Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 60(4): 483-493, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-34773727

RESUMO

OBJECTIVES: Testing for thyroid disease constitutes a high proportion of the workloads of clinical laboratories worldwide. The setting of analytical performance specifications (APS) for testing methods and aiding clinical interpretation of test results requires biological variation (BV) data. A critical review of published BV studies of thyroid disease related measurands has therefore been undertaken and meta-analysis applied to deliver robust BV estimates. METHODS: A systematic literature search was conducted for BV studies of thyroid related analytes. BV data from studies compliant with the Biological Variation Data Critical Appraisal Checklist (BIVAC) were subjected to meta-analysis. Global estimates of within subject variation (CVI) enabled determination of APS (imprecision and bias), indices of individuality, and indicative estimates of reference change values. RESULTS: The systematic review identified 17 relevant BV studies. Only one study (EuBIVAS) achieved a BIVAC grade of A. Methodological and statistical issues were the reason for B and C scores. The meta-analysis derived CVI generally delivered lower APS for imprecision than the mean CVA of the studies included in this systematic review. CONCLUSIONS: Systematic review and meta-analysis of studies of BV of thyroid disease biomarkers have enabled delivery of well characterized estimates of BV for some, but not all measurands. The newly derived APS for imprecision for both free thyroxine and triiodothyronine may be considered challenging. The high degree of individuality identified for thyroid related measurands reinforces the importance of RCVs. Generation of BV data applicable to multiple scenarios may require definition using "big data" instead of the demanding experimental approach.


Assuntos
Lista de Checagem , Glândula Tireoide , Biomarcadores , Testes Hematológicos , Humanos , Valores de Referência
2.
Clin Chem Lab Med ; 60(4): 494-504, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35143717

RESUMO

OBJECTIVES: Biological variation data (BV) can be used for different applications, but this depends on the availability of robust and relevant BV data. In this study, we aimed to summarize and appraise BV studies for tumor markers, to examine the influence of study population characteristics and concentrations on BV estimates and to discuss the applicability of BV data for tumor markers in clinical practice. METHODS: Studies reporting BV data for tumor markers related to gastrointestinal, prostate, breast, ovarian, haematological, lung, and dermatological cancers were identified by a systematic literature search. Relevant studies were evaluated by the Biological Variation Data Critical Appraisal Checklist (BIVAC) and meta-analyses were performed for BIVAC compliant studies to deliver global estimates of within-subject (CVI) and between-subject (CVG) BV with 95% CI. RESULTS: The systematic review identified 49 studies delivering results for 22 tumor markers; four papers received BIVAC grade A, 3 B, 27 C and 15 D. Out of these, 29 CVI and 29 CVG estimates met the criteria to be included in the meta-analysis. Robust data are lacking to conclude on the relationship between BV and different disease states and tumor marker concentrations. CONCLUSIONS: This review identifies a lack of high-quality BV studies for many tumor markers and a need for delivery of BIVAC compliant studies, including in different disease states and tumor marker concentrations. As of yet, the state-of-the-art may still be the most appropriate model to establish analytical performance specifications for the majority of tumor markers.


Assuntos
Biomarcadores Tumorais , Lista de Checagem , Humanos , Masculino
3.
Clin Chem Lab Med ; 60(11): 1804-1812, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36036462

RESUMO

OBJECTIVES: The estimates of biological variation (BV) have traditionally been determined using direct methods, which present limitations. In response to this issue, two papers have been published addressing these limitations by employing indirect methods. Here, we present a new procedure, based on indirect methods that analyses data collected within a multicenter pilot study. Using this method, we obtain CVI estimates and calculate confidence intervals (CI), using the EFLM-BVD CVI estimates as gold standard for comparison. METHODS: Data were collected over a 18-month period for 7 measurands, from 3 Spanish hospitals; inclusion criteria: patients 18-75 years with more than two determinations. For each measurand, four different strategies were carried out based on the coefficient of variation ratio (rCoeV) and based on the use of the bootstrap method (OS1, RS2 and RS3). RS2 and RS3 use symmetry reference change value (RCV) to clean database. RESULTS: RS2 and RS3 had the best correlation for the CVI estimates with respect to EFLM-BVD. RS2 used the symmetric RCV value without eliminating outliers, while RS3 combined RCV and outliers. When using the rCoeV and OS1 strategies, an overestimation of the CVI value was obtained. CONCLUSIONS: Our study presents a new strategy for obtaining robust CVI estimates using an indirect method together with the value of symmetric RCV to select the target population. The CVI estimates obtained show a good correlation with those published in the EFLM-BVD database. Furthermore, our strategy can resolve some of the limitations encountered when using direct methods such as calculating confidence intervals.


Assuntos
Mineração de Dados , Bases de Dados Factuais , Humanos , Projetos Piloto , Valores de Referência
5.
Adv Lab Med ; 1(3): 20200029, 2020 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37361503

RESUMO

Objectives: Numerous biological variation (BV) studies have been performed over the years, but the quality of these studies vary. The objectives of this study were to perform a systematic review and critical appraisal of BV studies on glycosylated albumin and to deliver updated BV estimates for glucose and HbA1c, including recently published high-quality studies such as the European Biological Variation study (EuBIVAS). Methods: Systematic literature searches were performed to identify BV studies. Nine publications not included in a previous review were identified; four for glycosylated albumin, three for glucose, and three for HbA1c. Relevant studies were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Global BV estimates were derived by meta-analysis of BIVAC-compliant studies in healthy subjects with similar study design. Results: One study received BIVAC grade A, 2B, and 6C. In most cases, the C-grade was associated with deficiencies in statistical analysis. BV estimates for glycosylated albumin were: CVI=1.4% (1.2-2.1) and CVG=5.7% (4.7-10.6), whereas estimates for HbA1c, CVI=1.2% (0.3-2.5), CVG=5.4% (3.3-7.3), and glucose, CVI=5.0% (4.1-12.0), CVG=8.1% (2.7-10.8) did not differ from previously published global estimates. Conclusions: The critical appraisal and rating of BV studies according to their methodological quality, followed by a meta-analysis, generate robust, and reliable BV estimates. This study delivers updated and evidence-based BV estimates for glycosylated albumin, glucose and HbA1c.

6.
Adv Lab Med ; 1(1): 20200008, 2020 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37362553

RESUMO

Background: The objective of the present study was to examine the evolution of the analytical performance specifications (APS) used in External Quality Assurance (EQA) schemes, as well as the efficacy of a category 1 EQA scheme in monitoring the harmonization of clinical laboratory results in Spain. Methods: A review of the literature on the types of quality specifications used in schemes in other countries and their evolution was performed. In addition, a comparative analysis of the potential impact that different APS from eight countries had on clinical decision-making was made based on three measurands: sodium, thyroid-stimulating hormone (TSH), and activated partial thromboplastin time (aPTT). Results: Harmonization of analytical methods was demonstrated by assessing whether average results deviated from the certified reference value of control materials within the APS derived from biological variation (BV). The APS used in EQA have evolved from state-of-the-art models to BV. Poor clinical decision-making would occur if the results accepted by some APS were applied. Conclusions: In Spain, only 2 of the 18 measurands studied are considered to be well harmonized. Closer collaboration between laboratories and analytical system providers would be required to resolve discrepancies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA