Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Emerg Radiol ; 22(4): 351-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25563705

RESUMO

The purpose of this study was to determine the relationship between admission visual acuity (VA) and facial computed tomographic (CT) findings of traumatic optic neuropathy (TON). We retrospectively evaluated CT findings in 44 patients with TON. Mid-facial fractures, extraconal and intraconal hematomas, hematomas along the optic nerve and the posterior globe, optic canal fracture, nerve impingement by optic canal fracture fragment, and extraconal and intraconal emphysema were evaluated. CT variables of patients with and without available VA were compared. VA was converted into logarithm of the minimum angle of resolution (logMAR) to provide a numeric scale for the purpose of statistical analysis. The risk factors related to poor VA on univariate analysis were as follows: intraconal hematoma [median logMAR -4.7 versus -1.15, p = 0.016] and hematoma along the optic nerve [median -4.7 versus -1.3, p = 0.029]. Intraconal hematoma was the best predictor of poor VA (coefficient, 1.01; SE, 0.34; and p = 0.008). Receiver operating characteristic (ROC) curve analysis showed that the presence of intraconal hematoma and hematoma along the optic nerve predicted poor VA (logMAR of -3.7 or lower) with an area under the curve of 0.8 and 0.85, respectively. TON patients at higher risk of severe visual impairment may be identified based on admission facial CT.


Assuntos
Traumatismos do Nervo Óptico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Acuidade Visual , Ferimentos não Penetrantes/diagnóstico por imagem , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos do Nervo Óptico/etiologia , Estudos Retrospectivos , Fatores de Risco , Ferimentos não Penetrantes/etiologia
2.
Radiology ; 272(3): 824-31, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24758554

RESUMO

PURPOSE: To determine the specific facial computed tomographic (CT) findings that can be used to predict traumatic optic neuropathy (TON) in patients with blunt craniofacial trauma and propose a scoring system to identify patients at highest risk of TON. MATERIALS AND METHODS: This study was compliant with HIPAA, and permission was obtained from the institutional review board. Facial CT examination findings in 637 consecutive patients with a history of blunt facial trauma were evaluated retrospectively. The following CT variables were evaluated: midfacial fractures, extraconal hematoma, intraconal hematoma, hematoma along the optic nerve, hematoma along the posterior globe, optic canal fracture, nerve impingement by optic canal fracture fragment, extraconal emphysema, and intraconal emphysema. A prediction model was derived by using regression analysis, followed by receiver operating characteristic analysis to assess the diagnostic performance. To examine the degree of overfitting of the prediction model, a k-fold cross-validation procedure (k = 5) was performed. The ability of the cross-validated model to allow prediction of TON was examined by comparing the mean area under the receiver operating characteristic curve (AUC) from cross-validations with that obtained from the observations used to create the model. RESULTS: The five CT variables with significance as predictors were intraconal hematoma (odds ratio, 12.73; 95% confidence interval [CI]: 5.16, 31.42; P < .001), intraconal emphysema (odds ratio, 5.21; 95% CI: 2.03, 13.36; P = .001), optic canal fracture (odds ratio, 4.45; 95% CI: 1.91, 10.35; P = .001), hematoma along the posterior globe (odds ratio, 0.326; 95% CI: 0.111, 0.958; P = .041), and extraconal hematoma (odds ratio, 2.36; 95% CI: 1.03, 5.41; P = .042). The AUC was 0.818 (95% CI: 0.734, 0.902) for the proposed model based on the observations used to create the model and 0.812 (95% CI: 0.723, 0.9) after cross-validation, excluding substantial overfitting of the model. CONCLUSION: The risk model developed may help radiologists suggest the possibility of TON and prioritize ophthalmology consults. However, future external validation of this prediction model is necessary.


Assuntos
Traumatismos Faciais/diagnóstico por imagem , Traumatismos Faciais/epidemiologia , Traumatismos do Nervo Óptico/diagnóstico por imagem , Traumatismos do Nervo Óptico/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/epidemiologia , Adolescente , Adulto , Idoso , Comorbidade , Face/diagnóstico por imagem , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/diagnóstico por imagem , Traumatismo Múltiplo/epidemiologia , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Índices de Gravidade do Trauma , Estados Unidos/epidemiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA