Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Tipo de estudo
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Surg Neurol Int ; 11: 329, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33194263

RESUMO

BACKGROUND: Angioplasty using a carotid stent is a treatment modality for carotid stenosis, with results similar to those obtained with endarterectomy, as demonstrated by important studies. The increasing use of this procedure has also led to a larger number of reports of complications, stent fractures among those. Stent fracture is a rare manifestation and hence needs further studying so that its actual prevalence can be determined, as well as its associated risk factors and proper clinical management. The current study reports the case of a patient who had previously undergone angioplasty with a carotid stent and, after an automobile accident, presented with a stent fracture and distal embolization of fragments thereof with neurological manifestation. CASE DESCRIPTION: A male patient, 40 years old, presented with a history of previously stent carotid angioplasty. He had been involved in an automobile accident and suffered a stent fracture with distal fragment migration. As he was an asymptomatic patient (NIHSS 0, Rankin zero), we opted for a conservative treatment with oral anticoagulant. CONCLUSION: Angioplasty is an effective treatment for extracranial atherosclerosis and, albeit rare, stent fractures can result in the migration of fragments thereof. This occurrence should be suspected in patients who have sustained severe neck injuries due to sudden deceleration and may be associated with thromboembolism.

2.
Hig. aliment ; 30(262/263): 85-88, 30/12/2016.
Artigo em Português | LILACS | ID: biblio-831848

RESUMO

A qualidade da higienização industrial deve ser avaliada considerando- -se, entre outros aspectos, o risco que a contaminação alimentar representa para a saúde pública. Este trabalho buscou avaliar as condições higienicossanitárias de superfícies de 25 uniformes de frigorífico, por meio de análise microbiológica para micro-organismos mesófilos aeróbios (UFC/ cm²), conforme a técnica recomendada swab test, avaliando a eficiência do processo de lavagem dos uniformes. Observou-se que 4% das superfícies dos uniformes apresentaram contagens abaixo ou igual 4,0 x100 UFC/ cm², demonstrando condições higiênicas satisfatórias e indicando eficiência nas técnicas de higienização dos uniformes, portanto, não representando riscos de contaminação cruzada através dos uniformes. Tais achados demonstraram que o processo de higienização dos uniformes realizado pelo frigorífico é eficiente e eficaz na redução da carga microbiana, comprovando as boas condições higienicossanitárias dos mesmos.


Assuntos
Humanos , Vestuário/normas , Matadouros/normas , Indústria da Carne , Desinfecção/métodos , Higiene , /prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA