RESUMO
OBJECTIVE: Synthetic adhesives are used by various medical specialties, especially in surgery; however, studies reporting their use in orthopedic practice are scarce. The aim of this study was to compare the results in using ethyl-2-cyanoacrylate or butyl-2-cyanoacrylate in the treatment of fractures in rats. METHODS: This was an experimental prospective controlled study in 90 rats, with humerus, femur, and tibia fractures, treated with ethyl-2-cyanoacrylate (SB group; n = 45) or butyl-2-cyanoacrylate (HA group; n = 45). Biomechanical and histomorphometric analyses were performed at three different moments (60, 120, and 180 days); besides a clinical study performed weekly by measurement of the animals body mass. RESULTS: No differences were observed regarding body mass (p = 0.07). In both groups, there were no significant differences regarding maximum load (p = 0.6), yield point strength (p = 0.6), and stiffness coefficient (p = 0.4) of the femurs. The same was observed in tibias for maximum load (p = 0.4), yield point strength (p = 0.7), and stiffness coefficient (p = 0.6). The humerus from both groups had similar bone callus area (p = 0.66). In both groups, there were no statistical differences related to inflammatory cells (p = 0.4), osteoblasts (p = 0.2), and osteoclasts (p = 0.2). CONCLUSION: Ethyl-2-cyanoacrylate was more effective than butyl-2-cyanoacrylate in the treatment of fractures in rats.
OBJETIVO: Os adesivos sintéticos são usados em várias especialidades médicas cirúrgicas, contudo, os estudos que relatam seu uso na prática ortopédica são escassos. O objetivo deste trabalho foi comparar os resultados do uso do etil-2-cianoacrilato e do butil-2-cianoacrilato no tratamento de fraturas em ratos. MÉTODOS: Foi realizado um estudo experimental, prospectivo e controlado em 90 ratos com fraturas de úmero, fêmur e tíbia, tratados com etil-2-cianoacrilato (grupo SB; n = 45) ou butil-2-cianoacrilato (grupo HA; n = 45). Foram realizadas análises biomecânicas e histomorfométricas em três momentos (60, 120 e 180 dias), além do estudo clínico pela aferição semanal da massa corporal dos animais. RESULTADOS: Não foram observadas diferenças relacionadas à massa corporal dos animais (p = 0,07). Os fêmures de ambos os grupos não apresentaram diferença com relação à carga máxima (p = 0,6), limite de elasticidade (p = 0,6) e coeficiente de rigidez (p = 0,4). Analisando-se as tíbias, o mesmo foi observado com relação à carga máxima (p = 0,4), ao limite de elasticidade (p = 0,7) e ao coeficiente de rigidez (p = 0,6). Os úmeros de ambos os grupos apresentaram a mesma área de calo ósseo formado (p = 0,66). Em ambos os grupos, não houve diferença estatística relacionada ao número de osteoblastos (p = 0,2), osteoclastos (p = 0,2) e células inflamatórias (p = 0,4). CONCLUSÃO: O etil-2-cianoacrilato foi mais eficaz do que o butil-2-cianoacrilato no tratamento de fraturas em ratos.
RESUMO
To assess, through a systematic literature review, whether or not it is necessary to suspend antithrombotic medications (warfarin, aspirin, and clopidogrel) to perform elective wrist and hand surgeries. The search for articles was performed using a combination of keywords in the databases available, without scientific design constraints, being selected series with five or more surgeries; the selected articles were analyzed regarding serious (need for surgical treatment) and mild complications (without surgery). Seven articles were retrieved and analyzed; 410 wrist and hand surgeries were performed in patients on warfarin or aspirin and clopidogrel, with three serious complications (0.7%) and 38 mild (9.2%); 2023 surgeries were performed in patients without use of antithrombotics, with zero serious and 18 (0.8%) minor complications. Patients using warfarin or oral antiplatelet (aspirin, clopidogrel, and aspirin associated with clopidogrel) need not suspend the medication to undergo wrist and hand surgery.
Avaliar, por meio de revisão sistemática da literatura, se há ou não necessidade de suspender medicamentos antitrombóticos (varfarina, AAS e clopidogrel) para a realização de procedimentos eletivos de cirurgia do punho e da mão. A busca de artigos foi feita por meio da combinação de palavras-chave nas bases de dados disponíveis, sem restrições de desenho científico, sendo selecionadas séries com cinco ou mais cirurgias; os artigos selecionados foram analisados em relação às complicações graves (necessidade de tratamento cirúrgico) e leves (sem necessidade de tratamento cirúrgico). Sete artigos foram encontrados e analisados; 410 cirurgias do punho e da mão foram feitas em pacientes em uso de varfarina ou AAS e clopidogrel e observou três complicações graves (0,7%) e 38 leves (9,2%); 2.023 cirurgias foram feitas em pacientes sem uso dos antitrombóticos, apresentaram zero complicações graves e 18 leves (0,8%). Pacientes em uso de varfarina ou antiplaquetários orais (AAS, clopidogrel e AAS associado a clopidogrel) não necessitam suspender a medicação para ser submetidos a cirurgias do punho e da mão.
RESUMO
ABSTRACT Objective: Synthetic adhesives are used by various medical specialties, especially in surgery; however, studies reporting their use in orthopedic practice are scarce. The aim of this study was to compare the results in using ethyl-2-cyanoacrylate or butyl-2-cyanoacrylate in the treatment of fractures in rats. Methods: This was an experimental prospective controlled study in 90 rats, with humerus, femur, and tibia fractures, treated with ethyl-2-cyanoacrylate (SB group; n = 45) or butyl-2-cyanoacrylate (HA group; n = 45). Biomechanical and histomorphometric analyses were performed at three different moments (60, 120, and 180 days); besides a clinical study performed weekly by measurement of the animals body mass. Results: No differences were observed regarding body mass (p = 0.07). In both groups, there were no significant differences regarding maximum load (p = 0.6), yield point strength (p = 0.6), and stiffness coefficient (p = 0.4) of the femurs. The same was observed in tibias for maximum load (p = 0.4), yield point strength (p = 0.7), and stiffness coefficient (p = 0.6). The humerus from both groups had similar bone callus area (p = 0.66). In both groups, there were no statistical differences related to inflammatory cells (p = 0.4), osteoblasts (p = 0.2), and osteoclasts (p = 0.2). Conclusion: Ethyl-2-cyanoacrylate was more effective than butyl-2-cyanoacrylate in the treatment of fractures in rats.
RESUMO Objetivo: Os adesivos sintéticos são usados em várias especialidades médicas cirúrgicas, contudo, os estudos que relatam seu uso na prática ortopédica são escassos. O objetivo deste trabalho foi comparar os resultados do uso do etil-2-cianoacrilato e do butil-2-cianoacrilato no tratamento de fraturas em ratos. Métodos: Foi realizado um estudo experimental, prospectivo e controlado em 90 ratos com fraturas de úmero, fêmur e tíbia, tratados com etil-2-cianoacrilato (grupo SB; n = 45) ou butil-2-cianoacrilato (grupo HA; n = 45). Foram realizadas análises biomecânicas e histomorfométricas em três momentos (60, 120 e 180 dias), além do estudo clínico pela aferição semanal da massa corporal dos animais. Resultados: Não foram observadas diferenças relacionadas à massa corporal dos animais (p = 0,07). Os fêmures de ambos os grupos não apresentaram diferença com relação à carga máxima (p = 0,6), limite de elasticidade (p = 0,6) e coeficiente de rigidez (p = 0,4). Analisando-se as tíbias, o mesmo foi observado com relação à carga máxima (p = 0,4), ao limite de elasticidade (p = 0,7) e ao coeficiente de rigidez (p = 0,6). Os úmeros de ambos os grupos apresentaram a mesma área de calo ósseo formado (p = 0,66). Em ambos os grupos, não houve diferença estatística relacionada ao número de osteoblastos (p = 0,2), osteoclastos (p = 0,2) e células inflamatórias (p = 0,4). Conclusão: O etil-2-cianoacrilato foi mais eficaz do que o butil-2-cianoacrilato no tratamento de fraturas em ratos.
Assuntos
Animais , Ratos , Adesivos Teciduais , Consolidação da Fratura , Cianoacrilatos , Fraturas ÓsseasRESUMO
ABSTRACT To assess, through a systematic literature review, whether or not it is necessary to suspend antithrombotic medications (warfarin, aspirin, and clopidogrel) to perform elective wrist and hand surgeries. The search for articles was performed using a combination of keywords in the databases available, without scientific design constraints, being selected series with five or more surgeries; the selected articles were analyzed regarding serious (need for surgical treatment) and mild complications (without surgery). Seven articles were retrieved and analyzed; 410 wrist and hand surgeries were performed in patients on warfarin or aspirin and clopidogrel, with three serious complications (0.7%) and 38 mild (9.2%); 2023 surgeries were performed in patients without use of antithrombotics, with zero serious and 18 (0.8%) minor complications. Patients using warfarin or oral antiplatelet (aspirin, clopidogrel, and aspirin associated with clopidogrel) need not suspend the medication to undergo wrist and hand surgery.
RESUMO Avaliar, por meio de revisão sistemática da literatura, se há ou não necessidade de suspender medicamentos antitrombóticos (varfarina, AAS e clopidogrel) para a realização de procedimentos eletivos de cirurgia do punho e da mão. A busca de artigos foi feita por meio da combinação de palavras-chave nas bases de dados disponíveis, sem restrições de desenho científico, sendo selecionadas séries com cinco ou mais cirurgias; os artigos selecionados foram analisados em relação às complicações graves (necessidade de tratamento cirúrgico) e leves (sem necessidade de tratamento cirúrgico). Sete artigos foram encontrados e analisados; 410 cirurgias do punho e da mão foram feitas em pacientes em uso de varfarina ou AAS e clopidogrel e observou três complicações graves (0,7%) e 38 leves (9,2%); 2.023 cirurgias foram feitas em pacientes sem uso dos antitrombóticos, apresentaram zero complicações graves e 18 leves (0,8%). Pacientes em uso de varfarina ou antiplaquetários orais (AAS, clopidogrel e AAS associado a clopidogrel) não necessitam suspender a medicação para ser submetidos a cirurgias do punho e da mão.
Assuntos
Anticoagulantes , Mãos/cirurgia , VarfarinaRESUMO
OBJETIVO: Relacionar a área de secção inicial do enxerto com o resultado da cirurgia de reconstrução do LCA. Foram operados oito cães, divididos em dois grupos, de acordo com o tamanho do enxerto: grupo A - 25% e grupo B - 40% da largura do ligamento patelar (LP). MÉTODOS: Após oito meses, os cães foram sacrificados para análise macroscópica e histológica dos ligamentos reconstruídos, utilizando-se o joelho contralateral do cão como controle. RESULTADOS: Em ambos os grupos, todos os ligamentos reconstruídos apresentaram-se viáveis e hipertrofiados; o enxerto de LP teve sua morfologia alterada, verificada através da medida do crimp e da celularidade, assemelhando-se com a do LCA. CONCLUSÃO: A área de secção do enxerto não influenciou o resultado histológico da cirurgia de reconstrução do LCA em cães.
OBJECTIVE: To correlate the initial grafting section area with the outcomes from anterior cruciate ligament (ACL) reconstruction surgery. Eight dogs underwent operations, divided into two groups according to graft size: Group A, 25% and Group B, 40% of the patellar ligament (PL) width. METHODS: After eight months, the dogs were sacrificed for macroscopic and histological analysis on the reconstructed ligaments. Each dog's contralateral knee was used as a control. RESULTS: In both groups, all the reconstructed ligaments were seen to be viable and hypertrophied. The morphology of the PL grafting had changed, which was observed by measuring the crimp and cellularity, and it resembled that of the ACL. CONCLUSION: The grafting section area did not influence the histological outcomes from ACL reconstruction surgery in dogs.
Assuntos
Animais , Cães , Ligamento Cruzado Anterior , Técnicas Histológicas , TransplantesRESUMO
A luxação traumática isolada da articulação tibiofibular proximal é rara. Esta lesão pode não ser reconhecida ou diagnosticada no atendimento inicial. A ausência de suspeita clínica pode causar problemas para o diagnóstico. O diagnóstico necessita de história precisa do mecanismo e sintomas da lesão, avaliação clínica e radiográfica adequada de ambos joelhos. Casos não reconhecidos são fonte de alterações crônicas. O tratamento é feito por redução fechada e imobilização ou, em casos irredutíveis ou instáveis, redução aberta com fixação interna temporária. Um caso raro de luxação tibiofibular proximal isolada em um jogador de basquetebol é relatado para ilustrar essa lesão.
The isolated traumatic dislocation of the proximal tibiofibular joint is rare. The injury could go unrecognized or be misdiagnosed at the initial presentation. Lack of clinical suspicion can cause diagnostic problems. The diagnosis requires accurate history of the mechanism and symptoms of the injury, and adequate clinical and radiographic evaluation of the both knees. Overlooked injuries are a source of potentially chronic changes. The treatment is closed reduction and immobilization or, in case of a failed or unstable reduction, open reduction with temporary internal fixation. A rare case of acute isolated anterolateral dislocation of the proximal tibiofibular joint in a basketball player was described to illustrate this injury.
Assuntos
Humanos , Masculino , Adulto , Basquetebol , Fíbula/lesões , Luxação do Joelho/classificação , Luxação do Joelho , Luxação do Joelho/terapiaRESUMO
Fios de sutura de náilon (0,3-0 e 4-0), poliéster trançado (0,3-0 e 4-0) e polipropileno (0,3 e 4-0) de 7 marcas comercializadas no Brasil, foram submetidos a análise de diâmetro, comprimento, resistência do encastoamento, resistência à tração do fio sem nó e resistência à tração do fio com nó segundo metodologia padronizada pela Associação Brasileira de Normas Técnicas (ABNT).Os resultados obtidos indicam que a maioria dos fios testados encontra-se dentro dos valores preconizados pela ABNT.
Assuntos
Fios Ortopédicos , Suturas , Poliésteres , Polipropilenos , Controle de Qualidade , Resistência à TraçãoRESUMO
Com a finalidade de se comparar as propriedades mecânicas do ligamento da patela e do tendão calcâneo foram realizados ensaios de tração em material obtido de 25 cadáveres humanos. A idade dos doadores foi 58 ± 14 anos (33-85), sendo 19 (76 por cento) masculinos e 6 (24 por cento) femininos, 23 brancos (92 por cento) e dois negros (8 por cento). Os materiais foram testados em seus 10 mm centrais, com velocidade de aplicação de carga de 30 mm/min. Foi obtida a área de secção dos corpos de prova para que fossem estudadas as propriedades estruturais e materiais. Foram estudadas as seguintes variáveis: carga máxima (N), tensão(MPa), módulo de elasticidade (MPa), energia (Nm), alongamento absoluto (mm) e específico ( por cento), limite de proporcionalidade (N), além da tensão (MPa) e alongamentos neste ponto. A análise estatística revelou que ambos possuem carga máxima, limite de proporcionalidade e tensão semelhantes (p>0,05). Nas outras variáveis ocorreu diferença significativa (p<0,05) com o tendão calcâneo apresentando valores maiores para energia e alongamento. O módulo de elasticidade, significativamente maior no ligamento da patela (p<0,05), foi a variável que melhor caracterizou a diferença do comportamento mecânico dos dois materiais.