Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Strahlenther Onkol ; 199(7): 621-630, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37285038

RESUMO

BACKGROUND: Single-session cardiac stereotactic radiation therapy (SBRT) has demonstrated promising results for patients with refractory ventricular tachycardia (VT). However, the full safety profile of this novel treatment remains unknown and very limited data from prospective clinical multicenter trials are available. METHODS: The prospective multicenter multiplatform RAVENTA (radiosurgery for ventricular tachycardia) study assesses high-precision image-guided cardiac SBRT with 25 Gy delivered to the VT substrate determined by high-definition endocardial and/or epicardial electrophysiological mapping in patients with refractory VT ineligible for catheter ablation and an implanted cardioverter defibrillator (ICD). Primary endpoint is the feasibility of full-dose application and procedural safety (defined as an incidence of serious [grade ≥ 3] treatment-related complications ≤ 5% within 30 days after therapy). Secondary endpoints comprise VT burden, ICD interventions, treatment-related toxicity, and quality of life. We present the results of a protocol-defined interim analysis. RESULTS: Between 10/2019 and 12/2021, a total of five patients were included at three university medical centers. In all cases, the treatment was carried out without complications. There were no serious potentially treatment-related adverse events and no deterioration of left ventricular ejection fraction upon echocardiography. Three patients had a decrease in VT episodes during follow-up. One patient underwent subsequent catheter ablation for a new VT with different morphology. One patient with local VT recurrence died 6 weeks after treatment in cardiogenic shock. CONCLUSION: The interim analysis of the RAVENTA trial demonstrates early initial feasibility of this new treatment without serious complications within 30 days after treatment in five patients. Recruitment will continue as planned and the study has been expanded to further university medical centers. TRIAL REGISTRATION NUMBER: NCT03867747 (clinicaltrials.gov). Registered March 8, 2019. Study start: October 1, 2019.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Radiocirurgia/métodos , Volume Sistólico , Estudos Prospectivos , Qualidade de Vida , Estudos de Viabilidade , Função Ventricular Esquerda , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
2.
J Appl Clin Med Phys ; 24(8): e14077, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37357570

RESUMO

INTRODUCTION: Performing lymphoscintigraphy in a separate room, frees up the conventional gamma camera, coupled with the desire to directly localize sentinel lymph nodes (SLN) in the operating theatre has led to the development of high-resolution semiconductor-detector based handheld gamma-cameras, CrystalCam. METHODS: This work consists of phantom and clinical studies. For the first part, a Jaszczak phantom with hollow spheres of various volumes were filled with the 99m Tc and the camera's sensitivity was measured at various distances to assess the possibilities and limitations of the device. The clinical study evaluates the effectiveness of CrystalCam in localizing SLN in 40 consecutive malignant melanoma patients compared to both conventional planar lymphoscintigraphy and hybrid SPECT/CT. SLNs detected by planar lymphoscintigraphy were marked on the patients' skin using a UV-marker. CrystalCam images were acquired in another room by another examiner and the SLNs were marked with a felt pen. The detected nodes by both camera systems were evaluated using UV-lamp and normal light to visualize the UV- and felt pen marks respectively. The concordance rate of the SLNs and higher-echelon nodes localized by both planar scintigraphy and CrystalCam imaging with respect to the total SLNs and higher-echelon nodes detected by SPECT/CT imaging are compared and statistically analyzed. RESULTS: The results of the phantom study show a good correlation between activity and count-rates for all distancesSPECT/CT, CrystalCamm, and planar lymphoscintigraphy detected 69, 58, and 61 SLNs respectively. The concordance rate of 95.65% by the CrystalCam and planar scintigraphy implies both cameras are statistically coequal in preoperative SLN detection of malignant melanoma. For the higher-echelon nodes, SPECT/CT, planar and CrystalCam imaging systems identified 82, 48, and 13 respectively; thus, CrystalCam was statistically inferior to planar imaging. CONCLUSION: The handheld CrystalCam is a reliable instrument for localizing SLNs in surgical centers without an on-site nuclear medicine department.


Assuntos
Melanoma , Linfonodo Sentinela , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfocintigrafia/métodos , Câmaras gama , Metástase Linfática , Melanoma/diagnóstico por imagem , Melanoma/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma Maligno Cutâneo
3.
Strahlenther Onkol ; 197(7): 581-591, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32588102

RESUMO

PURPOSE: For step-and-shoot robotic stereotactic radiosurgery (SRS) the dose delivered over time, called local tumor-dose-rate (TDR), may strongly vary during treatment of multiple lesions. The authors sought to evaluate technical parameters influencing TDR and correlate TDR to clinical outcome. MATERIAL AND METHODS: A total of 23 patients with 162 oligo (1-3) and multiple (>3) brain metastases (OBM/MBM) treated in 33 SRS sessions were retrospectively analyzed. Median PTV were 0.11 cc (0.01-6.36 cc) and 0.50 cc (0.12-3.68 cc) for OBM and MBM, respectively. Prescription dose ranged from 16 to 20 Gy prescribed to the median 70% isodose line. The maximum dose-rate for planning target volume (PTV) percentage p in time span s during treatment (TDRs,p) was calculated for various p and s based on treatment log files and in-house software. RESULTS: TDR60min,98% was 0.30 Gy/min (0.23-0.87 Gy/min) for OBM and 0.22 Gy/min (0.12-0.63 Gy/min) for MBM, respectively, and increased by 0.03 Gy/min per prescribed Gy. TDR60min,98% strongly correlated with treatment time (ρ = -0.717, p < 0.001), monitor units (MU) (ρ = -0.767, p < 0.001), number of beams (ρ = -0.755, p < 0.001) and beam directions (ρ = -0.685, p < 0.001) as well as lesions treated per collimator (ρ = -0.708, P < 0.001). Median overall survival (OS) was 20 months and 1­ and 2­year local control (LC) was 98.8% and 90.3%, respectively. LC did not correlate with any TDR, but tumor response (partial response [PR] or complete response [CR]) correlated with all TDR in univariate analysis (e.g., TDR60min,98%: hazard ration [HR] = 0.974, confidence interval [CI] = 0.952-0.996, p = 0.019). In multivariate analysis only concomitant targeted therapy or immunotherapy and breast cancer tumor histology remained a significant factor for tumor response. Local grade ≥2 radiation-induced tissue reactions were noted in 26.3% (OBM) and 5.2% (MBM), respectively, mainly influenced by tumor volume (p < 0.001). CONCLUSIONS: Large TDR variations are noted during MBM-SRS which mainly arise from prolonged treatment times. Clinically, low TDR corresponded with decreased local tumor responses, although the main influencing factor was concomitant medication.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Neoplasias Encefálicas/cirurgia , Humanos , Doses de Radiação , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
4.
Strahlenther Onkol ; 196(1): 23-30, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31673718

RESUMO

PURPOSE: Single-session cardiac stereotactic body radiotherapy, called cardiac radiosurgery (CRS) or radioablation (RA), may offer a potential treatment option for patients with refractory ventricular tachycardia (VT) and electrical storm who are otherwise ineligible for catheter ablation. However, there is only limited clinical experience. We now present the first-in-patient treatment using (CRS/RA) for VT in Germany. METHODS: A 78-year-old male patient with dilated cardiomyopathy and significantly reduced ejection fraction (15%) presented with monomorphic VT refractory to poly-anti-arrhythmic medication and causing multiple implantable cardioverter-defibrillator (ICD) interventions over the course of several weeks, necessitating prolonged treatment on an intensive care unit. Ultra-high-resolution electroanatomical voltage mapping (EVM) revealed a re-entry circuit in the cardiac septum inaccessible for catheter ablation. Based on the EVM, CRS/RA with a single session dose of 25 Gy (83% isodose) was delivered to the VT substrate (8.1 cc) using a c-arm-based high-precision linear accelerator on November 30, 2018. RESULTS: CRS/RA was performed without incident and dysfunction of the ICD was not observed. Following the procedure, a significant reduction in monomorphic VT from 5.0 to 1.6 episodes per week and of ICD shock interventions by 81.2% was observed. Besides periprocedural nausea with a single episode of vomiting, no treatment-associated side effects were noted. Unfortunately, the patient died 57 days after CRS/RA due to sepsis-associated cardiac circulatory failure after Clostridium difficile-associated colitis developed during rehabilitation. Histopathologic examination of the heart as part of a clinical autopsy revealed diffuse fibrosis on most sections of the heart without apparent differences between the target area and the posterior cardiac wall serving as a control. CONCLUSION: CRS/RA appears to be a possible treatment option for otherwise untreatable patients suffering from refractory VT and electrical storm. A relevant reduction in VT incidence and ICD interventions was observed, although long-term outcome and consequences of CRS/RA remain unclear. Clinical trials are strongly warranted and have been initiated.


Assuntos
Admissão do Paciente , Radiocirurgia/métodos , Taquicardia Ventricular/radioterapia , Idoso , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/radioterapia , Terapia Combinada , Desfibriladores Implantáveis , Evolução Fatal , Septos Cardíacos/patologia , Septos Cardíacos/efeitos da radiação , Humanos , Masculino , Aceleradores de Partículas , Taquicardia Ventricular/patologia
5.
Strahlenther Onkol ; 194(9): 843-854, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29802435

RESUMO

PURPOSE: To investigate the quality of treatment plans of spinal radiosurgery derived from different planning and delivery systems. The comparisons include robotic delivery and intensity modulated arc therapy (IMAT) approaches. Multiple centers with equal systems were used to reduce a bias based on individual's planning abilities. The study used a series of three complex spine lesions to maximize the difference in plan quality among the various approaches. METHODS: Internationally recognized experts in the field of treatment planning and spinal radiosurgery from 12 centers with various treatment planning systems participated. For a complex spinal lesion, the results were compared against a previously published benchmark plan derived for CyberKnife radiosurgery (CKRS) using circular cones only. For two additional cases, one with multiple small lesions infiltrating three vertebrae and a single vertebra lesion treated with integrated boost, the results were compared against a benchmark plan generated using a best practice guideline for CKRS. All plans were rated based on a previously established ranking system. RESULTS: All 12 centers could reach equality (n = 4) or outperform (n = 8) the benchmark plan. For the multiple lesions and the single vertebra lesion plan only 5 and 3 of the 12 centers, respectively, reached equality or outperformed the best practice benchmark plan. However, the absolute differences in target and critical structure dosimetry were small and strongly planner-dependent rather than system-dependent. Overall, gantry-based IMAT with simple planning techniques (two coplanar arcs) produced faster treatments and significantly outperformed static gantry intensity modulated radiation therapy (IMRT) and multileaf collimator (MLC) or non-MLC CKRS treatment plan quality regardless of the system (mean rank out of 4 was 1.2 vs. 3.1, p = 0.002). CONCLUSIONS: High plan quality for complex spinal radiosurgery was achieved among all systems and all participating centers in this planning challenge. This study concludes that simple IMAT techniques can generate significantly better plan quality compared to previous established CKRS benchmarks.


Assuntos
Benchmarking , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral , Vértebras Torácicas , Idoso , Algoritmos , Fracionamento da Dose de Radiação , Humanos , Recidiva Local de Neoplasia/radioterapia , Órgãos em Risco , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Reirradiação , Procedimentos Cirúrgicos Robóticos/instrumentação , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Vértebras Torácicas/cirurgia
6.
J Appl Clin Med Phys ; 17(4): 59-72, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27455475

RESUMO

Radiation Protection in Radiology, Nuclear Medicine and Radio Oncology is of the utmost importance. Radioiodine therapy is a frequently used and effective method for the treatment of thyroid disease. Prior to each therapy the radioactivity of the [131I]-capsule must be determined to prevent misadministration. This leads to a significant radiation exposure to the staff. We describe an alternative method, allowing a considerable reduction of the radiation exposure. Two [131I]-capsules (A01 = 2818.5; A02 = 7355.0 MBq) were measured multiple times in their own delivery lead containers - that is to say, [131I]-capsules remain inside the containers during the measurements (shielded measurement) using a dose calibrator and a well-type and a thyroid uptake probe. The results of the shielded measurements were correlated linearly with the [131I]-capsules radioactivity to create calibration curves for the used devices. Additional radioactivity measurements of 50 [131I]-capsules of different radioactivities were done to validate the shielded measuring method. The personal skin dose rate (HP(0.07)) was determined using calibrated thermo luminescent dosimeters. The determination coefficients for the calibration curves were R2 > 0.9980 for all devices. The relative uncertainty of the shielded measurement was < 6.8%. At a distance of 10 cm from the unshielded capsule the HP(0.07) was 46.18 µSv/(GBq•s), and on the surface of the lead container containing the [131I]-capsule the HP(0.07) was 2.99 and 0.27 µSv/(GBq•s) for the two used container sizes. The calculated reduction of the effective dose by using the shielded measuring method was, depending on the used container size, 74.0% and 97.4%, compared to the measurement of the unshielded [131I]-capsule using a dose calibrator. The measured reduction of the effective radiation dose in the practice was 56.6% and 94.9 for size I and size II containers. The shielded [131I]-capsule measurement reduces the radiation exposure to the staff significantly and offers the same accuracy of the unshielded measurement in the same amount of time. In order to maintain the consistency of the measuring method, monthly tests have to be done by measuring a [131I]-capsule with known radioactivity.


Assuntos
Exposição por Inalação/análise , Radioisótopos do Iodo/análise , Corpo Clínico Hospitalar , Exposição à Radiação/análise , Proteção Radiológica/normas , Radiometria/métodos , Humanos , Radioisótopos do Iodo/uso terapêutico , Doses de Radiação
7.
J Appl Clin Med Phys ; 17(3): 313-330, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167291

RESUMO

Stereotactic radiosurgery (SRS) is the accurate, conformal delivery of high-dose radiation to well-defined targets while minimizing normal structure doses via steep dose gradients. While inverse treatment planning (ITP) with computerized optimization algorithms are routine, many aspects of the planning process remain user-dependent. We performed an international, multi-institutional benchmark trial to study planning variability and to analyze preferable ITP practice for spinal robotic radiosurgery. 10 SRS treatment plans were generated for a complex-shaped spinal metastasis with 21 Gy in 3 fractions and tight constraints for spinal cord (V14Gy < 2 cc, V18Gy < 0.1 cc) and target (coverage > 95%). The resulting plans were rated on a scale from 1 to 4 (excellent-poor) in five categories (constraint compliance, optimization goals, low-dose regions, ITP complexity, and clinical acceptability) by a blinded review panel. Additionally, the plans were mathemati-cally rated based on plan indices (critical structure and target doses, conformity, monitor units, normal tissue complication probability, and treatment time) and compared to the human rankings. The treatment plans and the reviewers' rankings varied substantially among the participating centers. The average mean overall rank was 2.4 (1.2-4.0) and 8/10 plans were rated excellent in at least one category by at least one reviewer. The mathematical rankings agreed with the mean overall human rankings in 9/10 cases pointing toward the possibility for sole mathematical plan quality comparison. The final rankings revealed that a plan with a well-balanced trade-off among all planning objectives was preferred for treatment by most par-ticipants, reviewers, and the mathematical ranking system. Furthermore, this plan was generated with simple planning techniques. Our multi-institutional planning study found wide variability in ITP approaches for spinal robotic radiosurgery. The participants', reviewers', and mathematical match on preferable treatment plans and ITP techniques indicate that agreement on treatment planning and plan quality can be reached for spinal robotic radiosurgery.


Assuntos
Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Robótica/métodos , Neoplasias da Coluna Vertebral/cirurgia , Algoritmos , Benchmarking , Humanos , Agências Internacionais , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
8.
Med Phys ; 51(1): 464-475, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897883

RESUMO

BACKGROUND: Ideally, inverse planning for HDR brachytherapy (BT) should include the pose of the needles which define the trajectory of the source. This would be particularly interesting when considering the additional freedom and accuracy in needle pose which robotic needle placement enables. However, needle insertion typically leads to tissue deformation, resulting in uncertainty regarding the actual pose of the needles with respect to the tissue. PURPOSE: To efficiently address uncertainty during inverse planning for HDR BT in order to robustly optimize the pose of the needles before insertion, that is, to facilitate path planning for robotic needle placement. METHODS: We use a form of stochastic linear programming to model the inverse treatment planning problem. To account for uncertainty, we consider random tissue displacements at the needle tip to simulate tissue deformation. Conventionally for stochastic linear programming, each simulated deformation is reflected by an addition to the linear programming problem which increases problem size and computational complexity substantially and leads to impractical runtime. We propose two efficient approaches for stochastic linear programming. First, we consider averaging dose coefficients to reduce the problem size. Second, we study weighting of the slack variables of an adjusted linear problem to approximate the full stochastic linear program. We compare different approaches to optimize the needle configurations and evaluate their robustness with respect to different amounts of tissue deformation. RESULTS: Our results illustrate that stochastic planning can improve the robustness of the treatment with respect to deformation. The proposed approaches approximating stochastic linear programming better conform to the tissue deformation compared to conventional linear programming. They show good correlation with the plans computed after deformation while reducing the runtime by two orders of magnitude compared to the complete stochastic linear program. Robust optimization of needle configurations takes on average 59.42 s. Skew needle configurations lead to mean coverage improvements compared to parallel needles from 0.39 to 2.94 percentage points, when 8 mm tissue deformation is considered. Considering tissue deformations from 4  to 10 mm during planning with weighted stochastic optimization and skew needles generally results in improved mean coverage from 1.77 to 4.21 percentage points. CONCLUSIONS: We show that efficient stochastic optimization allows selecting needle configurations which are more robust with respect to potentially negative effects of target deformation and displacement on the achievable prescription dose coverage. The approach facilitates robust path planning for robotic needle placement.


Assuntos
Braquiterapia , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Próstata , Neoplasias da Próstata/radioterapia , Braquiterapia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Agulhas
9.
Radiother Oncol ; 193: 110114, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309583

RESUMO

AIM: 106Ru eye plaque brachytherapy (BT, interventional radiotherapy) is an eye-preserving treatment for uveal melanoma performed in about 100 clinics worldwide. Despite this relatively low number, there is a considerable variation in clinical practice. In 2022, the BRAPHYQS and Head & Neck and Skin GEC-ESTRO working groups conducted a survey to map the current clinical practice. The survey consisted of a physicist and a physician part. This paper describes the physicist results. However, three physician questions with overlapping interest are included here as well. MATERIALS AND METHODS: The survey questions pertained to commissioning and quality control (QC) of the plaques, treatment planning, radiobiological correction, as well as more general questions on practice improvement. The questions overlapping with the physician survey were related to dose prescription and margins. RESULTS: Sixty-five physicist responses were included. A majority of the centres do not perform an independent measurement of the absorbed dose at reference depth, percentage depth dose (PDD) and off-axis data. A lack of calibration services and suitable equipment are the main reasons. About one third of the centres indicated that they do image based treatment planning. The use of margins and dose prescription showed a large variability, despite the availability of guidelines [1]. Many respondents expressed a strong wish for improvement in a wide range of aspects of clinical practice. CONCLUSION: The physics survey showed a wide variability regarding quality control of the 106Ru sources and treatment planning practice.


Assuntos
Braquiterapia , Melanoma , Humanos , Melanoma/radioterapia , Dosagem Radioterapêutica , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador , Inquéritos e Questionários
10.
Phys Imaging Radiat Oncol ; 27: 100461, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37720460

RESUMO

Background/Purpose: This study determines and compares the geometric setup errors between stereoscopic x-ray and kilo-voltage cone beam CT (CBCT) in phantom tests on a linear accelerator (linac) for image-guided (IG) stereotactic radiotherapy of intracranial tumors. Additionally, dose-volume metrics in the target volumes of the setup errors of CBCT were evaluated. Materials/Methods: A Winston-Lutz- and an anthropomorphic phantom were used. The mean deviation and root mean square error (RMSE) of CBCT and stereoscopic x-ray were compared. Dose-volume metrics of the planning target volume (PTV) and gross target volume (GTV) for CBCT were calculated. Results: The RMSEs in the tests with the Winston-Lutz-Phantom were 0.3 mm, 1.1 mm and 0.3 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray in the translational dimensions (right-left, anterior-posterior and superior-inferior). The RMSEs in the tests with the anthropomorphic phantom were 0.3 mm, 0.2 mm and 0.1 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray. The effects on dose-volume metrics of the setup errors of CBCT on the GTV were within 1 % for all considered dose values. The effects on the PTV were within 5 % for all considered dose values. Conclusion: Both IG systems provide high accuracy patient positioning within a submillimeter range. The phantom tests exposed a slightly higher accuracy of stereoscopic x-ray than CBCT. The comparison with other studies with a similar purpose emphasizes the importance of individual IG installation quality assurance.

11.
J Contemp Brachytherapy ; 15(3): 220-223, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37425199

RESUMO

Interventional radiotherapy (IRT, brachytherapy) is a highly effective treatment method for non-melanoma skin cancer (NMSC). Traditionally, the maximum depth of NMSC lesions considered eligible for contact IRT was 5 mm; however, following several national surveys and recent recommendations, such cut-off, lesions thicker than 5 mm may be treated by contact IRT. The use of image guidance in defining the actual depth in treating NMSC to correctly identify clinical target volume (CTV) and prevent unnecessary toxicity is of paramount importance. The aim of the paper was to describe a multilayer arrangement of catheters to treat NMSC lesions thicker than 5 mm, thus proposing an example of dynamic intensity modulated IRT, using different catheter-to-skin distance of sources to reach the best CTV coverage and maximally reduce the excess of dose to the skin.

12.
Med Phys ; 50(7): 4675-4687, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37194638

RESUMO

PURPOSE: To provide the first clinical test case for commissioning of 192 Ir brachytherapy model-based dose calculation algorithms (MBDCAs) according to the AAPM TG-186 report workflow. ACQUISITION AND VALIDATION METHODS: A computational patient phantom model was generated from a clinical multi-catheter 192 Ir HDR breast brachytherapy case. Regions of interest (ROIs) were contoured and digitized on the patient CT images and the model was written to a series of DICOM CT images using MATLAB. The model was imported into two commercial treatment planning systems (TPSs) currently incorporating an MBDCA. Identical treatment plans were prepared using a generic 192 Ir HDR source and the TG-43-based algorithm of each TPS. This was followed by dose to medium in medium calculations using the MBDCA option of each TPS. Monte Carlo (MC) simulation was performed in the model using three different codes and information parsed from the treatment plan exported in DICOM radiation therapy (RT) format. Results were found to agree within statistical uncertainty and the dataset with the lowest uncertainty was assigned as the reference MC dose distribution. DATA FORMAT AND USAGE NOTES: The dataset is available online at http://irochouston.mdanderson.org/rpc/BrachySeeds/BrachySeeds/index.html,https://doi.org/10.52519/00005. Files include the treatment plan for each TPS in DICOM RT format, reference MC dose data in RT Dose format, as well as a guide for database users and all files necessary to repeat the MC simulations. POTENTIAL APPLICATIONS: The dataset facilitates the commissioning of brachytherapy MBDCAs using TPS embedded tools and establishes a methodology for the development of future clinical test cases. It is also useful to non-MBDCA adopters for intercomparing MBDCAs and exploring their benefits and limitations, as well as to brachytherapy researchers in need of a dosimetric and/or a DICOM RT information parsing benchmark. Limitations include specificity in terms of radionuclide, source model, clinical scenario, and MBDCA version used for its preparation.


Assuntos
Braquiterapia , Humanos , Dosagem Radioterapêutica , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria , Mama/diagnóstico por imagem , Método de Monte Carlo
13.
Med Phys ; 50(8): e946-e960, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37427750

RESUMO

The introduction of model-based dose calculation algorithms (MBDCAs) in brachytherapy provides an opportunity for a more accurate dose calculation and opens the possibility for novel, innovative treatment modalities. The joint AAPM, ESTRO, and ABG Task Group 186 (TG-186) report provided guidance to early adopters. However, the commissioning aspect of these algorithms was described only in general terms with no quantitative goals. This report, from the Working Group on Model-Based Dose Calculation Algorithms in Brachytherapy, introduced a field-tested approach to MBDCA commissioning. It is based on a set of well-characterized test cases for which reference Monte Carlo (MC) and vendor-specific MBDCA dose distributions are available in a Digital Imaging and Communications in Medicine-Radiotherapy (DICOM-RT) format to the clinical users. The key elements of the TG-186 commissioning workflow are now described in detail, and quantitative goals are provided. This approach leverages the well-known Brachytherapy Source Registry jointly managed by the AAPM and the Imaging and Radiation Oncology Core (IROC) Houston Quality Assurance Center (with associated links at ESTRO) to provide open access to test cases as well as step-by-step user guides. While the current report is limited to the two most widely commercially available MBDCAs and only for 192 Ir-based afterloading brachytherapy at this time, this report establishes a general framework that can easily be extended to other brachytherapy MBDCAs and brachytherapy sources. The AAPM, ESTRO, ABG, and ABS recommend that clinical medical physicists implement the workflow presented in this report to validate both the basic and the advanced dose calculation features of their commercial MBDCAs. Recommendations are also given to vendors to integrate advanced analysis tools into their brachytherapy treatment planning system to facilitate extensive dose comparisons. The use of the test cases for research and educational purposes is further encouraged.


Assuntos
Braquiterapia , Braquiterapia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Relatório de Pesquisa , Método de Monte Carlo , Radiometria
14.
Phys Imaging Radiat Oncol ; 24: 53-58, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36185802

RESUMO

Background and purpose: Risk management in radiotherapy is of high importance. There is not much data published on errors occurring in the treatment planning process of external beam techniques. The aim of this study was to investigate errors occurring during physics plan review in external beam radiotherapy. Materials and methods: Over a period of 14 months errors observed during the physical review process are reported. The errors were grouped and evaluated regarding treatment machine, technique, and treatment site. In addition, a correlation between frequency of errors and staff shortage was analyzed. Results: Subgroups of grave errors (g-errors) and slight errors (s-errors) were defined to consider the different impact on the patient and clinical workflow of the errors. In 1056 plans reviewed, 110 errors (41 g-errors, 69 s-errors) were detected. The most common g-errors and s-errors were "Wrong gantry angle at setup field" (n = 19) and "Wrong field label" (n = 24), respectively. A correlation of number of errors and treatment machine, technique, or anatomical site could not be found. No correlation between staff shortage and number of errors was observed. Conclusions: The process of reviewing treatment plans is a relevant topic to consider in risk analysis of the radiotherapy workflow. The review process could be improved by enhancements in the treatment planning systems, use of digital dose prescription, and treatment planning templates.

15.
Med Phys ; 49(9): 6195-6208, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35925023

RESUMO

PURPOSE: Monte Carlo (MC) simulation studies, aimed at evaluating the magnitude of tissue heterogeneity in 125 I prostate permanent seed implant brachytherapy (BT), customarily use clinical post-implant CT images to generate a virtual representation of a realistic patient model (virtual patient model). Metallic artifact reduction (MAR) techniques and tissue assignment schemes (TAS) are implemented on the post-implant CT images to mollify metallic artifacts due to BT seeds and to assign tissue types to the voxels corresponding to the bright seed spots and streaking artifacts, respectively. The objective of this study is to assess the combined influence of MAR and TAS on MC absorbed dose calculations in post-implant CT-based phantoms. The virtual patient models used for 125 I prostate implant MC absorbed dose calculations in this study are derived from the CT images of an external radiotherapy prostate patient without BT seeds and prostatic calcifications, thus averting the need to implement MAR and TAS. METHODS: The geometry of the IsoSeed I25.S17plus source is validated by comparing the MC calculated results of the TG-43 parameters for the line source approximation with the TG-43U1S2 consensus data. Four MC absorbed dose calculations are performed in two virtual patient models using the egs_brachy MC code: (1) TG-43-based Dw,w-TG 43 , (2) Dw,w-MBDC that accounts for interseed scattering and attenuation (ISA), (3) Dm,m that examines ISA and tissue heterogeneity by scoring absorbed dose in tissue, and (4) Dw,m that unlike Dm,m scores absorbed dose in water. The MC absorbed doses (1) and (2) are simulated in a TG-43 patient phantom derived by assigning the densities of every voxel to 1.00 g cm-3 (water), whereas MC absorbed doses (3) and (4) are scored in the TG-186 patient phantom generated by mapping the mass density of each voxel to tissue according to a CT calibration curve. The MC absorbed doses calculated in this study are compared with VariSeed v8.0 calculated absorbed doses. To evaluate the dosimetric effect of MAR and TAS, the MC absorbed doses of this work (independent of MAR and TAS) are compared to the MC absorbed doses of different 125 I source models from previous studies that were calculated with different MC codes using post-implant CT-based phantoms generated by implementing MAR and TAS on post-implant CT images. RESULTS: The very good agreement of TG-43 parameters of this study and the published consensus data within 3% validates the geometry of the IsoSeed I25.S17plus source. For the clinical studies, the TG-43-based calculations show a D90 overestimation of more than 4% compared to the more realistic MC methods due to ISA and tissue composition. The results of this work generally show few discrepancies with the post-implant CT-based dosimetry studies with respect to the D90 absorbed dose metric parameter. These discrepancies are mainly Type B uncertainties due to the different 125 I source models and MC codes. CONCLUSIONS: The implementation of MAR and TAS on post-implant CT images have no dosimetric effect on the 125 I prostate MC absorbed dose calculation in post-implant CT-based phantoms.


Assuntos
Braquiterapia , Próstata , Artefatos , Braquiterapia/métodos , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Água
16.
Radiother Oncol ; 176: 108-117, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36167195

RESUMO

The vast majority of radiotherapy departments in Europe using brachytherapy (BT) perform temporary implants of high- or pulsed-dose rate (HDR-PDR) sources with photon energies higher than 50 keV. Such techniques are successfully applied to diverse pathologies and clinical scenarios. These recommendations are the result of Working Package 21 (WP-21) initiated within the BRAchytherapy PHYsics Quality Assurance System (BRAPHYQS) GEC-ESTRO working group with a focus on HDR-PDR source calibration. They provide guidance on the calibration of such sources, including practical aspects and issues not specifically accounted for in well-accepted societal recommendations, complementing the BRAPHYQS WP-18 Report dedicated to low energy BT photon emitting sources (seeds). The aim of this report is to provide a European-wide standard in HDR-PDR BT source calibration at the hospital level to maintain high quality patient treatments.


Assuntos
Braquiterapia , Humanos , Braquiterapia/métodos , Dosagem Radioterapêutica , Calibragem , Fótons/uso terapêutico , Hospitais
17.
Radiother Oncol ; 175: 122-132, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36030932

RESUMO

The aim of this publication is the assessment of the existing guidelines for non-melanoma skin cancer (NMSC) superficial brachytherapy (BT) and make a critical review based on the existing literature about the maximum dose prescription depth, bolus thickness and maximum skin surface dose (Dmax) of the published clinical practice. A systematic review of NMSC superficial BT published articles was carried out by the GEC-ESTRO Head & Neck and Skin (HNS) Working Group (WG). 10 members and 2 external reviewers compared the published clinical procedures with the recommendations in the current guidelines and examined the grade of evidence. Our review verified that there is a large variation among centres with regards to clinical practice in superficial BT and identified studies where published parameters such as maximum dose prescription depth, bolus thickness and Dmax exceed the constraints recommended in the guidelines, while showing excellent results in terms of local control, toxicity and cosmesis. This review confirmed that current recommendations on skin superficial BT do not include published experience on tumours treated with superficial BT that require dose prescription depth beyond the recommended 5 mm under the skin surface and that the existing literature does not provide sufficient evidence to relate dosimetry of superficial BT to patient reported outcome measures. The GEC-ESTRO HNS WG considers acceptable to prescribe superficial BT dose at a depth above 5 mm beyond the skin surface, and modify the bolus thickness to optimize the treatment plan and adjust the acceptable maximum dose on the skin surface, all pending clinical situation.


Assuntos
Braquiterapia , Neoplasias Cutâneas , Humanos , Braquiterapia/métodos , Neoplasias Cutâneas/radioterapia , Radiometria , Prescrições , Dosagem Radioterapêutica
18.
Int J Radiat Oncol Biol Phys ; 114(2): 360-372, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35716847

RESUMO

PURPOSE: Cardiac radioablation is a novel treatment option for patients with refractory ventricular tachycardia unsuitable for catheter ablation. The quality of treatment planning depends on dose specifications, platform capabilities, and experience of the treating staff. To harmonize the treatment planning, benchmarking of this process is necessary for multicenter clinical studies such as the RAdiosurgery for VENtricular TAchycardia trial. METHODS AND MATERIALS: Planning computed tomography data and consensus structures from 3 patients were sent to 5 academic centers for independent plan development using a variety of platforms and techniques with the RAdiosurgery for VENtricular TAchycardia study protocol serving as guideline. Three-dimensional dose distributions and treatment plan details were collected and analyzed. In addition, an objective relative plan quality ranking system for ventricular tachycardia treatments was established. RESULTS: For each case, 3 coplanar volumetric modulated arc (VMAT) plans for C-arm linear accelerators (LINAC) and 3 noncoplanar treatment plans for robotic arm LINAC were generated. All plans were suitable for clinical applications with minor deviations from study guidelines in most centers. Eleven of 18 treatment plans showed maximal one minor deviation each for target and cardiac substructures. However, dose-volume histograms showed substantial differences: in one case, the planning target volume ≥30 Gy ranged from 0.0% to 79.9% and the ramus interventricularis anterior V14Gy ranged from 4.0% to 45.4%. Overall, the VMAT plans had steeper dose gradients in the high-dose region, while the plans for the robotic arm LINAC had smaller low-dose regions. Thereby, VMAT plans required only about half as many monitor units, resulting in shorter delivery times, possibly an important factor in treatment outcome. CONCLUSIONS: Cardiac radioablation is feasible with robotic arm and C-arm LINAC systems with comparable plan quality. Although cross-center training and best practice guidelines have been provided, further recommendations, especially for cardiac substructures, and ranking of dose guidelines will be helpful to optimize cardiac radioablation outcomes.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Taquicardia Ventricular , Benchmarking , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia
19.
Cancers (Basel) ; 13(4)2021 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-33671552

RESUMO

The use of brachytherapy (interventional radiotherapy) in the treatment of gynecological cancers is a crucial element in both definitive and adjuvant settings. The recent developments in high-dose rate remote afterloaders, modern applicators, treatment-planning software, image guidance, and dose monitoring systems have led to improvement in the local control rates and in some cases improved the survival rates. The development of these highly advanced and complicated treatment modalities has been accompanied by challenges, which have made the existence of quality assurance protocols a must to ensure the integrity of the treatment process. Quality assurance aims at standardizing the technical and clinical procedures involved in the treatment of patients, which could eventually decrease the source of uncertainties whether technical (source/equipment related) or clinical. This commentary review sheds light (from a clinical point of view) on some potential sources of uncertainties associated with the use of modern brachytherapy in the treatment of gynecological cancers.

20.
Phys Imaging Radiat Oncol ; 19: 108-111, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34401536

RESUMO

BACKGROUND AND PURPOSE: Brachytherapy treatment outcomes depend on the accuracy of the delivered dose distribution, which is proportional to the reference air-kerma rate (RAKR). Current societal recommendations require the medical physicist to compare the measured RAKR values to the manufacturer source calibration certificate. The purpose of this work was to report agreement observed in current clinical practice in the European Union. MATERIALS AND METHODS: A European survey was performed for high- and pulsed-dose-rate (HDR and PDR) high-energy sources (192Ir and 60Co), to quantify observed RAKR differences. Medical physicists at eighteen hospitals from eight European countries were contacted, providing 1,032 data points from 2001 to 2020. RESULTS: Over the survey period, 77% of the 192Ir measurements used a well chamber instead of the older Krieger phantom method. Mean differences with the manufacturer calibration certificate were 0.01% ± 1.15% for 192Ir and -0.1% ± 1.3% for 60Co. Over 95% of RAKR measurements in the clinic were within 3% of the manufacturer calibration certificate. CONCLUSIONS: This study showed that the agreement level was generally better than that reflected in prior societal recommendations positing 5%. Future recommendations on high-energy HDR and PDR source calibrations in the clinic may consider tightened agreements levels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA