchondral bone on pathological examination. However, the mechanism of these microfractures is not known. In this report, we describe a patient with osteogenesis imperfecta who developed a subchondral insufficiency fracture of the femoral head after a fall that had resulted in a subcapital femoral neck fracture. Bipolar hemiarthroplasty was performed, and bone at the femoral head and neck was sampled for pathophysiological examination. Hematoxylin and eosin staining revealed microfractures and microcallus in the subchondral bone in the femoral head, indicating healing of a subchondral insufficiency fracture before the subcapital femoral neck fracture. Moreover, decreased bone volume and accumulated microdamage were observed in the subchondral bone but not in the cancellous bone in the femoral neck. These findings suggest that subchondral insufficiency fracture of the femoral head is a stress fracture caused by accumulation of microdamage in fragile subchondral bone.


Assuntos
Cabeça do Fêmur/lesões , Fraturas de Estresse/etiologia , Fraturas do Quadril/etiologia , Osteogênese Imperfeita/complicações , Adulto , Osso Esponjoso/patologia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/patologia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/patologia , Humanos , Masculino , Tamanho do Órgão , Osteogênese Imperfeita/diagnóstico por imagem
4.
J Bone Miner Metab ; 37(5): 880-885, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30701320

RESUMO

In end-stage osteoarthritis (OA) of the hip, the effect of bone metabolism with and without cartilage is unclear. In this study, we aimed to investigate histomorphology and microdamage in the subchondral bone of the femoral head in areas with and without articular cartilage in patients with end-stage OA. Nineteen femoral heads were evaluated in 10 women who underwent total hip arthroplasty for OA and in nine cadaveric controls (CNT). Chondral thickness and subchondral bone plate thickness (SBP.Th) were measured in 5-mm-wide areas where cartilage was lost (area A) or preserved (area B) in OA and in corresponding areas in the load-bearing portion of the femoral head in the CNT. Histomorphometry and microdamage in 5 × 5-mm areas of cancellous bone were assessed. SBP.Th and bone volume were significantly greater in area A than in area B or in the CNT. Osteoid volume was significantly greater in area A than in area B or in the CNT. There was no significant difference in eroded surface between area A and CNT. Microcrack density was significantly greater in area A than in area B or in the CNT. Although accumulation of microdamage was caused by concentration of stress on the subchondral bone in the cartilage loss area in end-stage OA, remodeling for microdamage repairing mechanism was not enhanced. It was considered that the subchondral cancellous bone volume was increased because of modeling, not remodeling, by stress concentration due to articular cartilage loss.


Assuntos
Cabeça do Fêmur/patologia , Quadril/patologia , Osteoartrite/patologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Osso Esponjoso/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Orthop Surg ; 13(7): 2177-2181, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34549883

RESUMO

BACKGROUND: Developmental dysplasia of the hip (DDH) is the main factor that causes secondary osteoarthritis of the hip (hip OA). Acetabular retroversion results in pincer-type femoroacetabular impingement (FAI), and this is also known to cause secondary hip OA. However, few cases of DDH with acetabular retroversion have been reported, and there is no definite opinion on the optimal treatment. We report a rare case of DDH and FAI owing to acetabular retroversion and dysostosis of the sacroiliac joint that was treated with eccentric acetabular rotational osteotomy (ERAO) using navigation guidance. CASE PRESENTATION: A 27-year-old woman presented with DDH and acetabular retroversion with FAI and dysostosis of the sacroiliac joint on the contralateral side. We performed ERAO using computed navigation guidance and improved the coverage and retroversion of the acetabulum. The acetabular anteversion angle improved from 1° retroversion to 9° anteversion after surgery, the center edge angle improved from 18° to 43°, and the acetabular head index improved from 69% to 93%. The cam lesion of the femur was resected. The Harris Hip Score improved from 55.7 to 100 points at the final examination 2 years after surgery. CONCLUSIONS: In this rare case of DDH and FAI, ERAO using computed navigation guidance accurately improved the coverage and retroversion of the acetabulum.


Assuntos
Acetábulo/cirurgia , Displasia do Desenvolvimento do Quadril/cirurgia , Impacto Femoroacetabular/cirurgia , Osteotomia/métodos , Articulação Sacroilíaca/fisiopatologia , Cirurgia Assistida por Computador/métodos , Adulto , Feminino , Humanos , Inquéritos e Questionários
6.
Medicine (Baltimore) ; 100(47): e27924, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34964765

RESUMO

ABSTRACT: This article introduces our lasso loop technique (LLT) using a bioabsorbable thread for the treatment of intra-articular distal radius fractures with displaced dorsal bone fragment containing articular surface (DBF). We also examined whether the articular gap is sufficiently reduced and maintained by the LLT, along with the results of other radiological and clinical evaluations. We retrospectively reviewed 19 patients who underwent LLT for intra-articular distal radius fracture with a displaced DBF. Patient radiographic images and medical records were used to investigate radiological characteristics, symptoms, physical findings, and the Quick Disabilities of the Arm, Shoulder, and Hand scores. Sagittal-view computed tomography showed that the mean preoperative articular gap was 2.6 mm, but the gap was reduced by LLT, and the gap immediately postoperatively was <1.0 mm in all patients. No re-displacement of the DBF was evident from immediately postoperatively to 6 months postoperatively. Postoperatively, no losses of correction in palmar tilt, radial inclination, or ulnar variance were seen in the evaluation of plain radiographs, and satisfactory joint range of motion, grip strength, and the Quick Disabilities of the Arm, Shoulder, and Hand score were obtained. No significant complications due to LLT were observed. LLT appears to offer a simple and effective procedure to reduce displaced DBF with little risk of complications. LLT may become a useful option in the treatment of intra-articular distal radius fractures with displaced DBF.


Assuntos
Implantes Absorvíveis , Artroscopia/métodos , Fixação Interna de Fraturas , Fraturas do Rádio/cirurgia , Técnicas de Sutura , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Fraturas do Rádio/diagnóstico por imagem , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
7.
Medicine (Baltimore) ; 99(41): e22494, 2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-33031285

RESUMO

INTRODUCTION: Sneathia sanguinegens(S sanguinegens) is a gram-negative rod-shaped bacterium mostly reported to cause a perinatal infection, and there are no reports of S sanguinegens in prosthetic joint infection (PJI). The purpose of this report is to describe a very rare case of PJI after total hip arthroplasty (THA) caused by S sanguinegens. PATIENT CONCERNS: A 79-year-old woman presented with right coxalgia, inability to walk, and a fever of 39°C. She had undergone THA 28 years earlier for osteoarthritis of the hip. DIAGNOSES: The diagnosis was acute late-onset PJI, because blood tests revealed marked inflammatory reaction and computed tomography showed an abscess at the right hip joint; synovial fluid analysis resulted in detection of a gram-negative bacillus. INTERVENTION: Surgical debridement with retention of the implant and antibiotic therapy was performed. OUTCOMES: One month after surgery, polymerase chain reaction (PCR) assay showed that the pathogen was 99.9% likely to be S sanguinegens. There has been no recurrence of infection or loosening of the implant in the 2 years since her surgery. LESSONS: PCR should facilitate detection of previously unknown pathogens and potentially novel bacterial species.


Assuntos
Fusobactérias , Infecções por Bactérias Gram-Negativas/complicações , Infecções Relacionadas à Prótese/microbiologia , Idoso , Antibacterianos/uso terapêutico , Artroplastia de Quadril , Feminino , Fusobactérias/isolamento & purificação , Infecções por Bactérias Gram-Negativas/diagnóstico , Humanos , Reação em Cadeia da Polimerase , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA