Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res ; 24(1): 93, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36539895

RESUMO

BACKGROUND: Breast cancer (BC) grading plays a critical role in patient management despite the considerable inter- and intra-observer variability, highlighting the need for decision support tools to improve reproducibility and prognostic accuracy for use in clinical practice. The objective was to evaluate the ability of a digital artificial intelligence (AI) assay (PDxBr) to enrich BC grading and improve risk categorization for predicting recurrence. METHODS: In our population-based longitudinal clinical development and validation study, we enrolled 2075 patients from Mount Sinai Hospital with infiltrating ductal carcinoma of the breast. With 3:1 balanced training and validation cohorts, patients were retrospectively followed for a median of 6 years. The main outcome was to validate an automated BC phenotyping system combined with clinical features to produce a binomial risk score predicting BC recurrence at diagnosis. RESULTS: The PDxBr training model (n = 1559 patients) had a C-index of 0.78 (95% CI, 0.76-0.81) versus clinical 0.71 (95% CI, 0.67-0.74) and image feature models 0.72 (95% CI, 0.70-0.74). A risk score of 58 (scale 0-100) stratified patients as low or high risk, hazard ratio (HR) 5.5 (95% CI 4.19-7.2, p < 0.001), with a sensitivity 0.71, specificity 0.77, NPV 0.95, and PPV 0.32 for predicting BC recurrence within 6 years. In the validation cohort (n = 516), the C-index was 0.75 (95% CI, 0.72-0.79) versus clinical 0.71 (95% CI 0.66-0.75) versus image feature models 0.67 (95% CI, 0.63-071). The validation cohort had an HR of 4.4 (95% CI 2.7-7.1, p < 0.001), sensitivity of 0.60, specificity 0.77, NPV 0.94, and PPV 0.24 for predicting BC recurrence within 6 years. PDxBr also improved Oncotype Recurrence Score (RS) performance: RS 31 cutoff, C-index of 0.36 (95% CI 0.26-0.45), sensitivity 37%, specificity 48%, HR 0.48, p = 0.04 versus Oncotype RS plus AI-grade C-index 0.72 (95% CI 0.67-0.79), sensitivity 78%, specificity 49%, HR 4.6, p < 0.001 versus Oncotype RS plus PDxBr, C-index 0.76 (95% CI 0.70-0.82), sensitivity 67%, specificity 80%, HR 6.1, p < 0.001. CONCLUSIONS: PDxBr is a digital BC test combining automated AI-BC prognostic grade with clinical-pathologic features to predict the risk of early-stage BC recurrence. With future validation studies, we anticipate the PDxBr model will enrich current gene expression assays and enhance treatment decision-making.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/genética , Inteligência Artificial , Estudos Retrospectivos , Reprodutibilidade dos Testes , Receptor ErbB-2/metabolismo , Recidiva Local de Neoplasia/patologia , Prognóstico
2.
Opt Express ; 26(13): 17690-17696, 2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-30119579

RESUMO

Distributed acoustic sensing (DAS) via fiber-optic reflectometry techniques is finding more and more applications in recent years. In many of these applications, the position of detected acoustic or seismic sources is defined with a single longitudinal coordinate which specifies the distance between the detection point in the fiber to the DAS interrogator. In this paper we describe a DAS system which is intended to operate in a fluid (air or water) and to detect and localize moving objects, with three spatial coordinates, using the acoustic waves they generate or reflect and their Doppler shifts. The new method uses optical frequency domain reflectometry (OFDR) and lumped Rayleigh reflectors (LRR's) to ensure sufficiently high sensitivity for operation in fluid media. The new method was used to track a narrowband (CW) signal source.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA