Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Thorac Cardiovasc Surg ; 30(1)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-37423751

RESUMO

The excellent long-term patency of no-touch (NT) saphenous vein grafts (SVGs) makes the grafts very attractive for coronary artery bypass grafting; however, NT-SVG harvesting has a greater incidence of wound complications than conventional methods. Since 2009, we have performed endoscopic vein harvesting (EVH) in our department with very few major wound complications. Because NT-SVG harvesting is expected to provide long-term patency, if performed with EVH, the incidence of wound complications will be reduced. Thus, we began performing endoscopic pedicle SVG harvesting (Pedicle-EVH) in March 2019. Herein, we report the early results obtained using our current Pedicle-EVH procedure. No major wound complications were reported, and the early results, including patency, were satisfactory. To harvest the pedicle SVG, however, we used a different method than the NT-SVG procedure, so careful monitoring will be needed to assess long-term outcomes.


Assuntos
Ponte de Artéria Coronária , Veia Safena , Humanos , Veia Safena/transplante , Resultado do Tratamento , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Coleta de Tecidos e Órgãos/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos , Endoscopia/efeitos adversos , Endoscopia/métodos , Grau de Desobstrução Vascular
2.
Asian Cardiovasc Thorac Ann ; 31(2): 75-80, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36330614

RESUMO

BACKGROUND: Total arch replacement (TAR) with a frozen elephant trunk (FET) is a common technique for acute aortic dissection, but there is no consensus on the optimal size of the FET. METHODS: Forty-four patients who underwent TAR with FET for acute aortic dissection at our hospital since 2014 were included. The aortic diameter obtained from FET was measured on postoperative computed tomography (CT) and the estimated oversizing ratio was calculated. We investigated the relationship between the estimated oversizing ratio and postoperative outcomes. We also measured the maximum true lumen diameter, circumference of the true lumen, and total aortic diameter at the same level as the FET end on preoperative CT and examined the correlation with the aortic diameter obtained from FET. RESULTS: The average estimated oversizing ratio was 109%. Early postoperative CT showed complete thrombosis of the false lumen in 41 (93.2%) patients. No distal stent graft-induced new entry occurred during follow-up. The correlation coefficients between the three measurements and aortic diameter obtained from FET were 0.64 (maximum true lumen diameter), 0.76 (true lumen diameter calculated from circumference), and 0.72 (total aortic diameter), respectively. CONCLUSIONS: The aortic diameter obtained from FET on postoperative CT was strongly correlated with the true lumen diameter calculated from the circumference and total aortic diameter on preoperative CT. It is reasonable to select a size of approximately 130% of the true lumen diameter calculated from the circumference or 80% to 85% of the total aortic diameter.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Prótese Vascular , Stents , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA