Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 310
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38685482

RESUMO

BACKGROUND: There is insufficient systematized evidence on the effectiveness of individual intranasal medications in allergic rhinitis (AR). OBJECTIVES: We sought to perform a systematic review to compare the efficacy of individual intranasal corticosteroids and antihistamines against placebo in improving the nasal and ocular symptoms and the rhinoconjunctivitis-related quality of life of patients with perennial or seasonal AR. METHODS: The investigators searched 4 electronic bibliographic databases and 3 clinical trials databases for randomized controlled trials (1) assessing adult patients with seasonal or perennial AR and (2) comparing the use of intranasal corticosteroids or antihistamines versus placebo. Assessed outcomes included the Total Nasal Symptom Score, the Total Ocular Symptom Score, and the Rhinoconjunctivitis Quality-of-Life Questionnaire. The investigators performed random-effects meta-analyses of mean differences for each medication and outcome. The investigators assessed evidence certainty using the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach. RESULTS: This review included 151 primary studies, most of which assessed patients with seasonal AR and displayed unclear or high risk of bias. Both in perennial and seasonal AR, most assessed treatments were more effective than placebo. In seasonal AR, azelastine-fluticasone, fluticasone furoate, and fluticasone propionate were the medications with the highest probability of resulting in moderate or large improvements in the Total Nasal Symptom Score and Rhinoconjunctivitis Quality-of-Life Questionnaire. Azelastine-fluticasone displayed the highest probability of resulting in moderate or large improvements of Total Ocular Symptom Score. Overall, evidence certainty was considered "high" in 6 of 46 analyses, "moderate" in 23 of 46 analyses, and "low"/"very low" in 17 of 46 analyses. CONCLUSIONS: Most intranasal medications are effective in improving rhinitis symptoms and quality of life. However, there are relevant differences in the associated evidence certainty.

2.
Trends Biochem Sci ; 45(7): 604-618, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32386890

RESUMO

Proteases play a pivotal role in several biological processes, from digestion, cell proliferation, and differentiation to fertility. Deregulation of protease metabolism can result in several pathological conditions (i.e., cancer, neurodegenerative disorders, and others). Therefore, monitoring proteolytic activity in real time could have a fundamental role in the early diagnosis of these diseases. Herein, the main approaches used to develop biosensors for monitoring proteolytic activity are reviewed. A comparison of the advantages and disadvantages of each approach is provided along with a discussion of their importance and promising opportunities for the early diagnosis of severe diseases. This new era of biosensors can be characterized by the ability to control and monitor biological processes, ultimately improving the potential of personalized medicine.


Assuntos
Técnicas Biossensoriais , Humanos , Peptídeo Hidrolases/metabolismo , Medicina de Precisão , Proteólise
3.
Neurobiol Dis ; 195: 106500, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38614275

RESUMO

Spinal Cord Injury (SCI) disrupts critical autonomic pathways responsible for the regulation of the immune function. Consequently, individuals with SCI often exhibit a spectrum of immune dysfunctions ranging from the development of damaging pro-inflammatory responses to severe immunosuppression. Thus, it is imperative to gain a more comprehensive understanding of the extent and mechanisms through which SCI-induced autonomic dysfunction influences the immune response. In this review, we provide an overview of the anatomical organization and physiology of the autonomic nervous system (ANS), elucidating how SCI impacts its function, with a particular focus on lymphoid organs and immune activity. We highlight recent advances in understanding how intraspinal plasticity that follows SCI may contribute to aberrant autonomic activity in lymphoid organs. Additionally, we discuss how sympathetic mediators released by these neuron terminals affect immune cell function. Finally, we discuss emerging innovative technologies and potential clinical interventions targeting the ANS as a strategy to restore the normal regulation of the immune response in individuals with SCI.


Assuntos
Vias Autônomas , Traumatismos da Medula Espinal , Traumatismos da Medula Espinal/imunologia , Traumatismos da Medula Espinal/fisiopatologia , Humanos , Animais , Vias Autônomas/imunologia , Sistema Nervoso Autônomo/fisiopatologia , Sistema Nervoso Autônomo/imunologia
4.
Magn Reson Med ; 92(2): 741-750, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38523462

RESUMO

PURPOSE: To develop an open-source prototype of myocardial T1 mapping (Open-MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open-MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter-scanner and cross-vendor reproducibility studies. METHODS: Open-MOLLI is an inversion-recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open-MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open-MOLLI and MOLLI were repeated in the same session (test-retest). RESULTS: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1vial3 = 1027 ms): T1MOLLI = 1011 ± 24 ms versus T1Open-MOLLI = 1009 ± 20 ms. In vivo T1 estimates were similar between Open-MOLLI and MOLLI (T1MOLLI = 1004 ± 33 ms vs. T1Open-MOLLI = 998 ± 52 ms), with a mean difference of -17 ms (p = 0.20), despite noisier Open-MOLLI weighted images and maps. Repeatability measures were slightly higher for Open-MOLLI (RCMOLLI = 3.0% vs. RCOpen-MOLLI = 4.4%). CONCLUSION: The open-source sequence Open-MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open-MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.


Assuntos
Imagens de Fantasmas , Humanos , Reprodutibilidade dos Testes , Adulto , Masculino , Feminino , Algoritmos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto Jovem , Miocárdio
5.
Br J Clin Pharmacol ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38970469

RESUMO

AIMS: Dopamine beta-hydroxylase (DßH) inhibitors, like zamicastat, hold promise for treating pulmonary arterial hypertension. This study aimed to validate the mechanism of action of zamicastat by studying its effect on the overdrive of the sympathetic nervous system (SNS). METHODS: A single-centre, prospective, double-blind, randomized, placebo-controlled, crossover study evaluated the effect of 400 mg zamicastat in 22 healthy male subjects. Cold pressor test (CPT) was performed at screening and each treatment period on Days -1 and 10. Plasma and 24 h-urine levels of dopamine (DA), epinephrine (EPI) and norepinephrine (NE), and plasma DßH activity, were measured. RESULTS: Compared to placebo, zamicastat showed a - 4.62 mmHg decrease in systolic blood pressure during the cold stimulus vs. rest phases on Day 10 of CPT (P = .020). Zamicastat decreased mean arterial pressure response to cold stimulus during CPT (-2.62 mmHg; P = .025). At Day 10, zamicastat significantly increased plasma DA, before CPT (12.63 ng/L; P = .040) and after CPT (19.22 ng/L; P = .001) as well as the estimated plasma EPI change from baseline after CPT (P = .040). Inhibition of plasma DßH activity ranged from 19.8% to 25.0%. At Day 10, significant reductions in 24-h urinary excretion of EPI (P = .002) and NE (P = .001) were observed. Zamicastat Cτ geometric mean ± GSD ranged from 45.86 ± 1.46 ng/mL on Day 3 to 58.64 ± 1.52 ng/mL on Day 10, with moderate inter-individual variability (CV: 32.6%-36.6%). Steady state was already achieved on Day 6. CONCLUSIONS: Our results demonstrated the effect of zamicastat on the overdrive sympathetic response to cold stimulus, confirming its potential as SNS modulator.

6.
Pain Med ; 25(1): 8-12, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37656943

RESUMO

OBJECTIVES: To describe and assess the feasibility of an ultrasound-guided technique for intra-articular injection of the costovertebral joints, in an unembalmed cadaveric specimen, utilizing fluoroscopy and cone beam computerized tomography for confirmation of contrast spread and needle tip position, respectively. METHODOLOGY: A single unembalmed cadaveric specimen was obtained. A single interventionist performed the placement of the needles under ultrasound guidance. Contrast dye was then injected through each of the needles under real-time fluoroscopy. Finally, the specimen was submitted to a cone beam computerized tomography with 3-dimensional acquisition and multiplanar reformatting to assess final needle tip position relative to the costovertebral joints. RESULTS: In total, 18 spinal needles were placed under ultrasound guidance. Fluoroscopy showed 4 distinct patterns of contrast spread: intra-articular in the costovertebral joint (13 levels in total), epidural (1 level), intra-articular in the facet joint of the target level (3 levels), and undetermined (1 level). Cone-beam computerized tomography confirmed 13 out of 18 needles to be adequately placed in the costovertebral joints (72% of the total) and 5 out of the 18 needles to be misplaced: 3 needles were placed in the facet joint of the target level, and 2 needles were placed in the epidural space. CONCLUSIONS: This study suggests that, when performed by experienced interventionists, this technique has an accuracy rate of 72%. Further studies are warranted before these results can be extrapolated to daily clinical practice.


Assuntos
Agulhas , Ultrassonografia de Intervenção , Humanos , Estudos de Viabilidade , Ultrassonografia de Intervenção/métodos , Tomografia Computadorizada por Raios X , Fluoroscopia/métodos , Cadáver
7.
MAGMA ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38393541

RESUMO

OBJECTIVE: Diffusional kurtosis imaging (DKI) extends diffusion tensor imaging (DTI), characterizing non-Gaussian diffusion effects but requires longer acquisition times. To ensure the robustness of DKI parameters, data acquisition ordering should be optimized allowing for scan interruptions or shortening. Three methodologies were used to examine how reduced diffusion MRI scans impact DKI histogram-metrics: 1) the electrostatic repulsion model (OptEEM); 2) spherical codes (OptSC); 3) random (RandomTRUNC). MATERIALS AND METHODS: Pre-acquired diffusion multi-shell data from 14 female healthy volunteers (29±5 years) were used to generate reordered data. For each strategy, subsets containing different amounts of the full dataset were generated. The subsampling effects were assessed on histogram-based DKI metrics from tract-based spatial statistics (TBSS) skeletonized maps. To evaluate each subsampling method on simulated data at different SNRs and the influence of subsampling on in vivo data, we used a 3-way and 2-way repeated measures ANOVA, respectively. RESULTS: Simulations showed that subsampling had different effects depending on DKI parameter, with fractional anisotropy the most stable (up to 5% error) and radial kurtosis the least stable (up to 26% error). RandomTRUNC performed the worst while the others showed comparable results. Furthermore, the impact of subsampling varied across distinct histogram characteristics, the peak value the least affected (OptEEM: up to 5% error; OptSC: up to 7% error) and peak height (OptEEM: up to 8% error; OptSC: up to 11% error) the most affected. CONCLUSION: The impact of truncation depends on specific histogram-based DKI metrics. The use of a strategy for optimizing the acquisition order is advisable to improve DKI robustness to exam interruptions.

8.
BMC Med Inform Decis Mak ; 24(1): 95, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622703

RESUMO

This study presents a workflow for identifying and characterizing patients with Heart Failure (HF) and multimorbidity utilizing data from Electronic Health Records. Multimorbidity, the co-occurrence of two or more chronic conditions, poses a significant challenge on healthcare systems. Nonetheless, understanding of patients with multimorbidity, including the most common disease interactions, risk factors, and treatment responses, remains limited, particularly for complex and heterogeneous conditions like HF. We conducted a clustering analysis of 3745 HF patients using demographics, comorbidities, laboratory values, and drug prescriptions. Our analysis revealed four distinct clusters with significant differences in multimorbidity profiles showing differential prognostic implications regarding unplanned hospital admissions. These findings underscore the considerable disease heterogeneity within HF patients and emphasize the potential for improved characterization of patient subgroups for clinical risk stratification through the use of EHR data.


Assuntos
Insuficiência Cardíaca , Multimorbidade , Humanos , Comorbidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Análise por Conglomerados , Doença Crônica
9.
Sensors (Basel) ; 24(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38894317

RESUMO

Over the past two decades, there has been extensive research into surveillance methods for the post-endovascular repair of abdominal aortic aneurysms, highlighting the importance of these technologies in supplementing or even replacing conventional image-screening modalities. This review aims to provide an overview of the current status of alternative surveillance solutions for endovascular aneurysm repair, while also identifying potential aneurysm features that could be used to develop novel monitoring technologies. It offers a comprehensive review of these recent clinical advances, comparing new and standard clinical practices. After introducing the clinical understanding of abdominal aortic aneurysms and exploring current treatment procedures, the paper discusses the current surveillance methods for endovascular repair, contrasting them with recent pressure-sensing technologies. The literature on three commercial pressure-sensing devices for post-endovascular repair surveillance is analyzed. Various pre-clinical and clinical studies assessing the safety and efficacy of these devices are reviewed, providing a comparative summary of their outcomes. The review of the results from pre-clinical and clinical studies suggests a consistent trend of decreased blood pressure in the excluded aneurysm sac post-repair. However, despite successful pressure readings from the aneurysm sac, no strong link has been established to translate these measurements into the presence or absence of endoleaks. Furthermore, the results do not allow for a conclusive determination of ongoing aneurysm sac growth. Consequently, a strong clinical need persists for monitoring endoleaks and aneurysm growth following endovascular repair.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Pressão Sanguínea/fisiologia , Pressão , Próteses e Implantes , Correção Endovascular de Aneurisma
10.
Sensors (Basel) ; 24(10)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38794049

RESUMO

Abdominal aortic aneurysm (AAA) is a dilation of the aorta artery larger than its normal diameter (>3 cm). Endovascular aneurysm repair (EVAR) is a minimally invasive treatment option that involves the placement of a graft in the aneurysmal portion of the aorta artery. This treatment requires multiple follow-ups with medical imaging, which is expensive, time-consuming, and resource-demanding for healthcare systems. An alternative solution is the use of wireless implantable sensors (WIMSs) to monitor the growth of the aneurysm. A WIMS capable of monitoring aneurysm size longitudinally could serve as an alternative monitoring approach for post-EVAR patients. This study has developed and characterised a three-coil inductive read-out system to detect variations in the resonance frequency of the novel Z-shaped WIMS implanted within the AAA sac. Specifically, the spacing between the transmitter and the repeater inductors was optimised to maximise the detection of the sensor by the transmitter inductor. Moreover, an experimental evaluation was also performed for different orientations of the transmitter coil with reference to the WIMS. Finally, the FDA-approved material nitinol was used to develop the WIMS, the transmitter, and repeater inductors as a proof of concept for further studies. The findings of the characterisation from the air medium suggest that the read-out system can detect the WIMS up to 5 cm, regardless of the orientation of the Z-shape WIMS, with the detection range increasing as the orientation approaches 0°. This study provides sufficient evidence that the proposed WIMS and the read-out system can be used for AAA expansion over time.


Assuntos
Aneurisma da Aorta Abdominal , Tecnologia sem Fio , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tecnologia sem Fio/instrumentação , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Próteses e Implantes , Desenho de Equipamento
11.
Pain Pract ; 24(4): 677-685, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38170566

RESUMO

INTRODUCTION: Persistent pain following breast surgery is common and may be challenging to treat. In patients refractory to conservative treatments, ultrasound-guided fascial plane blocks of thoracic nerves can be a useful option. RESULTS: This type of neuro blockade technique provides advantages in terms of safety and efficacy that are convenient for physicians managing refractory and complex cases of post-breast surgery syndrome. CONCLUSION: This technical review aims to present an up-to-date summary of the most common ultrasound-guided fascial plane blocks for chronic pain in post-breast surgery patients, provide a detailed technical description of each intervention, and propose preferred injections based on the anatomical location of the pain.


Assuntos
Neoplasias da Mama , Bloqueio Nervoso , Nervos Torácicos , Humanos , Feminino , Bloqueio Nervoso/métodos , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/terapia , Ultrassonografia de Intervenção/métodos
12.
Magn Reson Med ; 90(2): 539-551, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37036367

RESUMO

PURPOSE: Enabling fast and accessible myocardial T1 mapping is crucial for extending its clinical application. We introduce Open-MOLLI-SMS combining simultaneous multi-slice (SMS) with auto-calibration and variable-rate selective excitation (VERSE)-multiband pulses to obtain all slices in a fast single-shot T1 mapping sequence. METHODS: Open-MOLLI-SMS was developed by integrating SMS with the open-source method Open-MOLLI previously implemented in Pulseq. Three methods were integrated for Open-MOLLI-SMS: (1) auto-calibration blip patterns to ensure consistency between the data and coil information; (2) a blipped-balanced SSFP (bSSFP) readout to induce controlled aliasing in parallel imaging shifts without disturbing the bSSFP frequency response; and (3) a VERSE-multiband pulse for minimizing the achievable TR and the specific absortion rate (SAR) impact of SMS. Two (SMS2) or three (SMS3) slices were excited simultaneously and encoded with an in-plane acceleration factor of 2. Experiments were performed in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom and five healthy volunteers. RESULTS: Phantom results show accurate T1 estimates for reference values between 400 to 2200 ms. Artifacts were visible for Open-MOLLI-SMS3 but not replicated in vivo. In vivo Open-MOLLI-SMS (T1 SMS2 = 993 ± 10 ms; T1 SMS3 = 1031 ± 17 ms) provided similar values to mean T1 single-band Open-MOLLI estimates (T1 Open-MOLLI = 1005 ± 47 ms). Open-MOLLI-SMS2 provided the closest estimates to the reference. CONCLUSION: This proof-of-principle implementation study demonstrates the feasibility of speeding up T1 -mapping acquisitions and increasing coverage by combining auto-calibration strategies with a blipped-bSFFP readout and VERSE multiband RF excitation pulses. The proposed methodology was built on the Open-MOLLI mapping sequence, which provides a fast means for prototyping and enables open-source sharing of the method.


Assuntos
Interpretação de Imagem Assistida por Computador , Miocárdio , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Aceleração , Reprodutibilidade dos Testes , Coração/diagnóstico por imagem
13.
Int J Hyperthermia ; 40(1): 2207797, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37196995

RESUMO

BACKGROUND: Phantoms accurately mimicking the electromagnetic and thermal properties of human tissues are essential for the development, characterization, and quality assurance (QA) of clinically used equipment for Hyperthermia Treatment (HT). Currently, a viable recipe for a fat equivalent phantom is not available, mainly due to challenges in the fabrication process and fast deterioration. MATERIALS AND METHODS: We propose to employ a glycerol-in-oil emulsion stabilized with ethylcellulose to develop a fat-mimicking material. The dielectric, rheological, and thermal properties of the phantom have been assessed by state-of-the-art measurement techniques. The full-size phantom was then verified in compliance with QA guidelines for superficial HT, both numerically and experimentally, considering the properties variability. RESULTS: Dielectric and thermal properties were proven equivalent to fat tissue, with an acceptable variability, in the 8 MHz to 1 GHz range. The rheology measurements highlighted enhanced mechanical stability over a large temperature range. Both numerical and experimental evaluations proved the suitability of the phantom for QA procedures. The impact of the dielectric property variations on the temperature distribution has been numerically proven to be limited (around 5%), even if higher for capacitive devices (up to 20%). CONCLUSIONS: The proposed fat-mimicking phantom is a good candidate for hyperthermia technology assessment processes, adequately representing both dielectric and thermal properties of the human fat tissue while maintaining structural stability even at elevated temperatures. However, further experimental investigations on capacitive heating devices are necessary to better assess the impact of the low electrical conductivity values on the thermal distribution.


Assuntos
Hipertermia Induzida , Humanos , Hipertermia Induzida/métodos , Imagens de Fantasmas , Temperatura , Celulose
14.
BMC Geriatr ; 23(1): 853, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38097933

RESUMO

BACKGROUND: The benefits of physical activity (PA) and adequate sleep are well documented, and their importance strengthens with the increasing prevalence of chronic diseases and multimorbidity (MM). Interventions to promote physical activity and sleep that use commercial activity trackers may be useful non-pharmacological approaches to managing individual health; however, limited evidence exists on their use to improve physical activity in older adult patients with MM. METHODS: This study aims to measure the effects of behavioral change techniques (BCTs) delivered by a wearable device on physical activity and quality of sleep (QS) in older adult patients with MM. We designed an open-label randomized controlled trial with participants recruited through primary care and a specialist outpatient clinic. Participants must be more than 65 years old, have MM, and have access to smartphones. All eligible participants will receive PA promotion content and will be randomly assigned to wear a smartwatch. The primary outcome will be the participants' PA measurement at baseline and at six months using the International Physical Activity Questionnaire - Short Form (IPAQ-SF). Secondary outcomes will include changes in the participants' frailty status, biometric measurements, quality of life, and biopsychosocial assessments. A sample size of 40 participants per arm was calculated to detect group differences, with 50 participants planned to recruit and randomize into each arm. DISCUSSION: This study aims to contribute to a better understanding of PA patterns and the impact of wearable-based PA interventions in patients with MM. In addition, we aim to contribute to more knowledge about the relationship between PA patterns, Patient Reported Outcomes Measures (PROMs), and healthcare resource utilization in patients with MM. To achieve this, the study will leverage a locally developed PROMs registry and assess data from participants' medical records, in order to understand the added impact of wearable data and medical information data on predicting PROMs and unplanned hospital admissions. TRIAL REGISTRATION: NCT05777291.


Assuntos
Multimorbidade , Dispositivos Eletrônicos Vestíveis , Humanos , Idoso , Qualidade de Vida/psicologia , Exercício Físico/psicologia , Sono , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
J Gambl Stud ; 39(3): 1099-1110, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35921003

RESUMO

Scratch cards-otherwise known as scratch tickets or instant lotteries-are a highly accessible type of lottery, due to its relative accessibility and affordability. In Portugal, the popularity of scratch cards has experienced substantial growth, with almost no regulatory reaction whatsoever. This study aims to describe the sociodemographic characteristics of scratch card gamblers, prevalent gambling habits, and their perceptions regarding scratch card gambling. This study also determines the constancy of pathological scratch card gambling, and the possible impact of regulatory measures. We found that about half of the participants studied were at risk of pathological gambling and scratch cards seem to have a clear potential for enticing higher spending in vulnerable consumers, compared to other forms of gambling games. Perception biases regarding gambling are frequent and almost no one afflicted seeks help. Regulatory measures are crucial to regulate potential problematic behaviors, specifically in high-risk persons. There is an urgent need to act, made clear by both present findings and numerous precedent warnings regarding scratch card gambling hazards.


Assuntos
Comportamento Aditivo , Jogo de Azar , Humanos , Jogo de Azar/psicologia , Viés , Inquéritos e Questionários , Portugal
16.
Sensors (Basel) ; 23(22)2023 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-38005520

RESUMO

Evaluating the efficiency of surface treatments is a problem of paramount importance for the cork stopper industry. Generically, these treatments create coatings that aim to enhance the impermeability and lubrification of cork stoppers. Yet, current methods of surface analysis are typically time-consuming, destructive, have poor representativity or rely on indirect approaches. In this work, the use of a laser-induced breakdown spectroscopy (LIBS) imaging solution is explored for evaluating the presence of coating along the cylindrical surface and in depth. To test it, several cork stoppers with different shaped areas of untreated surface were analyzed by LIBS, making a rectangular grid of spots with multiple shots per spot, to try to identify the correspondent shape. Results show that this technique can detect the untreated area along with other features, such as leakage and holes, allowing for a high success rate of identification and for its performance at different depths, paving the way for future industry-grade quality control solutions with more complex surface analysis.

17.
Int J Mol Sci ; 24(9)2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37175391

RESUMO

The regional heterogeneity of microglia was first described a century ago by Pio del Rio Hortega. Currently, new information on microglia heterogeneity throughout central nervous system (CNS) regions is being revealed by high-throughput techniques. It remains unclear whether these spatial specificities translate into different microglial behaviors in vitro. We cultured microglia isolated from the cortex and spinal cord and analyzed the effect of the CNS spatial source on behavior in vitro by applying the same experimental protocol and culture conditions. We analyzed the microglial cell numbers, function, and morphology and found a distinctive in vitro phenotype. We found that microglia were present in higher numbers in the spinal-cord-derived glial cultures, presenting different expressions of inflammatory genes and a lower phagocytosis rate under basal conditions or after activation with LPS and IFN-γ. Morphologically, the cortical microglial cells were more complex and presented longer ramifications, which were also observed in vivo in CX3CR1+/GFP transgenic reporter mice. Collectively, our data demonstrated that microglial behavior in vitro is defined according to specific spatial characteristics acquired by the tissue. Thus, our study highlights the importance of microglia as a source of CNS for in vitro studies.


Assuntos
Sistema Nervoso Central , Microglia , Animais , Camundongos , Microglia/metabolismo , Neuroglia , Medula Espinal , Fagocitose/fisiologia , Camundongos Transgênicos
18.
Opt Express ; 30(5): 6907-6920, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35299465

RESUMO

Long-term quantum key distribution (QKD) using polarization encoding requires a random drift compensation method. We propose a method to compensate any state of polarization based on the quantum bit error rate (QBER) of two states from two non-orthogonal mutually unbiased bases. The proposed method does not require dedicated equipment, and through a simple but highly efficient feedback loop it compensates the polarization random drift suffered by photons while transmitted over the optical fiber quantum channel. A QBER lower than 2% was observed even considering imperfect single photon detectors. Besides, we verify a 82% secret key rate generation improvement in a finite-key size BB84 implementation for a 40 km fiber-optics quantum channel.

19.
Opt Lett ; 47(15): 3948-3951, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35913355

RESUMO

In this Letter we present a discrete modulated, continuous variables quantum key distribution implementation using two probabilistically shaped, 128-symbol, amplitude and phase shift keying constellations. At Bob's detection side, a polarization diverse, true heterodyne receiver architecture is implemented for symbol recovery. We demonstrate experimentally that our system is capable of achieving security against collective attacks, while using accessible, telecom-grade material, and of functioning for an indefinitely long period of time at distances in excess of 185 km, in the asymptotic regime.

20.
J Nucl Cardiol ; 29(4): 1846-1854, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33826127

RESUMO

BACKGROUND: Fluorine-18 sodium fluoride (Na[18F]F) atherosclerotic plaque uptake in positron emission tomography with computed tomography (PET-CT) identifies active microcalcification. We aim to evaluate global cardiac microcalcification activity with Na[18F]F, as a measure of unstable microcalcification burden, in high cardiovascular (CV) risk patients. METHODS AND RESULTS: Thirty-four high CV risk individuals without previous CV events were scanned with Na[18F]F PET-CT. Cardiac Na[18F]F uptake was assessed through the global molecular calcium score (GMCS), which was calculated by summing the product of the mean standardized uptake value times the area of the cardiac regions of interest times the slice thickness for all cardiac transaxial slices, divided by the total number of slices. Mean age is 63.5 ± 7.8 years and 62% male. Median GMCS is 320.9 (240.8-402.8). Individuals with more than five CV risk factors (50%) have increased GMCS [356.7 (321.0-409.6) vs. 261.1 (225.6-342.1), P = 0.01], which is positively correlated with predicted fatal CV risk by SCORE (rs = 0.32, P = 0.04). There is a positive correlation between GMCS and weight (rs = 0.61), body mass index (rs = 0.66), abdominal perimeter (rs = 0.74), thoracic fat volume (rs = 0.47), and epicardial adipose tissue (rs = 0.41), all with P ≤ 0.01. There is no correlation between GMCS and coronary calcium score nor coronary artery wall Na[18F]F uptake. CONCLUSIONS: In a high CV risk group, the global cardiac microcalcification burden is related to CV risk factors, metabolic syndrome variables and cardiac fat. Cardiac GMCS is a promising risk stratification tool, combining a straightforward and objective methodology with a comprehensive analysis of both coronary and valvular microcalcification.


Assuntos
Calcinose , Doenças Cardiovasculares , Placa Aterosclerótica , Idoso , Calcinose/diagnóstico por imagem , Cálcio , Doenças Cardiovasculares/diagnóstico por imagem , Feminino , Radioisótopos de Flúor , Fatores de Risco de Doenças Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Fatores de Risco , Fluoreto de Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA