Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
J Ultrasound Med ; 42(12): 2815-2824, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37605863

RESUMO

OBJECTIVES: Preeclampsia (PE) is a severe complication of pregnancy characterized by hypertension, proteinuria and compromised fetal blood supply. The eye, like other end organs, is affected by this systemic condition, but unlike in other organs, ocular media transparency allows high-resolution optical visualization of the vascular structure of the retina. Our aim was to assess how ultrasound-determined ocular blood-flow correlates with vascular structure of the retina and choriocapillaris determined by optical coherence tomography angiography (OCTA). METHODS: Plane-wave ultrasound and OCTA were performed on both eyes of 40 consecutive subjects consisting of normal controls (n = 11), mild PE (n = 5), severe PE (n = 17) and chronic or gestational hypertension (n = 7) within 72 hours following delivery. From ultrasound, we measured pulsatile flow velocity and resistance indices in the central retinal artery (CRA) and vein, the short posterior ciliary arteries (SPCAs) and choroid. From OCTA, we measured vascular density (VD) in the superficial, deep retina and choriocapillaris. We determined differences in Doppler and OCTA parameters among groups and correlations between ultrasound and OCTA. RESULTS: In severe PE, flow resistance was reduced with respect to controls. Flow velocity and resistance in the and SPCA were moderately correlated with VD in the choriocapillaris and peripapillary retina, but VD in PE did not differ significantly from controls. CONCLUSIONS: Although OCTA parameters were moderately correlated with Doppler ultrasound, OCTA did not demonstrate significant differences between PE and controls postpartum.


Assuntos
Pré-Eclâmpsia , Vasos Retinianos , Feminino , Gravidez , Humanos , Vasos Retinianos/diagnóstico por imagem , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Pré-Eclâmpsia/diagnóstico por imagem , Ultrassonografia Doppler
2.
J Ultrasound Med ; 41(7): 1609-1622, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34724263

RESUMO

Ocular ultrasound is an invaluable tool for the evaluation of the eye and orbit. However, the eye and orbit are potentially sensitive to the thermal and mechanical effects of ultrasound. When performing B-mode imaging, dedicated ocular settings should be used. If these settings are not available, limiting the acoustic output to Food and Drug Administration (FDA) recommended maximum levels is strongly advised. Especially important is the acoustic output in spectral (pulsed) and color Doppler modes, which can exceed the FDA's maximum recommended levels for the eye. Adjusting settings to decrease acoustic output and limiting the time of the examination should be done when performing a Doppler examination. The acoustic output of shear wave elastography is significantly higher than FDA guidelines for the eye and should be considered experimental.


Assuntos
Feto , Sistemas Automatizados de Assistência Junto ao Leito , Acústica , Humanos , Ultrassonografia , Ultrassonografia Doppler
3.
Exp Eye Res ; 207: 108606, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33930396

RESUMO

Most studies of the effect of acute elevation of intraocular pressure (IOP) on ocular blood-flow have utilized optical coherence tomography (OCT) to characterize retinal and choroidal flow and vascular density. This study investigates the effect of acute IOP elevation on blood flow velocity in the retrobulbar arteries and veins supplying and draining the eye, which, unlike the retinal and choroidal vasculature, are not directly compressed as IOP is increased. By cannulation of the anterior chamber of 20 Sprague-Dawley rats, we increased IOP in 10 mmHg steps from 10 to 60 mmHg and returned to 10 mmHg. After 1 min at each IOP (and 3 min after return to 10 mmHg), we acquired 18 MHz plane-wave ultrasound data at 3000 compound images/sec for 1.5 s. We produced color-flow Doppler images by digital signal processing of the ultrasound data, identified retrobulbar arteries and veins, generated spectrograms depicting flow velocity over the cardiac cycle and characterized changes of vascular density and perfusion in the orbit overall. Systolic, diastolic and mean velocities and resistive and pulsatile indices were determined from arterial spectrograms at each IOP level. Baseline mean arterial and mean venous velocities averaged 30.9 ±â€¯10.8 and 8.5 ±â€¯3.3 mm/s, respectively. Arterial velocity progressively decreased and resistance indices increased at and above an IOP of 30 mmHg. Mean arterial velocity at 60 mmHg dropped by 55% with respect to baseline, while venous velocity decreased by 20%. Arterial and venous velocities and resistance returned to near baseline after IOP was restored to 10 mmHg. Both vascular density and orbital perfusion decreased with IOP, but while perfusion returned to near normal when IOP returned to 10 mmHg, density remained reduced. Our findings are consistent with OCT-based studies showing reduced perfusion of the retina at levels comparable to retrobulbar arterial flow velocity change with increased IOP. The lesser effect on venous flow is possibly attributable to partial collapse of the venous lumen as volumetric venous outflow decreased at high IOP. The continued reduction in orbital vascular density 3 min after restoration of IOP to 10 mmHg might be attributable to persisting narrowing of capillaries, but this needs to be verified in future studies.


Assuntos
Pressão Intraocular/fisiologia , Hipertensão Ocular/fisiopatologia , Órbita/irrigação sanguínea , Animais , Velocidade do Fluxo Sanguíneo , Corioide/irrigação sanguínea , Artérias Ciliares/fisiologia , Feminino , Masculino , Artéria Oftálmica/fisiologia , Ratos , Ratos Sprague-Dawley , Fluxo Sanguíneo Regional/fisiologia , Artéria Retiniana/fisiologia , Tonometria Ocular
4.
Ophthalmic Plast Reconstr Surg ; 37(4): e126-e127, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33315848

RESUMO

In cases of significant prematurity, neonates born with eyelid fusion can undergo spontaneous eyelid disjunction. Here, the authors present such a case, along with ultrasound findings shortly before eyelid separation. All protected patient information extracted for this report was done so in accordance with the Health Insurance Portability and Accountability Act. This report was prepared in accordance with the tenants of the Declaration of Helsinki.


Assuntos
Pálpebras , Pálpebras/diagnóstico por imagem , Humanos , Recém-Nascido
5.
Ophthalmic Plast Reconstr Surg ; 37(2): 138-140, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32501882

RESUMO

PURPOSE: Prior color-flow Doppler ultrasound studies of the eye have been performed with systems that exceed US Food and Drug Administration permissible ophthalmic ultrasonic energy limits. The authors report a study of orbital vascular malformations using a novel, Food and Drug Administration compliant, ultrafast compound coherent plane-wave ultrasound device to produce power Doppler images. METHODS: Using a Verasonics Vantage 128 ultrasound engine and a user-developed MATLAB program with a 5-MHz linear-array probe, compound coherent plane-wave ultrasound data were collected on patients with orbital vascular malformations. Real-time color-flow Doppler visualized orbital blood flow. Power Doppler images were produced by post-processing compound coherent plane-wave ultrasound data acquired continuously for 2 seconds. RESULTS: Compound coherent plane-wave ultrasound was performed on 3 orbital vascular malformations (1 venolymphatic malformation, 1 infantile hemangioma, and 1 arteriovenous malformation). Compound coherent plane-wave ultrasound produced a high-resolution depiction of orbital blood flow for orbital vascular malformations with high sensitivity to slow flow. CONCLUSIONS: Analysis of blood flow within orbital lesions informs treatment planning. Compound coherent plane-wave ultrasound is an emerging ultrasound modality that falls within the Food and Drug Administration guidelines for use in the orbit and provides information to characterize orbital vascular malformations.


Assuntos
Doenças Orbitárias , Malformações Vasculares , Humanos , Órbita/diagnóstico por imagem , Ultrassonografia , Ultrassonografia Doppler em Cores , Malformações Vasculares/diagnóstico
6.
Exp Eye Res ; 193: 107986, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32119869

RESUMO

Preclinical imaging, especially of rodent models, plays a major role in experimental ophthalmology. Our aim was to determine if ultrasound can be used to visualize and measure flow dynamics in the retrobulbar vessels supplying and draining the eye and the potential of contrast microbubbles to provide image and measurement enhancement. To accomplish this, we used a 128-element, 18 MHz linear array ultrasound probe and performed plane-wave imaging of the eyes of Sprague Dawley rats. Compound images were acquired by emitting unfocused wavefronts at multiple angles and combining echo data from all angles to form individual B-scans. Multiple imaging sequences were utilized, compounding up to six angles, with imaging rate of up to 3000 compound B-scans per second and sequence durations from 1.5 to 180 s. Data were acquired before and after intravenous introduction of contrast microbubbles. We found the total power of the Doppler signal in the image plane to increase approximately 20 fold after injection of contrast, followed by an exponential decay to baseline in about 90 s, The best-fit time constant of the decay averaged 41 s. While major vessels and the retinal/choroidal complex were evident pre-contrast, they were dramatically enhanced with contrast present, with details such as choroidal arterioles seen only with contrast. Ocular arteriovenous transit time determined from comparative enhancement curves in arteries and veins was approximately 0.2 s. In conclusion, plane wave ultrasound, especially with enhancement by contrast microbubbles, offers a means for the study of ocular hemodynamics using the rat eye as a model.


Assuntos
Meios de Contraste/farmacologia , Artéria Oftálmica/fisiologia , Órbita/irrigação sanguínea , Imagens de Fantasmas , Fluxo Sanguíneo Regional/fisiologia , Ultrassonografia/métodos , Animais , Modelos Animais , Artéria Oftálmica/diagnóstico por imagem , Ratos , Ratos Sprague-Dawley
7.
Ophthalmology ; 126(11): 1517-1526, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31471088

RESUMO

PURPOSE: Neodymium:yttrium-aluminum-garnet (Nd:YAG) laser treatment is performed on vitreous floaters, but studies of structural and functional effects with objective outcome measures are lacking. This study evaluated Nd:YAG laser effects by comparing participants with vitreous floaters who previously underwent laser treatment with untreated control participants and healthy persons without vitreous floaters using quantitative ultrasonography to evaluate vitreous structure and by measuring visual acuity and contrast sensitivity function to assess vision. DESIGN: Retrospective, comparative study. PARTICIPANTS: One eye was enrolled for each of 132 participants: 35 control participants without vitreous floaters, 59 participants with untreated vitreous floaters, and 38 participants with vitreous floaters previously Nd:YAG-treated. Of these, 25 were dissatisfied and sought vitrectomy; 13 were satisfied with observation. METHODS: The 39-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-39) to assess participant visual well-being, quantitative ultrasonography (QUS) to measure vitreous echodensity, and best-corrected visual acuity (BCVA) and contrast sensitivity function (CSF) to evaluate vision. MAIN OUTCOME MEASURES: Results of NEI-VFQ-39, QUS, BCVA, and CSF. RESULTS: Compared with control participants without vitreous floaters, participants with untreated vitreous floaters showed worse NEI-VFQ-39 results, 57% greater vitreous echodensity, and significant (130%) CSF degradation (P < 0.001 for each). Compared with untreated eyes with vitreous floaters, Nd:YAG-treated eyes had 23% less vitreous echodensity (P < 0.001), but no differences in NEI-VFQ-39 (P = 0.51), BCVA (P = 0.42), and CSF (P = 0.17) results. Of 38 participants with vitreous floaters who previously were treated with Nd:YAG, 25 were dissatisfied and seeking vitrectomy, whereas 13 were satisfied with observation. Participants seeking vitrectomy showed 24% greater vitreous echodensity (P = 0.018) and 52% worse CSF (P = 0.006). Multivariate linear regression models confirmed these findings. CONCLUSIONS: As a group, participants previously treated with Nd:YAG laser for bothersome vitreous floaters showed less dense vitreous, but similar visual function as untreated control participants with vitreous floaters. Because some treated eyes showed less dense vitreous and better visual function than those of untreated control participants, a prospective randomized study of Nd:YAG laser treatment of vitreous is warranted, using uniform laser treatment parameters and objective quantitative outcome measures.


Assuntos
Oftalmopatias/cirurgia , Lasers de Estado Sólido/uso terapêutico , Acuidade Visual/fisiologia , Corpo Vítreo/diagnóstico por imagem , Corpo Vítreo/cirurgia , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Oftalmopatias/diagnóstico por imagem , Oftalmopatias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Satisfação do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Perfil de Impacto da Doença , Inquéritos e Questionários , Ultrassonografia , Vitrectomia , Corpo Vítreo/fisiopatologia
8.
Ophthalmologica ; 240(1): 45-54, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29694963

RESUMO

OBJECTIVE: To evaluate PDE5/6 inhibition with sildenafil to reduce choroidal ischemia and treat age-related macular degeneration. METHODS: Sildenafil was prescribed to treat participants with macular degenerations or macular dystrophies measured by spectral-domain optical coherence tomography, color fundus photography, enhanced depth imaging, and best-corrected visual acuity. RESULTS: No change in calcified drusen was noted. Vitelliform-type soft drusen were not substantially changed. A participant with Best vitelliform macular dystrophy had a significant improvement in vision as well as in photoreceptor and ellipsoid layers. CONCLUSIONS: Our research supports sildenafil as a safe treatment for age-related and vitelliform macular degenerations. Thickened Bruch's membrane reduces the beneficial effect of perfusion increase, but all eyes appear to benefit from PDE6. Notably, maintenance or improvement in the photoreceptor layer may be the most significant result of sildenafil and is consistent with PDE6 inhibition. Thus, sil-denafil treatment of macular degeneration offers significant potential for vision retention and recovery.


Assuntos
Atrofia Geográfica/tratamento farmacológico , Inibidores da Fosfodiesterase 5/uso terapêutico , Citrato de Sildenafila/uso terapêutico , Distrofia Macular Viteliforme/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Nucleotídeo Cíclico Fosfodiesterase do Tipo 6/antagonistas & inibidores , Feminino , Atrofia Geográfica/diagnóstico por imagem , Atrofia Geográfica/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Fosfodiesterase 5/administração & dosagem , Projetos Piloto , Drusas Retinianas/patologia , Citrato de Sildenafila/administração & dosagem , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Distrofia Macular Viteliforme/diagnóstico por imagem , Distrofia Macular Viteliforme/fisiopatologia
9.
Ultrason Imaging ; 39(5): 313-325, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28675987

RESUMO

Quantitative assessment of the material properties of ocular tissues can provide valuable information for investigating several ophthalmic diseases. Quantitative acoustic microscopy (QAM) offers a means of obtaining such information, but few QAM investigations have been conducted on human ocular tissue. We imaged the optic nerve (ON) and iridocorneal angle in 12-µm deparaffinized sections of the human eye using a custom-built acoustic microscope with a 250-MHz transducer (7-µm lateral resolution). The two-dimensional QAM maps of ultrasound attenuation (α), speed of sound ( c), acoustic impedance ( Z), bulk modulus ( K), and mass density (ρ) were generated. Scanned samples were then stained and imaged by light microscopy for comparison with QAM maps. The spatial resolution and contrast of scanning acoustic microscopy (SAM) maps were sufficient to resolve anatomic layers of the retina (Re); anatomic features in SAM maps corresponded to those seen by light microscopy. Significant variations of the acoustic parameters were found. For example, the sclera was 220 MPa stiffer than Re, choroid, and ON tissue. To the authors' knowledge, this is the first systematic study to assess c, Z, K, ρ, and α of human ocular tissue at the high ultrasound frequencies used in this study.


Assuntos
Olho/diagnóstico por imagem , Microscopia Acústica/métodos , Humanos
10.
J Refract Surg ; 31(7): 438-45, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26186562

RESUMO

PURPOSE: To compare measurements of corneal epithelial thickness using optical coherence tomography (OCT) and very high-frequency digital ultrasound (VHFDU). METHODS: Retrospective analysis of 189 virgin corneas and 175 post-laser refractive surgery (LRS) corneas that had corneal epithelial thickness measurement with RTVue Fourier-domain OCT (Optovue, Inc., Fremont, CA) (tear film included) and Artemis VHFDU (ArcScan Inc., Morrison, CO) (tear film excluded). Averages were calculated for the central 2-mm diameter zone and for two further concentric annuli of 1.5- and 0.5-mm width, each divided into eight sectors. Agreement was analyzed by mean difference (OCT - VHFDU), 95% limits of agreement (LoA) (1.96 standard deviation of the difference), and Bland-Altman analysis. RESULTS: In virgin epithelium, mean central thickness was 53.4 ± 3.20 µm (range: 46 to 62 µm) with OCT and 54.1 ± 2.96 µm (range: 48 to 61 µm) with VHFDU; OCT measured thinnest in 70% with a mean difference of -0.71 µm (95% LoA of ± 3.94 µm, P < .001). In post-LRS epithelium, mean central thickness was 57.9 ± 6.08 µm (range: 42 to 77 µm) with OCT and 60.5 ± 6.47 µm (range: 42 to 79 µm) with VHFDU; OCT measured thinnest in 88%, with a mean difference of -2.48 µm (95% LoA of ± 5.33 µm, P < .001). A larger difference between methods was more common with thicker epithelium. CONCLUSIONS: Corneal epithelial thickness measurements using OCT were found to be slightly thinner than for VHFDU. In contrast to VHFDU, OCT measurement includes the tear film, so the true difference is probably approximately 4 µm more than reported. The difference was greatest inferiorly and higher for post-LRS eyes and in thicker epithelium.


Assuntos
Paquimetria Corneana , Epitélio Corneano/patologia , Tomografia de Coerência Óptica/métodos , Ultrassom/métodos , Adulto , Feminino , Análise de Fourier , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Masculino , Pessoa de Meia-Idade , Miopia/cirurgia , Estudos Retrospectivos , Adulto Jovem
11.
J Acoust Soc Am ; 137(5): EL381-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25994737

RESUMO

Ex vivo assessment of microscale tissue biomechanical properties of the mammalian retina could offer insights into diseases such as keratoconus, and macular degeneration. A 250-MHz scanning acoustic microscope (7-µm resolution) has been constructed to derive two-dimensional quantitative maps of attenuation (α), speed of sound (c), acoustic impedance (Z), bulk modulus (B), and mass density ( ρ). The two-dimensional maps were compared to coregistered hematoxylin-and-eosin stained sections. This study is the first to quantitatively assess α, c, Z, B, and ρ of individual retinal layers of mammalian animals at high ultrasound frequencies. Significant differences in these parameters between the layers were demonstrated.


Assuntos
Microscopia Acústica , Retina/diagnóstico por imagem , Oxirredutases do Álcool/deficiência , Oxirredutases do Álcool/genética , Animais , Fenômenos Biomecânicos , Módulo de Elasticidade , Genótipo , Processamento de Imagem Assistida por Computador , Camundongos Knockout , Fenótipo , Retina/enzimologia
12.
J Ultrasound Med ; 33(8): 1417-26, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25063407

RESUMO

OBJECTIVES: To noninvasively measure changes in corneal biomechanical properties induced by ultraviolet-activated riboflavin cross-linking therapy using acoustic radiation force (ARF). METHODS: Cross-linking was performed on the right eyes of 6 rabbits, with the left eyes serving as controls. Acoustic radiation force was used to assess corneal stiffness before treatment and weekly for 4 weeks after treatment. Acoustic power levels were within US Food and Drug Administration guidelines for ophthalmic safety. Strain, determined from ARF-induced displacement of the front and back surfaces of the cornea, was fit to the Kelvin-Voigt model to determine the elastic modulus (E) and coefficient of viscosity (η). The stiffness factor, the ratio of E after treatment to E before treatment, was calculated for treated and control eyes. At the end of 4 weeks, ex vivo thermal shrinkage temperature analysis was performed for comparison with in vivo stiffness measurements. One-way analysis of variance and Student t tests were performed to test for differences in E, η, the stiffness factor, and corneal thickness. RESULTS: Biomechanical stiffening was immediately evident in cross-linking-treated corneas. At 4 weeks after treatment, treated corneas were 1.3 times stiffer and showed significant changes in E (P= .006) and η (P= .007), with no significant effect in controls. Corneal thickness increased immediately after treatment but did not differ significantly from the pretreatment value at 4 weeks. CONCLUSIONS: Our findings demonstrate a statistically significant increase in stiffness in cross-linking-treated rabbit corneas based on in vivo axial stress/strain measurements obtained using ARF. The capacity to noninvasively monitor corneal stiffness offers the potential for clinical monitoring of cross-linking therapy.


Assuntos
Córnea/diagnóstico por imagem , Reagentes de Ligações Cruzadas/farmacologia , Técnicas de Imagem por Elasticidade/métodos , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Terapia Ultravioleta/métodos , Análise de Variância , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Fenômenos Biomecânicos/fisiologia , Córnea/efeitos dos fármacos , Paquimetria Corneana/métodos , Elasticidade/efeitos dos fármacos , Seguimentos , Coelhos , Viscosidade/efeitos dos fármacos
13.
Sci Rep ; 14(1): 7722, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565630

RESUMO

Retinopathy of prematurity (ROP) is a disorder affecting low birthweight, preterm neonates. In the preterm eye, the retina is not fully developed and neovascularization may occur at the margin between the developed vascular retina and undeveloped avascular retina. Without timely treatment by laser or intravitreal anti-vascular endothelial growth factor (VEGF) therapy, this can lead to tractional retinal detachment and blindness. Visualization of the retina in regular examinations by indirect ophthalmoscopy is hence the current standard of care, but the exams are stressful and interpretation of images is subjective. The upregulation of VEGF in ROP would suggest an increase in ocular blood flow. In this report, we evaluate the potential of ultrafast plane-wave Doppler ultrasound (PWU) to detect increased flow velocities in the orbital vessels supplying the eye in a gentle exam with objective findings. We imaged both eyes of 50 low-birthweight preterm neonates using 18 MHz PWU. Flow velocity in the central retinal artery (CRA) and vein (CRV), and the short posterior ciliary arteries were determined and values at each ROP Stage compared. We found significantly increased velocities in the CRA and CRV in Stage 3 ROP eyes, where intervention would be considered. We compared multivariate models for identifying Stage 3 eyes comprised solely of clinical factors, solely of Doppler parameters, and clinical plus Doppler parameters. The respective models provided areas under their respective ROC curves of 0.760, 0.812, and 0.904. PWU Doppler represents a gentle, objective means for identifying neonates at risk for ROP that could complement ophthalmoscopy.


Assuntos
Retinopatia da Prematuridade , Fator A de Crescimento do Endotélio Vascular , Recém-Nascido , Humanos , Peso ao Nascer , Hemodinâmica , Retina , Retinopatia da Prematuridade/diagnóstico por imagem
14.
J Refract Surg ; 29(1): 36-41, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23205905

RESUMO

PURPOSE: To compare corneal thickness profiles of cross-sections of cornea determined by arc-scanned immersion ultrasound and optical coherence tomography (OCT). METHODS: Corneas of 28 eyes from 14 participants were scanned in triplicate using the Artemis 2 high-frequency arc-scanned ultrasound system (ArcScan Inc) and the Visante OCT system (Carl Zeiss Meditec). Corneal thickness and reproducibility were compared within 3.5 mm of central cornea in the horizontal plane. RESULTS: Although highly correlated, Visante central and peripheral corneal thickness values were systematically thinner than Artemis 2 values. Within the central 0.5 mm, the difference was approximately 8 µm, but the difference increased with distance from the center. Reproducibility for each instrument was comparable, measuring <4 µm centrally and increasing peripherally. CONCLUSIONS: Visante OCT measurements of corneal thickness are thinner than Artemis 2 ultrasound values centrally with an increasing difference with peripheral position. Measurement reproducibility was comparable for the two techniques.


Assuntos
Córnea/anatomia & histologia , Paquimetria Corneana/instrumentação , Tomografia de Coerência Óptica/instrumentação , Humanos , Reprodutibilidade dos Testes
15.
Expert Rev Ophthalmol ; 18(6): 379-389, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38370284

RESUMO

Introduction: Ultrasound imaging of the eye was introduced over 50 years ago. While the physical principles of ultrasound imaging have not changed, technology has undergone tremendous and ongoing development. Areas covered: The fundamentals of ultrasound physics, biometry (A-scan), structural imaging (B-scan) and blood-flow imaging and measurement (Doppler) will be described. Emphasis will be placed on technological development and potential future advances. Expert opinion: While A- and B-scan ultrasound of the eye has traditionally been performed with focused single-element transducers, the introduction of annular and linear arrays has enhanced clinical utility. Future advances, especially in multielement arrays, and point-of-care systems promise amazing new capabilities for diagnostic imaging of the eye and orbit.

16.
Artigo em Inglês | MEDLINE | ID: mdl-37104812

RESUMO

PURPOSE: To investigate the posterior and equatorial scleral thickness in patients with autosomal dominant Best disease, a condition that has chronic subretinal fluid. METHODS: Retrospective study involving patients with Best disease and age-matched controls. Participants were evaluated with contact B-scan ultrasonography and enhanced depth imaging optical coherence tomography to evaluate scleral thickness in the posterior pole and equator. Univariate analysis and generalized estimating equations were used. RESULTS: Of 9 patients with genetically proven Best disease and 23 age-matched controls, there was no significant difference in the age or the gender proportion between groups. Subfoveal choroidal thickness and axial length were not significantly different between groups. Both posterior scleral (OD; 1.38mm vs. 0.89mm, P<.001 and OS; 1.39mm vs. 0.83mm, P<.001) and equatorial scleral (OD; 0.61mm vs. 0.42mm, P=.003, and OS; 0.55mm vs. 0.41mm, P=.017) thicknesses were much greater in cases as compared with controls. Multivariate analysis showed male sex and having Best disease were each significant predictors of posterior scleral thickness and Best disease was the sole significant predictor for equatorial scleral thickness. CONCLUSION: BEST1 gene may have a developmental role leading to having a thicker sclera, influencing disease manifestation, and contributing to the accumulation of subretinal fluid in Best disease.

17.
Invest Ophthalmol Vis Sci ; 64(13): 38, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37878303

RESUMO

Purpose: To establish a quantitative metric of posterior eyewall deformability in different directions of gaze in highly myopic eyes with and without posterior staphyloma. Methods: A prospective study was performed on 53 highly myopic patients (106 eyes). Ultrasound scans were acquired in primary, up, downward, nasal, and temporal gazes. A validated intensity-based segmentation algorithm was used to quantify the posterior eyewall geometry on digitalized B-scan images. Posterior eyewall local curvature (K) and distance (L) to the transducer were calculated. The associations between directions of gaze, axial length (AL), and presence of staphyloma with the K and L parameters were assessed. Results: A total of 53 participants (106 eyes) were studied. Multivariate regression analysis demonstrated that, after accounting for longer AL, and presence of staphyloma, eccentric gaze was often independently associated with various K and L parameters. Specifically, downward gaze was associated with increased posterior eyewall concavity as reflected in the maximum of K (KMax) (ß = 0.050, P < 0.001) and absolute value of KMax (ß = 0.041, P = 0.011). Both downward gaze and upgaze were independently associated with increase in the derivative of absolute KMax (which is consistent with more apparent, steeper staphyloma ridges), local KMax (which detects KMax at smaller intervals), and Kstd (which represents likelihood of staphyloma presence) and decrease in maximum of L (which represents movement of the staphyloma apex) with all P < 0.05. The ß coefficients for downward gaze were consistently greater in magnitude compared with those in upgaze. After accounting for AL and presence of staphyloma, horizontal gazes were independently associated only with decrease in the standard deviation of L (which also represents likelihood of staphyloma presence) and maximum of L. Conclusions: Downward gaze results in a significant increase in posterior eyewall concavity in highly myopic eyes after accounting for AL and staphyloma presence. In comparison with downward gaze, upgaze resulted in a lower magnitude, but significant changes in staphyloma ridge steepness and the likelihood of staphyloma presence. Horizontal gazes seemed to be associated with less posterior eyewall geometric parameters. Studies are required to further assess the association between downward gaze during near work on posterior eyewall concavity and possible effects on myopia development and progression.


Assuntos
Miopia , Doenças da Esclera , Humanos , Estudos Prospectivos , Olho , Miopia/diagnóstico , Ultrassonografia
18.
J Heart Lung Transplant ; 42(9): 1223-1232, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37098374

RESUMO

BACKGROUND: Reduced arterial pulsatility in continuous-flow left ventricular assist devices (CF-LVAD) patients has been implicated in clinical complications. Consequently, recent improvements in clinical outcomes have been attributed to the "artificial pulse" technology inherent to the HeartMate3 (HM3) LVAD. However, the effect of the "artificial pulse" on arterial flow, transmission of pulsatility into the microcirculation and its association with LVAD pump parameters is not known. METHODS: The local flow oscillation (pulsatility index, PI) of common carotid arteries (CCAs), middle cerebral arteries (MCAs) and central retinal arteries (CRAs-representing the microcirculation) were quantified by 2D-aligned, angle-corrected Doppler ultrasound in 148 participants: healthy controls, n = 32; heart failure (HF), n = 43; HeartMate II (HMII), n = 32; HM3, n = 41. RESULTS: In HM3 patients, 2D-Doppler PI in beats with "artificial pulse" and beats with "continuous-flow" was similar to that of HMII patients across the macro- and microcirculation. Additionally, peak systolic velocity did not differ between HM3 and HMII patients. Transmission of PI into the microcirculation was higher in both HM3 (during the beats with "artificial pulse") and in HMII patients compared with HF patients. LVAD pump speed was inversely associated with microvascular PI in HMII and HM3 (HMII, r2 = 0.51, p < 0.0001; HM3 "continuous-flow," r2 = 0.32, p = 0.0009; HM3 "artificial pulse," r2 = 0.23, p = 0.007), while LVAD pump PI was only associated with microcirculatory PI in HMII patients. CONCLUSIONS: The "artificial pulse" of the HM3 is detectable in the macro- and microcirculation but without creating a significant alteration in PI compared with HMII patients. Increased transmission of pulsatility and the association between pump speed and PI in the microcirculation indicate that the future clinical care of HM3 patients may involve individualized pump settings according to the microcirculatory PI in specific end-organs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Microcirculação , Insuficiência Cardíaca/cirurgia , Frequência Cardíaca , Artéria Cerebral Média
19.
Artigo em Inglês | MEDLINE | ID: mdl-35020595

RESUMO

Elevated intraocular pressure (IOP) is the most prevalent risk factor for initiation and progression of neurodegeneration in glaucoma. Ocular hypertension results from increased resistance to aqueous fluid outflow caused by reduced porosity and increased stiffness of tissues of the outflow pathway. Acoustic activation and resulting bioeffects of the perfluorocarbon (PFC) nanodroplets (NDs) introduced into the anterior chamber (AC) of the eye could potentially represent a treatment for glaucoma by increasing permeability in the aqueous outflow track. To evaluate the potential of NDs to enter the outflow track, 100-nm diameter perfluoropentane (PFP) NDs with a lipid shell were injected into the AC of ex vivo pig eyes and in vivo rat eyes. The NDs were activated and imaged with 18- and 28-MHz linear arrays to assess their location and diffusion. NDs in the AC could also be visualized using optical coherence tomography (OCT). Because of their higher density with respect to aqueous humor, some NDs settled into the iridocorneal angle where they entered the outflow pathway. After acoustic activation of the NDs at the highest acoustic pressure, small gas bubbles were observed in the AC. After two days, no acoustic activation events were visible in the AC of the rats and their eyes showed no evidence of inflammation.


Assuntos
Fluorocarbonos , Glaucoma , Animais , Humor Aquoso/metabolismo , Glaucoma/diagnóstico por imagem , Glaucoma/metabolismo , Pressão Intraocular , Ratos , Suínos , Ultrassonografia
20.
Ultrasound Med Biol ; 48(12): 2430-2441, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36096896

RESUMO

The aim of this study was to develop an eyewall curvature- and axial length (AxL)-based algorithm to automate detection (clinician-free) of staphyloma ridge and apex locations using ultrasound (US). Forty-six individuals (with emmetropia, high myopia or pathologic myopia) were enrolled in this study (AxL range: 22.3-39.3 mm), yielding 130 images in total. An intensity-based segmentation algorithm automatically tracked the posterior eyewall, calculating the posterior eyewall local curvature (K) and distance (L) to the transducer and the location of the staphyloma apex. By use of the area under the receiver operator characteristic (AUROC) curve to evaluate the diagnostic ability of eight local statistics derived from K, L and AxL, the algorithm successfully quantified non-uniformity of eye shape with an AUROC > 0.70 for most K-based parameters. The performance of binary classification (staphyloma absence vs. presence) was assessed with the best classifier (the combination of AxL, standard deviation of K and standard deviation of L) yielding a diagnostic validation performance of 0.897, which was comparable to the diagnostic performance of junior clinicians. The staphyloma apex was localized with an average error of 1.35 ± 1.34 mm. Combined with the real-time data acquisition capabilities of US, this method can be employed as a screening tool for clinician-free in vivo staphyloma detection.


Assuntos
Miopia Degenerativa , Doenças da Esclera , Humanos , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/patologia , Tomografia de Coerência Óptica , Doenças da Esclera/diagnóstico , Olho , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA